Infineon HYB25D128800CT-6 128 mbit double data rate sdram Datasheet

D a t a S h e e t , Rev. 1.0, A p r . 2 0 0 4
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Memory Products
N e v e r
s t o p
t h i n k i n g .
Edition 2004-04
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
81669 München, Germany
© Infineon Technologies AG 2004.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as a guarantee of
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.
D a t a S h e e t , Rev. 1.0, A p r . 2 0 0 4
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
DDR SDRAM
Memory Products
N e v e r
s t o p
t h i n k i n g .
HYB25D128[400/800/160]C[C/E/T](L)
Revision History:
Rev. 1.0
2004-04
Previous Version:
Rev. 0.5
2003-11
Page
Subjects (major changes since last revision)
removed Green and Standard form Cover Page
9
added Product Types removed Product Types
70
updated IDD values
We Listen to Your Comments
Any information within this document that you feel is wrong, unclear or missing at all?
Your feedback will help us to continuously improve the quality of this document.
Please send your proposal (including a reference to this document) to:
[email protected]
Template: mp_a4_v2.2_2003-10-07.fm
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Table of Contents
1
1.1
1.2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2
Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3
3.1
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.3
3.3.1
3.3.2
3.4
3.5
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.6
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mode Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Burst Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Burst Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read Latency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Extended Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DLL Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Drive Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bank/Row Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Precharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simplified State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
20
21
21
22
22
23
24
24
24
25
28
28
29
38
52
53
58
4
4.1
4.2
4.3
4.3.1
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Strength Pull-down and Pull-up Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weak Strength Pull-down and Pull-up Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDD Current Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59
61
63
65
71
5
Timing Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
6
Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Data Sheet
5
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
List of Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
Figure 52
Data Sheet
Pin Configuration P-TFBGA-60-9 Top View, see the balls throught the package . . . . . . . . . . . . .
Pin Configuration P-TSOPII-66-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Block Diagram 128Mbit ×16 Mbit ×16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Block Diagram 128Mbit ×32 Mbit ×8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Block Diagram 128Mbit ×64 Mbit ×4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required CAS Latencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Activating a Specific Row in a Specific Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tRCD and tRRD Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read Burst: CAS Latencies (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8) . . . . . . . . . . . . . . . . . . . . . . . .
Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . .
Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) . . . . . . . . . . . . . . . . . . . . . . .
Terminating a Read Burst: CAS Latencies (Burst Length = 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read to Write: CAS Latencies (Burst Length = 4 or 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read to Precharge: CAS Latencies (Burst Length = 4 or 8). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write Burst (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Write (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Write: Max. DQSS, Non-Consecutive (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . .
Random Write Cycles (Burst Length = 2, 4 or 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Read: Non-Interrupting (CAS Latency = 2; Burst Length = 4). . . . . . . . . . . . . . . . . . . . . .
Write to Read: Interrupting (CAS Latency = 2; Burst Length = 8). . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Read: Min. DQSS, Odd Number of Data (3-bit Write), Interrupting (CL2; BL8) . . . . . . . .
Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8) . . . . . . . . . . . .
Write to Precharge: Non-Interrupting (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Precharge: Interrupting (Burst Length = 4 or 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write to Precharge: Minimum DQSS, Odd Number of Data (1-bit Write), Interrupting (BL 4 or 8).
Write to Precharge: Nominal DQSS (2-bit Write), Interrupting (Burst Length = 4 or 8) . . . . . . . . .
Precharge Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simplified State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Strength Pull-down Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Strength Pull-up Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weak Strength Pull-down Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weak Strength Pull-up Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Output Load Circuit Diagram / Timing Reference Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Input (Write), Timing Burst Length = 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Output (Read), Timing Burst Length = 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialize and Mode Register Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Down Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auto Refresh Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Self Refresh Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read without Auto Precharge (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read with Auto Precharge (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bank Read Access (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write without Auto Precharge (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write with Auto Precharge (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bank Write Access (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Write DM Operation (Burst Length = 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P-TFBGA-60-2 (Plastic Thin Fine-Pitch Ball Grid Array Package) . . . . . . . . . . . . . . . . . . . . . . . . .
P-TSOPII-66-1 (Plastic Thin Small Outline Package Type II). . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
15
16
17
18
19
23
28
28
29
30
31
32
33
35
36
37
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
58
61
61
63
63
65
72
72
73
74
75
76
77
78
79
80
81
82
83
84
84
Rev. 1.0, 2004-04
10222003-25HM-16E0
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
List of Tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 7
Table 6
Table 9
Table 8
Table 10
Table 11
Table 12
Table 13
Table 14
Table 16
Table 15
Table 17
Table 19
Table 18
Table 20
Table 21
Data Sheet
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Pin Configuration of DDR SDRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Abbreviations for Pin Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Abbreviations for Buffer Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Burst Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Truth Table 1b: DM Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Truth Table 1a: Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Truth Table 3: Current State Bank n - Command to Bank n (same bank) . . . . . . . . . . . . . . . . . . . 54
Truth Table 2: Clock Enable (CKE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Truth Table 4: Current State Bank n - Command to Bank m (different bank). . . . . . . . . . . . . . . . . 56
Truth Table 5: Concurrent Auto Precharge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Input and Output Capacitances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Electrical Characteristics and DC Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Evaluation Conditions for I/O Driver Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Normal Strength Pull-down and Pull-up Currents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Weak Strength Driver Pull-down and Pull-up Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
AC Timing - Absolute Specifications for PC3200, PC2700 and PC2100 . . . . . . . . . . . . . . . . . . . . 66
AC Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
IDD Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
IDD Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
7
Rev. 1.0, 2004-04
10222003-25HM-16E0
128 Mbit Double Data Rate SDRAM
DDR SDRAM
1
Overview
1.1
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
HYB25D128[400/800/160]C[C/E/T](L)
Double data rate architecture: two data transfers per clock cycle
Bidirectional data strobe (DQS) is transmitted and received with data, to be used in capturing data at the
receiver
DQS is edge-aligned with data for reads and is center-aligned with data for writes
Differential clock inputs
Four internal banks for concurrent operation
Data mask (DM) for write data
DLL aligns DQ and DQS transitions with CK transitions
Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS
Burst Lengths: 2, 4, or 8
CAS Latency: 2, 2.5, 3
Auto Precharge option for each burst access
Auto Refresh and Self Refresh Modes
7.8 µs Maximum Average Periodic Refresh Interval
2.5 V (SSTL_2 compatible) I/O
VDDQ = 2.5 V ± 0.2 V (DDR266A, DDR333); VDDQ = 2.6 V ± 0.1 V (DDR400)
VDD = 2.5 V ± 0.2 V (DDR266, DDR333); VDD = 2.6 V ± 0.1 V (DDR400)
P-TFBGA-60-2 package with 3 depopulated rows (12 × 8 mm2)
P-TSOPII-66-1 package
Lead- and halogene-free = green product
1.2
Description
The 128 Mbit Double Data Rate SDRAM is a high-speed CMOS, dynamic random-access memory containing
268,435,456 bits. It is internally configured as a quad-bank DRAM.
The 128 Mbit Double Data Rate SDRAM uses a double-data-rate architecture to achieve high-speed operation.
The double data rate architecture is essentially a 2n prefetch architecture with an interface designed to transfer
two data words per clock cycle at the I/O pins. A single read or write access for the 128 Mbit Double Data Rate
SDRAM effectively consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and
two corresponding n-bit wide, one-half-clock-cycle data transfers at the I/O pins.
A bidirectional data strobe (DQS) is transmitted externally, along with data, for use in data capture at the receiver.
DQS is a strobe transmitted by the DDR SDRAM during Reads and by the memory controller during Writes. DQS
is edge-aligned with data for Reads and center-aligned with data for Writes.
The 128 Mbit Double Data Rate SDRAM operates from a differential clock (CK and CK; the crossing of CK going
HIGH and CK going LOW is referred to as the positive edge of CK). Commands (address and control signals) are
registered at every positive edge of CK. Input data is registered on both edges of DQS, and output data is
referenced to both edges of DQS, as well as to both edges of CK.
Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and
continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration
of an Active command, which is then followed by a Read or Write command. The address bits registered
coincident with the Active command are used to select the bank and row to be accessed. The address bits
registered coincident with the Read or Write command are used to select the bank and the starting column location
for the burst access.
Data Sheet
8
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Overview
The DDR SDRAM provides for programmable Read or Write burst lengths of 2, 4 or 8 locations. An Auto
Precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst
access.
As with standard SDRAMs, the pipelined, multibank architecture of DDR SDRAMs allows for concurrent
operation, thereby providing high effective bandwidth by hiding row precharge and activation time.
An auto refresh mode is provided along with a power-saving power-down mode. All inputs are compatible with the
JEDEC Standard for SSTL_2. All outputs are SSTL_2, Class II compatible.
Note: The functionality described and the timing specifications included in this data sheet are for the DLL Enabled
mode of operation.
Table 1
Ordering Information
Part Number1)
Org.
CAS-RCD- Clock
RP
(MHz)
Latencies
CAS-RCD- Clock Speed
RP
(MHz)
Latencies
Package
HYB25D128160CT-5
×16
3-3-3
200
2.5-3-3
166
DDR400B
P-TSOPII-66-1
HYB25D128160CT-6
×16
2.5-3-3
166
2-3-3
133
DDR333
HYB25D128800CT-6
×8
HYB25D128800CTL-6
×8
HYB25D128400CT-7
×4
DDR266A
HYB25D128400CC-6
×4
DDR333
P-FBGA-60-2
HYB25D128160CE–5
×16
3-3-3
200
2.5-3-3
166
DDR400B
P-TSOPII-66-1
HYB25D128400CE–6
×4
2.5-3-3
166
2-3-3
133
DDR333
HYB25D128800CE–6
×8
HYB25D128800CEL–6
×8
HYB25D128160CE–6
×16
1) HYB: designator for memory components
25D: DDR SDRAMs at VDDQ = 2.5 V
128: 128-Mbit density
400/800/160: Product variations x4, x8 and x16
C: Die revision C
T/E/C: Package type TSOP and FBGA
L: Low power version (optional) - these components are specifically selected for low IDD6 Self Refresh currents
-5/6/7/7F/8: speed grade - see Table 1
Data Sheet
9
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
2
Pin Configuration
The pin configuration of a DDR SDRAM is listed by function in Table 2 (60 pins). The abbreviations used in the
Pin#/Buffer# column are explained in Table 3 and Table 4 respectively. The pin numbering for FBGA is depicted
in Figure 1 and that of the TSOP package in Figure 2
Table 2
Pin Configuration of DDR SDRAM
Ball#/Pin#
Name
Pin
Type
Buffer
Type
Function
CK1
I
SSTL
Clock Signal
Clock Signals
G2, 45
Note: CK and CK are differential clock inputs. All address and
control input signals are sampled on the crossing of the
positive edge of CK and negative edge of CK. Output (read)
data is referenced to the crossings of CK and CK (both
directions of crossing).
G3, 46
CK1
I
SSTL
Complementary Clock Signal
H3, 44
CKE
I
SSTL
Clock Enable
Note: CKE HIGH activates, and CKE Low deactivates, internal
clock signals and device input buffers and output drivers.
Taking CKE Low provides Precharge Power-Down and Self
Refresh operation (all banks idle), or Active Power-Down
(row Active in any bank). CKE is synchronous for power
down entry and exit, and for self refresh entry. CKE is
asynchronous for self refresh exit. CKE must be maintained
high throughout read and write accesses. Input buffers,
excluding CK, CK and CKE are disabled during powerdown. Input buffers, excluding CKE, are disabled during self
refresh.
Control Signals
H7, 23
RAS
I
SSTL
Row Address Strobe
G8, 22
CAS
I
SSTL
Column Address Strobe
G7, 21
WE
I
SSTL
Write Enable
H8, 24
CS
I
SSTL
Chip Select
Note: All commands are masked when CS is registered HIGH. CS
provides for external bank selection on systems with
multiple banks. CS is considered part of the command code.
The standard pinout includes one CS pin.
Address Signals
J8, 26
BA0
I
SSTL
Bank Address Bus 2:0
J7, 27
BA1
I
SSTL
Note: BA0 and BA1 define to which bank an Active, Read, Write
or Precharge command is being applied. BA0 and BA1 also
determines if the mode register or extended mode register
is to be accessed during a MRS or EMRS cycle.
Data Sheet
10
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Table 2
Pin Configuration of DDR SDRAM
Ball#/Pin#
Name
Pin
Type
Buffer
Type
Function
K7, 29
A0
I
SSTL
Address Bus 11:0
L8, 30
A1
I
SSTL
L7, 31
A2
I
SSTL
M8, 32
A3
I
SSTL
M2, 35
A4
I
SSTL
L3, 36
A5
I
SSTL
L2, 37
A6
I
SSTL
K3, 38
A7
I
SSTL
Note: Provide the row address for Active commands, and the
column address and Auto Precharge bit for Read/Write
commands, to select one location out of the memory array
in the respective bank. A10 is sampled during a Precharge
command to determine whether the Precharge applies to
one bank (A10 LOW) or all banks (A10 HIGH). If only one
bank is to be precharged, the bank is selected by BA0, BA1.
The address inputs also provide the op-code during a Mode
Register Set command.
K2, 39
A8
I
SSTL
J3, 40
A9
I
SSTL
K8, 28
A10
I
SSTL
AP
I
SSTL
J2, 41
A11
I
SSTL
H2, 42
A12
I
SSTL
Address Signal 12
Note: Module based on 256 Mbit or larger dies
F9, 17
NC
NC
—
Note: Module based on 128 Mbit or smaller dies
A13
I
SSTL
Address Signal 13
Note: 1 Gbit based module
NC
NC
—
Note: Module based on 512 Mbit or smaller dies
Data Signal Bus 3:0
Data Signals ×4 organization
B7, 5
DQ0
I/O
SSTL
D7, 11
DQ1
I/O
SSTL
D3, 56
DQ2
I/O
SSTL
B3, 62
DQ3
I/O
SSTL
Data Strobe ×4 organisation
E3, 51
DQS
I/O
SSTL
Data Strobe
Note: Output with read data, input with write data. Edge-aligned
with read data, centered in write data. Used to capture write
data.
Data Mask ×4 organization
F3, 47
DM
I
SSTL
Data Mask
Note: DM is an input mask signal for write data. Input data is
masked when DM is sampled HIGH coincident with that
input data during a Write access. DM is sampled on both
edges of DQS. Although DM pins are input only, the DM
loading matches the DQ and DQS loading
Data Sheet
11
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Table 2
Ball#/Pin#
Pin Configuration of DDR SDRAM
Name
Pin
Type
Buffer
Type
Function
Data Signal Bus 7:0
Data Signals ×8 organization
A8, 2
DQ0
I/O
SSTL
B7, 5
DQ1
I/O
SSTL
C7, 8
DQ2
I/O
SSTL
D7, 11
DQ3
I/O
SSTL
D3, 56
DQ4
I/O
SSTL
C3, 59
DQ5
I/O
SSTL
B3, 62
DQ6
I/O
SSTL
A2, 65
DQ7
I/O
SSTL
Data Strobe ×8 organisation
E3, 51
DQS
I/O
SSTL
Data Strobe
Note: Output with read data, input with write data. Edge-aligned
with read data, centered in write data. Used to capture write
data.
Data Mask ×8 organization
F3, 47
DM
I
SSTL
Data Mask
Note: DM is an input mask signal for write data. Input data is
masked when DM is sampled HIGH coincident with that
input data during a Write access. DM is sampled on both
edges of DQS. Although DM pins are input only, the DM
loading matches the DQ and DQS loading.
Data Signals ×16 organization
A8, 2
DQ0
I/O
SSTL
B9, 4
DQ1
I/O
SSTL
B7, 5
DQ2
I/O
SSTL
C9, 7
DQ3
I/O
SSTL
C7, 8
DQ4
I/O
SSTL
D9, 10
DQ5
I/O
SSTL
D7, 11
DQ6
I/O
SSTL
E9, 13
DQ7
I/O
SSTL
E1, 54
DQ8
I/O
SSTL
D3, 56
DQ9
I/O
SSTL
D1, 57
DQ10
I/O
SSTL
C3, 59
DQ11
I/O
SSTL
C1, 60
DQ12
I/O
SSTL
B3, 62
DQ13
I/O
SSTL
B1, 63
DQ14
I/O
SSTL
A2, 65
DQ15
I/O
SSTL
Data Signal 15:0
Data Strobe ×16 organization
E3, 51
UDQS
I/O
SSTL
Data Strobe Upper Byte
E7, 16
LDQS
I/O
SSTL
Data Strobe Lower Byte
Data Mask ×16 organization
Data Sheet
12
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Table 2
Pin Configuration of DDR SDRAM
Ball#/Pin#
Name
Pin
Type
Buffer
Type
Function
F3, 47
UDM
I
SSTL
Data Mask Upper Byte
F7, 20
LDM
I
SSTL
Data Mask Lower Byte
VREF
VDDQ
AI
—
I/O Reference Voltage
PWR
—
I/O Driver Power Supply
A7, F8, M3,
M7, 1, 18, 33
VDD
PWR
—
Power Supply
A1, B8, C2,
D8, E2, 6, 12,
52, 58, 64
VSSQ
PWR
—
Power Supply
F2, 34
VSS
PWR
—
Power Supply
NC
NC
—
Not Connected
Power Supplies
F1, 49
A9, B2, C8,
D2, E8, 3, 9,
15, 55, 61
Not Connected
A2, 65
Note: ×4 organization
A8, 2
NC
NC
—
Not Connected
Note: ×4 organization
B1, 63
NC
NC
—
Not Connected
Note: ×8 and ×4 organisation
B9, 4
NC
NC
—
Not Connected
C1, 60
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
Note: ×8 and ×4 organization
C3, 59
NC
NC
—
Not Connected
Note: ×4 organization
C7, 8
NC
NC
—
Not Connected
Note: ×4 organization
C9, 7
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
D1, 57
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
D9, 10
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
E1, 54
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
E7, 16
NC
NC
—
E9, 13
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
Not Connected
Note: ×8 and ×4 organization
F7, 20
NC
NC
—
Not Connected
Note: ×8 and ×4 organization
Data Sheet
13
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Table 2
Ball#/Pin#
Pin Configuration of DDR SDRAM
Name
14, 17, 19, 25, NC
43, 50
Table 3
Pin
Type
Buffer
Type
Function
NC
—
Not Connected
×16,×8 and ×4 organization
Abbreviations for Pin Type
Abbreviation
Description
I
Standard input-only pin. Digital levels.
O
Output. Digital levels.
I/O
I/O is a bidirectional input/output signal.
AI
Input. Analog levels.
PWR
Power
GND
Ground
NC
Not Connected (JEDEC Standard)
Table 4
Abbreviations for Buffer Type
Abbreviation
Description
SSTL
Serial Stub Terminalted Logic (SSTL2)
LV-CMOS
Low Voltage CMOS
CMOS
OD
Data Sheet
CMOS Levels
Open Drain. The corresponding pin has 2 operational states, active low and tristate, and
allows multiple devices to share as a wire-OR.
14
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
1
2
3
VSSQ
N.C.
VSS
N.C.
VDDQ
N.C.
7
8
9
1
2
3
A
VDD
N.C.
VDDQ
VSSQ
DQ7
VSS
DQ3
B
DQ0
VSSQ
N.C.
N.C.
VDDQ
VSSQ
N.C.
C
N.C.
VDDQ
N.C.
N.C.
N.C.
VDDQ
DQ2
D
DQ1
VSSQ
N.C.
N.C.
VSSQ
DQS
E
N.C.
VDDQ
VREF
VSS
DM
F
N.C.
VDD
CK
CK
G
WE
CAS
H
RAS
CS
NC/A12 CKE
4
5
6
4
7
8
9
A
VDD
DQ0
VDDQ
DQ6
B
DQ1
VSSQ
N.C.
VSSQ
DQ5
C
DQ2
VDDQ
N.C.
N.C.
VDDQ
DQ4
D
DQ3
VSSQ
N.C.
N.C.
N.C.
VSSQ
DQS
E
N.C.
VDDQ
N.C.
NC/A13
VREF
VSS
DM
F
N.C.
VDD
NC/A13
CK
CK
G
WE
CAS
H
RAS
CS
NC/A12 CKE
5
6
A11
A9
J
BA1
BA0
A11
A9
J
BA1
BA0
A8
A7
K
A0
A10/AP
A8
A7
K
A0
A10/AP
A6
A5
L
A2
A1
A6
A5
L
A2
A1
A4
VSS
M
VDD
A3
A4
VSS
M
VDD
A3
(x4)
(x8)
7
8
9
A
VDD
DQ0
VDDQ
DQ13
B
DQ2
VSSQ
DQ1
VSSQ
DQ11
C
DQ4
VDDQ
DQ3
DQ10
VDDQ
DQ9
D
DQ6
VSSQ
DQ5
DQ8
VSSQ
UDQS
E
LDQS
VDDQ
DQ7
VREF
VSS
UDM
F
LDM
VDD
NC/A13
CK
CK
G
WE
CAS
H
RAS
CS
1
2
3
VSSQ
DQ15
VSS
DQ14
VDDQ
DQ12
NC/A12 CKE
4
5
6
A11
A9
J
BA1
BA0
A8
A7
K
A0
A10/AP
A6
A5
L
A2
A1
A4
VSS
M
VDD
A3
(x16)
Figure 1
Data Sheet
MPPD0060
Pin Configuration P-TFBGA-60-9 Top View, see the balls throught the package
15
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
64 Mb x 4
32 Mb x 8
16 Mb x 16
V DD
V DD
V DD
1
66
V SS
V SS
V SS
N.C.
DQ0
DQ0
2
65
DQ15
DQ7
N.C.
V DDQ
V DDQ
V DDQ
3
64
V SSQ
V SSQ
V SSQ
N.C.
N.C.
DQ1
4
63
DQ14
N.C.
N.C.
DQ0
DQ1
DQ2
5
62
DQ13
DQ6
DQ3
V SSQ
V SSQ
V SSQ
6
61
V DDQ
V DDQ
V DDQ
N.C.
N.C.
DQ3
7
60
DQ12
N.C.
N.C.
N.C.
DQ2
DQ4
8
59
DQ11
DQ5
N.C.
V DDQ
V DDQ
V DDQ
9
58
V SSQ
V SSQ
V SSQ
N.C.
N.C.
DQ5
10
57
DQ10
N.C.
N.C.
DQ1
DQ3
DQ6
11
56
DQ9
DQ4
DQ2
V SSQ
V SSQ
V SSQ
12
55
V DDQ
V DDQ
V DDQ
N.C.
N.C.
DQ7
13
54
DQ8
N.C.
N.C.
N.C.
N.C.
N.C.
14
53
N.C.
N.C.
N.C.
V DDQ
V DDQ
V DDQ
15
52
V SSQ
V SSQ
V SSQ
N.C.
N.C.
LDQS
16
51
UDQS
DQS
DQS
A13/N.C. A13/N.C. A13/N.C.
17
50
N.C.
N.C.
N.C.
V DD
V DD
V DD
18
49
V REF
V REF
V REF
N.C.
N.C.
N.C.
19
48
V SS
V SS
V SS
N.C.
N.C.
LDM
20
47
UDM
DM
DM
WE
WE
WE
21
46
CK
CK
CK
CAS
CAS
CAS
22
45
CK
CK
CK
RAS
RAS
RAS
23
44
CKE
CKE
CKE
N.C.
N.C.
CS
CS
CS
24
43
N.C.
N.C.
N.C.
N.C.
25
42
A12/N.C. A12/N.C. A12/N.C.
BA0
BA0
BA0
26
41
A11
A11
A11
BA1
BA1
BA1
27
40
A9
A9
A9
A10/AP
A10/AP
A10/AP
28
39
A8
A8
A8
A0
A0
A0
29
38
A7
A7
A7
A1
A1
A1
30
37
A6
A6
A6
A2
A2
A2
31
36
A5
A5
A5
A3
A3
A3
32
35
A4
A4
A4
V DD
V DD
V DD
33
34
V SS
V SS
V SS
MPPD0070
Figure 2
Data Sheet
Pin Configuration P-TSOPII-66-1
16
Rev. 1.0, 2004-04
Figure 3
Data Sheet
14
14
9
Row-Address MUX
17
2
Refresh Counter
1
8
Bank0
Row-Address Latch
& Decoder
2
12
12
COL0
4096
Bank2
32
Bank3
256 (x32)
Column
Column
Decoder
Column
Decoder
Column
Decoder
Decoder
I/O Gating
DM Mask Logic
8192
Sense Amplifier
Bank0
Memory
Array
(4096 x 256 x 32)
Bank1
Write
FIFO
&
Drivers
16
16
CK, CK
32
32
Read Latch
Column-Address
Counter/Latch
12
Mode
Registers
Command
Decode
Control Logic
32
Data
2
Mask
COL0
MUX
16
16
COL0
16
1
16
1
Input
Register
1
1
2
16
2
DQS
1
Data
DQS
Generator
16
DLL
LDQS,
UDQS
DQ0DQ15,
LDM,
UDM
SPB04303
CK, CK
Drivers
A0 - A11,
BA0, BA1
CS
WE
CAS
RAS
CKE
CK
CK
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Receivers
Bank Control Logic
Address Register
Block Diagram 128Mbit ×16 Mbit ×16
Rev. 1.0, 2004-04
Figure 4
Data Sheet
14
14
10
Row-Address MUX
18
2
Refresh Counter
1
9
Bank0
Row-Address Latch
& Decoder
2
12
12
COL0
4096
Bank2
16
Bank3
512 (x16)
Column
Column
Decoder
Column
Decoder
Column
Decoder
Decoder
I/O Gating
DM Mask Logic
8192
Sense Amplifier
Bank0
Memory
Array
(4096 x 512 x 16)
Bank1
8
8
Write
FIFO
&
Drivers
CK, CK
16
16
Read Latch
Column-Address
Counter/Latch
12
Mode
Registers
Command
Decode
Control Logic
16
Data
2
Mask
COL0
MUX
8
8
COL0
8
1
8
1
Input
Register
1
1
1
8
1
DQS
1
Data
DQS
Generator
8
DLL
CK, CK
Drivers
A0 - A11,
BA0, BA1
CS
WE
CAS
RAS
CKE
CK
CK
SPB04302
DQS
DQ0DQ7,
DM
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Receivers
Bank Control Logic
Address Register
Block Diagram 128Mbit ×32 Mbit ×8
Rev. 1.0, 2004-04
Figure 5
Data Sheet
14
14
11
Row-Address MUX
19
2
Refresh Counter
1
10
Bank0
Row-Address Latch
& Decoder
2
12
12
COL0
4096
Bank2
8
Bank3
1024 (x8)
Column
Column
Decoder
Column
Decoder
Column
Decoder
Decoder
I/O Gating
DM Mask Logic
8192
Sense Amplifier
Bank0
Memory
Array
(4096 x 1024 x 8)
Bank1
8
8
4
4
CK, CK
Write
FIFO
&
Drivers
Read Latch
Column-Address
Counter/Latch
12
Mode
Registers
Command
Decode
Control Logic
8
Data
2
Mask
COL0
MUX
4
4
COL0
4
1
4
1
Input
Register
1
1
1
4
1
DQS
1
Data
DQS
Generator
4
DLL
CK, CK
Drivers
A0 - A11,
BA0, BA1
CS
WE
CAS
RAS
CKE
CK
CK
SPB04301
DQS
DQ0DQ3,
DM
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Pin Configuration
Receivers
Bank Control Logic
Address Register
Block Diagram 128Mbit ×64 Mbit ×4
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3
Functional Description
The 128 Mbit Double Data Rate SDRAM is a high-speed CMOS, dynamic random-access memory containing
268,435,456 bits. The 128 Mbit Double Data Rate SDRAM is internally configured as a quad-bank DRAM.
The 128 Mbit Double Data Rate SDRAM uses a double-data-rate architecture to achieve high-speed operation.
The double-data-rate architecture is essentially a 2n prefetch architecture, with an interface designed to transfer
two data words per clock cycle at the I/O pins. A single read or write access for the 128 Mbit Double Data Rate
SDRAM consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two
corresponding n-bit wide, one-half clock cycle data transfers at the I/O pins.
Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and
continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration
of an Active command, which is then followed by a Read or Write command. The address bits registered
coincident with the Active command are used to select the bank and row to be accessed (BA0, BA1 select the
bank; A0-A11 select the row). The address bits registered coincident with the Read or Write command are used
to select the starting column location for the burst access.
Prior to normal operation, the DDR SDRAM must be initialized. The following sections provide detailed
information covering device initialization, register definition, command descriptions and device operation.
3.1
Initialization
DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than
those specified may result in undefined operation. The following criteria must be met:
No power sequencing is specified during power up or power down given the following criteria:
•
•
•
VDD and VDDQ are driven from a single power converter output
VTT meets the specification
A minimum resistance of 42 Ω limits the input current from the VTT supply into any pin and VREF tracks VDDQ/2
or the following relationship must be followed:
•
•
•
VDDQ is driven after or with VDD such that VDDQ < VDD + 0.3 V
VTT is driven after or with VDDQ such that VTT < VDDQ + 0.3 V
VREF is driven after or with VDDQ such that VREF < VDDQ + 0.3 V
The DQ and DQS outputs are in the High-Z state, where they remain until driven in normal operation (by a read
access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM
requires a 200 µs delay prior to applying an executable command.
Once the 200 µs delay has been satisfied, a Deselect or NOP command should be applied, and CKE should be
brought HIGH. Following the NOP command, a Precharge ALL command should be applied. Next a Mode
Register Set command should be issued for the Extended Mode Register, to enable the DLL, then a Mode
Register Set command should be issued for the Mode Register, to reset the DLL, and to program the operating
parameters. 200 clock cycles are required between the DLL reset and any executable command. During the
200 cycles of clock for DLL locking, a Deselect or NOP command must be applied. After the 200 clock cycles, a
Precharge ALL command should be applied, placing the device in the “all banks idle” state.
Once in the idle state, two AUTO REFRESH cycles must be performed. Additionally, a Mode Register Set
command for the Mode Register, with the reset DLL bit deactivated (i.e. to program operating parameters without
resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation.
Data Sheet
20
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.2
Mode Register Definition
The Mode Register is used to define the specific mode of operation of the DDR SDRAM. This definition includes
the selection of a burst length, a burst type, a CAS latency, and an operating mode. The Mode Register is
programmed via the Mode Register Set command (with BA0 = 0 and BA1 = 0) and retains the stored information
until it is programmed again or the device loses power (except for bit A8, which is self-clearing).
Mode Register bits A0-A2 specify the burst length, A3 specifies the type of burst (sequential or interleaved), A4A6 specify the CAS latency, and A7-A11 specify the operating mode.
The Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before
initiating the subsequent operation. Violating either of these requirements results in unspecified operation.
MR
Mode Register Definition
BA1
BA0
0
0
A11
(BA[1:0] = 00B)
A10
A9
A8
A7
A6
MODE
reg. addr
w
Field
Bits
Type1) Description
BL
[2:0]
w
A5
A4
A3
A2
A1
CL
BT
BL
w
w
w
A0
Burst Length
Number of sequential bits per DQ related to one read/write command; see Chapter 3.2.1.
Note: All other bit combinations are RESERVED.
001 2
010 4
011 8
BT
3
w
Burst Type
See Table 5 for internal address sequence of low order address bits; see Chapter 3.2.2.
0
Sequential
1
Interleaved
CL
[6:4]
w
CAS Latency
Number of full clocks from read command to first data valid window; see Chapter 3.2.3.
Note: All other bit combinations are RESERVED.
010 2
011 3
101 1.5
Note: DDR200 components only
110 2.5
MODE [12:7] w
Operating Mode
See Chapter 3.2.4.
Note: All other bit combinations are RESERVED.
000000
000010
Normal Operation without DLL Reset
Normal Operation with DLL Reset
1) w = write
3.2.1
Burst Length
Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The
burst length determines the maximum number of column locations that can be accessed for a given Read or Write
command. Burst lengths of 2, 4, or 8 locations are available for both the sequential and the interleaved burst types.
Data Sheet
21
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Reserved states should not be used, as unknown operation or incompatibility with future versions may result.
When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All
accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is
reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2-Ai when the burst
length is set to four and by A3-Ai when the burst length is set to eight (where Ai is the most significant column
address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the
starting location within the block. The programmed burst length applies to both Read and Write bursts.
3.2.2
Burst Type
Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the
burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the
burst type and the starting column address, as shown in Table 5.
Table 5
Burst
Length
Burst Definition
Starting Column Address
A2
A1
2
A0
Type = Sequential
Type = Interleaved
0
0-1
0-1
1
1-0
1-0
0
0
0-1-2-3
0-1-2-3
0
1
1-2-3-0
1-0-3-2
1
0
2-3-0-1
2-3-0-1
1
1
3-0-1-2
3-2-1-0
0
0
0
0-1-2-3-4-5-6-7
0-1-2-3-4-5-6-7
0
0
1
1-2-3-4-5-6-7-0
1-0-3-2-5-4-7-6
0
1
0
2-3-4-5-6-7-0-1
2-3-0-1-6-7-4-5
0
1
1
3-4-5-6-7-0-1-2
3-2-1-0-7-6-5-4
1
0
0
4-5-6-7-0-1-2-3
4-5-6-7-0-1-2-3
1
0
1
5-6-7-0-1-2-3-4
5-4-7-6-1-0-3-2
1
1
0
6-7-0-1-2-3-4-5
6-7-4-5-2-3-0-1
1
1
1
7-0-1-2-3-4-5-6
7-6-5-4-3-2-1-0
4
8
Order of Accesses Within a Burst
Notes
1. For a burst length of two, A1-Ai selects the two-data-element block; A0 selects the first access within the block.
2. For a burst length of four, A2-Ai selects the four-data-element block; A0-A1 selects the first access within the
block.
3. For a burst length of eight, A3-Ai selects the eight-data- element block; A0-A2 selects the first access within
the block.
4. Whenever a boundary of the block is reached within a given sequence above, the following access wraps
within the block.
3.2.3
Read Latency
The Read latency, or CAS latency, is the delay, in clock cycles, between the registration of a Read command and
the availability of the first burst of output data. The latency can be programmed 2, 2.5 and 3 clocks. CAS latency
of 1.5 is supported for DDR200 components only.
If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally
coincident with clock edge n + m (see Figure 6).
Reserved states should not be used as unknown operation or incompatibility with future versions may result.
Data Sheet
22
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.2.4
Operating Mode
The normal operating mode is selected by issuing a Mode Register Set Command with bits A7-A11 set to zero,
and bits A0-A6 set to the desired values. A DLL reset is initiated by issuing a Mode Register Set command with
bits A7 and A9-A11 each set to zero, bit A8 set to one, and bits A0-A6 set to the desired values. A Mode Register
Set command issued to reset the DLL should always be followed by a Mode Register Set command to select
normal operating mode.
All other combinations of values for A7-A11 are reserved for future use and/or test modes. Test modes and
reserved states should not be used as unknown operation or incompatibility with future versions may result.
CAS Latency = 2, BL = 4
CK
CK
Command
Read
NOP
NOP
NOP
NOP
NOP
CL=2
DQS
DQ
CAS Latency = 2.5, BL = 4
CK
CK
Command
Read
NOP
NOP
NOP
NOP
NOP
CL=2.5
DQS
DQ
Don’t Care
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 6
Data Sheet
Required CAS Latencies
23
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.3
Extended Mode Register
The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional
functions include DLL enable/disable, and output drive strength selection (optional). These functions are controlled
via the bits shown in the Extended Mode Register Definition. The Extended Mode Register is programmed via the
Mode Register Set command (with BA0 = 1 and BA1 = 0) and retains the stored information until it is programmed
again or the device loses power. The Extended Mode Register must be loaded when all banks are idle, and the
controller must wait the specified time before initiating any subsequent operation. Violating either of these
requirements result in unspecified operation.
EMR
Extended Mode Register Definition
BA1
BA0
0
1
A11
A10
A9
(BA[1:0] = 01B)
A8
A7
A6
A5
A4
A3
MODE
reg. addr
w
Field
Bits
Type1)
Description
DLL
0
w
DLL Status
See Chapter 3.3.1.
0
Enabled
1
Disabled
DS
1
w
Drive Strength
See Chapter 3.3.2, Chapter 4.1 and Chapter 4.2.
0
Normal
1
Weak
MODE
[12:2]
w
Operating Mode
A2
A1
A0
DS
DLL
w
w
Note: All other bit combinations are RESERVED.
00000000000Normal Operation
1) w = write
3.3.1
DLL Enable/Disable
The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon
returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is
automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self
refresh operation. Any time the DLL is enabled, 200 clock cycles must occur before a Read command can be
issued. This is the reason 200 clock cycles must occur before issuing a Read or Write command upon exit of self
refresh operation.
3.3.2
Output Drive Strength
The normal drive strength for all outputs is specified to be SSTL_2, Class II. In addition this design version
supports a weak driver mode for lighter load and/or point-to-point environments which can be activated during
mode register set. I-V curves for the normal and weak drive strength are included in this document.
Data Sheet
24
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.4
Commands
Deselect
The Deselect function prevents new commands from being executed by the DDR SDRAM. The DDR SDRAM is
effectively deselected. Operations already in progress are not affected.
No Operation (NOP)
The No Operation (NOP) command is used to perform a NOP to a DDR SDRAM. This prevents unwanted
commands from being registered during idle or wait states. Operations already in progress are not affected.
Mode Register Set
The mode registers are loaded via inputs A0-A11, BA0 and BA1. See mode register descriptions in Chapter 3.2.
The Mode Register Set command can only be issued when all banks are idle and no bursts are in progress. A
subsequent executable command cannot be issued until tMRD is met.
Active
The Active command is used to open (or activate) a row in a particular bank for a subsequent access. The value
on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A11 selects the row. This row
remains active (or open) for accesses until a Precharge (or Read or Write with Auto Precharge) is issued to that
bank. A Precharge (or Read or Write with Auto Precharge) command must be issued and completed before
opening a different row in the same bank.
Read
The Read command is used to initiate a burst read access to an active (open) row. The value on the BA0, BA1
inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 8, j = don’t care] for x16, [i = 9,
j = don’t care] for x8 and [i = 9, j = 11] for x4) selects the starting column location. The value on input A10
determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is
precharged at the end of the Read burst; if Auto Precharge is not selected, the row remains open for subsequent
accesses.
Write
The Write command is used to initiate a burst write access to an active (open) row. The value on the BA0, BA1
inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don’t care] for x8; where
[i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto
Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Write
burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Input data appearing on
the DQs is written to the memory array subject to the DM input logic level appearing coincident with the data. If a
given DM signal is registered low, the corresponding data is written to memory; if the DM signal is registered high,
the corresponding data inputs are ignored, and a Write is not executed to that byte/column location.
Precharge
The Precharge command is used to deactivate (close) the open row in a particular bank or the open row(s) in all
banks. The bank(s) will be available for a subsequent row access a specified time (tRP) after the Precharge
command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where
only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as “Don’t
Care”. Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write
commands being issued to that bank. A precharge command is treated as a NOP if there is no open row in that
bank, or if the previously open row is already in the process of precharging.
Data Sheet
25
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Auto Precharge
Auto Precharge is a feature which performs the same individual-bank precharge functions described above, but
without requiring an explicit command. This is accomplished by using A10 to enable Auto Precharge in conjunction
with a specific Read or Write command. A precharge of the bank/row that is addressed with the Read or Write
command is automatically performed upon completion of the Read or Write burst. Auto Precharge is nonpersistent
in that it is either enabled or disabled for each individual Read or Write command. Auto Precharge ensures that
the precharge is initiated at the earliest valid stage within a burst. The user must not issue another command to
the same bank until the precharge (tRP) is completed. This is determined as if an explicit Precharge command was
issued at the earliest possible time, as described for each burst type in Chapter 3.5.
Burst Terminate
The Burst Terminate command is used to truncate read bursts (with Auto Precharge disabled). The most recently
registered Read command prior to the Burst Terminate command is truncated, as shown in Chapter 3.5.
Auto Refresh
Auto Refresh is used during normal operation of the DDR SDRAM and is analogous to CAS Before RAS (CBR)
Refresh in previous DRAM types. This command is nonpersistent, so it must be issued each time a refresh is
required.
The refresh addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care”
during an Auto Refresh command. The 128 Mbit Double Data Rate SDRAM requires Auto Refresh cycles at an
average periodic interval of 7.8 µs (maximum).
To allow for improved efficiency in scheduling and switching between tasks, some flexibility in the absolute refresh
interval is provided. A maximum of eight Auto Refresh commands can be posted in the system, meaning that the
maximum absolute interval between any Auto Refresh command and the next Auto Refresh command is
9 × 7.8 µs (70.2 µs). This maximum absolute interval is short enough to allow for DLL updates internal to the
DDR SDRAM to be restricted to Auto Refresh cycles, without allowing too much drift in tAC between updates.
Self Refresh
The Self Refresh command can be used to retain data in the DDR SDRAM, even if the rest of the system is
powered down. When in the self refresh mode, the DDR SDRAM retains data without external clocking. The Self
Refresh command is initiated as an Auto Refresh command coincident with CKE transitioning low. The DLL is
automatically disabled upon entering Self Refresh, and is automatically enabled upon exiting Self Refresh
(200 clock cycles must then occur before a Read command can be issued). Input signals except CKE (low) are
“Don’t Care” during Self Refresh operation.
The procedure for exiting self refresh requires a sequence of commands. CK (and CK) must be stable prior to CKE
returning high. Once CKE is high, the SDRAM must have NOP commands issued for tXSNR because time is
required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh and
DLL requirements is to apply NOPs for 200 clock cycles before applying any other command.
Data Sheet
26
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Table 6
Truth Table 1a: Commands
Name (Function)
CS
RAS CAS WE Address
MNE
Notes
Deselect (NOP)
H
X
X
X
X
NOP
1)2)
No Operation (NOP)
L
H
H
H
X
NOP
1)2)
Active (Select Bank And Activate Row)
L
L
H
H
Bank/Row ACT
1)3)
Read (Select Bank And Column, And Start Read Burst)
L
H
L
H
Bank/Col
Read
1)4)
Write (Select Bank And Column, And Start Write Burst)
L
H
L
L
Bank/Col
Write
1)4)
Burst Terminate
L
H
H
L
X
BST
1)5)
Precharge (Deactivate Row In Bank Or Banks)
L
L
H
L
Code
PRE
1)6)
Auto Refresh Or Self Refresh (Enter Self Refresh Mode)
L
L
L
H
X
AR/SR
1)7)8)
Mode Register Set
L
L
L
L
Op-Code
MRS
1)9)
1) CKE is HIGH for all commands shown except Self Refresh.
2) Deselect and NOP are functionally interchangeable.
3) BA0-BA1 provide bank address and A0-A11 provide row address.
4) BA0, BA1 provide bank address; A0-Ai provide column address (where i = 8 for x16, i = 9 for x8 and 9, 11 for x4);
A10 HIGH enables the Auto Precharge feature (nonpersistent), A10 LOW disables the Auto Precharge feature.
5) Applies only to read bursts with Auto Precharge disabled; this command is undefined (and should not be used) for read
bursts with Auto Precharge enabled or for write bursts.
6) A10 LOW: BA0, BA1 determine which bank is precharged.
A10 HIGH: all banks are precharged and BA0, BA1 are “Don’t Care”.
7) This command is Auto Refresh if CKE is HIGH; Self Refresh if CKE is LOW.
8) Internal refresh counter controls row and bank addressing; all inputs and I/Os are “Don’t Care” except for CKE.
9) BA0, BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0 = 1,
BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A11 provide the op-code to
be written to the selected Mode Register).
Table 7
Truth Table 1b: DM Operation
Name (Function)
DM
DQs
Notes
Write Enable
L
Valid
1)
Write Inhibit
H
X
1)
1) Used to mask write data; provided coincident with the corresponding data.
Data Sheet
27
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.5
Operations
3.5.1
Bank/Row Activation
Before any Read or Write commands can be issued to a bank within the DDR SDRAM, a row in that bank must
be “opened” (activated). This is accomplished via the Active command and addresses A0-A11, BA0 and BA1 (see
Figure 7), which decode and select both the bank and the row to be activated. After opening a row (issuing an
Active command), a Read or Write command may be issued to that row, subject to the tRCD specification. A
subsequent Active command to a different row in the same bank can only be issued after the previous active row
has been “closed” (precharged). The minimum time interval between successive Active commands to the same
bank is defined by tRC. A subsequent Active command to another bank can be issued while the first bank is being
accessed, which results in a reduction of total row-access overhead. The minimum time interval between
successive Active commands to different banks is defined by tRRD.
CK
CK
HIGH
CKE
CS
RAS
CAS
WE
Figure 7
A0-A11
RA
BA0, BA1
BA
RA = row address.
BA = bank address.
Don’t Care
Activating a Specific Row in a Specific Bank
CK
CK
NOP
ACT
NOP
ACT
A0-A11
ROW
ROW
COL
BA0, BA1
BA x
BA y
BA y
tRRD
NOP
RD/WR
Command
NOP
NOP
tRCD
Don’t Care
Figure 8
Data Sheet
tRCD and tRRD Definition
28
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.5.2
Reads
Subsequent to programming the mode register with CAS latency, burst type, and burst length, Read bursts are
initiated with a Read command, as shown on Figure 9.
The starting column and bank addresses are provided with the Read command and Auto Precharge is either
enabled or disabled for that burst access. If Auto Precharge is enabled, the row that is accessed starts precharge
at the completion of the burst, provided tRAS has been satisfied. For the generic Read commands used in the
following illustrations, Auto Precharge is disabled.
During Read bursts, the valid data-out element from the starting column address is available following the CAS
latency after the Read command. Each subsequent data-out element is valid nominally at the next positive or
negative clock edge (i.e. at the next crossing of CK and CK). Figure 10 shows general timing for each supported
CAS latency setting. DQS is driven by the DDR SDRAM along with output data. The initial low state on DQS is
known as the read preamble; the low state coincident with the last data-out element is known as the read
postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs goes High-Z.
Data from any Read burst may be concatenated with or truncated with data from a subsequent Read command.
In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either
the last element of a completed burst or the last desired data element of a longer burst which is being truncated.
The new Read command should be issued x cycles after the first Read command, where x equals the number of
desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown on Figure 11. A
Read command can be initiated on any clock cycle following a previous Read command. Nonconsecutive Read
data is illustrated on Figure 12. Full-speed Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8)
within a page (or pages) can be performed as shown on Figure 13.
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
x4: A0-A9, A11
x8: A0-A9
x16: A0-A8
CA
EN AP
A10
DIS AP
BA0, BA1
CA = column address
BA = bank address
EN AP = enable Auto Precharge
DIS AP = disable Auto Precharge
BA
Don’t Care
Figure 9
Data Sheet
Read Command
29
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Address
Read
NOP
NOP
NOP
NOP
NOP
BA a,COL n
CL=2
DQS
DOa-n
DQ
CAS Latency = 2.5
CK
CK
Command
Address
Read
NOP
NOP
NOP
NOP
NOP
BA a,COL n
CL=2.5
DQS
DOa-n
DQ
DO a-n = data out from bank a, column n.
3 subsequent elements of data out appear in the programmed order following DO a-n.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 10
Data Sheet
Don’t Care
Read Burst: CAS Latencies (Burst Length = 4)
30
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Address
Read
NOP
Read
BAa, COL n
NOP
NOP
NOP
BAa, COL b
CL=2
DQS
DQ
DOa-b
DOa-n
CAS Latency = 2.5
CK
CK
Command
Address
Read
NOP
Read
BAa, COL n
NOP
NOP
NOP
BAa,COL b
CL=2.5
DQS
DOa- n
DQ
DO a-n (or a-b) = data out from bank a, column n (or bank a, column b).
When burst length = 4, the bursts are concatenated.
When burst length = 8, the second burst interrupts the first.
3 subsequent elements of data out appear in the programmed order following DO a-n.
3 (or 7) subsequent elements of data out appear in the programmed order following DO a-b.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 11
Data Sheet
DOa- b
Don’t Care
Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8)
31
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Read
Command
Address
NOP
NOP
Read
BAa, COL n
NOP
NOP
BAa, COL b
CL=2
DQS
DO a-n
DQ
DOa- b
CAS Latency = 2.5
CK
CK
Command
Address
Read
NOP
NOP
Read
BAa, COL n
NOP
NOP
NOP
BAa, COL b
CL=2.5
DQS
DQ
DO a-n
DO a-n (or a-b) = data out from bank a, column n (or bank a, column b).
3 subsequent elements of data out appear in the programmed order following DO a-n (and following DO a-b).
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 12
Data Sheet
DOa- b
Don’t Care
Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4)
32
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Address
Read
Read
Read
Read
NOP
BAa, COL n
BAa, COL x
BAa, COL b
BAa, COL g
NOP
CL=2
DQS
DQ
DOa-n
DOa-n’
DOa-x
DOa-x’
DOa-b
DOa-b’
DOa-g
CAS Latency = 2.5
CK
CK
Command
Address
Read
Read
Read
Read
BAa, COL n
BAa, COL x
BAa, COL b
BAa, COL g
NOP
NOP
CL=2.5
DQS
DQ
DOa-n
DOa-n’
DOa-x
DO a-n, etc. = data out from bank a, column n etc.
n' etc. = odd or even complement of n, etc. (i.e., column address LSB inverted).
Reads are to active rows in any banks.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 13
Data Sheet
DOa-x’
DOa-b
DOa-b’
Don’t Care
Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8)
33
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Data from any Read burst may be truncated with a Burst Terminate command, as shown on Figure 14. The Burst
Terminate latency is equal to the read (CAS) latency, i.e. the Burst Terminate command should be issued x cycles
after the Read command, where x equals the number of desired data element pairs.
Data from any Read burst must be completed or truncated before a subsequent Write command can be issued. If
truncation is necessary, the Burst Terminate command must be used, as shown on Figure 15. The example is
shown for tDQSS(min). The tDQSS(max) case, not shown here, has a longer bus idle time. tDQSS(min) and tDQSS(max) are
defined in Chapter 3.5.3.
A Read burst may be followed by, or truncated with, a Precharge command to the same bank (provided that Auto
Precharge was not activated). The Precharge command should be issued x cycles after the Read command,
where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This
is shown on Figure 16 for Read latencies of 2 and 2.5. Following the Precharge command, a subsequent
command to the same bank cannot be issued until tRP is met. Note that part of the row precharge time is hidden
during the access of the last data elements.
In the case of a Read being executed to completion, a Precharge command issued at the optimum time (as
described above) provides the same operation that would result from the same Read burst with Auto Precharge
enabled. The disadvantage of the Precharge command is that it requires that the command and address busses
be available at the appropriate time to issue the command. The advantage of the Precharge command is that it
can be used to truncate bursts.
Data Sheet
34
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Address
Read
NOP
BST
NOP
NOP
NOP
BAa, COL n
CL=2
DQS
DQ
DOa-n
No further output data after this point.
DQS tristated.
CAS Latency = 2.5
CK
CK
Command
Address
Read
NOP
BST
NOP
NOP
NOP
BAa, COL n
CL=2.5
DQS
DQ
DOa-n
No further output data after this point.
DQS tristated.
DO a-n = data out from bank a, column n.
Cases shown are bursts of 8 terminated after 4 data elements.
3 subsequent elements of data out appear in the programmed order following DO a-n.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 14
Data Sheet
Don’t Care
Terminating a Read Burst: CAS Latencies (Burst Length = 8)
35
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Address
Read
BST
NOP
BAa, COL n
Write
NOP
NOP
BAa, COL b
CL=2
tDQSS (min)
DQS
DQ
DI a-b
DOa-n
DM
CAS Latency = 2.5
CK
CK
Command
Address
Read
BST
NOP
NOP
BAa, COL n
Write
NOP
BAa, COL b
CL=2.5
tDQSS (min)
DQS
DOa-n
DQ
Dla-b
DM
DO a-n = data out from bank a, column n
.DI a-b = data in to bank a, column b
1 subsequent elements of data out appear in the programmed order following DO a-n.
Data In elements are applied following Dl a-b in the programmed order, according to burst length.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 15
Data Sheet
Don’t Care
Read to Write: CAS Latencies (Burst Length = 4 or 8)
36
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CAS Latency = 2
CK
CK
Command
Read
NOP
PRE
NOP
NOP
ACT
tRP
Address
BA a or all
BA a, COL n
BA a, ROW
CL=2
DQS
DQ
DOa-n
CAS Latency = 2.5
CK
CK
Command
Read
NOP
PRE
NOP
NOP
ACT
tRP
Address
BA a or all
BA a, COL n
BA a, ROW
CL=2.5
DQS
DQ
DOa-n
DO a-n = data out from bank a, column n.
Cases shown are either uninterrupted bursts of 4 or interrupted bursts of 8.
3 subsequent elements of data out appear in the programmed order following DO a-n.
Shown with nominal tAC, tDQSCK, and tDQSQ.
Figure 16
Data Sheet
Don’t Care
Read to Precharge: CAS Latencies (Burst Length = 4 or 8)
37
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.5.3
Writes
Write bursts are initiated with a Write command, as shown in Figure 17.
The starting column and bank addresses are provided with the Write command, and Auto Precharge is either
enabled or disabled for that access. If Auto Precharge is enabled, the row being accessed is precharged at the
completion of the burst. For the generic Write commands used in the following illustrations, Auto Precharge is
disabled.
During Write bursts, the first valid data-in element is registered on the first rising edge of DQS following the write
command, and subsequent data elements are registered on successive edges of DQS. The Low state on DQS
between the Write command and the first rising edge is known as the write preamble; the Low state on DQS
following the last data-in element is known as the write postamble. The time between the Write command and the
first corresponding rising edge of DQS (tDQSS) is specified with a relatively wide range (from 75% to 125% of one
clock cycle), so most of the Write diagrams that follow are drawn for the two extreme cases (i.e. tDQSS(min) and
tDQSS(max)). Figure 18 shows the two extremes of tDQSS for a burst of four. Upon completion of a burst, assuming
no other commands have been initiated, the DQs and DQS enters High-Z and any additional input data is ignored.
Data for any Write burst may be concatenated with or truncated with a subsequent Write command. In either case,
a continuous flow of input data can be maintained. The new Write command can be issued on any positive edge
of clock following the previous Write command. The first data element from the new burst is applied after either
the last element of a completed burst or the last desired data element of a longer burst which is being truncated.
The new Write command should be issued x cycles after the first Write command, where x equals the number of
desired data element pairs (pairs are required by the 2n prefetch architecture). Figure 19 shows concatenated
bursts of 4. An example of non-consecutive Writes is shown in Figure 20. Full-speed random write accesses
within a page or pages can be performed as shown in Figure 21. Data for any Write burst may be followed by a
subsequent Read command. To follow a Write without truncating the write burst, tWTR (Write to Read) should be
met as shown in Figure 22.
Data for any Write burst may be truncated by a subsequent Read command, as shown in Figure 23 to Figure 25.
Note that only the data-in pairs that are registered prior to the tWTR period are written to the internal array, and any
subsequent data-in must be masked with DM, as shown in the diagrams noted previously.
Data for any Write burst may be followed by a subsequent Precharge command. To follow a Write without
truncating the write burst, tWR should be met as shown in Figure 26.
Data for any Write burst may be truncated by a subsequent Precharge command, as shown in Figure 27 to
Figure 29. Note that only the data-in pairs that are registered prior to the tWR period are written to the internal array,
and any subsequent data in should be masked with DM. Following the Precharge command, a subsequent
command to the same bank cannot be issued until tRP is met.
In the case of a Write burst being executed to completion, a Precharge command issued at the optimum time (as
described above) provides the same operation that would result from the same burst with Auto Precharge. The
disadvantage of the Precharge command is that it requires that the command and address busses be available at
the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to
truncate bursts.
Data Sheet
38
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
x4: A0-A9, A11
x8: A0-A9
x16: A0-A8
CA
EN AP
A10
DIS AP
BA0, BA1
CA = column address
BA = bank address
EN AP = enable Auto Precharge
DIS AP = disable Auto Precharge
BA
Don’t Care
Figure 17
Data Sheet
Write Command
39
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
CK
CK
Command
Address
Write
NOP
NOP
NOP
BA a, COL b
tDQSS (max)
DQS
Dla-b
DQ
DM
Minimum DQSS
T1
T2
T3
T4
CK
CK
Command
Address
Write
NOP
NOP
NOP
BA a, COL b
tDQSS (min)
DQS
Dla-b
DQ
DM
DI a-b = data in for bank a, column b.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
A non-interrupted burst is shown.
A10 is Low with the Write command (Auto Precharge is disabled).
Don’t Care
Figure 18
Data Sheet
Write Burst (Burst Length = 4)
40
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Address
Write
NOP
Write
BAa, COL b
NOP
NOP
NOP
BAa, COL n
tDQSS (max)
DQS
DI a-b
DQ
DI a-n
DM
Minimum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Address
Write
NOP
BA, COL b
Write
NOP
NOP
NOP
BA, COL n
tDQSS (min)
DQS
DQ
DI a-b
DI a-n
DM
DI a-b = data in for bank a, column b, etc.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
3 subsequent elements of data in are applied in the programmed order following DI a-n.
A non-interrupted burst is shown.
Each Write command may be to any bank.
Figure 19
Data Sheet
Don’t Care
Write to Write (Burst Length = 4)
41
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
T1
T2
T3
T4
T5
CK
CK
Command
Address
Write
NOP
NOP
BAa, COL b
Write
NOP
BAa, COL n
tDQSS (max)
DQS
DQ
DI a-b
DI a-n
DM
DI a-b, etc. = data in for bank a, column b, etc.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
3 subsequent elements of data in are applied in the programmed order following DI a-n.
A non-interrupted burst is shown.
Each Write command may be to any bank.
Figure 20
Data Sheet
Don’t Care
Write to Write: Max. DQSS, Non-Consecutive (Burst Length = 4)
42
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
CK
CK
Command
Address
Write
Write
BAa, COL b
Write
BAa, COL x
Write
BAa, COL n
Write
BAa, COL a
BAa, COL g
tDQSS (max)
DQS
DQ
DI a-b
DI a-b’
DI a-x
DI a-x’
DI a-n
DI a-n’
DI a-a
DI a-a’
DM
Minimum DQSS
T1
T2
T3
T4
T5
CK
CK
Command
Address
Write
Write
BAa, COL b
Write
BAa, COL x
Write
BAa, COL n
Write
BAa, COL a
BAa, COL g
tDQSS (min)
DQS
DQ
DI a-b
DI a-b’
DI a-x
DI a-x’
DI a-n
DI a-n’
DI a-a
DI a-a’
DI a-g
DM
DI a-b, etc. = data in for bank a, column b, etc.
b', etc. = odd or even complement of b, etc. (i.e., column address LSB inverted).
Each Write command may be to any bank.
Figure 21
Data Sheet
Don’t Care
Random Write Cycles (Burst Length = 2, 4 or 8)
43
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL b
BAa, COL n
CL = 2
tDQSS (max)
DQS
DQ
DI a-b
DM
Minimum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL n
BAa, COL b
CL = 2
tDQSS (min)
DQS
DQ
DI a-b
DM
DI a-b = data in for bank a, column b.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
A non-interrupted burst is shown.
tWTR is referenced from the first positive CK edge after the last data in pair.
A10 is Low with the Write command (Auto Precharge is disabled).
The Read and Write commands may be to any bank.
Figure 22
Data Sheet
Don’t Care
Write to Read: Non-Interrupting (CAS Latency = 2; Burst Length = 4)
44
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL n
BAa, COL b
CL = 2
tDQSS (max)
DQS
DQ
DIa- b
1
DM
1
Minimum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL n
BAa, COL b
CL = 2
tDQSS (min)
DQS
DQ
DI a-b
1
DM
1
DI a-b = data in for bank a, column b.
An interrupted burst is shown, 4 data elements are written.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
tWTR is referenced from the first positive CK edge after the last data in pair.
The Read command masks the last 2 data elements in the burst.
A10 is Low with the Write command (Auto Precharge is disabled).
The Read and Write commands are not necessarily to the same bank.
1 = These bits are incorrectly written into the memory array if DM is low.
Figure 23
Data Sheet
Don’t Care
Write to Read: Interrupting (CAS Latency = 2; Burst Length = 8)
45
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL n
BAa, COL b
CL = 2
tDQSS (min)
DQS
DQ
DI a-b
1
DM
2
2
DI a-b = data in for bank a, column b.
An interrupted burst is shown, 3 data elements are written.
2 subsequent elements of data in are applied in the programmed order following DI a-b.
tWTR is referenced from the first positive CK edge after the last desired data in pair (not the last desired data in element)
The Read command masks the last 2 data elements in the burst.
A10 is Low with the Write command (Auto Precharge is disabled).
The Read and Write commands are not necessarily to the same bank.
1 = This bit is correctly written into the memory array if DM is low.
Don’t Care
2 = These bits are incorrectly written into the memory array if DM is low.
Figure 24
Data Sheet
Write to Read: Min. DQSS, Odd Number of Data (3-bit Write), Interrupting (CL2; BL8)
46
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
Read
NOP
tWTR
Address
BAa, COL n
BAa, COL b
CL = 2
tDQSS (nom)
DQS
DQ
DI a-b
DM
1
1
DI a-b = data in for bank a, column b.
An interrupted burst is shown, 4 data elements are written.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
tWTR is referenced from the first positive CK edge after the last desired data in pair.
The Read command masks the last 2 data elements in the burst.
A10 is Low with the Write command (Auto Precharge is disabled).
The Read and Write commands are not necessarily to the same bank.
1 = These bits are incorrectly written into the memory array if DM is low.
Figure 25
Data Sheet
Don’t Care
Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8)
47
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
NOP
PRE
tWR
Address
BA (a or all)
BA a, COL b
tRP
tDQSS (max)
DQS
DQ
DI a-b
DM
Minimum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
NOP
PRE
tWR
Address
BA (a or all)
BA a, COL b
tRP
tDQSS (min)
DQS
DQ
DI a-b
DM
DI a-b = data in for bank a, column b.
3 subsequent elements of data in are applied in the programmed order following DI a-b.
A non-interrupted burst is shown.
tWR is referenced from the first positive CK edge after the last data in pair.
A10 is Low with the Write command (Auto Precharge is disabled).
Figure 26
Data Sheet
Don’t Care
Write to Precharge: Non-Interrupting (Burst Length = 4)
48
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Maximum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
PRE
NOP
tWR
Address
BA (a or all)
BA a, COL b
tDQSS (max)
tRP
2
DQS
DQ
DI a-b
3
DM
1
3
1
Minimum DQSS
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
PRE
NOP
tWR
Address
BA a, COL b
BA (a or all)
tDQSS (min)
tRP
2
DQS
DQ
DM
DI a-b
3
3
1
1
DI a-b = data in for bank a, column b.
An interrupted burst is shown, 2 data elements are written.
1 subsequent element of data in is applied in the programmed order following DI a-b.
tWR is referenced from the first positive CK edge after the last desired data in pair.
The Precharge command masks the last 2 data elements in the burst, for burst length = 8.
A10 is Low with the Write command (Auto Precharge is disabled).
1 = Can be don't care for programmed burst length of 4.
2 = For programmed burst length of 4, DQS becomes don't care at this point.
3 = These bits are incorrectly written into the memory array if DM is low.
Figure 27
Data Sheet
Don’t Care
Write to Precharge: Interrupting (Burst Length = 4 or 8)
49
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
PRE
NOP
tWR
Address
BA (a or all)
BA a, COL b
tDQSS (min)
tRP
2
DQS
DQ
DM
DI a-b
3
4
4
1
1
DI a-b = data in for bank a, column b.
An interrupted burst is shown, 1 data element is written.
tWR is referenced from the first positive CK edge after the last desired data in pair.
The Precharge command masks the last 2 data elements in the burst.
A10 is Low with the Write command (Auto Precharge is disabled).
1 = Can be don't care for programmed burst length of 4.
2 = For programmed burst length of 4, DQS becomes don't care at this point.
3 = This bit is correctly written into the memory array if DM is low.
4 = These bits are incorrectly written into the memory array if DM is low.
Figure 28
Data Sheet
Don’t Care
Write to Precharge: Minimum DQSS, Odd Number of Data (1-bit Write), Interrupting (BL 4 or 8)
50
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
T1
T2
T3
T4
T5
T6
CK
CK
Command
Write
NOP
NOP
NOP
PRE
NOP
tWR
Address
BA a, COL b
BA (a or all)
tDQSS (nom)
tRP
2
DQS
DQ
DM
DI a-b
3
3
1
1
DI a-b = Data In for bank a, column b.
An interrupted burst is shown, 2 data elements are written.
1 subsequent element of data in is applied in the programmed order following DI a-b.
tWR is referenced from the first positive CK edge after the last desired data in pair.
The Precharge command masks the last 2 data elements in the burst.
A10 is Low with the Write command (Auto Precharge is disabled).
1 = Can be don't care for programmed burst length of 4.
2 = For programmed burst length of 4, DQS becomes don't care at this point.
3 = These bits are incorrectly written into the memory array if DM is low.
Figure 29
Data Sheet
Don’t Care
Write to Precharge: Nominal DQSS (2-bit Write), Interrupting (Burst Length = 4 or 8)
51
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.5.4
Precharge
The Precharge command is used to deactivate the open row in a particular bank or the open row in all banks. The
bank(s) will be available for a subsequent row access some specified time (tRP) after the Precharge command is
issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank
is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are
treated as “Don’t Care”. Once a bank has been precharged, it is in the idle state and must be activated prior to any
Read or Write commands being issued to that bank.
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
A0-A9, A11, A11128
All Banks
A10
BA0, BA1
One Bank
BA
BA = bank address
(if A10 is Low, otherwise Don’t Care).
Don’t Care
Figure 30
Data Sheet
Precharge Command
52
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.5.5
Power-Down
Power-down is entered when CKE is registered LOW (no accesses can be in progress). If power-down occurs
when all banks are idle, this mode is referred to as precharge power-down; if power-down occurs when there is a
row active in any bank, this mode is referred to as active power-down. Entering power-down deactivates the input
and output buffers, excluding CK, CK and CKE. The DLL is still running in Power Down mode, so for maximum
power savings, the user has the option of disabling the DLL prior to entering Power-down. In that case, the DLL
must be enabled after exiting power-down, and 200 clock cycles must occur before a Read command can be
issued. In power-down mode, CKE Low and a stable clock signal must be maintained at the inputs of the
DDR SDRAM, and all other input signals are “Don’t Care”. However, power-down duration is limited by the refresh
requirements of the device, so in most applications, the self refresh mode is preferred over the DLL-disabled
power-down mode.
The power-down state is synchronously exited when CKE is registered HIGH (along with a NOP or Deselect
command). A valid, executable command may be applied one clock cycle later.
CK
CK
tIS
CKE
Command
VALID
tIS
NOP
NOP
No column
access in
progress
Exit
power down
mode
Enter Power Down mode
(Burst Read or Write operation
must not be in progress)
Figure 31
Data Sheet
VALID
Don’t Care
Power Down
53
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Table 8
Truth Table 2: Clock Enable (CKE)
Current State CKE n-1
Self Refresh
CKEn
Previous
Cycle
Current
Cycle
L
L
Command n
Action n
Notes
X
Maintain Self-Refresh
–
Self Refresh
L
H
Deselect or NOP
Exit Self-Refresh
1)
Power Down
L
L
X
Maintain Power-Down
–
Power Down
L
H
Deselect or NOP
Exit Power-Down
–
All Banks Idle
H
L
Deselect or NOP
Precharge Power-Down Entry –
All Banks Idle
H
L
AUTO REFRESH
Self Refresh Entry
–
Bank(s) Active H
L
Deselect or NOP
Active Power-Down Entry
–
H
H
See Table 9
–
–
1) Deselect or NOP commands should be issued on any clock edges occurring during the Self Refresh Exit (tXSNR) period. A
minimum of 200 clock cycles are needed before applying a read command to allow the DLL to lock to the input clock.
1.
2.
3.
4.
CKEn is the logic state of CKE at clock edge n: CKE n-1 was the state of CKE at the previous clock edge.
Current state is the state of the DDR SDRAM immediately prior to clock edge n.
COMMAND n is the command registered at clock edge n, and ACTION n is a result of COMMAND n.
All states and sequences not shown are illegal or reserved.
Table 9
Truth Table 3: Current State Bank n - Command to Bank n (same bank)
Current State CS
RAS CAS WE
Command
Action
Notes
Any
H
X
X
X
Deselect
NOP. Continue previous operation.
1)2)3)4)5)6)
L
H
H
H
No Operation
NOP. Continue previous operation.
1) to 6)
L
L
H
H
Active
Select and activate row
1) to 6)
L
L
L
H
AUTO REFRESH
–
1) to 7)
L
L
L
L
MODE
REGISTER SET
–
1) to 7)
L
H
L
H
Read
Select column and start Read burst
1) to 6), 8)
L
H
L
L
Write
Select column and start Write burst
1) to 6), 8)
L
L
H
L
Precharge
Deactivate row in bank(s)
1) to 6), 9)
L
H
L
H
Read
Select column and start new Read
burst
1) to 6), 8)
L
L
H
L
Precharge
Truncate Read burst, start
Precharge
1) to 6), 9)
L
H
H
L
BURST
TERMINATE
BURST TERMINATE
1) to 6), 10)
L
H
L
H
Read
Select column and start Read burst
1) to 6), 8), 11)
L
H
L
L
Write
Select column and start Write burst
1) to 6), 8)
L
L
H
L
Precharge
Truncate Write burst, start Precharge
1) to 6), 9), 11)
Idle
Row Active
Read (Auto
Precharge
Disabled)
Write (Auto
Precharge
Disabled)
1) This table applies when CKE n-1 was HIGH and CKE n is HIGH (see Table 8 and after tXSNR/tXSRD has been met (if the
previous state was self refresh).
2) This table is bank-specific, except where noted, i.e., the current state is for a specific bank and the commands shown are
those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below.
Data Sheet
54
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3) Current state definitions:
Idle: The bank has been precharged, and tRP has been met.
Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register
accesses are in progress.
Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated.
Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated.
4) The following states must not be interrupted by a command issued to the same bank.
Precharging: Starts with registration of a Precharge command and ends when tRP is met. Once tRP is met, the bank is in
the idle state.
Row Activating: Starts with registration of an Active command and ends when tRCD is met. Once tRCD is met, the bank is in
the “row active” state.
Read w/Auto Precharge Enabled: Starts with registration of a Read command with Auto Precharge enabled and ends when
tRP has been met. Once tRP is met, the bank is in the idle state.
Write w/Auto Precharge Enabled: Starts with registration of a Write command with Auto Precharge enabled and ends when
tRP has been met. Once tRP is met, the bank is in the idle state.
Deselect or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring
during these states. Allowable commands to the other bank are determined by its current state and according to Table 10.
5) The following states must not be interrupted by any executable command; Deselect or NOP commands must be applied
on each positive clock edge during these states.
Refreshing: Starts with registration of an Auto Refresh command and ends when tRFC is met. Once tRFC is met, the
DDR SDRAM is in the “all banks idle” state.
Accessing Mode Register: Starts with registration of a Mode Register Set command and ends when tMRD has been met.
Once tMRD is met, the DDR SDRAM is in the “all banks idle” state.
Precharging All: Starts with registration of a Precharge All command and ends when tRP is met. Once tRP is met, all banks
is in the idle state.
6) All states and sequences not shown are illegal or reserved.
7) Not bank-specific; requires that all banks are idle.
8) Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads
or Writes with Auto Precharge disabled.
9) May or may not be bank-specific; if all/any banks are to be precharged, all/any must be in a valid state for precharging.
10) Not bank-specific; BURST TERMINATE affects the most recent Read burst, regardless of bank.
11) Requires appropriate DM masking.
Data Sheet
55
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
Table 10
Truth Table 4: Current State Bank n - Command to Bank m (different bank)
Current State
CS
RAS CAS WE
Command
Action
Notes
Any
H
X
X
X
Deselect
NOP. Continue previous operation.
1)2)3)4)5)6)
L
H
H
H
No Operation
NOP. Continue previous operation.
1) to 6)
Idle
X
X
X
X
Any Command
Otherwise Allowed
to Bank m
–
1) to 6)
Row Activating,
Active, or
Precharging
L
L
H
H
Active
Select and activate row
1) to 6)
L
H
L
H
Read
Select column and start Read burst
1) to 7)
L
H
L
L
Write
Select column and start Write burst
1) to 7)
L
L
H
L
Precharge
–
1) to 6)
L
L
H
H
Active
Select and activate row
1) to 6)
L
H
L
H
Read
Select column and start new Read
burst
1) to 7)
L
L
H
L
Precharge
–
1) to 6)
L
L
H
H
Active
Select and activate row
1) to 6)
L
H
L
H
Read
Select column and start Read burst
1) to 8)
L
H
L
L
Write
Select column and start new Write
burst
1) to 7)
L
L
H
L
Precharge
–
1) to 6)
Read (With Auto L
Precharge)
L
L
H
H
Active
Select and activate row
1) to 6)
H
L
H
Read
Select column and start new Read
burst
1) to 7), 9)
L
H
L
L
Write
Select column and start Write burst
1) to 7), 9), 10)
L
L
H
L
Precharge
–
1) to 6)
Write (With Auto L
Precharge)
L
L
H
H
Active
Select and activate row
1) to 6)
H
L
H
Read
Select column and start Read burst
1) to 7), 9)
L
H
L
L
Write
Select column and start new Write
burst
1) to 7), 9)
L
L
H
L
Precharge
–
1) to 6)
Read (Auto
Precharge
Disabled)
Write (Auto
Precharge
Disabled)
1) This table applies when CKE n-1 was HIGH and CKE n is HIGH (see Table 8: Clock Enable (CKE) and after tXSNR/tXSRD
has been met (if the previous state was self refresh).
2) This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands
shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is
allowable). Exceptions are covered in the notes below.
3) Current state definitions:
Idle: The bank has been precharged, and tRP has been met.
Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register
accesses are in progress.
Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated.
Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated.
Read with Auto Precharge Enabled: See 10).
Write with Auto Precharge Enabled: See 10).
4) AUTO REFRESH and Mode Register Set commands may only be issued when all banks are idle.
5) A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state
only.
6) All states and sequences not shown are illegal or reserved.
Data Sheet
56
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
7) Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads
or Writes with Auto Precharge disabled.
8) Requires appropriate DM masking.
9) Concurrent Auto Precharge:
This device supports “Concurrent Auto Precharge”. When a read with auto precharge or a write with auto precharge is
enabled any command may follow to the other banks as long as that command does not interrupt the read or write data
transfer and all other limitations apply (e.g. contention between READ data and WRITE data must be avoided). The
minimum delay from a read or write command with auto precharge enable, to a command to a different banks is
summarized in Table 11.
10) A Write command may be applied after the completion of data output.
Table 11
Truth Table 5: Concurrent Auto Precharge
From Command
To Command (different bank)
Minimum Delay with Concurrent
Auto Precharge Support
Unit
WRITE w/AP
Read or Read w/AP
1 + (BL/2) + tWTR
Write to Write w/AP
BL/2
Precharge or Activate
1
Read or Read w/AP
BL/2
Write or Write w/AP
CL (rounded up) + BL/2
Precharge or Activate
1
tCK
tCK
tCK
tCK
tCK
tCK
Read w/AP
Data Sheet
57
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Functional Description
3.6
Simplified State Diagram
Power
Applied
Power
On
Self
Refresh
Precharge
PREALL
REFS
REFSX
MRS
EMRS
MRS
Auto
Refresh
REFA
Idle
CKEL
CKEH
Active
Power
Down
ACT
Precharge
Power
Down
CKEH
CKEL
Burst Stop
Row
Active
Write
Write A
Write
Read
Read A
Read
Read
Read A
Write A
Read
A
PRE
Write
A
PRE
PRE
PRE
Read
A
Precharge
PREALL
Automatic Sequence
Command Sequence
PREALL = Precharge All Banks
MRS = Mode Register Set
EMRS = Extended Mode Register Set
REFS = Enter Self Refresh
REFSX = Exit Self Refresh
REFA = Auto Refresh
Figure 32
Data Sheet
CKEL = Enter Power Down
CKEH = Exit Power Down
ACT = Active
Write A = Write with Autoprecharge
Read A = Read with Autoprecharge
PRE = Precharge
Simplified State Diagram
58
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
4
Electrical Characteristics
Operating Conditions
Table 12
Absolute Maximum Ratings
Parameter
Symbol
Voltage on I/O pins relative to VSS
Voltage on inputs relative to VSS
Voltage on VDD supply relative to VSS
Voltage on VDDQ supply relative to VSS
Operating temperature (ambient)
Storage temperature (plastic)
Power dissipation (per SDRAM component)
Short circuit output current
VIN, VOUT
VIN
VDD
VDDQ
TA
TSTG
PD
IOUT
Values
Unit Note/ Test
Condition
Min.
Typ.
Max.
–0.5
–
VDDQ +0.5 V
–
–1
–
+3.6
V
–
–1
–
+3.6
V
–
–1
–
+3.6
V
–
0
–
+70
°C
–
-55
–
+150
°C
–
–
1.5
–
W
–
–
50
–
mA
–
Attention: Permanent damage to the device may occur if “Absolute Maximum Ratings” are exceeded. This
is a stress rating only, and functional operation should be restricted to recommended operation
conditions. Exposure to absolute maximum rating conditions for extended periods of time may
affect device reliability and exceeding only one of the values may cause irreversible damage to
the integrated circuit.
Table 13
Input and Output Capacitances
Parameter
Input Capacitance: CK, CK
Delta Input Capacitance
Input Capacitance:
All other input-only pins
Delta Input Capacitance:
All other input-only pins
Symbol
CI1
CdI1
CI2
CdIO
Input/Output Capacitance: DQ, DQS, DM CIO
Values
Unit
Note/
Test Condition
Min.
Typ.
Max.
1.5
—
2.5
pF
P-TFBGA-60-2 1)
2.0
—
3.0
pF
P-TSOPII-66-1 1)
—
—
0.25
pF
1)
1.5
—
2.5
pF
P-TFBGA-60-2 1)
2.0
—
3.0
pF
P-TSOPII-66-1 1)
—
—
0.5
pF
1)
3.5
—
4.5
pF
P-TFBGA-60-2 1)2)
4.0
—
5.0
pF
P-TSOPII-66-1
1)2)
Delta Input/Output Capacitance:
DQ, DQS, DM
CdIO
—
—
0.5
pF
1)
1) These values are guaranteed by design and are tested on a sample base only. VDDQ = VDD = 2.5 V ± 0.2 V, f = 100 MHz,
TA = 25 °C, VOUT(DC) = VDDQ/2, VOUT (Peak to Peak) 0.2 V. Unused pins are tied to ground.
2) DM inputs are grouped with I/O pins reflecting the fact that they are matched in loading to DQ and DQS to facilitate trace
matching at the board level.
Data Sheet
59
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 14
Electrical Characteristics and DC Operating Conditions
Parameter
Symbol
VDD
Device Supply Voltage
VDD
Output Supply Voltage
VDDQ
Output Supply Voltage
VDDQ
Supply Voltage, I/O Supply VSS,
Voltage
VSSQ
VREF
Input Reference Voltage
Device Supply Voltage
Input Reference Voltage
I/O Termination Voltage
(System)
VREF
VTT
Input High (Logic1) Voltage VIH(DC)
Input Low (Logic0) Voltage VIL(DC)
Unit Note/Test Condition 1)
Values
Min.
Typ.
Max.
2.3
2.5
2.7
V
2.5
2.6
2.7
V
2.3
2.5
2.7
V
2.5
2.6
2.7
V
fCK ≤ 166 MHz
fCK > 166 MHz 2)
fCK ≤ 166 MHz 3)
fCK > 166 MHz 2)3)
0
V
—
0.51 ×
V
fCK ≤ 166 MHz 4)
VDDQ
VDDQ / 2
V
fCK > 166 MHz 2)4)
0
0.49 ×
0.5 ×
VDDQ
VDDQ / 2
VDDQ
VDDQ
/2
– 50 mV
+ 50 mV
VREF – 0.04
VREF + 0.04 V
5)
VREF + 0.15
8)
Input Voltage Level,
CK and CK Inputs
VIN(DC)
–0.3
VDDQ + 0.3 V
VREF – 0.15 V
VDDQ + 0.3 V
Input Differential Voltage,
CK and CK Inputs
VID(DC)
0.36
VDDQ + 0.6 V
8)6)
VI-Matching Pull-up
Current to Pull-down
Current
VIRatio
0.71
1.4
—
7)
Input Leakage Current
II
–2
2
µA
Any input 0 V ≤ VIN ≤ VDD;
All other pins not under test
= 0 V 8)9)
Output Leakage Current
IOZ
–5
5
µA
DQs are disabled;
0 V ≤ VOUT ≤ VDDQ 8)
Output High Current,
Normal Strength Driver
IOH
—
–16.2
mA
VOUT = 1.95 V 8)
Output Low
Current, Normal Strength
Driver
IOL
16.2
—
mA
VOUT = 0.35 V 8)
–0.3
8)
8)
1) 0 °C ≤ TA ≤ 70 °C
2) DDR400 conditions apply for all clock frequencies above 166 MHz
3) Under all conditions, VDDQ must be less than or equal to VDD.
4) Peak to peak AC noise on VREF may not exceed ± 2% VREF (DC). VREF is also expected to track noise variations in VDDQ.
5) VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal
to VREF, and must track variations in the DC level of VREF.
6) VID is the magnitude of the difference between the input level on CK and the input level on CK.
7) The ration of the pull-up current to the pull-down current is specified for the same temperature and voltage, over the entire
temperature and voltage range, for device drain to source voltage from 0.25 to 1.0 V. For a given output, it represents the
maximum difference between pull-up and pull-down drivers due to process variation.
8) Inputs are not recognized as valid until VREF stabilizes.
9) Values are shown per component
Data Sheet
60
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
4.1
Normal Strength Pull-down and Pull-up Characteristics
1. The nominal pull-down V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the
inner bounding lines of the V-I curve.
2. The full variation in driver pull-down current from minimum to maximum process, temperature, and voltage lie
within the outer bounding lines of the V-I curve.
3. The nominal pull-up V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner
bounding lines of the V-I curve.
4. The full variation in driver pull-up current from minimum to maximum process, temperature, and voltage lie
within the outer bounding lines of the V-I curve.
5. The full variation in the ratio of the maximum to minimum pull-up and pull-down current does not exceed 1.7,
for device drain to source voltages from 0.1 to 1.0.
6. The full variation in the ratio of the nominal pull-up to pull-down current should be unity ±10%, for device drain
to source voltages from 0.1 to 1.0 V.
140
Maximum
IOUT (mA)
120
100
Nominal High
80
60
Nominal Low
40
Minimum
20
0
0
0.5
1
1.5
2
2.5
VDDQ - VOUT (V)
Figure 33
Normal Strength Pull-down Characteristics
0
-20
Minimum
IOUT (mA)
-40
Nominal Low
-60
-80
-100
-120
-140
Nominal High
-160
Maximum
0
Figure 34
Data Sheet
0.5
1
1.5
VDDQ - VOUT (V)
2
2.5
Normal Strength Pull-up Characteristics
61
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 15
Normal Strength Pull-down and Pull-up Currents
Voltage (V)
Pulldown Current (mA)
Pullup Current (mA)
Nominal
Low
Nominal
High
Min.
Max.
Nominal
Low
Nominal
High
Min.
Max.
0.1
6.0
6.8
4.6
9.6
-6.1
-7.6
-4.6
-10.0
0.2
12.2
13.5
9.2
18.2
-12.2
-14.5
-9.2
-20.0
0.3
18.1
20.1
13.8
26.0
-18.1
-21.2
-13.8
-29.8
0.4
24.1
26.6
18.4
33.9
-24.0
-27.7
-18.4
-38.8
0.5
29.8
33.0
23.0
41.8
-29.8
-34.1
-23.0
-46.8
0.6
34.6
39.1
27.7
49.4
-34.3
-40.5
-27.7
-54.4
0.7
39.4
44.2
32.2
56.8
-38.1
-46.9
-32.2
-61.8
0.8
43.7
49.8
36.8
63.2
-41.1
-53.1
-36.0
-69.5
0.9
47.5
55.2
39.6
69.9
-43.8
-59.4
-38.2
-77.3
1.0
51.3
60.3
42.6
76.3
-46.0
-65.5
-38.7
-85.2
1.1
54.1
65.2
44.8
82.5
-47.8
-71.6
-39.0
-93.0
1.2
56.2
69.9
46.2
88.3
-49.2
-77.6
-39.2
-100.6
1.3
57.9
74.2
47.1
93.8
-50.0
-83.6
-39.4
-108.1
1.4
59.3
78.4
47.4
99.1
-50.5
-89.7
-39.6
-115.5
1.5
60.1
82.3
47.7
103.8
-50.7
-95.5
-39.9
-123.0
1.6
60.5
85.9
48.0
108.4
-51.0
-101.3
-40.1
-130.4
1.7
61.0
89.1
48.4
112.1
-51.1
-107.1
-40.2
-136.7
1.8
61.5
92.2
48.9
115.9
-51.3
-112.4
-40.3
-144.2
1.9
62.0
95.3
49.1
119.6
-51.5
-118.7
-40.4
-150.5
2.0
62.5
97.2
49.4
123.3
-51.6
-124.0
-40.5
-156.9
2.1
62.9
99.1
49.6
126.5
-51.8
-129.3
-40.6
-163.2
2.2
63.3
100.9
49.8
129.5
-52.0
-134.6
-40.7
-169.6
2.3
63.8
101.9
49.9
132.4
-52.2
-139.9
-40.8
-176.0
2.4
64.1
102.8
50.0
135.0
-52.3
-145.2
-40.9
-181.3
2.5
64.6
103.8
50.2
137.3
-52.5
-150.5
-41.0
-187.6
2.6
64.8
104.6
50.4
139.2
-52.7
-155.3
-41.1
-192.9
2.7
65.0
105.4
50.5
140.8
-52.8
-160.1
-41.2
-198.2
Table 16
Evaluation Conditions for I/O Driver Characteristics
Parameter
Nominal
Minimum
Maximum
Operating Temperature
25 °C
0 °C
70 °C
VDD/VDDQ
2.5 V
2.3 V
2.7 V
Process Corner
typical
slow-slow
fast-fast
Data Sheet
62
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
4.2
Weak Strength Pull-down and Pull-up Characteristics
1. The weak pull-down V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner
bounding lines of the V-I curve.
2. The weak pull-up V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner
bounding lines of the V-I curve.
3. The full variation in driver pull-up current from minimum to maximum process, temperature, and voltage lie
within the outer bounding lines of the V-I curve.
4. The full variation in the ratio of the maximum to minimum pull-up and pull-down current does not exceed 1.7,
for device drain to source voltages from 0.1 to 1.0.
5. The full variation in the ratio of the nominal pull-up to pull-down current should be unity ±10%, for device drain
to source voltages from 0.1 to 1.0 V.
80
Maximum
70
Iout [mA]
60
Typical high
50
Typical low
40
30
Minimum
20
10
0
0,0
0,5
1,0
1,5
2,0
2,5
Vout [V]
Figure 35
Weak Strength Pull-down Characteristics
0,0
0,0
0,5
1,0
1,5
2,0
2,5
-10,0
Minimum
-20,0
Iout [V]
-30,0
Typical low
-40,0
-50,0
Typical high
-60,0
-70,0
Maximum
-80,0
Vout [V]
Figure 36
Data Sheet
Weak Strength Pull-up Characteristics
63
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 17
Weak Strength Driver Pull-down and Pull-up Characteristics
Voltage (V)
Pulldown Current (mA)
Pullup Current (mA)
Nominal
Low
Nominal
High
Min.
Max.
Nominal
Low
Nominal
High
Min.
Max.
0.1
3.4
3.8
2.6
5.0
-3.5
-4.3
-2.6
-5.0
0.2
6.9
7.6
5.2
9.9
-6.9
-8.2
-5.2
-9.9
0.3
10.3
11.4
7.8
14.6
-10.3
-12.0
-7.8
-14.6
0.4
13.6
15.1
10.4
19.2
-13.6
-15.7
-10.4
-19.2
0.5
16.9
18.7
13.0
23.6
-16.9
-19.3
-13.0
-23.6
0.6
19.6
22.1
15.7
28.0
-19.4
-22.9
-15.7
-28.0
0.7
22.3
25.0
18.2
32.2
-21.5
-26.5
-18.2
-32.2
0.8
24.7
28.2
20.8
35.8
-23.3
-30.1
-20.4
-35.8
0.9
26.9
31.3
22.4
39.5
-24.8
-33.6
-21.6
-39.5
1.0
29.0
34.1
24.1
43.2
-26.0
-37.1
-21.9
-43.2
1.1
30.6
36.9
25.4
46.7
-27.1
-40.3
-22.1
-46.7
1.2
31.8
39.5
26.2
50.0
-27.8
-43.1
-22.2
-50.0
1.3
32.8
42.0
26.6
53.1
-28.3
-45.8
-22.3
-53.1
1.4
33.5
44.4
26.8
56.1
-28.6
-48.4
-22.4
-56.1
1.5
34.0
46.6
27.0
58.7
-28.7
-50.7
-22.6
-58.7
1.6
34.3
48.6
27.2
61.4
-28.9
-52.9
-22.7
-61.4
1.7
34.5
50.5
27.4
63.5
-28.9
-55.0
-22.7
-63.5
1.8
34.8
52.2
27.7
65.6
-29.0
-56.8
-22.8
-65.6
1.9
35.1
53.9
27.8
67.7
-29.2
-58.7
-22.9
-67.7
2.0
35.4
55.0
28.0
69.8
-29.2
-60.0
-22.9
-69.8
2.1
35.6
56.1
28.1
71.6
-29.3
-61.2
-23.0
-71.6
2.2
35.8
57.1
28.2
73.3
-29.5
-62.4
-23.0
-73.3
2.3
36.1
57.7
28.3
74.9
-29.5
-63.1
-23.1
-74.9
2.4
36.3
58.2
28.3
76.4
-29.6
-63.8
-23.2
-76.4
2.5
36.5
58.7
28.4
77.7
-29.7
-64.4
-23.2
-77.7
2.6
36.7
59.2
28.5
78.8
-29.8
-65.1
-23.3
-78.8
2.7
36.8
59.6
28.6
79.7
-29.9
-65.8
-23.3
-79.7
Data Sheet
64
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
4.3
AC Characteristics
(Notes 1-5 apply to the following Tables; Electrical Characteristics and DC Operating Conditions, AC Operating
Conditions, IDD Specifications and Conditions, and Electrical Characteristics and AC Timing.)
Notes
1. All voltages referenced to VSS.
2. Tests for AC timing, IDD, and electrical, AC and DC characteristics, may be conducted at nominal reference/
supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage
range specified.
3. Figure 37 represents the timing reference load used in defining the relevant timing parameters of the part. It
is not intended to be either a precise representation of the typical system environment nor a depiction of the
actual load presented by a production tester. System designers will use IBIS or other simulation tools to
correlate the timing reference load to a system environment. Manufacturers will correlate to their production
test conditions (generally a coaxial transmission line terminated at the tester electronics).
4. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5 V in the test environment, but input timing is
still referenced to VREF (or to the crossing point for CK, CK), and parameter specifications are guaranteed for
the specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1 V/
ns in the range between VIL(AC) and VIH(AC).
5. The AC and DC input level specifications are as defined in the SSTL_2 Standard (i.e. the receiver effectively
switches as a result of the signal crossing the AC input level, and remains in that state as long as the signal
does not ring back above (below) the DC input LOW (HIGH) level).
6. For System Characteristics like Setup & Holdtime Derating for Slew Rate, I/O Delta Rise/Fall Derating, DDR
SDRAM Slew Rate Standards, Overshoot & Undershoot specification and Clamp V-I characteristics see the
latest JEDEC specification for DDR components.
VTT
50 Ω
Output
(VOUT)
Timing Reference Point
30 pF
Figure 37
Data Sheet
AC Output Load Circuit Diagram / Timing Reference Load
65
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 18
AC Operating Conditions1)
Parameter
Symbol
Values
Min.
Input High (Logic 1) Voltage, DQ, DQS and DM Signals
Input Low (Logic 0) Voltage, DQ, DQS and DM Signals
Input Differential Voltage, CK and CK Inputs
Input Closing Point Voltage, CK and CK Inputs
VIH(AC)
VIL(AC)
VID(AC)
VIX(AC)
Unit Note/
Test
Condition
Max.
VREF + 0.31 —
—
VREF – 0.31
0.7
VDDQ + 0.6
0.5 × VDDQ 0.5 × VDDQ
– 0.2
V
2)3)
V
2)3)
V
2)3)4)
V
2)3)5)
+ 0.2
1) VDDQ = 2.5 V ± 0.2 V, VDD = +2.5 V ± 0.2 V (DDR200 - DDR333); VDDQ = 2.6 V ± 0.1 V, VDD = +2.6 V ± 0.1 V (DDR400);
0 °C ≤ TA ≤ 70 °C
2) Input slew rate = 1 V/ns.
3) Inputs are not recognized as valid until VREF stabilizes.
4) VID is the magnitude of the difference between the input level on CK and the input level on CK.
5) The value of VIX is expected to equal 0.5 × VDDQ of the transmitting device and must track variations in the DC level of the
same.
Table 19
AC Timing - Absolute Specifications for PC3200, PC2700 and PC2100
Parameter
Symbol –5
–6
DDR400B
–7
DDR333
Unit
DDR266A
Note/ Test
Condition
1)
Min.
Max.
Min.
Max.
Min.
Max.
DQ output access time from CK/ tAC
CK
–0.5
+0.5
–0.7
+0.7
–0.75
+0.75
ns
2)3)4)5)
DQS output access time from CK/ tDQSCK
CK
–0.5
+0.5
–0.6
+0.6
–0.75
+0.75
ns
2)3)4)5)
0.45
0.55
0.45
0.55
0.45
0.55
2)3)4)5)
0.45
0.55
0.45
0.55
0.45
0.55
tCK
tCK
CK high-level width
CK low-level width
Clock Half Period
Clock cycle time
tCH
tCL
tHP
tCK
min. (tCL, tCH) min. (tCL, tCH) min. (tCL, tCH) ns
5
8
6
12
7
12
ns
2)3)4)5)
2)3)4)5)
CL = 3.0
2)3)4)5)
6
12
6
12
7.5
12
ns
CL = 2.5
2)3)4)5)
7.5
12
7.5
12
7.5
12
ns
CL = 2.0
2)3)4)5)
tDH
tDS
tIPW
0.4
—
0.45
—
0.5
—
ns
2)3)4)5)
0.4
—
0.45
—
0.5
—
ns
2)3)4)5)
2.2
—
2.2
—
2.2
—
ns
2)3)4)5)6)
DQ and DM input pulse width
(each input)
tDIPW
1.75
—
1.75
—
1.75
—
ns
2)3)4)5)6)
Data-out high-impedance time
from CK/CK
tHZ
—
+0.7
–0.7
+0.7
—
+0.75
ns
2)3)4)5)7)
Data-out low-impedance time
from CK/CK
tLZ
–0.7
+0.7
–0.7
+0.7
–0.75
+0.75
ns
2)3)4)5)7)
Write command to 1st DQS
latching transition
tDQSS
0.72
1.25
0.75
1.25
0.75
1.25
tCK
2)3)4)5)
DQ and DM input hold time
DQ and DM input setup time
Control and Addr. input pulse
width (each input)
Data Sheet
66
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 19
AC Timing - Absolute Specifications for PC3200, PC2700 and PC2100
Parameter
Symbol –5
–6
DDR400B
DQS-DQ skew (DQS and
associated DQ signals)
tDQSQ
–7
DDR333
Unit
DDR266A
Min.
Max.
Min.
Max.
Min.
Max.
—
+0.40
—
+0.40
—
+0.5
Note/ Test
Condition
1)
ns
TFBGA
2)3)4)5)
—
+0.40
—
+0.45
—
+0.5
ns
TSOPII
2)3)4)5)
Data hold skew factor
tQHS
—
+0.50
—
+0.50
+0.75
ns
TFBGA
2)3)4)5)
—
+0.50
—
+0.55
+0.75
ns
TSOPII
2)3)4)5)
DQ/DQS output hold time
tQH
DQS input low (high) pulse width tDQSL,H
(write cycle)
tHP – —
tQHS
tHP – —
tQHS
tHP –
tQHS
—
ns
2)3)4)5)
0.35
—
0.35
—
0.35
—
tCK
2)3)4)5)
DQS falling edge to CK setup
time (write cycle)
tDSS
0.2
—
0.2
—
0.2
—
tCK
2)3)4)5)
DQS falling edge hold time from
CK (write cycle)
tDSH
0.2
—
0.2
—
0.2
—
tCK
2)3)4)5)
2
—
2
—
2
—
tCK
2)3)4)5)
0
—
0
—
0
—
ns
2)3)4)5)8)
0.40
0.60
0.40
0.60
0.40
0.60
2)3)4)5)9)
0.25
—
0.25
—
0.25
—
tCK
tCK
0.6
—
0.75
—
0.9
—
ns
fast slew
rate
Mode register set command cycle tMRD
time
Write preamble setup time
Write postamble
Write preamble
Address and control input setup
time
tWPRES
tWPST
tWPRE
tIS
2)3)4)5)
3)4)5)6)10)
0.7
—
0.8
—
1.0
—
ns
slow slew
rate
3)4)5)6)10)
Address and control input hold
time
tIH
0.6
—
0.75
—
0.9
—
ns
fast slew
rate
3)4)5)6)10)
0.7
—
0.8
—
1.0
1.1
ns
slow slew
rate
3)4)5)6)10)
0.9
1.1
0.9
1.1
0.9
1.0
0.40
0.60
0.40
0.60
0.40
0.60
40
70E+3 42
70E+3 45
120E+ ns
3
2)3)4)5)
Active to Active/Auto-refresh
command period
tRC
55
—
60
—
65
—
ns
2)3)4)5)
Auto-refresh to Active/Autorefresh command period
tRFC
70
—
72
—
75
—
ns
2)3)4)5)
Active to Read or Write delay
tRCD
tRP
15
—
18
—
20
—
ns
2)3)4)5)
15
—
18
—
20
—
ns
2)3)4)5)
Read postamble
Active to Precharge command
Precharge command period
Data Sheet
67
tCK
tCK
2)3)4)5)
tRPRE
tRPST
tRAS
Read preamble
2)3)4)5)
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 19
AC Timing - Absolute Specifications for PC3200, PC2700 and PC2100
Parameter
Symbol –5
–6
DDR400B
Min.
Max.
DDR333
Min.
Active to Autoprecharge delay
tRAP
tRCD or
tRASmin
Active bank A to Active bank B
command
tRRD
10
—
12
tWR
Auto precharge write recovery + tDAL
15
—
15
Write recovery time
–7
Max.
Unit
DDR266A
Min.
1)
Max.
tRCD or tRASmin ns
2)3)4)5)
—
15
2)3)4)5)
—
15
tRCD or
tRASmin
—
(tWR/tCK) + (tRP/tCK)
precharge time
Note/ Test
Condition
ns
ns
2)3)4)5)
tCK
2)3)4)5)11)
Internal write to read command
delay
tWTR
2
—
1
—
1
—
tCK
2)3)4)5)
Exit self-refresh to non-read
command
tXSNR
75
—
75
—
75
—
ns
2)3)4)5)
Exit self-refresh to read
command
tXSRD
200
—
200
—
200
—
tCK
2)3)4)5)
Average Periodic Refresh
Interval
tREFI
—
15.6
—
15.6
—
15.6
µs
2)3)4)5)12)
1) 0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5 V ± 0.2 V, VDD = +2.5 V ± 0.2 V (DDR333); VDDQ = 2.6 V ± 0.1 V, VDD = +2.6 V ± 0.1 V
(DDR400)
2) Input slew rate ≥ 1 V/ns for DDR400, DDR333
3) The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross: the input reference
level for signals other than CK/CK, is VREF. CK/CK slew rate are ≥ 1.0 V/ns.
4) Inputs are not recognized as valid until VREF stabilizes.
5) The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (note 3) is VTT.
6) These parameters guarantee device timing, but they are not necessarily tested on each device.
7) tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred
to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ).
8) The specific requirement is that DQS be valid (HIGH, LOW, or some point on a valid transition) on or before this CK edge.
A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were
previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress,
DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS.
9) The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but
system performance (bus turnaround) degrades accordingly.
10) Fast slew rate ≥ 1.0 V/ns , slow slew rate ≥ 0.5 V/ns and < 1 V/ns for command/address and CK & CK slew rate > 1.0 V/
ns, measured between VIH(ac) and VIL(ac).
11) For each of the terms, if not already an integer, round to the next highest integer. tCK is equal to the actual system clock
cycle time.
12) A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device.
Data Sheet
68
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 20
IDD Conditions
Parameter
Symbol
Operating Current 0
one bank; active/ precharge; tRC = tRC,MIN;
DQ, DM, and DQS inputs changing once per clock cycle;
address and control inputs changing once every two clock cycles.
IDD0
Operating Current 1
IDD1
one bank; active/read/precharge; Burst Length = 4; Refer to Chapter 4.3.1 for detailed test conditions.
Precharge Power-Down Standby Current
all banks idle; power-down mode; CKE ≤ VIL,MAX
IDD2P
Precharge Floating Standby Current
CS ≥ VIH,,MIN, all banks idle; CKE ≥ VIH,MIN;
address and other control inputs changing once per clock cycle; VIN = VREF for DQ, DQS and DM.
IDD2F
Precharge Quiet Standby Current
CS ≥ VIHMIN, all banks idle; CKE ≥ VIH,MIN;
address and other control inputs stable at ≥ VIH,MIN or ≤ VIL,MAX; VIN = VREF for DQ, DQS and DM.
IDD2Q
Active Power-Down Standby Current
one bank active; power-down mode; CKE ≤ VILMAX; VIN = VREF for DQ, DQS and DM.
IDD3P
Active Standby Current
one bank active; CS ≥ VIH,MIN; CKE ≥ VIH,MIN; tRC = tRAS,MAX;
DQ, DM and DQS inputs changing twice per clock cycle;
address and control inputs changing once per clock cycle.
IDD3N
Operating Current Read
one bank active; Burst Length = 2; reads; continuous burst;
address and control inputs changing once per clock cycle;
50% of data outputs changing on every clock edge;
CL = 2 for DDR266(A), CL = 3 for DDR333 and DDR400B; IOUT = 0 mA
IDD4R
Operating Current Write
one bank active; Burst Length = 2; writes; continuous burst;
address and control inputs changing once per clock cycle;
50% of data outputs changing on every clock edge;
CL = 2 for DDR266(A), CL = 3 for DDR333 and DDR400B
IDD4W
Auto-Refresh Current
tRC = tRFCMIN, burst refresh
IDD5
Self-Refresh Current
CKE ≤ 0.2 V; external clock on
IDD6
Operating Current 7
four bank interleaving with Burst Length = 4; Refer to Chapter 4.3.1 for detailed test conditions.
IDD7
Data Sheet
69
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
Table 21
IDD Specification
Unit
Note/Test Condition1)
90
mA
×4/×8 2)3)
75
90
mA
×16
85
80
100
mA
×4/×8 2)3)
95
95
110
mA
×16
–7
–6
–5
DDR266A
DDR333
DDR400B
Symbol
Typ.
Max.
Typ.
Max.
Typ.
Max.
IDD0
50
65
60
75
70
55
65
65
75
65
75
70
70
85
80
IDD1
IDD2P
IDD2F
IDD2Q
IDD3P
IDD3N
IDD4R
IDD4W
IDD5
IDD6
IDD7
3
4
3.5
4.5
4
5
mA
2)3)
20
24
25
30
30
36
mA
2)3)
15
21
17
24
20
28
mA
2)3)
9
13
11
15
13
18
mA
2)3)
28
36
32
38
38
45
mA
×4/×8 2)3)
30
40
36
45
43
54
mA
×16
60
70
70
85
85
100
mA
×4/×8 2)3)
70
85
85
100
100
120
mA
×16
65
75
75
90
90
105
mA
×4/×8 2)3)
75
90
90
110
100
130
mA
×16
100
140
120
160
140
190
mA
2)3)
1.4
2.8
1.4
2.8
1.4
2.8
mA
standard version 2)3)4)
1.1
1.1
1.1
1.1
mA
low power version
140
170
180
215
210
250
mA
×4/×8 2)3)
140
170
180
215
210
250
mA
×16
1) Test conditions for typical values: VDD = 2.5 V ( DDR266, DDR333), VDD = 2.6 V (DDR400), TA = 25 °C, test conditions
for maximum values: VDD = 2.7 V, TA = 10 °C
2) IDD specifications are tested after the device is properly initialized and measured at 133 MHz for DDR266, 166 MHz for
DDR333, and 200 MHz for DDR400.
3) Input slew rate = 1 V/ns.
4) Enables on-chip refresh and address counters.
Data Sheet
70
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Electrical Characteristics
4.3.1
IDD Current Measurement Conditions
Legend: A = Activate, R = Read, RA = Read with Autoprecharge, P = Precharge, N = NOP or DESELECT
IDD1: Operating Current: One Bank Operation
1. General test condition
a) Only one bank is accessed with tRC,MIN.
b) Burst Mode, Address and Control inputs are changing once per NOP and DESELECT cycle.
c) 50% of data changing at every transfer
d) IOUT = 0 mA.
2. Timing patterns
a) DDR266A (133 MHz, CL = 2): tCK = 7.5 ns, BL = 4, tRCD = 3 × tCK, tRC = 9 × tCK, tRAS = 5 × tCK
Setup: A0 N N R0 N P0 N N N
Read: A0 N N R0 N P0 N NN - repeat the same timing with random address changing
b) DDR333B (166 MHz, CL = 2.5): tCK = 6 ns, BL = 4, tRCD = 3 × tCK, tRC = 9 × tCK, tRAS = 5 × tCK
Setup: A0 N N R0 N P0 N N N
Read: A0 N N R0 N P0 N N N - repeat the same timing with random address changing
c) DDR400B (200 MHz, CL = 3): tCK = 5 ns, BL = 4, tRCD = 3 × tCK, tRC = 11 × tCK, tRAS = 8 × tCK
Setup:A0 N N R0 N N N N P0 N N
Read: A0 N N R0 N N N N P0 N N -repeat the same timing with random address changing
IDD7: Operating Current: Four Bank Operation
1. General test condition
a) Four banks are being interleaved with tRCMIN.
b) Burst Mode, Address and Control inputs on NOP edge are not changing.
c) 50% of data changing at every transfer
d) IOUT = 0 mA.
2. Timing patterns
a) DDR266A (133 MHz, CL = 2): tCK = 7.5 ns, BL = 4, tRRD = 2 × tCK, tRCD = 3 × tCK, tRAS = 5 × tCK
Setup: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3
Read: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing
b) DDR333B (166 MHz, CL = 2.5): tCK = 6 ns, BL = 4, tRRD = 2 × tCK, tRCD = 3 × tCK, tRAS = 5 × tCK
Setup: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3
Read: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing
c) DDR400B (200 MHz, CL = 3): tCK = 5 ns, BL = 4, tRRD = 2 × tCK, tRCD = 3 *× tCK, tRAS = 8 × tCK
Setup: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 N
Read: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 N - repeat the same timing with random address
Data Sheet
71
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
5
Timing Diagrams
tDQSL
tDQSH
DQS
tDH
tDS
DI n
DQ
tDH
tDS
DM
DI n = Data In for column n.
3 subsequent elements of data in are applied in programmed order following DI n.
Figure 38
Don’t Care
Data Input (Write), Timing Burst Length = 4
DQS
tDQSQ max
tQH
DQ
tQH (Data output hold time from DQS)
tDQSQ and tQH are only shown once and are shown referenced to different edges of DQS, only for clarify of illustration.
t.DQSQ and tQH both apply to each of the four relevant edges of DQS.
tDQSQ max. is used to determine the worst case setup time for controller data capture.
tQH is used to determine the worst case hold time for controller data capture.
Figure 39
Data Sheet
Data Output (Read), Timing Burst Length = 4
72
Rev. 1.0, 2004-04
Figure 40
Data Sheet
73
tVTD
High-Z
High-Z
200µs
Power-up:
VDD and CK
stable
LVCMOS LOW LEVEL
Don’t Care
DQ
DQS
BA0, BA1
A10
A0-A9, A11
DM
Command
CKE
CK
CK
VREF
VTT (System*)
VDDQ
VDD
tIH
tIH
NOP
tIS
tIS
tCH
tIH
PRE
tIS
tCL
tIH
tIH
tIH
BA1=L
BA0=H
tIS
CODE
tIS
CODE
tIS
EMRS
tMRD
Extended Mode
Register Set
ALL BANKS
tCK
tIH
CODE
CODE
MRS
Load Mode
Register, Reset DLL
tMRD
Load Mode
Register
(with A8 = L)
BA0=L
AR
tRFC
BA1=L
AR
tRFC
200 cycles of CK**
BA0=L
ALL BANKS
tIS
PRE
tRP
BA1=L
CODE
CODE
MRS
tMRD
The two Autorefresh commands may be moved to follow the first MRS,
but precede the second Precharge All command.
** tMRD is required before any command can be applied and
200 cycles of CK are required before a Read command can be applied.
* VTT is not applied directly to the device, however tVTD must be
greater than or equal to zero to avoid device latchup.
BA
RA
RA
ACT
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Initialize and Mode Register Sets
Rev. 1.0, 2004-04
Figure 41
Data Sheet
74
tIH
tIH
tIH
VALID
tIS
VALID*
tIS
tIS
tCK
NOP
Enter Power
Down Mode
tIS
tCH
tCL
No column accesses are allowed to be in progress at the time power down is entered.
* = If this command is a Precharge (or if the device is already in the idle state) then the power down mode
shown is Precharge power down. If this command is an Active (or if at least one row is already active), then
the power down mode shown is Active power down.
DM
DQ
DQS
ADDR
Command
CKE
CK
CK
NOP
Exit Power
Down Mode
tIS
Don’t Care
VALID
VALID
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Power Down Mode
Rev. 1.0, 2004-04
Figure 42
Data Sheet
tIH
tIH
NOP
AR
NOP
AR
NOP
VALID
tRFC
NOP
ACT
75
tIH
BANK(S)
tIS
ONE BANK
PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address; AR = Autorefresh.
NOP commands are shown for ease of illustration; other valid commands may be possible at these times.
DM, DQ, and DQS signals are all don't care/high-Z for operations shown.
DM
DQ
DQS
BA0, BA1
A10
Don’t Care
BA
RA
RA
ALL BANKS
NOP
tRFC
A9, A11,A11
PRE
VALID
tCL
RA
NOP
tIS
tIS
tCK
tRP
A0-A8
Command
CKE
CK
CK
tCH
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Auto Refresh Mode
Rev. 1.0, 2004-04
Figure 43
Data Sheet
76
DM
DQ
DQS
ADDR
Command
CKE
CK
CK
NOP
tIH
tIH
tCH
tCK
tIS
AR
Enter Self
Refresh Mode
tCL
* = Device must be in the all banks idle state before entering Self Refresh Mode.
** = tXSNR is required before any non-read command can be applied, and tXSRD (200 cycles of CK).
are required before a Read command can be applied.
tIS
tIS
tRP*
NOP
Exit Self
Refresh Mode
tXSRD, tXSRN
tIS
200 cycles
tIS
tIH
Don’t Care
VALID
VALID
Clock must be stable before exiting Self Refresh Mode
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Self Refresh Mode
Rev. 1.0, 2004-04
Figure 44
Data Sheet
77
Case 2:
tAC/tDQSCK = max
Case 1:
tAC/tDQSCK = min
A10
tIH
tIH
NOP
tIS
tIS
tIH
tIH
tIH
BA x
tIS
DIS AP
tIS
COL n
tIS
Read
CL=2
PRE
tLZ (max)
tLZ (max)
tRPRE
DO n
tAC (max)
DO n
tAC (min)
BA x*
ONE BANK
ALL BANKS
tCL
tLZ (min)
tRPRE
NOP
tCH
NOP
tDQSCK (max)
NOP commands are shown for ease of illustration; other commands may be valid at these times.
DIS AP = Disable Auto Precharge.
* = Don't care if A10 is High at this point.
PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address.
BA x
RA
RA
ACT
tHZ (max)
tRPST
tHZ (min)
tIH
NOP
tDQSCK (min)
tRPST
tRP
3 subsequent elements of data out are provided in the programmed order following DO n.
DO n = data out from column n.
DQ
DQS
DQ
DQS
DM
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tCK
NOP
VALID
NOP
VALID
Don’t Care
NOP
VALID
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Read without Auto Precharge (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 45
Data Sheet
78
Case 2:
tAC/tDQSCK = max
Case 1:
tAC/tDQSCK = min
A10
DQ
DQS
DQ
DQS
DM
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tIH
tIH
tIH
tIH
tIH
BA x
tIS
EN AP
tIS
COL n
tIS
Read
tCL
DO n
tAC (max)
DO n
tAC (min)
NOP
tLZ (max)
tRPRE
tLZ (max)
CL=2
tLZ (min)
tLZ (min)
tRPRE
NOP
tCH
NOP
BA x
RA
RA
ACT
tDQSCK (max)
tHZ (max)
tRPST
tHZ (min)
tIH
NOP
tDQSCK (min)
tRPST
tRP
NOP
VALID
DO n = data out from column n.
3 subsequent elements of data out are provided in the programmed order following DO n.
EN AP = enable Auto Precharge.
ACT = active; RA = row address.
NOP commands are shown for ease of illustration; other commands may be valid at these times.
NOP
tIS
tIS
tCK
NOP
VALID
Don’t Care
NOP
VALID
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Read with Auto Precharge (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 46
Data Sheet
79
DQ
DQS
DQ
DQS
DM
tIH
tIH
NOP
tIS
tIS
tIH
tIH
BA x
tIS
RA
RA
tIS
ACT
tRCD
NOP
tCH
tIH
tRAS
BA x
DIS AP
tIS
COL n
Read
tCL
tRC
CL=2
tLZ (max)
DO n
tAC (max)
DO n
tAC (min)
BA x*
ONE BANK
tLZ (max)
tRPRE
tLZ (min)
PRE
ALL BANKS
tLZ (min)
tRPRE
NOP
DO n = data out from column n.
3 subsequent elements of data out are provided in the programmed order following DO n.
DIS AP = disable Auto Precharge.
* = Don't care if A10 is High at this point.
PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address.
NOP commands are shown for ease of illustration; other commands may be valid at these times.
Case 2:
tAC/tDQSCK = max
Case 1:
tAC/tDQSCK = min
A10
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tCK
NOP
BA x
RA
RA
ACT
tHZ (max)
tHZ (min)
tRPST
tDQSCK (max)
tDQSCK (min)
tRPST
tRP
NOP
Don’t Care
NOP
VALID
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Bank Read Access (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 47
Data Sheet
A10
80
DM
DQ
DQS
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tIH
tIH
tIH
tIH
tWPRES
tDQSS
tIH
BA x
tIS
DIS AP
tIS
COL n
tIS
Write
DIn
tDQSH
tWPRE
NOP
tCH
tDQSL
tCL
NOP
tWPST
tDSH
NOP
tIH
NOP
tWR
PRE
BA x*
ONE BANK
ALL BANKS
tDQSS = min.
DIn = Data in for column n.
3 subsequent elements of data in are applied in the programmed order following DIn.
DIS AP = Disable Auto Precharge.
* = Don't care if A10 is High at this point.
PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address.
NOP commands are shown for ease of illustration; other valid commands may be possible at these times.
NOP
tIS
tIS
tCK
NOP
VALID
tRP
NOP
Don’t Care
BA
RA
RA
ACT
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Write without Auto Precharge (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 48
Data Sheet
A10
81
DM
DQ
DQS
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tIH
tIH
tWPRE
tWPRES
tDQSS
tIH
BA x
tIS
EN AP
tIS
COL n
tIS
Write
DIn
tDQSH
NOP
tCH
tDQSL
tCL
NOP
tWPST
tDSH
NOP
NOP
VALID
tWR
DIn = Data in for column n.
3 subsequent elements of data in are applied in the programmed order following DIn.
EN AP = Enable Auto Precharge.
ACT = Active; RA = Row address; BA = Bank address.
NOP commands are shown for ease of illustration; other valid commands may be possible at these times.
tDQSS = min.
tIH
tIH
NOP
tIS
tIS
tCK
NOP
VALID
tDAL
NOP
VALID
tRP
NOP
Don’t Care
BA
RA
RA
ACT
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Write with Auto Precharge (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 49
Data Sheet
82
A10
DM
DQ
DQS
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tIH
tIH
tIH
tIH
BA x
tIS
RA
RA
tIS
ACT
tRCD
NOP
tCH
tIH
tWPRES
BA x
tDQSS
DIS AP
tIS
Col n
Write
tCL
DIn
tDSH
tDQSL
tWPRE
tDQSH
NOP
tRAS
NOP
tWPST
NOP
tDQSS = min.
DI n = data in for column n.
3 subsequent elements of data in are applied in the programmed order following DI n.
DIS AP = Disable Auto Precharge.
* = don't care if A10 is High at this point.
PRE = Precharge; ACT = Active; RA = Row address.
NOP commands are shown for ease of illustration; other valid commands may be possible at these times.
NOP
tIS
tIS
tCK
tWR
NOP
BA x
ONE BANK
ALL BANKS
PRE
Don’t Care
NOP
VALID
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Bank Write Access (Burst Length = 4)
Rev. 1.0, 2004-04
Figure 50
Data Sheet
A10
83
DM
DQ
DQS
BA0, BA1
A0-A9, A11
Command
CKE
CK
CK
tIH
tIH
tIH
tIH
tIH
tWPRES
BA x
tIS
tDQSS
DIS AP
tIS
COL n
tIS
Write
DIn
tDQSH
NOP
tCH
tDQSL
tCL
NOP
tWPST
tDSH
NOP
tWR
NOP
BA x*
ONE BANK
ALL BANKS
PRE
NOP
VALID
DI n = data in for column n.
3 subsequent elements of data in are applied in the programmed order following DI n (the second element of the 4 is masked).
DIS AP = Disable Auto Precharge.
* = Don't care if A10 is High at this point.
PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address.
NOP commands are shown for ease of illustration; other valid commands may be possible at these times.
tDQSS = min.
NOP
tIS
tIS
tCK
tRP
NOP
Don’t Care
BA
RA
RA
ACT
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Timing Diagrams
Write DM Operation (Burst Length = 4)
Rev. 1.0, 2004-04
HYB25D128[400/800/160]C[C/E/T](L)
128 Mbit Double Data Rate SDRAM
Package Outlines
6
Package Outlines
18
15 x 1 = 15
1
0.18 MAX.
B
A
3)
2)
2)
10
8 x 0.8 = 6.4
2.2 MAX.
0.8
0.2
1)
0.1 C
1.2 MAX.
0.25 MIN.
0.1 C
ø0.4 ±0.05
68x
ø0.15
ø0.08
M
M
C
C SEATING PLANE
A B
1) Package Orientation Mark A1
2) Middle of Packages Edges
3) Dummy Pads without Ball
Gage Plane
0.65 Basic
0.35 +0.1
-0.05
0.805 REF
10.16 ±0.13
0.25 Basic
1.20 MAX.
P-TFBGA-60-2 (Plastic Thin Fine-Pitch Ball Grid Array Package)
0.05 MIN.
Figure 51
0.1
Seating Plane
0.5 ±0.1
11.76 ±0.2
22.22 ±0.13
Lead 1
GPX09261
Figure 52
Data Sheet
P-TSOPII-66-1 (Plastic Thin Small Outline Package Type II)
84
Rev. 1.0, 2004-04
www.infineon.com
Published by Infineon Technologies AG