Mean Well GST18A15-P1J 18w ac-dc high reliability industrial adaptor Datasheet

18W AC-DC High Reliability Industrial Adaptor
■ Features
Universal AC input / Full range
3 pole AC inlet IEC320-C14
No load power consumption< 0.075W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,
GST18A
series
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
AU/NZ MEPS,EU ErP and CoC Version 5
ClassⅠpower (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
High operating temperature up to +70℃
LED indicator for power on
3 years warranty
■ Description
GST18A is a highly reliable, 18W desktop style single-output green adaptor series. This product is a classⅠ
power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from
85VAC to 264VAC. The entire series supplies different models with output voltages ranging between
5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W, GST18A is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP, and
Code of Conduct(CoC) Version 5 . The supreme feature allows the adaptor to save the energy when it is
either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant
plastic case.GST18A is certified for the international safety regulations.
■ Model Encoding
GST 18 A 05 - P1J
DC plug type
{
P1J : Plug for standard model, 2.1ψ × 5.5ψ ×11mm, c+, tuning fork type
Optional plug type available by customer requested
Output voltage
IEC320-C14 AC inlet
Output wattage
Series name
File Name:GST18A-SPEC 2015-06-24
GST18A
18W AC-DC High Reliability Industrial Adaptor
series
SPECIFICATION
GST18A05-P1J GST18A07-P1J GST18A09-P1J GST18A12-P1J GST18A15-P1J GST18A18-P1J GST18A24-P1J GST18A28-P1J GST18A48-P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GST18A05
Note.2 5V
GST18A07
GST18A09
GST18A12
GST18A15
GST18A18
GST18A24
GST18A28
GST18A48
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0 ~ 3.0A
0 ~ 2.0A
0 ~2.0A
0 ~ 1.50A
0 ~ 1.20A
0 ~ 1.0A
0 ~ 0.75A
0 ~ 0.64A
0 ~ 0.375A
RATED POWER (max.)
15W
18W
15W
18W
18W
18W
18W
18W
18W
RIPPLE & NOISE (max.) Note.3 80mVp-p
80mVp-p
80mVp-p
80mVp-p
100mVp-p
150mVp-p
180mVp-p
240mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
88%
88.5%
89%
SETUP, RISE, HOLD UP TIME 1000ms, 30ms, 50ms/230VAC
VOLTAGE RANGE
Note.7 85 ~ 264VAC
FREQUENCY RANGE
INPUT
81%
AC CURRENT
INRUSH CURRENT (max.)
0.5A / 115VAC
0.3A / 230VAC
35A / 115VAC
65A / 230VAC
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
OVERLOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 8)
EMC EMISSION
EMC IMMUNITY
CONNECTOR
NOTE
47 ~ 63Hz
EFFICIENCY (Typ.)
PROTECTION
OTHERS
1500ms, 30ms, 15ms/115VAC at full load
MTBF
DIMENSION
85%
85%
86%
87%
88%
±0.03% / ℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved
I/P-O/P:4242VDC , I/P-FG:2121VDC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25℃)
93*54*36mm (L*W*H)
209g; 60pcs/13.5Kg/1.12CUFT
PACKING
PLUG
See page 3 ; Other type available by customer requested
CABLE
See page 3 ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GST18A-SPEC 2015-06-24
GST18A
18W AC-DC High Reliability Industrial Adaptor
Derating Curve
series
Static Characteristics
100
85
LOAD (%)
LOAD (%)
100
50
80
70
60
50
40
-30
10
20
30
40
50
60
70
85
AMBIENT TEMPERATURE (℃)
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
Unit:mm
UL1185 16AWG 1200±50mm for 5~12V
UL1185 18AWG 1800±50mm for 15~48V
70±10mm
POWER LED
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
NAME PLATE
Inside
-V not connected to AC FG
Plug Assignment
93
36
Standard plug: P1J
54
P1J
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:GST18A-SPEC 2015-06-24
Similar pages