LDC-185 Series Compact, LED, 200W Constant Current AC/DC Power Supply Key Features: • 200W Output Power • UL 8750 Approved • Constant Current Output • Active PFC Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Frequency Inrush Current, See Note 1 230 VAC 115 VAC 230 VAC 264 VAC 0.98 @ 115 VAC 0.95 @ 230 VAC 0.93 @ 264 VAC See Note 2 115 VAC 230 VAC 277 VAC • 90 - 305 VAC Input • IP65 / IP67 Rated Input Current • Meets EN 55015, EN 61547 • Dimming Function Power Factor Correction • >50 kHour Life Expectancy Total Harmonic Distortion (THD) • Lightning Surge Protection Turn On Delay, See Note 3 • Over Volt/Temp Protection Min. 90 127 47 Input Voltage Range Leakage Current Typ. Max. 305 431 63 75 2.10 0.90 0.80 Units VAC VDC Hz A Pk A 10 1.5 0.5 % S 75 mA Max. Units % % V P-P Output Parameter Output Current Accuracy Line Regulation Ripple & Noise (20 MHz) Conditions Output Ripple Current Hold-Up Time Over Temperature Protection Short Circuit Protection Overload Protection Min. Typ. ±5.0 ±1.0 2.0 ±5.0 ±10.0 VIN = Min to Max See Note 4 Outputs Below 50 VDC Outputs Above 71 VDC 115 VAC 12.0 ±10%, Autorecovery 85 Continuous (Autorecovery) Autorecovery 95 % mS °C 107 %IOUT General Parameter Conditions Min. Typ. Max. Units Input to Output 3,750 Input to FG 2,000 VAC Output to FG 500 Input to Output Input to FG 100 M / 500 VDC / 25°C / 70% RH Output to FG Isolation Voltage, 60S Insulation Resistance EMI Characteristics Parameter EMI EMS Surge Standard EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743 EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1 10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS MicroPower Direct Environmental 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Physical Case Size Weight Conditions Min. Typ. Max. -40 +25 +70 -40 +85 Free Air Convection (See Derating Curve on Page 2) RH, Non-condensing 95 Ambient Units °C °C % See Mechanical Diagrams (Page 4) 33.1 Oz (950g) Reliability Specifications Parameter MTBF Life Expectancy Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 220 kHours See Note 5 50 kHours UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14 5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Output Model Number Current Output Power OVP Level (VDC) (W) Efficiency Max (mA) Adj. Range (mA) Voltage Range (VDC) LDC-185-0500 x 500 300 - 500 200 - 400 420 - 450 200 92 LDC-185-0700 x 700 360 - 700 143 - 286 320 - 350 200 92 LDC-185-1050 x 1,050 600 - 1,050 95 - 190 210 - 240 200 92 LDC-185-1400 x 1,400 750 - 1,400 71 - 143 160 - 170 200 92 LDC-185-3150 x 3,150 1,650 - 3,150 32 - 58 62 - 80 183 91 LDC-185-3850 x 3,850 2,000 - 3,850 32 - 49 54 - 73 189 91 LDC-185-4200 x 4,200 2,200 - 4,200 27 - 42 49 - 65 177 91 LDC-185-5250 x 5,250 2,750 - 5,250 25 - 35 41 - 55 183 91 (%, Typ) Notes: 1. Inrush current is given for a cold start at 25°C. 2. Total Harmonic Distortion (THD) is specified with an input of 230 VAC/50 Hz at full load. 3. Turn on delay is specified at full load. 4. Ripple & noise is measured at 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor and a 22 µF electrolytic capacitor connected in parallel. 5. Life expectancy is calculated at 230 VAC, full load and a case temp of +70°C. 6. Recovery from an over voltage fault is automatic. Package Type Model LDC-185-xxxx A LDC-185-xxxx B Ingress Protection IP65 IP67 Dimming Function Adjust by internal, variable resistor Adjust by external resistor, DC voltage level or PWM signal Derating Curve: Temperature Efficiency vs Load: LDC-185-5250 292 Page Street Ste D Stoughton, MA 02072 Derating Curve: Input Voltage PFC vs Load: LDC-185-5250 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Functional Block Diagram Dimming Mode: B Model With the LDC-185 “B” model, the output current level can be adjusted (Dimmed) by three different methods; Resistive, Analog or Digital. Adjustments are made using the +DIM and -DIM inputs. Resistive: Connect a 0.1 to 10 k resistor between the DIM+ (Blue) and DIM- (White) wires Input Frequency 10 k 20 k 30 k 40 k 50 k 60 k 70 k 80 k 90 k 100 k Open Percentage of Rated Current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Analog: Apply 1 VDC to 10 VDC level between the DIM+ (Blue) and DIM- (White) wires Adjust Voltage Percentage of Rated Current 1 VDC 2 VDC 3 VDC 4 VDC 5 VDC 6 VDC 7 VDC 8 VDC 9 VDC 10 VDC Open 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Digital: Apply a PWM signal (100 Hz - 3 kHz) between the DIM+ (Blue) and DIM- (White) wires Duty Cycle 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Open Percentage of Rated Current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Notes: 1. The -DIM (White) and -LED (Black) wires should not be connected. 2. The Dimming function will not turn the lighting fixture totally off. For more info on how to do this, please contact the factory MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Mechanical Dimensions: A Model Wire Connections: Input Wire Connections: Output Color Function Color Function Green/Yellow Brown Blue Field Ground AC-Line AC-Neutral Black Red -LED +LED Mechanical Dimensions: B Model (Dimming Function) Wire Connections: Input Wire Connections: Output Color Function Color Function Green/Yellow Brown Blue Field Ground AC-Line AC-Neutral White Blue -DIM +DIM Black Red -LED +LED MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]