MA800RU Series 4:1 Input Range, 8W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 8W Output Power • 4:1 Input Voltage Range • EN 60950 Approved • Compact DIP Case • 1,600 VDC I/O Isolation • Meets EN 55032 “A” • Single & Dual Outputs • Remote On/Off Control • Wide Temperature Operation • Industry Standard Pin-Out Input Parameter Conditions Input Voltage Range Start Up Time Input Filter Input Reflected Ripple Current Output Parameter Output Voltage Accuracy Line Regulation Load Regulation, See Note 2 Cross Regulation, Dual Output Ripple & Noise (20 MHz) Transient Recovery Time, See Note 5 Transient Response Deviation Output Power Protection Temperature Coefficient Output Short Circuit Protection General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Remote On/Off (See Page 2) Parameter Supply On Supply Off Standby Input Current Control Common Environmental Parameter Operating Temperature Range MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Min. 24 VDC Input 9.0 48 VDC Input 18.0 Nominal VIN & Constant Resistive Load (Pi) Filter Typ. 24.0 48.0 20 Max. 36.0 72.0 Min. VIN = Min to Max Single Output Dual Output See Note 3 See Note 4 Typ. ±1.2 mA P - P Max. ±0.2 ±0.5 ±1.0 ±5.0 75 250 25% Load Step Change ±3.0 150 ±0.02 Continuous (Autorecovery) Conditions Input/Output, 60 Seconds Case/Input, Output, 60 Seconds 500 VDC 100 kHz/1V Conditions See Note On Page 3 Min. 1,600 1,600 1,000 Typ. Max. Ambient Case Min. -40 % % mV P - P µSec % % IOUT %/ºC Units M⍀ pF kHz Typ. Max. 12 1.2 Units VDC VDC mA Max. +85 +105 +125 Units ºC ºC ºC 5.0 Referenced to -Input (Pins 2, 3) Conditions Units % % VDC 1,500 270 Min. 3.0 0.0 VDC mS 20.0 Conditions Units Typ. -40 Free Air Convection RH, Non-condensing 95 % See Mechanical Diagram (Page 3) Copper With Nickel Coating (UL94V-0) 0.63 Oz (18g) Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 1.0 UL 60950, EN 62368, EN 60950 Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. Typ. Max. Units MHours Max. 50.0 100.0 260 Units Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Input Model Number Voltage (VDC) Output Current (mA) Full-Load No-Load Voltage Current Current (VDC) (mA, Max) (mA, Min) Nominal Range MA824S-03RU 24 9.0 - 36.0 345 10 MA824S-05RU 24 9.0 - 36.0 380 MA824S-12RU 24 9.0 - 36.0 385 MA824S-15RU 24 9.0 - 36.0 385 15 15.0 535 MA824D-05RU 24 9.0 - 36.0 400 10 ±5.0 ±800 MA824D-12RU 24 9.0 - 36.0 390 15 ±12.0 ±335 MA824D-15RU 24 9.0 - 36.0 385 15 ±15.0 ±265 MA848S-03RU 48 18.0 - 75.0 170 10 3.3 MA848S-05RU 48 18.0 - 75.0 185 10 5.0 MA848S-12RU 48 18.0 - 75.0 190 10 MA848S-15RU 48 18.0 - 75.0 190 10 MA848D-05RU 48 18.0 - 75.0 200 MA848D-12RU 48 18.0 - 75.0 190 MA848D-15RU 48 18.0 - 75.0 190 3.3 2,000 0.0 10 5.0 1,500 15 12.0 665 Over Max Rating Voltage Capacitive Efficiency Fuse Slow-Blow Protection Load (%, Typ) (mA) (VDC) (µF Max) 3.9 1,330 80 2,000 0.0 6.2 1,330 83 2,000 0.0 15.0 288 87 2,000 0.0 18.0 200 87 2,000 ±0.0 ±15.0 900 86 2,000 ±0.0 ±15.0 133 86 2,000 ±0.0 ±18.0 90 87 2,000 2,000 0.0 3.9 1,330 80 1,000 1,500 0.0 6.2 1,330 84 1,000 12.0 665 0.0 15.0 288 87 1,000 15.0 535 0.0 18.0 200 87 1,000 10 ±5.0 ±800 ±0.0 ±15.0 900 84 1,000 10 ±12.0 ±335 ±0.0 ±15.0 133 87 1,000 10 ±15.0 ±265 ±0.0 ±18.0 90 87 1,000 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is specified for a load change of 0% to 100%. Load regulation for 3.3V output models is ±1.0% max for a load change of 0% to 100%. 3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 4. Output ripple is measured with a 1.0 µF capacitor connected from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. See the typical connection diagram & notes on page 3. 5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%. 6. Operation at no-load will not damage these units. However, they may not meet all specifications. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Temperature Derating Curve Typical Connection To help meet conducted emissions requirements, the filter components (C2, C3 & L1) in the diagram above should be used. The recommended values are 2.2 µF/100V for C2 & C3 and 12 µH for L1. These components should be mounted as close to the module as possible. To meet the requirements of EN 61000-4-4 & EN 61000-4-5, an external filter capacitor (C1 in the diagram above) is required. The recommended value for C1 is 330 µF/100V. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. The Remote On/Off circuit is referenced to the minus input of the unit (pins 2 & 3). If the On/Off input (pin 1) is connected to the minus input, the unit is shut off. If pin 1 is left open, the unit operates normally. Page 2 EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFM We Power Your Success - For Less Standard EN 55032 EN 55032 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Criteria/Level Class A Class A A A A A A A www.micropowerdirect.com Efficiency vs Output Load: 24 VIN Models Efficiency vs Output Load: 48 VIN Models Mechanical Dimensions Pin Connections Pin Single 1 Remote On/Off 2 -VIN 3 -VIN 9 No Pin 11 NC 14 +VOUT 16 -VOUT 22 +VIN 23 +VIN NC: No Connection Dual Remote On/Off -VIN -VIN Common -VOUT +VOUT Common +VIN +VIN Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MPD offers a wide range of DC/DC converters in the standard 24 pin DIP package. Models range from 1W to 15W and offer wide input ranges, high isolation & tight regulation. Many are approved to EN 60950. For full information, go to our website or contact the factory. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]