Seme LAB IP137M-LCC4 0.5 amp negative adjustable voltage regulator in ceramic surface mount package Datasheet

IP137MAHV-LCC4
IP137MHV-LCC4
9.14 (0.360)
8.64 (0.340)
1.27 (0.050)
1.07 (0.040)
≈ 2.16 (0.085)
12 13 14 15 16
1.39 (0.055)
1.02 (0.040)
7.62 (0.300)
7.12 (0.280)
11
17
10
18
9
1
8
2
7
6
1.39 (0.055)
1.15 (0.045)
5
4
3
1.65 (0.065)
1.40 (0.055)
IP137MA-LCC4
IP137M-LCC4A
0.5 AMP
NEGATIVE ADJUSTABLE
VOLTAGE REGULATOR
IN CERAMIC SURFACE
MOUNT PACKAGE
FEATURES
0.76 (0.030)
0.51 (0.020)
0.33 (0.013)
Rad.
0.08 (0.003)
0.43 (0.017)
0.18 (0.007 Rad.
• –1.2V TO 47V OUTPUT VOLTAGE RANGE
• 0.5A OUTPUT CURRENT
• 1% OUTPUT VOLTAGE TOLERANCE
• 0.5% / A LOAD REGULATION
• 0.01% / V LINE REGULATION
• 0.02% / W THERMAL REGULATION
• INTERNAL PROTECTION
Pins 4,5
– Adjust
Pins 6,7,8,9,10,11,12,13 – VOUT
Pins 15,16,17,18,1,2
– VIN
Internal current and power limiting coupled with
true thermal limiting prevents device damage
due to overloads or shorts, even if the regulator
is not fastened to a heat sink.
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI–O
Input - Output Differential Voltage
– Standard
40V
– HV Series
50V
IO
Output Current
Internally limited
PD
Power Dissipation
Internally limited
TJ
Operating Junction Temperature Range
–55 to +150°C
TSTG
Storage Temperature
–65 to 150°C
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 1/99
IP137MAHV-LCC4
IP137MHV-LCC4
Parameter
IP137MAHV
IP137MA
Min.
Typ.
Max.
Test Conditions
IOUT = 10mA
VREF
Reference Voltage
∆VIN
Line Regulation 1
∆IOUT
Load Regulation 1
Thermal Regulation
Ripple Rejection
IADJ
∆IADJ
Adjust Pin Current
Adjust Pin Current
Change
Minimum Load
Current
ICL
Current Limit
∆TEMP Stability
∆VOUT
∆TIME
en
RθJC
Long Term Stability
-1.275
V
-1.220
-1.25
-1.280 -1.200
-1.25
-1.300
V
0.005
0.010
0.010
0.020
0.010
0.030
0.020
0.050
VOUT ≤ 5V
5
25
15
25
mV
VOUT ≥ 5V
0.1
0.5
0.3
0.5
%
TJ = -55 to 150°C
TJ = -55 to 150°C
%/V
IOUT = 10mA to IMAX
VOUT ≤ 5V
10
50
20
50
mV
TJ = -55 to 150°C
VOUT ≥ 5V
0.2
1
0.3
1
%
tp = 10ms
TA = 25°C
0.002
0.020
0.002
0.02
%/W
VOUT = -10V
f = 120Hz
CADJ = 0
CADJ = 10µF
TJ = -55 to 150°C
60
66
70
80
TJ = -55 to 150°C
TJ = -55 to +150°C
TJ = -55 to 150°C
TJ = -55 to 150°C
77
dB
65
100
IOUT = 10mA to IMAX
0.2
2
0.5
5
VIN – VOUT = 3V to 40V
1.0
5
2
5
2.0
6
3
6
VIN – VOUT ≤ 40V
2.5
5
2.5
5
VIN – VOUT ≤ 10V
1.2
3
1.2
3
1.5
0.50
0.80
1.5
0.15
0.17
0.10
0.17
VIN – VOUT = 3V to 50V
VIN – VOUT ≤ 15V
0.50
0.80
VIN – VOUT = 40V
0.15
0.17
0.10
0.17
0.5
0.6
1.5
0.6
0.3
1
0.3
VIN – VOUT = 50V
t = 1000 Hrs
TA = 25°C
dB
100
TA = +125°C
(% of VOUT)
66
60
65
TJ = -55 to 150°C
f = 10 Hz to 10 kHz
Junction to Case
Units
-1.25
VIN – VOUT = 3V to VMAX
RMS Output Noise
Thermal Resistance
Max.
-1.262 -1.225
(HV SERIES)
∆VOUT Temperature
Typ.
-1.25
(HV SERIES)
IMIN
Min.
-1.238
VIN – VOUT = 3V to VMAX
IOUT = 10mA to IMAX
∆VOUT
IP137MHV , IP137M
IOUT = 10mA to IMAX
P ≤ PMAX
∆VOUT
IP137MA-LCC4
IP137M-LCC4A
LCC4 Package
13
µA
mA
A
0.5
%
1
%
%
0.003
0.003
µA
13
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications.
2) Test Conditions unless otherwise stated: VIN – VOUT = 5V , IOUT = 0.1A , PMAX = 10W, IMAX = 0.5A
VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 1/99
Similar pages