TDK B32671L0332 Metallized polypropylene film capacitor Datasheet

Film Capacitors
Metallized Polypropylene Film Capacitors (MKP)
Series/Type:
B32671L ... B32672L
Date:
September 2016
© EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Metallized polypropylene film capacitors (MKP)
B32671L ... B32672L
High V AC, high temperature (wound)
Typical applications
Electronic ballasts (resonant circuits)
SMPS
High-frequency AC loads
Pulse circuits
Dimensional drawing
Climatic
Max. operating temperature: 125 °C
Climatic category (IEC 60068-1): 55/110/56
Construction
Dielectric: metallized polypropylene (PP)
Wound capacitor technology
Plastic case (UL 94 V-0)
Epoxy resin sealing
Dimensions in mm
Features
Very high AC voltages for all frequency
ranges
Very small dimensions
High peak voltage for short time periods
High peak current
High pulse withstand capability
RoHS-compatible
Halogen-free capacitors available on request
Lead spacing
±0.4
10
15
Terminals
Parallel wire leads, lead-free tinned
Special lead lengths available on request
Marking
Manufacturer's logo
lot number, series number
Rated capacitance (coded)
Capacitance tolerance (code letter)
Rated voltage
Date of manufacture (coded)
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping, refer to chapter "Taping and packing“.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 39
Lead diameter Type
d1 ±0.05
0.6
B32671L
0.8
B32672L
B32671L ... B32672L
High V AC, high temperature (wound)
Overview of available types
Lead spacing 10 mm
15 mm
Type
B32671L
B32672L
Page
4
6
VRMS (V AC)
200 250 250 500 600 700 160 200 250 250 500 600 700 900
VR (V DC)
400 630 1000 1000 1600 2000 250 450 630 1000 1300 1600 2000 2000
CR (nF)
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
33
47
56
68
100
150
220
330
390
470
680
1000
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 39
B32671L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 10 mm)
VRMS
VR
f ≤1 kHz
V AC
200
250
250
500
CR
V DC nF
400 22
33
47
68
100
630 15
22
33
47
56
1000
4.7
6.8
10
15
22
1000
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
Max. dimensions Ordering code
w×h×l
(composition see
below)
mm
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
B32671L4223+***
B32671L4333+***
B32671L4473+***
B32671L4683+***
B32671L4104+***
B32671L6153+***
B32671L6223+***
B32671L6333+***
B32671L6473+***
B32671L6563+***
B32671L9472+***
B32671L9682+***
B32671L9103+***
B32671L9153+***
B32671L9223+***
B32671L0332+***
B32671L0392+***
B32671L0472+***
B32671L0562+***
B32671L0622+***
B32671L0682+***
B32671L0822+***
B32671L0103+***
B32671L0123+***
Straight
terminals,
Ammo
pack
pcs./MOQ
4000
4000
3320
3320
2720
4000
3320
3320
2720
2720
4000
4000
3320
3320
2720
4000
4000
4000
3320
3320
3320
2720
2720
2720
Straight
Straight
terminals, terminals,
Reel
Untaped
pcs./MOQ
6800
6800
5200
5200
4400
6800
5200
5200
4400
4400
6800
6800
5200
5200
4400
6800
6800
6800
5200
5200
5200
4400
4400
4400
pcs./MOQ
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
240 = Crimped down to lead spacing 7.5 mm,
Ammo pack
140 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 4 of 39
B32671L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 10 mm)
VRMS
VR
f ≤1 kHz
V AC
600
700
CR
V DC nF
1600
1.2
1.5
2.2
2.7
3.3
3.9
4.7
2000
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
Max. dimensions Ordering code
w×h×l
(composition see
below)
mm
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
B32671L1122+***
B32671L1152+***
B32671L1222+***
B32671L1272+***
B32671L1332+***
B32671L1392+***
B32671L1472+***
B32671L8102+***
B32671L8122+***
B32671L8152+***
B32671L8222+***
B32671L8272+***
B32671L8332+***
B32671L8392+***
B32671L8472+***
Straight
terminals,
Ammo
pack
pcs./MOQ
4000
4000
3320
3320
2720
2720
2720
4000
4000
4000
3320
3320
3320
2720
2720
Straight
Straight
terminals, terminals,
Reel
Untaped
pcs./MOQ
6800
6800
5200
5200
4400
4400
4400
6800
6800
6800
5200
5200
5200
4400
4400
pcs./MOQ
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
240 = Crimped down to lead spacing 7.5 mm,
Ammo pack
140 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 5 of 39
B32672L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 15 mm)
VRMS
VR
f ≤1 kHz
V AC
160
200
250
CR
V DC nF
250 150
220
330
470
680
1000
450
68
100
150
220
330
470
680
630
33
47
68
100
150
220
390
Max. dimensions
w×h×l
mm
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
7.0 × 12.5 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
7.0 × 12.5 × 18.0
8.0 × 14.0 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
7.0 × 12.5 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
Ordering code
(composition see
below)
B32672L2154+***
B32672L2224+***
B32672L2334+***
B32672L2474+***
B32672L2684+***
B32672L2105+***
B32672L4683+***
B32672L4104+***
B32672L4154+***
B32672L4224+***
B32672L4334+***
B32672L4474+***
B32672L4684+***
B32672L6333+***
B32672L6473+***
B32672L6683+***
B32672L6104+***
B32672L6154+***
B32672L6224+***
B32672L6394+***
Straight
terminals,
Ammo
pack
pcs./MOQ
4680
3840
3320
2720
2560
4680
4680
3840
3320
2920
2560
4680
4680
3840
3320
2720
2560
Straight
terminals,
Reel
pcs./
MOQ
5200
4400
3600
2800
2800
2200
5200
5200
4400
3600
3000
2800
2200
5200
5200
4400
3600
2800
2800
2200
Straight
terminals,
Untaped
pcs./
MOQ
4000
4000
4000
2000
2000
1000
4000
4000
4000
4000
2000
2000
1000
4000
4000
4000
4000
2000
2000
1000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 6 of 39
B32672L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 15 mm)
VRMS
VR
f ≤1 kHz
V AC
250
500
600
CR
V DC nF
1000
10
15
22
33
47
68
100
150
1300
6.8
10
22
33
47
68
1600
6.2
6.8
8.2
10
12
15
22
33
47
Max. dimensions
w×h×l
mm
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
7.0 × 12.5 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
7.0 × 12.5 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
5.0 × 10.5 × 18.0
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
6.0 × 11.0 × 18.0
6.0 × 12.0 × 18.0
7.0 × 12.5 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
Ordering code
(composition see
below)
B32672L0103+***
B32672L0153+***
B32672L0223+***
B32672L0333+***
B32672L0473+***
B32672L0683+***
B32672L0104+***
B32672L0154+***
B32672L7682+***
B32672L7103+***
B32672L7223+***
B32672L7333+***
B32672L7473+***
B32672L7683+***
B32672L1622+***
B32672L1682+***
B32672L1822+***
B32672L1103+***
B32672L1123+***
B32672L1153+***
B32672L1223+***
B32672L1333+***
B32672L1473+***
Straight
terminals,
Ammo
pack
pcs./MOQ
4680
4680
4680
3840
3320
2720
2560
4680
4680
3320
2720
2560
4680
4680
3840
3840
3840
3320
2720
2560
Straight
terminals,
Reel
pcs./
MOQ
5200
5200
5200
4400
3600
2800
2800
2200
5200
5200
3600
2800
2800
2200
5200
5200
4400
4400
4400
3600
2800
2800
2200
Straight
terminals,
Untaped
pcs./
MOQ
4000
4000
4000
4000
4000
2000
2000
1000
4000
4000
4000
2000
2000
1000
4000
4000
4000
4000
4000
4000
2000
2000
1000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 7 of 39
B32672L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 15 mm)
VRMS
VR
f ≤1 kHz
V AC
700
CR
Max. dimensions
w×h×l
Ordering code
(composition see
below)
mm
V DC nF
2000
1.0 5.0 × 10.5 × 18.0 B32672L8102+***
1.2 5.0 × 10.5 × 18.0 B32672L8122+***
1.5 5.0 × 10.5 × 18.0 B32672L8152+***
2.2 5.0 × 10.5 × 18.0 B32672L8222+***
2.7 5.0 × 10.5 × 18.0 B32672L8272+***
3.3 5.0 × 10.5 × 18.0 B32672L8332+***
3.9 5.0 × 10.5 × 18.0 B32672L8392+***
4.7 5.0 × 10.5 × 18.0 B32672L8472+***
5.6 6.0 × 11.0 × 18.0 B32672L8562+***
6.2 6.0 × 11.0 × 18.0 B32672L8622+***
6.8 6.0 × 11.0 × 18.0 B32672L8682+***
8.2 6.0 × 12.0 × 18.0 B32672L8822+***
10
7.0 × 12.5 × 18.0 B32672L8103+***
12
8.5 × 14.5 × 18.0 B32672L8123+***
15
8.5 × 14.5 × 18.0 B32672L8153+***
22
9.0 × 17.5 × 18.0 B32672L8223+***
33
11.0 × 18.5 × 18.0 B32672L8333+***
Straight
terminals,
Ammo
pack
pcs./MOQ
4680
4680
4680
4680
4680
4680
4680
4680
3840
3840
3840
3840
3320
2720
2720
2560
Straight
terminals,
Reel
pcs./
MOQ
5200
5200
5200
5200
5200
5200
5200
5200
4400
4400
4400
4400
3600
2800
2800
2800
2200
Straight
terminals,
Untaped
pcs./
MOQ
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
2000
2000
2000
1000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 8 of 39
B32672L
High V AC, high temperature (wound)
Ordering codes and packing units (lead spacing 15 mm)
VRMS
VR
f ≤1 kHz
V AC
900
CR
V DC nF
2000
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
Max. dimensions
w×h×l
mm
5.0 × 10.5 × 18.0
6.0 × 11.0 × 18.0
6.0 × 11.0 × 18.0
7.0 × 12.5 × 18.0
8.0 × 14.0 × 18.0
8.5 × 14.5 × 18.0
9.0 × 17.5 × 18.0
9.0 × 17.5 × 18.0
11.0 × 18.5 × 18.0
11.0 × 18.5 × 18.0
11.0 × 18.5 × 18.0
Ordering code
(composition see
below)
B32672L9102+***
B32672L9122+***
B32672L9152+***
B32672L9222+***
B32672L9272+***
B32672L9332+***
B32672L9392+***
B32672L9472+***
B32672L9562+***
B32672L9622+***
B32672L9682K***
Straight
terminals,
Ammo
pack
pcs./MOQ
4680
3840
3840
3320
2920
2720
2560
2560
Straight
terminals,
Reel
pcs./
MOQ
5200
4400
4400
3600
3000
2800
2800
2800
2200
2200
2200
Straight
terminals,
Untaped
pcs./
MOQ
4000
4000
4000
4000
2000
2000
2000
2000
1000
1000
1000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerances on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 9 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Technical data
Reference standard: IEC 60384-16. All data given at T = 20 °C, otherwise is specified.
Operating temperature
range
Max. operating temperature Top,max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
Dissipation factor tan δ
(in 10-3) at 20 °C
(upper limit values)
at
Insulation resistance Rins
or time constant
τ = CR Rins at 20 °C,
rel. humidity ≤ 65%
(minimum as-delivered
values)
DC test voltage
≤27 nF 27 nF< CR ≤0.1 μF 0.1 μF < CR ≤1 μF
0.8
1 kHz 0.8
10 kHz 1.0
1.0
100 kHz 2.0
3.0
100 GΩ (CR ≤ 0.33 μF)
30000 s (CR > 0.33 μF)
1.6 VR, 2 s
Top (°C)
DC voltage derating
Category voltage VC
(continuous operation
Top ≤ 85
VC = VR
with VDC or VAC at f ≤1 kHz) 85<Top≤110 VC = VR (165Top)/80
Operating voltage Vop for
short operating periods
(VDC or VAC at f ≤1 kHz)
Reliability:
Failure rate λ
Service life tSL
Failure criteria:
Total failure
Failure due to variation
of parameters
+125 °C
+110 °C
55 °C
+85 °C
Top (°C)
DC voltage (max. hours)
Top ≤ 100
Vop = 1.25 VC (2000 h)
100<Top≤125 Vop = 1.25 VC (1000 h)
0.8
1.0
>1 μF
0.8
AC voltage derating
VC,RMS = VRMS
VC,RMS=VRMS (165Top)/80
AC voltage (max. hours)
Vop = 1.0 VC,RMS (2000 h)
Vop = 1.0 VC,RMS (1000 h)
1 fit (≤ 1 10-9/h) at 0.5 VR, 40 °C
200 000 h at 1.0 VR, 85 °C
For conversion to other operating conditions and temperatures, refer
to chapter "Quality, 2 Reliability".
Short circuit or open circuit
Capacitance change ΔC/C
Dissipation factor tan δ
Insulation resistance Rins
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 39
> 10%
> 4 upper limit values
< 1500 MΩ
B32671L ... B32672L
High V AC, high temperature (wound)
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/μs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/μs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor. These parameters are given for isolated pulses in such a way that the heat generated
by one pulse will be completely dissipated before applying the next pulse. For a train of pulses,
please refer to the curves of permissible AC voltage-current versus frequency.
dV/dt values
Lead spacing
Type
VRMS (V AC)
VR (V DC)
CR (nF)
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
33
47
56
68
100
10 mm
B32671L
200
250
400
630
dV/dt in V/μs
540
400
540
400
540
400
540
540
400
400
Please read Cautions and warnings and
Important notes at the end of this document.
1000
500
1000
810
810
810
810
810
Page 11 of 39
4700
4300
3800
3400
3200
3100
2700
2500
2300
600
1600
6000
5600
5200
5000
4700
4500
4000
700
2000
11000
10000
9500
9000
8600
8500
8200
8000
B32671L ... B32672L
High V AC, high temperature (wound)
dV/dt values
Lead spacing 15 mm
Type
B32672L
VRMS (V AC)
160
200
VR (V DC)
250
450
CR (nF)
dV/dt in V/μs
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
33
47
56
68
200
100
200
150
170
200
220
170
200
330
170
200
390
470
170
200
680
170
200
1000
170
Please read Cautions and warnings and
Important notes at the end of this document.
630
250
1000
500
1300
600
1600
700
2000
900
2000
300
300
300
300
300
300
300
445
445
445
445
445
445
445
445
1000
1000
1000
1000
1000
1000
3600
3500
3100
2800
2600
2300
2000
1700
1400
10000
9400
9000
7500
7100
6800
6000
5500
5000
4700
4500
4200
3900
3600
3300
2900
2300
15000
14100
13500
11000
10600
10000
9000
8200
7500
7000
6700
Page 12 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
k0 values
Lead spacing 10 mm
Type
B32671L
VRMS (V AC)
200
VR (V DC)
400
CR (nF)
k0 in V2/μs
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
150000
33
150000
47
150000
56
68
150000
100
150000
250
630
1000
200000
200000
200000
200000
200000
400000
400000
400000
400000
400000
Please read Cautions and warnings and
Important notes at the end of this document.
500
1000
9400000
8600000
8200000
7600000
6800000
6200000
5400000
5000000
4600000
Page 13 of 39
600
1600
14400000
14000000
13800000
13600000
13300000
13100000
12000000
700
2000
25000000
23000000
22500000
22000000
21500000
21000000
20900000
20800000
B32671L ... B32672L
High V AC, high temperature (wound)
k0 values
Lead spacing
Type
VRMS (V AC)
VR (V DC)
CR (nF)
1.0
1.2
1.5
2.2
2.7
3.3
3.9
4.7
5.6
6.2
6.8
8.2
10
12
15
22
33
47
56
68
100
150
220
330
390
470
680
1000
15 mm
B32672L
160
200
250
450
k0 in V2/μs
120000
120000
100000 120000
100000 120000
100000 120000
100000 120000
100000
100000
Please read Cautions and warnings and
Important notes at the end of this document.
250
630
1000
500000
500000
500000
500000
500000
500000
500000
1000000
1000000
1000000
1000000
1000000
1000000
1000000
1000000
500
1300
700
2000
900
2000
20300000
19600000
19200000
18600000
18200000
18000000
16800000
15800000
13100000
11520000 12700000
3000000 11200000 12300000
9920000 11800000
3000000 8960000 11100000
8320000 10600000
7360000 10400000
3000000 6400000 9300000
3000000 5440000 9000000
3000000 4480000
3000000
30000000
29400000
28000000
27500000
27300000
27000000
25200000
23500000
19500000
19000000
18400000
Page 14 of 39
600
1600
B32671L ... B32672L
High V AC, high temperature (wound)
Impedance Z versus frequency f (typical values)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 39
B32671L
High V AC, high temperature (wound)
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
400 V DC/200 V AC
630 V DC/250 V AC
1000 V DC/250 V AC
1000 V DC/500 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 39
B32671L
High V AC, high temperature (wound)
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
1600 V DC/600 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
2000 V DC/700 V AC
Page 17 of 39
B32672L
High V AC, high temperature (wound)
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
250 V DC/160 V AC
450 V DC/200 V AC
630 V DC/250 V AC
1000 V DC/250 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 18 of 39
B32672L
High V AC, high temperature (wound)
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
1300 V DC/500 V AC
1600 V DC/600 V AC
2000 V DC/700 V AC
2000 V DC/900 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 19 of 39
B32671L
High V AC, high temperature (wound)
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
400 V DC/200 V AC
630 V DC/250 V AC
1000 V DC/250 V AC
1000 V DC/500 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 39
B32671L
High V AC, high temperature (wound)
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 10 mm
1600 V DC/600 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
2000 V DC/700 V AC
Page 21 of 39
B32672L
High V AC, high temperature (wound)
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
250 V DC/160 V AC
450 V DC/200 V AC
630 V DC/250 V AC
1000 V DC/250 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 39
B32672L
High V AC, high temperature (wound)
Permissible current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA >100 °C, please use derating factor FT.
Lead spacing 15 mm
1300 V DC/500 V AC
1600 V DC/600 V AC
2000 V DC/700 V AC
2000 V DC/900 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 23 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Maximum AC voltage (VRMS), current (IRMS) vs. frequency and temperature for TA > 100 ºC
The graphs described in the previous section for the permissible AC voltage (VRMS) or current
(IRMS) vs. frequency are given for a maximum ambient temperature TA ≤100 ºC. In case of higher
ambient temperatures (TA), the self-heating (ΔT) of the component must be reduced to avoid that
temperature of the component (Top= TA + ΔT) reaches values above maximum operating
temperature.The factor FT shall be applied in the following way:
And FT is given by the following curve:
Please read Cautions and warnings and
Important notes at the end of this document.
Page 24 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Operation at overvoltages during heating and ignition of lamps (TA ≤40 °C)
In lighting applications, the capacitors can be subjected to overvoltages during the heating and ignition periods. An overvoltage occurs when the operation voltage exceeds the permissible
AC voltage at the resonant frequency fr.
For a repetitive application of on/off switching pulses (as for example in the life tests applied by
electronic ballast manufacturers), limits have to be imposed on the time periods under overvoltage and on the duty cycle, in order to keep the capacitance value within the required margins:
The overvoltage time tOV should be less than 1 sec.
The K0 calculated in the overvoltage period (see general technical information) shall be lower
than the maximum K0 provided.
The maximum duty cycle of the overvoltage is given by
where VRMS,ov is the RMS voltage during period tOV
and VRMS is the permissible AC voltage for continuous operation at the resonant frequency fr
(given by the “permissible AC voltage versus frequency f” graphics in theprevious pages).
The drift of capacitance depends on the Vpp attained, and the total time under overvoltage,
which is calculated in hours as follows:
(Ni tOV) / 3600
where Ni is the number of overvoltage impulses and tOV is expressed in seconds.
The maximum drift of capacitance as a function of both parameters is provided graphically in the
following pages.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 25 of 39
B32671L
High V AC, high temperature (wound)
Estimation of the maximum drift of capacitance value in function of the number of total
hours overvoltage
Lead spacing 10 mm
500 V AC/1000 V DC
Please read Cautions and warnings and
Important notes at the end of this document.
600 V AC/1600 V DC
Page 26 of 39
B32672L
High V AC, high temperature (wound)
Estimation of the maximum drift of capacitance value in function of the number of total
hours overvoltage
Lead spacing 15 mm
600 V AC/1600 V DC
Please read Cautions and warnings and
Important notes at the end of this document.
700 V AC/2000 V DC
Page 27 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Testing and Standards
Test
Reference
Conditions of test
Performance requirements
Electrical
Parameters
IEC 60384-16
Within specified limits
Robustness
of terminations
IEC 60068-2-21
Voltage proof, 1.6 VR, 1 minute
Insulation resistance, RINS
Capacitance, C
Dissipation factor, tan δ
Tensile strength (test Ua1)
Tensile
force
Wire diameter
0.5 < d1 ≤ 0.8 mm 10 N
Resistance to IEC 60068-2-20, Solder bath temperature at
test Tb,
260 ± 5 °C, immersion for
soldering
method 1A
10 seconds
heat
Capacitance and tan δ
within specified limits
ΔC/C0 ≤ 2%
|Δ tan δ| ≤ 0.002
Rapid
change of
temperature
IEC 60384-16
TA = lower category temperature
TB = upper category temperature
Five cycles, duration t = 30 min.
Vibration
IEC 60384-16
Bump
IEC 60384-16
Climatic
sequence
IEC 60384-16
Damp Heat
Steady State
IEC 60384-16
Test Fc: vibration sinusoidal
No visible damage
Displacement: 0.75 mm
Accleration: 98 m/s2
Frequency: 10 Hz ... 500 Hz
Test duration: 3 orthogonal axes,
2 hours each axe
Test Eb: Total 4000 bumps with No visible damage
|ΔC/C0| ≤ 2%
390 m/s2 mounted on PCB
|Δ
tan δ| ≤ 0.002
6 ms duration
RINS ≥ 50% of initial limit
Dry heat Tb / 16 h.
No visible damage
Damp heat cyclic, 1st cycle
|ΔC/C0| ≤ 3%
+55 °C / 24h / 95% ... 100% RH |Δ tan δ| ≤ 0.001
Cold Ta / 2h
RINS ≥ 50% of initial limit
Damp heat cyclic, 5 cycles
+55 °C / 24h / 95% ... 100% RH
Test Ca
No visible damage
40 °C / 93% RH / 56 days
|ΔC/C0| ≤ 3%
|Δ tan δ| ≤ 0.001
RINS ≥ 50% of initial limit
No visible damage
60 °C / 95% RH / 1000 hours
|ΔC/C0| ≤ 10%
with VR,DC
|Δ tan δ| ≤ 0.002
RINS ≥ 50% of initial limit
High
temperature
high humidity
with load
Please read Cautions and warnings and
Important notes at the end of this document.
Page 28 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Test
Reference
Conditions of test
Endurance
IEC60384-16
85 °C/ 1.25 VR / 2000 hours
Endurance
IEC60384-16
110 °C/ 1.25 VC / 2000 hours
Performance requirements
No visible damage
|ΔC/C0| ≤ 5%
|Δ tan δ| ≤ 0.002
RINS ≥ 50% of initial limit
No visible damage
|ΔC/C0| ≤ 10%
|Δ tan δ| ≤ 0.002
RINS ≥ 50% of initial limit
Mounting guidelines
1
Soldering
1.1
Solderability of leads
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far
higher than the upper category temperature of the capacitors, the terminal wires should be cut off
from the capacitor before the ageing procedure to prevent the solderability being impaired by the
products of any capacitor decomposition that might occur.
Solder bath temperature
235 ±5 °C
Soldering time
2.0 ±0.5 s
Immersion depth
2.0 +0/0.5 mm from capacitor body or seating plane
Evaluation criteria:
Visual inspection
Wetting of wire surface by new solder ≥90%, free-flowing solder
Please read Cautions and warnings and
Important notes at the end of this document.
Page 29 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
1.2
Resistance to soldering heat
Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A.
Conditions:
Series
Solder bath temperature Soldering time
MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C
coated
uncoated (lead spacing > 10 mm)
MFP
MKP (lead spacing > 7.5 mm)
MKT boxed (case 2.5 × 6.5 × 7.2 mm)
MKP (lead spacing ≤ 7.5 mm)
MKT uncoated (lead spacing ≤ 10 mm)
insulated (B32559)
10 ±1 s
5 ±1 s
<4s
recommended soldering
profile for MKT uncoated
(lead spacing ≤ 10 mm) and
insulated (B32559)
Immersion depth
2.0 +0/0.5 mm from capacitor body or seating plane
Shield
Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor
body and liquid solder
Evaluation criteria:
Visual inspection
ΔC/C0
tan δ
Please read Cautions and warnings and
Important notes at the end of this document.
No visible damage
2% for MKT/MKP/MFP
5% for EMI suppression capacitors
As specified in sectional specification
Page 30 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
1.3
General notes on soldering
Permissible heat exposure loads on film capacitors are primarily characterized by the upper category temperature Tmax. Long exposure to temperatures above this type-related temperature limit
can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical
characteristics. For short exposures (as in practical soldering processes) the heat load (and thus
the possible effects on a capacitor) will also depend on other factors like:
Pre-heating temperature and time
Forced cooling immediately after soldering
Terminal characteristics:
diameter, length, thermal resistance, special configurations (e.g. crimping)
Height of capacitor above solder bath
Shadowing by neighboring components
Additional heating due to heat dissipation by neighboring components
Use of solder-resist coatings
The overheating associated with some of these factors can usually be reduced by suitable countermeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced
cooling process may possibly have to be included.
EPCOS recommendations
As a reference, the recommended wave soldering profile for our film capacitors is as follows:
Please read Cautions and warnings and
Important notes at the end of this document.
Page 31 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Body temperature should follow the description below:
MKP capacitor
During pre-heating: Tp ≤ 110 °C
During soldering: Ts ≤ 120 °C, ts ≤ 45 s
MKT capacitor
During pre-heating: Tp ≤ 125 °C
During soldering: Ts ≤ 160 °C, ts ≤ 45 s
When SMD components are used together with leaded ones, the film capacitors should not pass
into the SMD adhesive curing oven. The leaded components should be assembled after the SMD
curing step.
Leaded film capacitors are not suitable for reflow soldering.
In order to ensure proper conditions for manual or selective soldering, the body temperature of
the capacitor (Ts) must be ≤ 120 °C.
One recommended condition for manual soldering is that the tip of the soldering iron should
be < 360 °C and the soldering contact time should be no longer than 3 seconds.
For uncoated MKT capacitors with lead spacings ≤ 10 mm (B32560/B32561) the following measures are recommended:
pre-heating to not more than 110 °C in the preheater phase
rapid cooling after soldering
Please refer to EPCOS Film Capacitor Data Book in case more details are needed.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 32 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Cautions and warnings
Do not exceed the upper category temperature (UCT).
Do not apply any mechanical stress to the capacitor terminals.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after it has been soldered to the PC board.
Do not pick up the PC board by the soldered capacitor.
Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified
lead spacing.
Do not exceed the specified time or temperature limits during soldering.
Avoid external energy inputs, such as fire or electricity.
Avoid overload of the capacitors.
The table below summarizes the safety instructions that must always be observed. A detailed
description can be found in the relevant sections of the chapters "General technical information"
and "Mounting guidelines".
Topic
Storage
conditions
Flammability
Resistance to
vibration
Safety information
Reference chapter
"General technical
information"
Make sure that capacitors are stored within the specified 4.5
range of time, temperature and humidity conditions.
"Storage conditions"
Avoid external energy, such as fire or electricity (passive 5.3
flammability), avoid overload of the capacitors (active
"Flammability"
flammability) and consider the flammability of materials.
Do not exceed the tested ability to withstand vibration.
5.2
The capacitors are tested to IEC 60068-2-6.
"Resistance to
EPCOS offers film capacitors specially designed for
vibration"
operation under more severe vibration regimes such as
those found in automotive applications. Consult our
catalog "Film Capacitors for Automotive Electronics".
Topic
Safety information
Soldering
Do not exceed the specified time or temperature limits
during soldering.
Use only suitable solvents for cleaning capacitors.
When embedding finished circuit assemblies in plastic
resins, chemical and thermal influences must be taken
into account.
Caution: Consult us first, if you also wish to embed other
uncoated component types!
Cleaning
Embedding of
capacitors in
finished
assemblies
Please read Cautions and warnings and
Important notes at the end of this document.
Page 33 of 39
Reference chapter
"Mounting guidelines"
1 "Soldering"
2 "Cleaning"
3 "Embedding of
capacitors in finished
assemblies"
B32671L ... B32672L
High V AC, high temperature (wound)
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications and the website of EPCOS, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the
specifications of the respective products. Detailed information can be found on the Internet
under www.epcos.com/orderingcodes.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 34 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Symbols and terms
Symbol
α
αC
A
βC
C
CR
ΔC
ΔC/C
ΔC/CR
dt
Δt
ΔT
Δtan δ
ΔV
dV/dt
ΔV/Δt
E
ESL
ESR
f
f1
f2
fr
FD
FT
i
IC
English
Heat transfer coefficient
Temperature coefficient of capacitance
Capacitor surface area
Humidity coefficient of capacitance
Capacitance
Rated capacitance
Absolute capacitance change
Relative capacitance change (relative
deviation of actual value)
Capacitance tolerance (relative deviation
from rated capacitance)
Time differential
Time interval
Absolute temperature change
(self-heating)
Absolute change of dissipation factor
Absolute voltage change
Time differential of voltage function (rate
of voltage rise)
Voltage change per time interval
Activation energy for diffusion
Self-inductance
Equivalent series resistance
Frequency
Frequency limit for reducing permissible
AC voltage due to thermal limits
German
Wärmeübergangszahl
Temperaturkoeffizient der Kapazität
Kondensatoroberfläche
Feuchtekoeffizient der Kapazität
Kapazität
Nennkapazität
Absolute Kapazitätsänderung
Relative Kapazitätsänderung (relative
Abweichung vom Ist-Wert)
Kapazitätstoleranz (relative Abweichung
vom Nennwert)
Differentielle Zeit
Zeitintervall
Absolute Temperaturänderung
(Selbsterwärmung)
Absolute Änderung des Verlustfaktors
Absolute Spannungsänderung
Differentielle Spannungsänderung
(Spannungsflankensteilheit)
Spannungsänderung pro Zeitintervall
Aktivierungsenergie zur Diffusion
Eigeninduktivität
Ersatz-Serienwiderstand
Frequenz
Grenzfrequenz für thermisch bedingte
Reduzierung der zulässigen
Wechselspannung
Frequency limit for reducing permissible Grenzfrequenz für strombedingte
AC voltage due to current limit
Reduzierung der zulässigen
Wechselspannung
Resonant frequency
Resonanzfrequenz
Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur
Diffusion
Derating factor
Deratingfaktor
Current (peak)
Stromspitze
Category current (max. continuous
Kategoriestrom (max. Dauerstrom)
current)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 35 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Symbol
IRMS
iz
k0
LS
λ
λ0
λtest
Pdiss
Pgen
Q
ρ
R
R
Ri
Rins
RP
RS
S
t
T
τ
tan δ
tan δD
tan δP
tan δS
TA
Tmax
Tmin
tOL
Top
TR
Tref
tSL
English
(Sinusoidal) alternating current,
root-mean-square value
Capacitance drift
Pulse characteristic
Series inductance
Failure rate
Constant failure rate during useful
service life
Failure rate, determined by tests
Dissipated power
Generated power
Heat energy
Density of water vapor in air
Universal molar constant for gases
Ohmic resistance of discharge circuit
Internal resistance
Insulation resistance
Parallel resistance
Series resistance
severity (humidity test)
Time
Temperature
Time constant
Dissipation factor
Dielectric component of dissipation
factor
Parallel component of dissipation factor
Series component of dissipation factor
Temperature of the air surrounding the
component
Upper category temperature
Lower category temperature
Operating life at operating temperature
and voltage
Operating temperature
Rated temperature
Reference temperature
Reference service life
Please read Cautions and warnings and
Important notes at the end of this document.
German
(Sinusförmiger) Wechselstrom
Inkonstanz der Kapazität
Impulskennwert
Serieninduktivität
Ausfallrate
Konstante Ausfallrate in der
Nutzungsphase
Experimentell ermittelte Ausfallrate
Abgegebene Verlustleistung
Erzeugte Verlustleistung
Wärmeenergie
Dichte von Wasserdampf in Luft
Allg. Molarkonstante für Gas
Ohmscher Widerstand des
Entladekreises
Innenwiderstand
Isolationswiderstand
Parallelwiderstand
Serienwiderstand
Schärfegrad (Feuchtetest)
Zeit
Temperatur
Zeitkonstante
Verlustfaktor
Dielektrischer Anteil des Verlustfaktors
Parallelanteil des Verlfustfaktors
Serienanteil des Verlustfaktors
Temperatur der Luft, die das Bauteil
umgibt
Obere Kategorietemperatur
Untere Kategorietemperatur
Betriebszeit bei Betriebstemperatur und
-spannung
Beriebstemperatur
Nenntemperatur
Referenztemperatur
Referenz-Lebensdauer
Page 36 of 39
B32671L ... B32672L
High V AC, high temperature (wound)
Symbol
VAC
VC
VC,RMS
English
AC voltage
Category voltage
Category AC voltage
VCD
Vch
VDC
VFB
Vi
Vo
Vop
Vp
Vpp
VR
Corona-discharge onset voltage
Charging voltage
DC voltage
Fly-back capacitor voltage
Input voltage
Output voltage
Operating voltage
Peak pulse voltage
Peak-to-peak voltage Impedance
Rated voltage
Amplitude of rated AC voltage
R
VRMS
German
Wechselspannung
Kategoriespannung
(Sinusförmige)
Kategorie-Wechselspannung
Teilentlade-Einsatzspannung
Ladespannung
Gleichspannung
Spannung (Flyback)
Eingangsspannung
Ausgangssspannung
Betriebsspannung
Impuls-Spitzenspannung
Spannungshub
Nennspannung
Amplitude der Nenn-Wechselspannung
VSC
Vsn
(Sinusoidal) alternating voltage,
root-mean-square value
S-correction voltage
Snubber capacitor voltage
Z
Impedance
Spannung bei Anwendung "S-correction"
Spannung bei Anwendung
"Beschaltung"
Scheinwiderstand
Lead spacing
Rastermaß
Please read Cautions and warnings and
Important notes at the end of this document.
(Sinusförmige) Wechselspannung
Page 37 of 39
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
Page 38 of 39
Important notes
7. The trade names EPCOS, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS,
DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD,
MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT,
SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 39 of 39
Similar pages