Total Power MIHW1013 Reinforced insulation rated for 300vac working voltage Datasheet

FEATURES
►Reinforced Insulation rated for 300VAC Working Voltage
►I/O-isolation Voltage 4000VACrms
►Industrial & Medical Safety Approval
►Wide 2:1 Input Voltage Range
►Fully regulated Output Voltage
►Low Leakage Current
►Operating Temp. Range –40°C to +85 °C
►Input Filter meets EN 55022, class A
►Overload Protection
►3 Year Product Warranty
PRODUCT OVERVIEW
The MIHW1000 series is a range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is
specified for 4000VACrms.The product comes in a small DIP-24 package. All 20 models features wide 2:1 input voltage range and fully regulated output
voltage.
The MIHW1000 DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified
supplementary or reinforced insulation system to comply with relative industrial or medical safety standards.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MIHW1002
MIHW1003
MIHW1008
MIHW1006
MIHW1007
MIHW1012
MIHW1013
MIHW1018
MIHW1016
MIHW1017
MIHW1022
MIHW1023
MIHW1028
MIHW1026
MIHW1027
MIHW1032
MIHW1033
MIHW1038
MIHW1036
MIHW1037
5
(4.5 ~ 9)
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
VDC
5
12
24
±12
±15
5
12
24
±12
±15
5
12
24
±12
±15
5
12
24
±12
±15
Output Current
Input Current
Reflected
Max. capacitive
Ripple
Load
Max.
Min.
@Max. Load
@No Load
Current
mA
600
250
125
±125
±100
600
250
125
±125
±100
600
250
125
±125
±100
600
250
125
±125
±100
mA
90
37.5
18.8
±18.8
±15
90
37.5
18.8
±18.8
±15
90
37.5
18.8
±18.8
±15
90
37.5
18.8
±18.8
±15
mA(typ.)
857
800
800
800
800
338
313
313
313
313
160
151
151
151
151
80
75
75
75
75
mA(typ.)
mA (typ.)
40
60
30
30
20
15
10
10
Toll Free: 877-646-0900
(typ.)
@Max. Load
uF
1000
470
470
220#
220#
1000
470
470
220#
220#
1000
470
470
220#
220#
1000
470
470
220#
220#
# For each output
In
Total Power International,
Inc
Efficiency
www.total-power.com
%
70
75
76
75
75
74
80
81
80
80
78
83
84
83
83
78
83
84
83
83
MIHW1000 SERIES
Tota
Total Power International, Inc. DC/DC CONVERTER 3W, Reinforced
Insulation, Medical Safety
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
Min.
-0.7
Typ.
5V Input Models
Model
---
Max.
11
12V Input Models
-0.7
---
25
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
5V Input Models
12V Input Models
24V Input Models
48V Input Models
5V Input Models
12V Input Models
24V Input Models
48V Input Models
3.7
4
4.5
8
8.5
9
VDC
15
17
18
30
33
36
----4
----8.5
----17
----34
----0.3
A
----2000
mW
----2500
mW
Compliance to EN 55022,class A and FCC part 15,class A
All Models
Unit
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
Min.
----------------------120
Continuous
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=25% to 100%
5V Output Models
Other Output Models
Over Line, Load & Temp.
25% Load Step Change
Foldback
Typ.
±0.5
±0.5
±0.3
±0.5
75
100
----150
±3
±0.02
150
Max.
±1.0
±2.0
±0.5
±1.0
100
150
180
15
500
±6
±0.05
---
Unit
%
%
%
%
mV P-P
mV P-P
mV P-P
mV rms
uS
%
%/℃
%
Max.
----2
--13
Unit
VACrms
VPK
uA
GΩ
pF
Isolation, Safety Standards
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Test Voltage
Leakage Current
I/O Isolation Resistance
I/O Isolation Capacitance
Conditions
60 Seconds
Flash tested for 1 Second
240VAC, 60Hz
500 VDC
100KHz, 1V
Min.
Typ.
4000
--6000
------10
----7
cUL/UL60950-1, CSA C22.2 No. 60950-1-03
UL60601-1,CSA C22.2 No.601-1
IEC/EN 60950-1, IEC/EN 60601-1
IEC60950-1 CB report, cUL/UL 60950-1 certificate
UL60601-1 UL certificate
Safety Standards
Approvals
General Specifications
Parameter
Conditions
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Min.
Typ.
Max.
Unit
---
150
---
KHz
1,000,000
---
---
Hours
Input Fuse
5V Input Models
12V Input Models
24V Input Models
48V Input Models
2000mA Slow-Blow Type
1000mA Slow-Blow Type
500mA Slow-Blow Type
250mA Slow-Blow Type
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MIHW1000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---50
--Free-Air convection
---
Max.
+85
+95
+125
95
Unit
℃
℃
℃
% rel. H
260
℃
Power Derating Curve
100
Natural
convection
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
Ripple & Noise measurement bandwidth is 0-20 MHz.
4
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
5
All DC/DC converters should be externally fused at the front end for protection.
6
Other input and output voltage may be available, please contact factory.
7
Specifications subject to change without notice.
however, they may not meet all specifications listed.
Package Specifications
0.2 [0.008]
Pin Connections
3.9 10.5 [0.41]
[0.15]
Mechanical Dimensions
0.60 [0.024]
12
Bottom View
15
23
20.32 [0.80]
2.54
[0.10]
31.8 [1.25]
+Vin
+Vin
11
No Pin
Common
12
-Vout
No Pin
13
+Vout
-Vout
15
No Pin
+Vout
23
-Vin
-Vin
24
-Vin
-Vin
5.08
[0.20]
2.0
[0.08]
►All
dimensions in mm (inches)
►Tolerance: X.X±0.25
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter  0.6 ±0.05 (0.024±0.002)
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
31.8x20.3x10.5mm (1.25x0.8x0.41 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
16.2g
In
Total Power International,
Inc
Dual Output
13
2.54
[0.10]
24
Single Output
1
20.3 [0.80]
11
15.22 [0.60]
1
Pin
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MIHW1000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Resistive
Load
Scope
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Design & Feature Considerations
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. Capacitor
mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100
kHz) capacitor of a 10uF for the 5V input devices and a 4.7uF for the 12V input devices and 2.2uF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
+
Cout
+Vin
DC Power
Source
Load
-Out
-
+Out
Dual Output
Com.
DC / DC
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MIHW1000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data
sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com
Similar pages