FAB0501012 FEATURES 6U x 19’’ x 305mm INPUT : 185 - 264Vac OUTPUT : 115Vac 400Hz 500W 28Vdc 100W 28Vdc 100W Efficiency : 80 % typ. APPLICATIONS Test bench. INPUT Voltage range : 185 - 264Vac Nominal : 230 Vac 50Hz Input protection : fuse 5A transient and surges protected OUTPUT Output : 115Vac 400Hz 500W 28Vdc 100W 28Vdc 100W 115Vac 400Hz Typ. Line regulation 2% Load regulation 3% Ripple and noise Current limit Rev. 00 105 % of I nominal Max. 4% 28Vdc A 28Vdc B Typ. Max. Typ. Max. 2% 5% 2% 5% 2% 5% 2% 5% 2% 2% 150 % of I nominal 150 % of I nominal 1/3 Conditions Low line to high line ; full load 10 % to full load Peak to peak Bandwidth 20MHz according to o/p voltage Vout = 95 % of nominal ; Automatic restart FAB0501012 SIGNALS Remote ON/OFF : TTL high signal to inhibit 28Vdc A et B Output OK : front panel indicator for every output ENVIRONMENTAL Storage temperature : -40°C to +85°C Operating temperature : 0°C to +50°C ambiant, nominal power ISOLATION Input to Chassis : 1500 Vrms or 2121 Vdc Input to Output : 3000 Vrms or 4242 Vdc Output to Chassis : >100 Mohms at 500 Vdc GENERAL Safety : built to meet EN60950 EMI : built to meet EN55022B, conducted. Rev. 00 2/3 FAB0501012 MECHANICALS 115Vac 400Hz output A and B : JAEGER ref. 5366 030 06 Input fuse 5A PIN 1 DESCRIPTION 2 AC/N 3 Ground AC/L 28Vdc output A and B : JAEGER ref. 5366 040 06 PIN 1 DESCRIPTION 2 0V 3 0V 4 +Vout +Vout Main switch ON/OFF and CE22 connector Remote control : SubD female 9pts Rev. 00 3/3 PIN 1 DESCRIPTION -Inhibit 28V output A 2 +Inhibit 28V output A 3 -Inhibit 28V output B 4 +Inhibit 28V output B 5-9 NC