PST FAB0501012 Test bench Datasheet

FAB0501012
FEATURES
6U x 19’’ x 305mm
INPUT : 185 - 264Vac
OUTPUT : 115Vac 400Hz 500W
28Vdc 100W
28Vdc 100W
Efficiency : 80 % typ.
APPLICATIONS
Test bench.
INPUT
Voltage range :
185 - 264Vac
Nominal :
230 Vac 50Hz
Input protection :
fuse 5A
transient and surges protected
OUTPUT
Output :
115Vac 400Hz 500W
28Vdc 100W
28Vdc 100W
115Vac 400Hz
Typ.
Line regulation
2%
Load regulation
3%
Ripple and noise
Current limit
Rev. 00
105 %
of I nominal
Max.
4%
28Vdc A
28Vdc B
Typ.
Max.
Typ.
Max.
2%
5%
2%
5%
2%
5%
2%
5%
2%
2%
150 %
of I nominal
150 %
of I nominal
1/3
Conditions
Low line to high line ;
full load
10 % to full load
Peak to peak Bandwidth 20MHz
according to o/p voltage
Vout = 95 % of nominal
; Automatic restart
FAB0501012
SIGNALS
Remote ON/OFF : TTL high signal to inhibit 28Vdc A et B
Output OK : front panel indicator for every output
ENVIRONMENTAL
Storage temperature :
-40°C to +85°C
Operating temperature :
0°C to +50°C ambiant, nominal power
ISOLATION
Input to Chassis :
1500 Vrms or 2121 Vdc
Input to Output :
3000 Vrms or 4242 Vdc
Output to Chassis :
>100 Mohms at 500 Vdc
GENERAL
Safety :
built to meet EN60950
EMI :
built to meet EN55022B, conducted.
Rev. 00
2/3
FAB0501012
MECHANICALS
115Vac 400Hz output A and B :
JAEGER ref. 5366 030 06
Input fuse 5A
PIN
1
DESCRIPTION
2
AC/N
3
Ground
AC/L
28Vdc output A and B :
JAEGER ref. 5366 040 06
PIN
1
DESCRIPTION
2
0V
3
0V
4
+Vout
+Vout
Main switch ON/OFF and CE22 connector
Remote control :
SubD female 9pts
Rev. 00
3/3
PIN
1
DESCRIPTION
-Inhibit 28V output A
2
+Inhibit 28V output A
3
-Inhibit 28V output B
4
+Inhibit 28V output B
5-9
NC
Similar pages