DB Lectro HL2E470KT Aluminium electrolytic capacitor Datasheet

HL Series
RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR
FEATURES
◆
◆
◆ Safety vent construction design
Load life of 5000 hours at 105°C
For electronic ballast circuits, switching power supply, automotive and other
long life required applications
OUTLINE
mm
D
10
13
16
18
F
5.0
7.5
d
0.6
0.8
SPECIFICATIONS
Items
Characteristics
Capacitance Tolerance
± 20% (M)
(120Hz, 25°C)
Rated Working Voltage Range
Operation Temperature
160 ~ 400Vdc
450Vdc
-40°C ~ +105°C
-40°C ~ +105°C
(After 2 minutes applying the DC working voltage)
I ≤ 0.06CV + 10 (u A)
Leakage Current (25°C)
◆
I : Leakage Current (u A)
◆
C : Rated Capacitance (u F)
◆
V : Working Voltage (V)
W.V.
160
200
250
350
400
450
S.V.
200
250
300
400
450
500
W.V.
160
200
250
350
400
450
tan δ
0.15
0.15
0.15
0.20
0.24
0.24
W.V.
160
200
250
350
400
450
- 25°C / + 25°C
3
3
3
5
5
6
- 40°C / + 25°C
6
6
6
6
6
-
Surge Voltage (25°C)
Dissipation Factor (120Hz, 25°C)
Temperature Characteristics
◆
Impedance ratio at 120Hz
After 5000 hours application of WV at +105°C, the capacitor shall meet the following limits:
Capacitance Change
Load Test
tan δ
Leakage Current
≤ ± 20% of initial value
≤ 200% of initial specified value
≤ initial specified value
After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:
Capacitance Change
Shelf Test
≤ ± 25% of initial value
tan δ
≤ 200% of initial specified value
Leakage Current
≤ 200% of initial specified value
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
DIMENSIONS
D x L (mm)
WV
160
400
450
3.3
]
10 x 20
4.7
]
13 x 20
uF
200
10
250
350
]
10 x 20
10 x 20
10 x 20
13 x 20
22
10 x 20
10 x 20
13 x 20
13 x 20
13 x 25
16 x 26
33
10 x 20
13 x 20
13 x 20
13 x 25
16 x 26
16 x 31
47
13 x 20
13 x 20
13 x 25
16 x 26
16 x 31
18 x 31
68
13 x 25
13 x 25
16 x 26
16 x 31
18 x 35
18 x 41
100
16 x 26
16 x 26
16 x 31
18 x 31
18 x 41
150
16 x 31
16 x 35
18 x 31
220
16 x 31
18 x 31
18 x 41
330
18 x 31
RC: mA (rms) at 120Hz 105°C
Imp: mΩ (ohm) at 100KHz 25°C
PERMISSIBLE RIPPLE CURRENT
160
WV
uF
Item
RC
200
Imp
RC
250
RC
Imp
RC
400
Imp
RC
450
Imp
RC
Imp
3.3
]
60
6.50
4.7
]
80
3.60
10
Imp
350
]
105
3.50
100
3.00
105
2.90
110
3.00
22
160
1.52
160
1.52
165
2.40
165
2.10
185
1.32
200
1.75
33
190
1.30
210
0.98
210
1.90
230
1.00
230
0.95
275
1.20
47
265
0.93
265
0.93
282
1.70
313
0.74
300
0.75
340
0.96
68
355
0.61
355
0.61
385
0.79
410
0.49
420
0.49
460
0.80
100
475
0.28
475
0.28
520
0.64
530
0.40
545
0.36
150
637
0.22
650
0.22
645
0.44
220
750
0.22
780
0.22
820
0.35
330
960
0.22
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com