MPD B1000R 10w, 5 vdc input compact, dual output dc/dc converter Datasheet

MicroPower
Direct
10W, 5 VDC Input
Compact, Dual Output
DC/DC Converters
B1000R Series
Key Features
5 VDC Input
10W Output Power
Meets EN55022 Class “A”
1500 VDC Isolation
Tightly Regulated Dual Outputs
Low Cost
Electrical Specifications
Specifications typical @ +251C with nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Min.
Typ.
Max.
Units
4.5
5.0
5.5
VDC
π (Pi) Filter (Complies with EN55022 Class A)
Reverse Polarity Input Current
Short Circuit Input Power
2.0
A
3,500
4,500
mW
Typ.
Max.
Units
!0.5
!1.0
%
!0.2
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Dual Output , Balanced Loads
!0.5
%
Vin = Min to Max
!0.1
%
Iout = 10% to 100%
!0.15
%
30
mV P - P
200
µSec
!4.0
%
!0.01
!0.02
%/1C
Typ.
Max.
Units
Ripple & Noise (20 MHz)
20
Output Power Protection
Transient Recovery Time (Note 1)
Transient Response Deviation
150
%
25% Load Step Change
Temperature Coefficient
Output Short Circuit
Continuous
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,500
500 VDC
1,000
100 kHz, 1V
Switching Frequency
VDC
MΩ
500
600
pF
270
280
290
kHz
Environmental
Parameter
Min.
Typ.
Max.
Units
Operating Temperature Range
Conditions
-40
+25
+71
1C
Storage Temperature Range
-40
+125
1C
95
%
Cooling
Humidity
RFI
Free Air Convection
RH, Non-condensing
Six-Sided Shielded, Metal Case
Conducted EMI
EN55022 Class A
Physical
Case Size
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Case Material
Metal with Non-Conductive Base
Weight
1.06 Oz (30g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
Typ.
Max.
700
MIL HDBK 217F, 251C, Gnd Benign
Units
kHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Internal Power Dissipation
Conditions
Min.
-0.7
Typ.
Max.
Units
7.5
VDC
5,000
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
MicroPower Direct TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: [email protected] WEB: www/micropowerdirect.com
Model Selection Guide
Model
Number
Voltage (VDC)
Nominal
Range
5
5
5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
Input
Current (mA)
Output
Fuse Rating
Reflected
Efficiency
Slow-Blow
Current
Ripple Voltage Current
(%, Typ)
(mA)
(VDC) (mA, Max) (mA, Min)
Full-Load No-Load Current
(mA, Typ)
B1001R
B1002R
B1003R
2,500
2,538
2,669
30
30
60
>50
>50
>50
!12.0
!15.0
!18.0
!415
!330
!278
78
78
75
!42
!33
!28
5,000
5,000
5,000
Notes:
1. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from each output (pin 3 &
pin 5) to common (pin 4).
3. Dual output units may be connected to provide a 24 VDC, 30 VDC or 36 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common.
Derating Curve
100
Output Power %
80
60
40
20
0
-40
-20
0
5
15
25
35
45
55
65
75
85
95
105
Ambient Temperature ( C)
Mechanical Dimensions
0.40
(10.2)
0.40
(10.2)
Bottom
5
2
4
Capacitive Load
0.40
(10.2)
µF Max
1.00
(25.4)
1
!1,000
0.40
(10.2)
3
Pin Connections
0.10
(2.54)
0.80
(20.3)
0.60
(15.2)
2.00
(50.8)
0.40
(10.2)
Pin
Function
1
+Vin
2
-Vin
3
+Vout
4
Common
5
-Vout
Side
0.24
(6.0)
Notes:
0.04 Dia
(1.0)
MicroPower
Direct
All dimensions are typical in inches (mm)
Tolerance x.xx = !0.01 (!0.25)
232 Tosca Drive, Stoughton, MA 02072
www.micropowerdirect.com
[email protected]
phone: (781) 344 - 8226 * fax: (781) 344 - 8481
Similar pages