50(W) x 18.5(H) x 75(L) mm
DPS-12FP A
FEATURES
Input
Voltage range
90~264Vac auto range
Frequency
47~63Hz
Efficiency
The average efficiency at 25%, 50%, 75% and 100%
load ≥ 80%
• Total power 12W
• 90-264Vac auto range input
• High reliability: >100,000 hours @ full load
and normal input (25 ℃)
• Protection: Short / Over-current / Over-voltage
Input Current
Output
90~132Vac /12V/1A load ≤ 0.5A
180~264Vac / 12V/1A load ≤ 0.25A
12V
0A to 1A
• Safety: UL/cUL, TUV, CB by Demko ,CCC
Over-current
Auto recovery
Over-temperature
Auto recovery
Short
Auto recovery
Over-voltage
Auto recovery
Operating temp.
0 to 50°C Full load,60°C 80% load,70 °C 60% load,
Storage temp.
-20 to 70°C
Operating humidity
10% - 90%
Storage humidity
10% - 95%
Protection
Environment
/ Over-temperature
• CCC: 5000 meter
• Bulk Cap: JP Type
• EMI: CLASS B
DPS-12FP A
Electrical Safety
UL/cUL, TUV, CB by Demko , CCC,CE, KC,BSMI
refer to EN 60950-1
CE
In conformance with EMC Directive 2004/108/EC and Low Voltage
Directive 2006/95/EC
EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B
Air Discharge: ± 8KV min
Safety
Standards/Directives
ESD(IEC61000-4-2)
Contact Discharge: ±4KV min.
EMC
EFT(IEC61000- 4-4)
+/- 1KV
Common Mode:+/- 2KV
Surge(IEC61000-4-5)
Isolation
Input to Output
3.0KVac
Different Mode:+/- 1KV