Finisar FTLX3871DCCXX 10gb/s dwdm 80km multi-rate sfp transceiver Datasheet

Product Specification
10Gb/s DWDM 80km Multi-Rate SFP+ Transceiver
FTLX3871DCCxx
PRODUCT FEATURES
 Hot-pluggable SFP+ footprint
 Supports 8.5 and 9.95 to 11.3 Gb/s
 Up to 80km link length
 100 GHz channel spacing
 -5 /70°C case temperature range
 Single 3.3V power supply
 Cooled 1550nm EML laser
 Limiting electrical interface receiver
APPLICATIONS
 DWDM 80km point to point links:
 Duplex LC connector

Fibre Channel 8.5G and 10G
 Built-in digital diagnostic functions

10G Ethernet
 RoHS-6 compliant (lead-free)
 ITU-T G.698.1 DS100S1-2Dz(C)
Finisar’s FTLX3871DCCxx transceivers are Enhanced Small Form Factor Pluggable
SFP+ transceivers designed for use in 10-Gigabit multi-rate links up to 80km of G.652
single mode fiber. They are compliant with SFF-84311, SFF-84322 and G.698.1
DS100S1-2Dz(C), and 10G Ethernet ZR and 10G Fibre Channel over 80km fiber.
Digital diagnostics functions are available via a 2-wire serial interface, as specified in
SFF-84723. The optical transceiver is compliant per the RoHS Directive
2011/65/EU4. See Finisar Application Note AN-2038 for more details5.
PRODUCT SELECTION
Product Part Number
FTLX3871DCCxx
 Finisar Corporation – September 2015
Channel Spacing
100 GHz ITU-T grid
Rev. C1
Page 1
FTLX3871DCCxx Product Specification
Product Channel Selection
Channel
(xx)
Product
Code
Frequency
(THz)
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
FTLX3871DCC17
FTLX3871DCC18
FTLX3871DCC19
FTLX3871DCC20
FTLX3871DCC21
FTLX3871DCC22
FTLX3871DCC23
FTLX3871DCC24
FTLX3871DCC25
FTLX3871DCC26
FTLX3871DCC27
FTLX3871DCC28
FTLX3871DCC29
FTLX3871DCC30
FTLX3871DCC31
FTLX3871DCC32
FTLX3871DCC33
FTLX3871DCC34
FTLX3871DCC35
FTLX3871DCC36
FTLX3871DCC37
FTLX3871DCC38
FTLX3871DCC39
FTLX3871DCC40
FTLX3871DCC41
FTLX3871DCC42
FTLX3871DCC43
FTLX3871DCC44
FTLX3871DCC45
FTLX3871DCC46
FTLX3871DCC47
FTLX3871DCC48
FTLX3871DCC49
FTLX3871DCC50
FTLX3871DCC51
FTLX3871DCC52
FTLX3871DCC53
FTLX3871DCC54
FTLX3871DCC55
FTLX3871DCC56
FTLX3871DCC57
FTLX3871DCC58
FTLX3871DCC59
FTLX3871DCC60
FTLX3871DCC61
191.70
191.80
191.90
192.00
192.10
192.20
192.30
192.40
192.50
192.60
192.70
192.80
192.90
193.00
193.10
193.20
193.30
193.40
193.50
193.60
193.70
193.80
193.90
194.00
194.10
194.20
194.30
194.40
194.50
194.60
194.70
194.80
194.90
195.00
195.10
195.20
195.30
195.40
195.50
195.60
195.70
195.80
195.90
196.00
196.10
Center
Wavelength
(nm)
1563.86
1563.05
1562.23
1561.42
1560.61
1559.79
1558.98
1558.17
1557.36
1556.55
1555.75
1554.94
1554.13
1553.33
1552.52
1551.72
1550.92
1550.12
1549.32
1548.51
1547.72
1546.92
1546.12
1545.32
1544.53
1543.73
1542.94
1542.14
1541.35
1540.56
1539.77
1538.98
1538.19
1537.40
1536.61
1535.82
1535.04
1534.25
1533.47
1532.68
1531.90
1531.12
1530.33
1529.55
1528.77
Table 1. Product ordering codes: the central wavelength is defined as per ITU-T 694.1
 Finisar Corporation – September 2015
Rev. C1
Page 2
FTLX3871DCCxx Product Specification
I.
Pin Descriptions
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Symbol
VEET
TFAULT
TDIS
SDA
SCL
MOD_ABS
RS0
RX_LOS
RS1
VEER
VEER
RDRD+
VEER
VCCR
VCCT
VEET
TD+
TDVEET
Name/Description
Transmitter Ground
Transmitter Fault
Transmitter Disable. Laser output disabled on high or open.
2-wire Serial Interface Data Line
2-wire Serial Interface Clock Line
Module Absent. Grounded within the module
Rate Select 0.
Loss of Signal indication. Logic 0 indicates normal operation.
Rate Select 1.
Receiver Ground
Receiver Ground
Receiver Inverted DATA out. AC Coupled.
Receiver Non-inverted DATA out. AC Coupled.
Receiver Ground
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground
Ref.
1
2
3
2
2
2
4
5
4
1
1
1
6
6
1
1
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. TFAULT is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on
3.
4.
5.
6.
the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high
output indicates a transmitter fault caused by either the TX bias current or the TX output power
exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the
output is pulled to <0.8V.
Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
Internally pulled down per SFF-8431 Rev 4.1.
LOS is open collector output. Should be pulled up with 4.7k – 10k on host board to a voltage
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Internally connected
1
Towards
Bezel
2
TX_Fault
3
TX_Disable
4
SDA
5
SCL
6
RS0
8
RX_LOS
10
20
TD-
19
TD+
18
VeeT
17
VccT
16
VccR
15
VeeR
14
MOD_ABS
7
9
VeeT
VeeT
RD+
13
RD-
12
VeeR
11
Towards
ASIC
RS1
VeeR
Figure 1. Diagram of Host Board Connector Block Pin Numbers and Names.
 Finisar Corporation – September 2015
Rev. C1
Page 3
FTLX3871DCCxx Product Specification
II. Absolute Maximum Ratings
Exceeding the limits below may damage the transceiver module permanently.
Parameter
Maximum Supply Voltage
Storage Temperature
Relative Humidity
Receiver Optical Damage Threshold
Symbol
Vcc
TS
RH
RxDamage
Min
-0.5
-40
0
5
Typ
Max
4.0
85
85
Unit
V
C
%
dBm
Ref.
Symbol
Vcc
Min
3.14
Typ.
Max
3.46
Unit
Ref.
Rin
Vin,pp
VD
VEN
80
120
Vcc-0.8
Vee
100
120
850
Vcc
Vee+ 0.8
1
Notes:
1. Non-condensing
III.
Electrical Characteristics (TOP = -5 to 70 C)
Parameter
Supply Voltage
Transmitter
Input differential impedance
Differential data input swing
Transmit Disable Voltage
Transmit Enable Voltage
Receiver
Output differential impedance
Differential data output swing
Output rise time and fall time
LOS asserted
LOS de-asserted
Power Supply Noise Tolerance
Power Consumption
Rout
Vout,pp
Tr, Tf
VLOS A
VLOS D
VccT/VccR
80
100
120
300
850
28
Vcc-0.8
Vcc
Vee
Vee+0.8
Per SFF-8431 Rev 4.1
1.6
1.7


mV
V
V


mV
ps
V
V
mVpp
W
Notes:
1. Internally AC coupled. Data pins connect directly to the CDR.
2.
20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four 0’s
sequence in the PRBS 9 is an acceptable alternative. SFF-8431 Rev 4.1.
3. LOS is an open collector output. Should be pulled up with 4.7k – 10k on the host board. Normal operation is
logic 0; loss of signal is logic 1.
4. See Section 2.8.3 of SFF-8431 Rev 4.1.
5. Typical power consumption at 70C case temperature, beginning of life and 3.3V supply voltage.
 Finisar Corporation – September 2015
Rev. C1
Page 4
1
1
2
3
3
4
5
FTLX3871DCCxx Product Specification
IV. Optical Characteristics (TOP = -5 to 70 C, VCC = 3.14 to 3.46 Volts)
Parameter
Symbol Min Typ
Max
Transmitter (Tx)
Average Launch Power
PAVE
-1
+3
Optical Wavelength
As per ITU-T 694.1
c 
Center Wavelength (End of Life)
c_EOL
c±100pm
Side-Mode Suppression Ratio
SMSR
30
Optical Extinction Ratio
ER
8.2
Average Launch power when Tx is OFF
POFF
-30
Relative Intensity Noise
RIN
-128
Receiver (Rx)
Optical Center Wavelength
1260
1600
C
Reflectance
Rrx
-27
Bit Rate (Gb/s)
BER
Sensitivity
8.5, 9.95-10.7
<10-12 RSENS1
-24
(0km)
-4
11.1-11.3
<10
RSENS2
-27
8.5, 9.95-10.7
<10-12 RSENS3
-21
Sensitivity
11.1
<10-4 RSENS4
-24
(80km)
-4
11.3
<10
RSENS5
-24
Overload (Average Power)
PAVE
-7
LOS De-Assert
LOSD
-28
LOS Assert
LOSA
-37
-30
LOS Hysteresis
LOSH
0.5
Notes:
1. Refer to Tab. 1.
2. Measured with worst ER=8.2dB; 231 – 1 PRBS.
3. Max chromatic dispersion tolerance over 80km of G.652 single mode fiber:
a. 1450ps/nm
b. 1300ps/nm
c. 1100ps/nm
 Finisar Corporation – September 2015
Rev. C1
Unit

dBm
nm
Ref.
1
dB
dB
dBm
dB/Hz

nm
dB
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dB
Page 5
2
2
2,3.a
2,3.b
2,3.c
FTLX3871DCCxx Product Specification
V.
General Specifications
Parameter
Symbol
BR
LMAX
Min
8.5
Typ
Max
11.3168
80
Bit Rate
Max. Supported Link Length
Notes:
1. Tested with a 231 – 1 PRBS pattern at the BER defined in Table IV.
2. Over G.652 single mode fiber.
Units
Gb/s
km
Ref.
1
2
Timing Parameters
Parameter
Time to initialize cooled module
VI.
Symbol
t_start_up_cooled
Min
Max
90
Units
s
Ref.
Environmental Specifications
Finisar FTLX3871DCCxx transceivers have an operating temperature range from -5°C to
+70°C case temperature.
Parameter
Case Operating Temperature
Storage Temperature
Symbol
Top
Tsto
Min
-5
-40
Typ
Max
70
85
Units
°C
°C
Ref.
VII. Regulatory Compliance
Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations.
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of
EN (IEC) 60950. Copies of certificates are available at Finisar Corporation upon request.
 Finisar Corporation – September 2015
Rev. C1
Page 6
FTLX3871DCCxx Product Specification
VIII. Digital Diagnostic Functions
Finisar FTLX3871DCCxx SFP+ transceivers support the 2-wire serial
communication protocol as defined in the SFP MSA1. It is very closely related to the
memory map defined in the GBIC standard, with the same electrical specifications.
The standard SFP serial ID provides access to identification information that
describes the transceiver’s capabilities, standard interfaces, manufacturer, and other
information.
Additionally, Finisar SFP+ transceivers provide a enhanced digital diagnostic
monitoring interface, which allows real-time access to device operating parameters such
as transceiver temperature, laser bias current, transmitted optical power, received optical
power and transceiver supply voltage. It also defines a sophisticated system of alarm and
warning flags, which alerts end-users when particular operating parameters are outside of
a factory set normal range.
The SFP MSA defines a 256-byte memory map that is accessible over a
2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic
monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally
defined serial ID memory map remains unchanged. The interface is identical to, and is
thus fully backward compatible with both the GBIC Specification and the SFP Multi
Source Agreement. The complete interface is described in Finisar Application Note AN2030: “Digital Diagnostics Monitoring Interface for SFP Optical Transceivers” 7.
The operating and diagnostics information is monitored and reported by a Digital
Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed
through a 2-wire serial interface. When the serial protocol is activated, the serial clock
signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the
SFP transceiver into those segments of the E2PROM that are not write-protected. The
negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod
Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with
SCL to mark the start and end of serial protocol activation. The memories are organized
as a series of 8-bit data words that can be addressed individually or sequentially.
For more information, please see the SFP MSA documentation6 and Finisar
Application Note AN-2030.
Please note that evaluation board FDB-1027 is available with Finisar ModDEMO
software that allows simple to use communication over the 2-wire serial interface.
 Finisar Corporation – September 2015
Rev. C1
Page 7
FTLX3871DCCxx Product Specification
IX. Digital Diagnostic Specifications
FTLX3871DCCxx transceivers can be used in host systems that require either
internally or externally calibrated digital diagnostics.
Parameter
Accuracy
Transceiver temperature
Transceiver supply voltage
Transmitter bias current
Transmitter output power
Receiver average optical input
power
Symbol
Units
Min
DDTemp
DDVoltage
DDBias
DDTx-Power
ºC
V
mA
dBm
-10
2.8
0
-1
DDRx-Power
dBm
-28
Max Accuracy Ref.

+75
±5ºC
1
4.0
±3%
127
±10%
2
+5
±2dB
-5
±2dB
Notes:
1. Internally measured
2. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
X.
SFF-8431 Power-up Sequence
The typical power consumption of the FTLX3871DCCxx may exceed the limit of
1.5W specified for the Power Level II transceivers in [1], for which a power-up sequence
is recommended. However, the FTLX3871DCCxx is factory set to power-up directly to
its operating conditions in Power Level Mode II. Upon request, it can be factory set to
follow the power-up sequence specified for transceivers exceeding 1W, as per [1]. In
power level I, the FTLX3871DCCxx does not carry traffic, but the 2-wire serial
communication is active.
Please refer to [1] and Finisar Application Note AN-2076 for additional details.
XI. Receiver Decision Threshold Control
The host can control the Receiver Decision Threshold (RxDT) of Finisar
FTLX3871DCCxx SFP+ transceivers via the 2-wire serial communication, by setting the
byte 131 of Table 02h. The availability of this function is indicated in Bit 3, Byte 64 of
A0h in the serial ID section. Byte 131 is a 2's complement 7 bit value (-128 - +127) The
decision threshold set is given by:
RxDT = default RxDT + [Byte(131)/256]*100%.
On power-up the byte 131 defaults to 0, corresponding to the RxDT optimum value.
The actual RxDT range the formula covers is about ±20% around the default optimum
value.
 Finisar Corporation – September 2015
Rev. C1
Page 8
FTLX3871DCCxx Product Specification
XII.
Mechanical Specifications
Finisar FTLX3871DCCxx SFP+ transceivers are compatible with the SFF-8432
specification for improved pluggable form factor, and shown here for reference purposes
only. Bail color is white.
Figure 2. Mechanical Dimensions
Note: the option of the label on the top side of the transceiver is not recommended.
 Finisar Corporation – September 2015
Rev. C1
Page 9
FTLX3871DCCxx Product Specification
XIII. Host Board SFP+ Connector Recommendations
Figure 3. PCB Layout and Bezel Recommendations, as per [9]
 Finisar Corporation – September 2015
Rev. C1
Page 10
FTLX3871DCCxx Product Specification
Figure 4
 Finisar Corporation – September 2015
Rev. C1
Page 11
FTLX3871DCCxx Product Specification
XIV. Host-Module Interface Diagram
Figure 5
 Finisar Corporation – September 2015
Rev. C1
Page 12
FTLX3871DCCxx Product Specification
XV. References
1. “Specifications for Enhanced 8.5 and 10 Gigabit Small Form Factor Pluggable
Module ‘SFP+ ‘”, SFF Document Number SFF-8431, Revision 4.1.
2. “Improved Pluggable Form factor”, SFF Document Number SFF-8432, Revision 4.2,
April 18, 2007.
3. “Digital Diagnostics Monitoring Interface for Optical Transceivers”. SFF Document
Number SFF-8472, Revision 11.3, June 11, 2013.
4. Directive 2011/65/EU of the European Council Parliament and of the Council, “on
the restriction of the use of certain hazardous substances in electrical and electronic
equipment”
5. “Application Note AN-2038: Finisar Implementation of RoHS Compliant
Transceivers”
6. Small Form-factor Pluggable (SFP) Transceiver Multi-Source Agreement (MSA)
7. “Application Note AN-2030: Digital Diagnostic Monitoring Interface for SFP Optical
Transceivers”
8. “Application Note AN-2076: SFP+ Level II Power Up Sequence”, Rev B
XVI. For More Information
Finisar Corporation
1389 Moffett Park Drive
Sunnyvale, CA 94089-1133
Tel. 1-408-548-1000
Fax 1-408-541-6138
[email protected]
www.finisar.com
 Finisar Corporation – September 2015
Rev. C1
Page 13
Similar pages