Series AM5TW-VZ 5 Watt | DC-DC Converter FEATURES: Wide Input Range (4:1) 24 Pin DIP Package Metal package High efficiency up to 82% Operating temperature -40oC to + 85oC Input / Output isolation 1500 or 3500VDC Pin compatible with multiple manufacturers Continuous short circuit protection Models Single output Input Voltage (V) Output Voltage (V) Output Current max (mA) Capacitive load, max (μF) Efficiency (%) AM5TW-2403S-VZ AM5TW-2405S-VZ AM5TW-2412S-VZ AM5TW-2415S-VZ AM5TW-4803S-VZ AM5TW-4805S-VZ AM5TW-4812S-VZ AM5TW-4815S-VZ 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 2200 1000 470 330 2200 1000 470 330 AM5TW-2403SH35-VZ AM5TW-2405SH35-VZ AM5TW-2412SH35-VZ AM5TW-2415SH35-VZ AM5TW-4803SH35-VZ AM5TW-4805SH35-VZ AM5TW-4812SH35-VZ AM5TW-4815SH35-VZ 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 1200 1000 416 333 1200 1000 416 333 1200 1000 416 333 1200 1000 416 333 2200 1000 470 330 2200 1000 470 330 68 73 74 74 70 73 74 76 68 73 74 74 70 73 74 76 Input Voltage (V) Output Voltage (V) Capacitive load, max (μF) Efficiency (%) 9-36 9-36 9-36 18-72 18-72 18-72 9-36 9-36 9-36 18-72 18-72 18-72 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 Model Models Dual output Model AM5TW-2405D-VZ AM5TW-2412D-VZ AM5TW-2415D-VZ AM5TW-4805D-VZ AM5TW-4812D-VZ AM5TW-4815D-VZ AM5TW-2405DH35-VZ AM5TW-2412DH35-VZ AM5TW-2415DH35-VZ AM5TW-4805DH35-VZ AM5TW-4812DH35-VZ AM5TW-4815DH35-VZ Output Current max (mA) ±500 ±208 ±166 ±500 ±208 ±166 ±500 ±208 ±166 ±500 ±208 ±166 ±470 ±100 ±68 ±470 ±100 ±68 ±470 ±100 ±68 ±470 ±100 ±68 77 82 82 72 75 75 77 82 82 72 75 75 Input Specifications Parameters Voltage Range Nominal Typical 24 48 9-36 18-72 24 Vin 48 Vin 20 15 -0.7-40 -0.7-80 www.aimtec.com F 051e R13.B Units VDC (Pi) Network Filter Start up time Peak Input Voltage time Absolute Max Rating Maximum Tel: +1 514 620 2722 1 of 3 Ms Ms VDC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5TW-VZ 5 Watt | DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Typical 3 sec Resistance Capacitance Rated Units 1500 (3500 H35 model) VDC > 1000 60 MOhm pF Output Specifications Parameters Voltage Balance Voltage accuracy Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Conditions Typical Balanced Load ±1 ±1 Maximum Units % % Continuous Auto Recovery ±0.5 ±0.5 ±0.02 60 At 20MHz Bandwidth % % %/oC mV p-p General Specifications Parameters Conditions Typical Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions(L x W x H) MTBF 100% load Full Load (see derating chart) 100-400 Maximum Units 100 KHz o C o C o C -40 to +85 -40 to +125 Free air convection 95 % Nickel coated copper 15 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm >2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Standards Designed to meet IEC 60950-1 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Pin 1 2 3 9 10 11 12/13 14 15 16 22 23 24 1500VDC Dual Single Dual +V Input N.C. N.C. No pin -V Output +V Output -V Input +V Output -V Output No pin N.C. N.C. +V Input +V Input -V Output Common No pin Common +V Output -V Input +V Output Common No pin Common -V Output +V Input No pin -V Input -V Input No pin No pin N.C. No pin +V Output No pin -V Output +V Input +V Input No pin No pin -V Input -V Input Common No pin -V Output No pin +V Output No pin Common +V Input +V Input No pin www.aimtec.com F 051e R13.B 3500VDC Single Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5TW-VZ 5 Watt | DC-DC Converter Dimensions Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only