Schurter EF11 Iec appliance inlet c20 with circuit breaker ta45 Datasheet

EF11
Power entry modules without line filter
https://www.schurter.com /PG05
IEC Appliance Inlet C20 with Circuit Breaker TA45
C20
Approvals and Compliances
70° C
Description
- Panel Mount :
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions :
Appliance Inlet Protection class I , circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
All single elements are already wired
Unwired versions available on request
Circuit Breaker non-illuminated or illuminated
Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Unwired versions
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter EF12
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temperature
IP-Protection
Insulation cover
Terminal
Panel Thickness S
Material: Housing
16 A / 250 VAC; 50 Hz
20 A / 125/250 VAC; 60 Hz
> 1.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-10 °C to 55 °C
appliance inlet/-outlet
Circuit Breakers
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: EF11
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40001029
UL Approvals
UL
UL File Number: E96454
Connectors
1
EF11
Power entry modules without line filter
https://www.schurter.com /PG05
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
Dimensions [mm]
Screw-on mounting
76.7
36
10.6
32.2
2.3
31.7
41.7
3.6/M3
R6
79.5 ±0.10
12
26.6
ø 6.4
** --- Version TA45 with undervoltage relaese
2
90 ±0.10
78.7
ø 3.3
Connectors
4.8
32.5 ±0.10
5.25 ±0.05
7
4.
55
2.
R
R
10.4
R 2.8
5
79.2
12.2
40.55
90
100
R
2.
95
±0
.0
5
0.8
EF11
Power entry modules without line filter
https://www.schurter.com /PG05
Snap-in mounting
76.7
+0.05
31.7
32.5 - 0.10
+0.05
79.5 - 0.15
79.2
40.55
83
41.7
78.7
10.6
36
2.3
.05
±0
R
4.
S ±0.05
26.6
55
R
32.2
2.
7
R
R 2.8
12
12.2
5
2.9
4.8
**--- Version TA45 with undervoltage release
Diagrams
L
L' P1
1)
2)
PE
N
PE'
N' P2
1) Line
2) Load
Connectors
3
EF11
Power entry modules without line filter
https://www.schurter.com /PG05
Table 1 Selection for type TA45
Order example
3
P1
ABT
W
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other variants on request
5
a
Diagram
Thermal overload protection
1-pole
P2
Without illumination
P2
P1
3
4
3
6
With illumination
220…240 V
110…120 V
2-pole
P1
ABT
ABD
A12
A14
A32
A34
}
Colours
Switch front
W
B
6
Rocker
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
printed
OFF OFF
L
printed
Illustration
black
white
P
printed
I
O
white
black
R
printed
I
M
printed
O
black
white
Position of the rocker legend
e.g F
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
10,0
11,0
12,0
100
110
120
13,0
14,0
15,0
130
140
150
16,0
17,0
18,0
160
170
180
19,0
20,0
190
200
Other rated currents on request
Without release: code C0
Undervoltage release
P2
P1
U<
4
P2
Remote trip release
b
U<
P1
Colour of print
O
K
Surface
l
O
printed
Colour of print
O
l
H
F
l
embossed
ON
Illustration
ON
Surface
P2
ba
P1
P2
c P1
U<
U
E
Z
A
Code
Rated
voltage Un
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
Connectors
F
150
C0
EF11
Power entry modules without line filter
https://www.schurter.com /PG05
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10'000
60
Tripping characteristics
In > 3… < 18 A
Type
TA45
Rated current
In <3 A
[ min ] [ sec ]
10'000
60
1 pole protected
2`000
30
20
2 pole protected
30
+23 °C
10
20
1`000
10
Ambient temp.
500
Tripping characteristics
In > 18 A
[ min ] [ sec ]
10'000
Type
TA4 5
Rated current
In > 3 A... < 18 A
60
1 pole protected
2`000
30
2 pole protected
20
1`000
+23 °C
Ambient temp.
500
10
5
5
200
100
100
1
1 pole protected
2 pole protected
1`000
100
1
50
50
20
10
10
5
5
5
2
2
2
1
1
1
0,5
0,5
0,5
0,1
1,05 1,32
2
3
4
5
8
10
[ x In ]
Multiple of rated current
0,3
0,2
0,1
1,05 1,32
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below:
Correction factor
0,89
0,91
0,92
1,00
1,03
1,08
1,16
2
3
4
5
8
10
0,3
0,2
0,1
1,05 1,32
[ x In ]
Multiple of rated current
1) Effect of ambient temperature
* Ambient temperature [°C]
–10
– 5
0
+23
+30
+40
+55
+23 °C
200
10
0,2
Ambient temp.
500
20
0,3
In > 18 A
2`000
20
Tripping time
Tripping time
50
TA4 5
Rated current
5
200
Tripping time
1
Type
2
3
4
5
Multiple of rated current
8
10
[ x In ]
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
1) Example
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+40 °C ambient temperature
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Configurtation code (example)
Type
Order code TA45
(2-pole rocker-switch
without accessories)
EF11 - ABTWF150C0 - 000 - 111 - 000
see table 1
Optional Variants
0 standard
9 V-Lock notch
Colour
0 black
Mounting
0 Screw mounting
2 Snap-in mounting s = 1.5
3 Snap-in mounting s = 2.0
4 Snap-in mounting s = 2.5
Terminal PE
1 Quick-connect terminals 6.3x0.8mm
Terminal N
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
Terminal L
1 Quick-connect terminals 6.3x0.8mm, without connection to TA45
3 connection to TA45 non insulated
Connectors
5
EF11
Packaging unit
Power entry modules without line filter
https://www.schurter.com /PG05
16 Pcs
Accessories
Description
Assorted Covers
Rear Cover
0859.0109
Cord retaining kits
Cord retaining strain relief
Flat head, H
4700.0008
Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight
4795
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
0104U
Connector further types to EF11
Power Supply Cord Overview complete
Cord Sets 10 A, North America, 3.0 m, Connector IEC C13, SJT 3x18 AWG, Transparent
4300.0920
Cord Sets 16 A, Europlug, 2.5 m, Connector IEC C19, H05VV-F3G1.5, black
6004.0395
Cord Sets 16 A, Interconnection, 1.0 m, Connector IEC C19, H05VV-F3G1.5, black
6020.0392
Cord Sets 16 A, Interconnection, 2.0 m, Connector IEC C19, H05VV-F3G1.5, black
6020.0394
Cord Sets 16 A, North America, 2.5 m, Connector IEC C19, SJT 3x14 AWG, black
6009.5195
Power Supply Cord further types to EF11
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight
VAC19KS
01.12.2017
Power Cord further types to EF11
6
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Similar pages