EF11 Power entry modules without line filter https://www.schurter.com /PG05 IEC Appliance Inlet C20 with Circuit Breaker TA45 C20 Approvals and Compliances 70° C Description - Panel Mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet Protection class I , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired Unwired versions available on request Circuit Breaker non-illuminated or illuminated Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Unwired versions - Variant with notch for V-Lock mating Cordsets References Alternative: version with line filter EF12 Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temperature IP-Protection Insulation cover Terminal Panel Thickness S Material: Housing 16 A / 250 VAC; 50 Hz 20 A / 125/250 VAC; 60 Hz > 1.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -10 °C to 55 °C appliance inlet/-outlet Circuit Breakers from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 C20 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: EF11 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001029 UL Approvals UL UL File Number: E96454 Connectors 1 EF11 Power entry modules without line filter https://www.schurter.com /PG05 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Dimensions [mm] Screw-on mounting 76.7 36 10.6 32.2 2.3 31.7 41.7 3.6/M3 R6 79.5 ±0.10 12 26.6 ø 6.4 ** --- Version TA45 with undervoltage relaese 2 90 ±0.10 78.7 ø 3.3 Connectors 4.8 32.5 ±0.10 5.25 ±0.05 7 4. 55 2. R R 10.4 R 2.8 5 79.2 12.2 40.55 90 100 R 2. 95 ±0 .0 5 0.8 EF11 Power entry modules without line filter https://www.schurter.com /PG05 Snap-in mounting 76.7 +0.05 31.7 32.5 - 0.10 +0.05 79.5 - 0.15 79.2 40.55 83 41.7 78.7 10.6 36 2.3 .05 ±0 R 4. S ±0.05 26.6 55 R 32.2 2. 7 R R 2.8 12 12.2 5 2.9 4.8 **--- Version TA45 with undervoltage release Diagrams L L' P1 1) 2) PE N PE' N' P2 1) Line 2) Load Connectors 3 EF11 Power entry modules without line filter https://www.schurter.com /PG05 Table 1 Selection for type TA45 Order example 3 P1 ABT W • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other variants on request 5 a Diagram Thermal overload protection 1-pole P2 Without illumination P2 P1 3 4 3 6 With illumination 220…240 V 110…120 V 2-pole P1 ABT ABD A12 A14 A32 A34 } Colours Switch front W B 6 Rocker black black black white black – – – orange transp. Rocker legend printed OFF OFF L printed Illustration black white P printed I O white black R printed I M printed O black white Position of the rocker legend e.g F Rated current circuit breaker of equipment In Code In Code In Code In Code 10,0 11,0 12,0 100 110 120 13,0 14,0 15,0 130 140 150 16,0 17,0 18,0 160 170 180 19,0 20,0 190 200 Other rated currents on request Without release: code C0 Undervoltage release P2 P1 U< 4 P2 Remote trip release b U< P1 Colour of print O K Surface l O printed Colour of print O l H F l embossed ON Illustration ON Surface P2 ba P1 P2 c P1 U< U E Z A Code Rated voltage Un • • • • 2 240 V AC • • • • 3 230 V AC • • • • 4 120 V AC Connectors F 150 C0 EF11 Power entry modules without line filter https://www.schurter.com /PG05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 60 Tripping characteristics In > 3… < 18 A Type TA45 Rated current In <3 A [ min ] [ sec ] 10'000 60 1 pole protected 2`000 30 20 2 pole protected 30 +23 °C 10 20 1`000 10 Ambient temp. 500 Tripping characteristics In > 18 A [ min ] [ sec ] 10'000 Type TA4 5 Rated current In > 3 A... < 18 A 60 1 pole protected 2`000 30 2 pole protected 20 1`000 +23 °C Ambient temp. 500 10 5 5 200 100 100 1 1 pole protected 2 pole protected 1`000 100 1 50 50 20 10 10 5 5 5 2 2 2 1 1 1 0,5 0,5 0,5 0,1 1,05 1,32 2 3 4 5 8 10 [ x In ] Multiple of rated current 0,3 0,2 0,1 1,05 1,32 The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below: Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16 2 3 4 5 8 10 0,3 0,2 0,1 1,05 1,32 [ x In ] Multiple of rated current 1) Effect of ambient temperature * Ambient temperature [°C] –10 – 5 0 +23 +30 +40 +55 +23 °C 200 10 0,2 Ambient temp. 500 20 0,3 In > 18 A 2`000 20 Tripping time Tripping time 50 TA4 5 Rated current 5 200 Tripping time 1 Type 2 3 4 5 Multiple of rated current 8 10 [ x In ] * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. 1) Example Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at +40 °C ambient temperature 6,0 A +40 °C 1,08 6 A x 1,08 = 6,5 A Configurtation code (example) Type Order code TA45 (2-pole rocker-switch without accessories) EF11 - ABTWF150C0 - 000 - 111 - 000 see table 1 Optional Variants 0 standard 9 V-Lock notch Colour 0 black Mounting 0 Screw mounting 2 Snap-in mounting s = 1.5 3 Snap-in mounting s = 2.0 4 Snap-in mounting s = 2.5 Terminal PE 1 Quick-connect terminals 6.3x0.8mm Terminal N 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 3 connection to TA45 non insulated Terminal L 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 3 connection to TA45 non insulated Connectors 5 EF11 Packaging unit Power entry modules without line filter https://www.schurter.com /PG05 16 Pcs Accessories Description Assorted Covers Rear Cover 0859.0109 Cord retaining kits Cord retaining strain relief Flat head, H 4700.0008 Mating Outlets/Connectors Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 0104U Connector further types to EF11 Power Supply Cord Overview complete Cord Sets 10 A, North America, 3.0 m, Connector IEC C13, SJT 3x18 AWG, Transparent 4300.0920 Cord Sets 16 A, Europlug, 2.5 m, Connector IEC C19, H05VV-F3G1.5, black 6004.0395 Cord Sets 16 A, Interconnection, 1.0 m, Connector IEC C19, H05VV-F3G1.5, black 6020.0392 Cord Sets 16 A, Interconnection, 2.0 m, Connector IEC C19, H05VV-F3G1.5, black 6020.0394 Cord Sets 16 A, North America, 2.5 m, Connector IEC C19, SJT 3x14 AWG, black 6009.5195 Power Supply Cord further types to EF11 Mating Outlets/Connectors shuttered Power Cord Overview complete Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS 01.12.2017 Power Cord further types to EF11 6 Connectors The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.