Click on Series name for product info on aimtec.com Series AME3-AZ 3Watt | AC-DC Converter FEATURES: • • • • • Models Single output I/O Isolation 3000VAC Operating Temp: -40oCto +80oC Over load, Short Circuit Protection Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC • RoHS compliant • Energy Star compliant • Ultra small package Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) AME3-3.3SAZ AME3-5SAZ AME3-12SAZ AME3-15SAZ AME3-24SAZ 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 130-430 130-430 130-430 130-430 130-430 -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 3.3 5 12 15 24 900 600 250 200 125 AME3-3.3SBAZ AME3-5SBAZ AME3-12SBAZ AME3-15SBAZ AME3-24SBAZ 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 130-745 130-745 130-745 130-745 130-745 -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 3.3 5 12 15 24 700 600 250 200 125 Model Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Transient Recovery Time Transient Response Deviation Minimum load Conditions Typical Recommended slow blow type 1 ≦0.5 115 VAC 230 VAC 277 VAC 480VAC 115 VAC 230 VAC 277 VAC 480 VAC Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over Load protection Short circuit protection www.aimtec.com F 052e R8.B Efficiency (%) 115 230 277 2200 1100 680 560 470 63 67 75 78 81 64 67 73 74 81 62 65 70 71 80 2200 1100 680 560 470 61 67 72 72 71 61 67 72 71 71 60 66 70 70 69 VAC Maximum 80 40 35 30 10 15 20 30 0.15 VAC VAC 480 VAC 54 60 61 61 62 Units mA mA mA mA A A A A mA A W Conditions Typical Maximum Conditions Typical Rated Units Maximum Units ±5 ±1.5 ±5 200 25% load step ±2 0 3.3/5 VAC With 560µF E/C 200 Ripple & Noise 12/15 VAC With 220µF E/C 400 24 VAC With 220µF E/C 500 *Ripple & Noisemeasured at 20MHz bandwidth with 0.1µFand 115/230/277/480VAC( Typical input ) with Full Load Isolation Specifications Parameters Maximum capacitive Load (µF) Full load (typical)* LL-HL, Full Load 0-100% load (typical)* 60 sec >1000 Conditions Typical 100 >125% Auto recovery Auto recovery Tel: +1 514 620 2722 1 of 3 3000 Units % % % µs % of Vout % mV p-p mV p-p mV p-p VAC MΩ KHz Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter General Specifications (continued) Parameters Conditions Operating temperature Storage temperature Maximum Case temperature Humidity Case material Weight Dimensions (L x W x H) Typical -40 to +80 -40 to +85 See deratingchart Maximum Units o C C o C % RH o 100 Non condensing 20~95 Plastic resin + Fiberglass (flammability to UL 94V-0) 25 g 1.327 x 0.874 x 0.71 (33.70 x 22.20 x 18.00mm) o > 400 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Vibrations Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Derating cULus, CE, CB (pending), CSA Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity (1KV) RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Canadian Safety Agency IEC/EN/UL 60950-1:2006+A11:2009 EN55022, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 CAN/CSA-C22.2 NO. 60950-1-07 Free Air Convection Output Power % 100 55 ºC 80 Safe Operating Area 60 50 40 25 20 0 -40 -25 0 20 40 55 60 70 80 100 Ambient Temperature º C www.aimtec.com F 052e R8.B Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 AC Input (N) AC Input (L) -V Output +V Output Dimensions NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only