Panasonic HC2E-HP-AC48V-F Relay for control panel of 1a to 10a (1c/2c/3c/4c) Datasheet

HC
VDE
1c, 2c, 4c
Relay for control panel of
1A to 10A (1c/2c/3c/4c)
Standard type
Amber sealed type
HC RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Standard type and Amber sealed
type
2. Rich lineup includes relays with
operating indication, with diode
3. Full range of types
Plug-in type, PC board type and TM
type
4. Sockets and terminal sockets are
available.
1. Factory automation equipment and
automotive devices
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
With diode type
RoHS compliant
ORDERING INFORMATION
Standard type
Amber sealed type
HC
HC
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
Contact arrangement
1: 1 Form C
2: 2 Form C
4: 4 Form C
Nil: Standard type
E: Amber sealed type
ED: Amber sealed type bifurcated contact
(twin) (Only 4 Form C)
Terminal arrangement
H:
Plug-in type
HL: Plug-in with LED indication
HP: PC board type
HPL: PC board with LED indication
HTM: TM type
Terminal arrangement
H:
Plug-in type
L:
Plug-in with LED indication
HP: PC board type
PL: PC board with LED indication
HTM: TM type
Nominal coil voltage
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC 6, 12, 24, 48, 100 (100/110) V
Nominal coil voltage
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC 6, 12, 24, 48, 100 (100/110) V
Contact material
Contact
material
Contact
arrangement
1 Form C
2 Form C
3 Form C
4 Form C
4-pole bifurcated (twin)
AgSnO2 type
AgNi type
F
F
F
Panasonic Corporation
Nil
Nil
Automation Controls Business Unit
Contact material
Contact
material
Contact
arrangement
1 Form C
2 Form C
4 Form C
4-pole bifurcated (twin)
AgSnO2 type
AgNi type
F
F
industrial.panasonic.com/ac/e/
Nil
Nil
ASCTB4E 201302-T
HC
With diode type (For DC)
HC
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
Terminal arrangement
Nil: Plug-in type
L: Plug-in with LED indication
Nominal coil voltage
DC: 6, 12, 24, 48, 100 (100/110) V
Surge suppression
D: With diode
Contact material
Contact
material
Contact
arrangement
1 Form C
2 Form C
3 Form C
4 Form C
4-pole bifurcated (twin)
AgSnO2 type
AgNi type
F
F
F
Nil
Nil
LINEUP
Type
Contact arrangement
Remarks
Plug-in terminal type
Without LED
With LED
HC relay
Standard type
Single side stable
Bifurcated (Twin)
HC relay
Amber sealed
type
Single side stable
Bifurcated (Twin)
DC type with
surge absorbing
diode
Single side stable
Bifurcated (Twin)
PC board terminal type
Without LED
With LED
Top mounting type
(TM type)
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
1 Form C
2 Form C
4 Form C
4 Form C
1 Form C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
—
A
A
A
A
A
A
A
A
A
—
A
A
A
A
A
A
A
A
A
—
2 Form C
3 Form C
4 Form C
4 Form C
A
A
A
A
A
A
A
A
—
—
—
—
—
—
—
—
—
—
—
—
Amber sealed type
also available
A: Available
Notes: 1. HC relays with ground terminals also available.
2. HC relays with 0.9 mm wide PC board terminals also available.
HC RELAY CONTACT ARRANGEMENT
Type
Part number
Features
ASCTB4E 201302-T
Single side stable contact
HC
Suitable for high-capacity load switching
Standard type HC relays have high single-contact capacity;
1 Form C: 10 A
2 Form C and 3 Form C: 7 A
4 Form C: 5 A
Panasonic Corporation
4-pole bifurcated (twin) contact
HC4D
Bifurcated (twin) contact ensures high contact reliability
Suitable for low level loads
Minimum switching capability: 100 µA 100m V DC (reference value)
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
LED INDICATION TYPE
Type
Part number
Features
With LED indication type
HC-HL
LED lights up when relay is operating
Inspection and detection of trouble is easy.
LEDs are green for DC types and red for
AC types.
All types are available with LED indication.
1
2
3
4
5
6
7
8
9
10
11
12
13 –
+14
LED
• LED colors indicate the type of relay:
red for AC type and green for DC type.
Protection diode
(Bottom view)
HC RELAY SERIES PRODUCT TYPES
Type
Part number
Features
Amber sealed type HC relay
HCE
HC relay with diode type (for DC)
HC--V-D
Has built-in diode to absorb surge when the coil goes to the off state (for
Relay is completely sealed with resin.
DC type).
Provides high reliability in adverse surroundings.
Suitable for protecting relay driver circuits and for noise suppression
Suitable for use in dusty conditions or where organic gases are present Diode characteristics: Reverse breakdown voltage 1,000 V
Forward current 1 A
4-pole bifurcated (twin) type and Relay with LED indication are available.
TYPES
1. Standard type
1) Plug-in type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-H-AC6V-F
HC1-H-AC12V-F
HC1-H-AC24V-F
HC1-H-AC48V-F
HC1-H-AC100V-F
HC1-H-AC120V-F
HC1-H-AC200V-F
HC1-H-AC240V-F
HC1-H-DC6V-F
HC1-H-DC12V-F
HC1-H-DC24V-F
HC1-H-DC48V-F
HC1-H-DC100V-F
2 Form C
Part No.
HC2-H-AC6V-F
HC2-H-AC12V-F
HC2-H-AC24V-F
HC2-H-AC48V-F
HC2-H-AC100V-F
HC2-H-AC120V-F
HC2-H-AC200V-F
HC2-H-AC240V-F
HC2-H-DC6V-F
HC2-H-DC12V-F
HC2-H-DC24V-F
HC2-H-DC48V-F
HC2-H-DC100V-F
3 Form C
Part No.
HC3-H-AC6V-F
HC3-H-AC12V-F
HC3-H-AC24V-F
HC3-H-AC48V-F
HC3-H-AC100V-F
HC3-H-AC120V-F
HC3-H-AC200V-F
HC3-H-AC240V-F
HC3-H-DC6V-F
HC3-H-DC12V-F
HC3-H-DC24V-F
HC3-H-DC48V-F
HC3-H-DC100V-F
4 Form C
Part No.
HC4-H-AC6V
HC4-H-AC12V
HC4-H-AC24V
HC4-H-AC48V
HC4-H-AC100V
HC4-H-AC120V
HC4-H-AC200V
HC4-H-AC240V
HC4-H-DC6V
HC4-H-DC12V
HC4-H-DC24V
HC4-H-DC48V
HC4-H-DC100V
4 Form C (twin)
Part No.
HC4D-H-AC6V
HC4D-H-AC12V
HC4D-H-AC24V
HC4D-H-AC48V
HC4D-H-AC100V
HC4D-H-AC120V
HC4D-H-AC200V
HC4D-H-AC240V
HC4D-H-DC6V
HC4D-H-DC12V
HC4D-H-DC24V
HC4D-H-DC48V
HC4D-H-DC100V
2 Form C
Part No.
HC2-HL-AC6V-F
HC2-HL-AC12V-F
HC2-HL-AC24V-F
HC2-HL-AC100V-F
HC2-HL-AC120V-F
HC2-HL-AC200V-F
HC2-HL-AC240V-F
HC2-HL-DC6V-F
HC2-HL-DC12V-F
HC2-HL-DC24V-F
HC2-HL-DC48V-F
HC2-HL-DC100V-F
3 Form C
Part No.
HC3-HL-AC6V-F
HC3-HL-AC12V-F
HC3-HL-AC24V-F
HC3-HL-AC100V-F
HC3-HL-AC120V-F
HC3-HL-AC200V-F
HC3-HL-AC240V-F
HC3-HL-DC6V-F
HC3-HL-DC12V-F
HC3-HL-DC24V-F
HC3-HL-DC48V-F
HC3-HL-DC100V-F
4 Form C
Part No.
HC4-HL-AC6V
HC4-HL-AC12V
HC4-HL-AC24V
HC4-HL-AC100V
HC4-HL-AC120V
HC4-HL-AC200V
HC4-HL-AC240V
HC4-HL-DC6V
HC4-HL-DC12V
HC4-HL-DC24V
HC4-HL-DC48V
HC4-HL-DC100V
4 Form C (twin)
Part No.
HC4D-HL-AC6V
HC4D-HL-AC12V
HC4D-HL-AC24V
HC4D-HL-AC100V
HC4D-HL-AC120V
HC4D-HL-AC200V
HC4D-HL-AC240V
HC4D-HL-DC6V
HC4D-HL-DC12V
HC4D-HL-DC24V
HC4D-HL-DC48V
HC4D-HL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HL-AC6V-F
HC1-HL-AC12V-F
HC1-HL-AC24V-F
HC1-HL-AC100V-F
HC1-HL-AC120V-F
HC1-HL-AC200V-F
HC1-HL-AC240V-F
HC1-HL-DC6V-F
HC1-HL-DC12V-F
HC1-HL-DC24V-F
HC1-HL-DC48V-F
HC1-HL-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
3) PC board type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HP-AC6V-F
HC1-HP-AC12V-F
HC1-HP-AC24V-F
HC1-HP-AC48V-F
HC1-HP-AC100V-F
HC1-HP-AC120V-F
HC1-HP-AC200V-F
HC1-HP-AC240V-F
HC1-HP-DC6V-F
HC1-HP-DC12V-F
HC1-HP-DC24V-F
HC1-HP-DC48V-F
HC1-HP-DC100V-F
2 Form C
Part No.
HC2-HP-AC6V-F
HC2-HP-AC12V-F
HC2-HP-AC24V-F
HC2-HP-AC48V-F
HC2-HP-AC100V-F
HC2-HP-AC120V-F
HC2-HP-AC200V-F
HC2-HP-AC240V-F
HC2-HP-DC6V-F
HC2-HP-DC12V-F
HC2-HP-DC24V-F
HC2-HP-DC48V-F
HC2-HP-DC100V-F
3 Form C
Part No.
HC3-HP-AC6V-F
HC3-HP-AC12V-F
HC3-HP-AC24V-F
HC3-HP-AC48V-F
HC3-HP-AC100V-F
HC3-HP-AC120V-F
HC3-HP-AC200V-F
HC3-HP-AC240V-F
HC3-HP-DC6V-F
HC3-HP-DC12V-F
HC3-HP-DC24V-F
HC3-HP-DC48V-F
HC3-HP-DC100V-F
4 Form C
Part No.
HC4-HP-AC6V
HC4-HP-AC12V
HC4-HP-AC24V
HC4-HP-AC48V
HC4-HP-AC100V
HC4-HP-AC120V
HC4-HP-AC200V
HC4-HP-AC240V
HC4-HP-DC6V
HC4-HP-DC12V
HC4-HP-DC24V
HC4-HP-DC48V
HC4-HP-DC100V
4 Form C (twin)
Part No.
HC4D-HP-AC6V
HC4D-HP-AC12V
HC4D-HP-AC24V
HC4D-HP-AC48V
HC4D-HP-AC100V
HC4D-HP-AC120V
HC4D-HP-AC200V
HC4D-HP-AC240V
HC4D-HP-DC6V
HC4D-HP-DC12V
HC4D-HP-DC24V
HC4D-HP-DC48V
HC4D-HP-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HP-AC6V-31-F.
4) PC board type (with LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HPL-AC6V-F
HC1-HPL-AC12V-F
HC1-HPL-AC24V-F
HC1-HPL-AC100V-F
HC1-HPL-AC120V-F
HC1-HPL-AC200V-F
HC1-HPL-DC6V-F
HC1-HPL-DC12V-F
HC1-HPL-DC24V-F
HC1-HPL-DC48V-F
HC1-HPL-DC100V-F
2 Form C
Part No.
HC2-HPL-AC6V-F
HC2-HPL-AC12V-F
HC2-HPL-AC24V-F
HC2-HPL-AC100V-F
HC2-HPL-AC120V-F
HC2-HPL-AC200V-F
HC2-HPL-DC6V-F
HC2-HPL-DC12V-F
HC2-HPL-DC24V-F
HC2-HPL-DC48V-F
HC2-HPL-DC100V-F
3 Form C
Part No.
HC3-HPL-AC6V-F
HC3-HPL-AC12V-F
HC3-HPL-AC24V-F
HC3-HPL-AC100V-F
HC3-HPL-AC120V-F
HC3-HPL-AC200V-F
HC3-HPL-DC6V-F
HC3-HPL-DC12V-F
HC3-HPL-DC24V-F
HC3-HPL-DC48V-F
HC3-HPL-DC100V-F
4 Form C
Part No.
HC4-HPL-AC6V
HC4-HPL-AC12V
HC4-HPL-AC24V
HC4-HPL-AC100V
HC4-HPL-AC120V
HC4-HPL-AC200V
HC4-HPL-DC6V
HC4-HPL-DC12V
HC4-HPL-DC24V
HC4-HPL-DC48V
HC4-HPL-DC100V
4 Form C (twin)
Part No.
HC4D-HPL-AC6V
HC4D-HPL-AC12V
HC4D-HPL-AC24V
HC4D-HPL-AC100V
HC4D-HPL-AC120V
HC4D-HPL-AC200V
HC4D-HPL-DC6V
HC4D-HPL-DC12V
HC4D-HPL-DC24V
HC4D-HPL-DC48V
HC4D-HPL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F.
5) TM type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-HTM-AC6V-F
HC1-HTM-AC12V-F
HC1-HTM-AC24V-F
HC1-HTM-AC48V-F
HC1-HTM-AC100V-F
HC1-HTM-AC120V-F
HC1-HTM-AC200V-F
HC1-HTM-DC6V-F
HC1-HTM-DC12V-F
HC1-HTM-DC24V-F
HC1-HTM-DC48V-F
HC1-HTM-DC100V-F
2 Form C
Part No.
HC2-HTM-AC6V-F
HC2-HTM-AC12V-F
HC2-HTM-AC24V-F
HC2-HTM-AC48V-F
HC2-HTM-AC100V-F
HC2-HTM-AC120V-F
HC2-HTM-AC200V-F
HC2-HTM-DC6V-F
HC2-HTM-DC12V-F
HC2-HTM-DC24V-F
HC2-HTM-DC48V-F
HC2-HTM-DC100V-F
3 Form C
Part No.
HC3-HTM-AC6V-F
HC3-HTM-AC12V-F
HC3-HTM-AC24V-F
HC3-HTM-AC48V-F
HC3-HTM-AC100V-F
HC3-HTM-AC120V-F
HC3-HTM-AC200V-F
HC3-HTM-DC6V-F
HC3-HTM-DC12V-F
HC3-HTM-DC24V-F
HC3-HTM-DC48V-F
HC3-HTM-DC100V-F
4 Form C
Part No.
HC4-HTM-AC6V
HC4-HTM-AC12V
HC4-HTM-AC24V
HC4-HTM-AC48V
HC4-HTM-AC100V
HC4-HTM-AC120V
HC4-HTM-AC200V
HC4-HTM-DC6V
HC4-HTM-DC12V
HC4-HTM-DC24V
HC4-HTM-DC48V
HC4-HTM-DC100V
4 Form C (twin)
Part No.
HC4D-HTM-AC6V
HC4D-HTM-AC12V
HC4D-HTM-AC24V
HC4D-HTM-AC48V
HC4D-HTM-AC100V
HC4D-HTM-AC120V
HC4D-HTM-AC200V
HC4D-HTM-DC6V
HC4D-HTM-DC12V
HC4D-HTM-DC24V
HC4D-HTM-DC48V
HC4D-HTM-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB4E 201302-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
2. Amber sealed type
1) Plug-in type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-H-AC6V-F
HC1E-H-AC12V-F
HC1E-H-AC24V-F
HC1E-H-AC48V-F
HC1E-H-AC100V-F
HC1E-H-AC120V-F
HC1E-H-AC200V-F
HC1E-H-AC240V-F
HC1E-H-DC6V-F
HC1E-H-DC12V-F
HC1E-H-DC24V-F
HC1E-H-DC48V-F
HC1E-H-DC100V-F
2 Form C
Part No.
HC2E-H-AC6V-F
HC2E-H-AC12V-F
HC2E-H-AC24V-F
HC2E-H-AC48V-F
HC2E-H-AC100V-F
HC2E-H-AC120V-F
HC2E-H-AC200V-F
HC2E-H-AC240V-F
HC2E-H-DC6V-F
HC2E-H-DC12V-F
HC2E-H-DC24V-F
HC2E-H-DC48V-F
HC2E-H-DC100V-F
4 Form C
Part No.
HC4E-H-AC6V
HC4E-H-AC12V
HC4E-H-AC24V
HC4E-H-AC48V
HC4E-H-AC100V
HC4E-H-AC120V
HC4E-H-AC200V
HC4E-H-AC240V
HC4E-H-DC6V
HC4E-H-DC12V
HC4E-H-DC24V
HC4E-H-DC48V
HC4E-H-DC100V
4 Form C (twin)
Part No.
HC4ED-H-AC6V
HC4ED-H-AC12V
HC4ED-H-AC24V
HC4ED-H-AC48V
HC4ED-H-AC100V
HC4ED-H-AC120V
HC4ED-H-AC200V
HC4ED-H-AC240V
HC4ED-H-DC6V
HC4ED-H-DC12V
HC4ED-H-DC24V
HC4ED-H-DC48V
HC4ED-H-DC100V
2 Form C
Part No.
HC2E-L-AC6V-F
HC2E-L-AC12V-F
HC2E-L-AC24V-F
HC2E-L-AC48V-F
HC2E-L-AC100V-F
HC2E-L-AC120V-F
HC2E-L-AC200V-F
HC2E-L-AC240V-F
HC2E-L-DC6V-F
HC2E-L-DC12V-F
HC2E-L-DC24V-F
HC2E-L-DC48V-F
HC2E-L-DC100V-F
4 Form C
Part No.
HC4E-L-AC6V
HC4E-L-AC12V
HC4E-L-AC24V
HC4E-L-AC48V
HC4E-L-AC100V
HC4E-L-AC120V
HC4E-L-AC200V
HC4E-L-AC240V
HC4E-L-DC6V
HC4E-L-DC12V
HC4E-L-DC24V
HC4E-L-DC48V
HC4E-L-DC100V
4 Form C (twin)
Part No.
HC4ED-L-AC6V
HC4ED-L-AC12V
HC4ED-L-AC24V
HC4ED-L-AC48V
HC4ED-L-AC100V
HC4ED-L-AC120V
HC4ED-L-AC200V
HC4ED-L-AC240V
HC4ED-L-DC6V
HC4ED-L-DC12V
HC4ED-L-DC24V
HC4ED-L-DC48V
HC4ED-L-DC100V
2 Form C
Part No.
HC2E-HP-AC6V-F
HC2E-HP-AC12V-F
HC2E-HP-AC24V-F
HC2E-HP-AC48V-F
HC2E-HP-AC100V-F
HC2E-HP-AC120V-F
HC2E-HP-AC200V-F
HC2E-HP-AC240V-F
HC2E-HP-DC6V-F
HC2E-HP-DC12V-F
HC2E-HP-DC24V-F
HC2E-HP-DC48V-F
HC2E-HP-DC100V-F
4 Form C
Part No.
HC4E-HP-AC6V
HC4E-HP-AC12V
HC4E-HP-AC24V
HC4E-HP-AC48V
HC4E-HP-AC100V
HC4E-HP-AC120V
HC4E-HP-AC200V
HC4E-HP-AC240V
HC4E-HP-DC6V
HC4E-HP-DC12V
HC4E-HP-DC24V
HC4E-HP-DC48V
HC4E-HP-DC100V
4 Form C (twin)
Part No.
HC4ED-HP-AC6V
HC4ED-HP-AC12V
HC4ED-HP-AC24V
HC4ED-HP-AC48V
HC4ED-HP-AC100V
HC4ED-HP-AC120V
HC4ED-HP-AC200V
HC4ED-HP-AC240V
HC4ED-HP-DC6V
HC4ED-HP-DC12V
HC4ED-HP-DC24V
HC4ED-HP-DC48V
HC4ED-HP-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (With LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-L-AC6V-F
HC1E-L-AC12V-F
HC1E-L-AC24V-F
HC1E-L-AC48V-F
HC1E-L-AC100V-F
HC1E-L-AC120V-F
HC1E-L-AC200V-F
HC1E-L-AC240V-F
HC1E-L-DC6V-F
HC1E-L-DC12V-F
HC1E-L-DC24V-F
HC1E-L-DC48V-F
HC1E-L-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3) PC board type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-HP-AC6V-F
HC1E-HP-AC12V-F
HC1E-HP-AC24V-F
HC1E-HP-AC48V-F
HC1E-HP-AC100V-F
HC1E-HP-AC120V-F
HC1E-HP-AC200V-F
HC1E-HP-AC240V-F
HC1E-HP-DC6V-F
HC1E-HP-DC12V-F
HC1E-HP-DC24V-F
HC1E-HP-DC48V-F
HC1E-HP-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
4) PC board type (With LED indication)
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-PL-AC6V-F
HC1E-PL-AC12V-F
HC1E-PL-AC24V-F
HC1E-PL-AC48V-F
HC1E-PL-AC100V-F
HC1E-PL-AC120V-F
HC1E-PL-AC200V-F
HC1E-PL-AC240V-F
HC1E-PL-DC6V-F
HC1E-PL-DC12V-F
HC1E-PL-DC24V-F
HC1E-PL-DC48V-F
HC1E-PL-DC100V-F
2 Form C
Part No.
HC2E-PL-AC6V-F
HC2E-PL-AC12V-F
HC2E-PL-AC24V-F
HC2E-PL-AC48V-F
HC2E-PL-AC100V-F
HC2E-PL-AC120V-F
HC2E-PL-AC200V-F
HC2E-PL-AC240V-F
HC2E-PL-DC6V-F
HC2E-PL-DC12V-F
HC2E-PL-DC24V-F
HC2E-PL-DC48V-F
HC2E-PL-DC100V-F
4 Form C
Part No.
HC4E-PL-AC6V
HC4E-PL-AC12V
HC4E-PL-AC24V
HC4E-PL-AC48V
HC4E-PL-AC100V
HC4E-PL-AC120V
HC4E-PL-AC200V
HC4E-PL-AC240V
HC4E-PL-DC6V
HC4E-PL-DC12V
HC4E-PL-DC24V
HC4E-PL-DC48V
HC4E-PL-DC100V
4 Form C (twin)
Part No.
HC4ED-PL-AC6V
HC4ED-PL-AC12V
HC4ED-PL-AC24V
HC4ED-PL-AC48V
HC4ED-PL-AC100V
HC4ED-PL-AC120V
HC4ED-PL-AC200V
HC4ED-PL-AC240V
HC4ED-PL-DC6V
HC4ED-PL-DC12V
HC4ED-PL-DC24V
HC4ED-PL-DC48V
HC4ED-PL-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
5) TM type
Nominal coil voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1E-HTM-AC6V-F
HC1E-HTM-AC12V-F
HC1E-HTM-AC24V-F
HC1E-HTM-AC48V-F
HC1E-HTM-AC100V-F
HC1E-HTM-AC120V-F
HC1E-HTM-AC200V-F
HC1E-HTM-AC240V-F
HC1E-HTM-DC6V-F
HC1E-HTM-DC12V-F
HC1E-HTM-DC24V-F
HC1E-HTM-DC48V-F
HC1E-HTM-DC100V-F
2 Form C
Part No.
HC2E-HTM-AC6V-F
HC2E-HTM-AC12V-F
HC2E-HTM-AC24V-F
HC2E-HTM-AC48V-F
HC2E-HTM-AC100V-F
HC2E-HTM-AC120V-F
HC2E-HTM-AC200V-F
HC2E-HTM-AC240V-F
HC2E-HTM-DC6V-F
HC2E-HTM-DC12V-F
HC2E-HTM-DC24V-F
HC2E-HTM-DC48V-F
HC2E-HTM-DC100V-F
4 Form C
Part No.
HC4E-HTM-AC6V
HC4E-HTM-AC12V
HC4E-HTM-AC24V
HC4E-HTM-AC48V
HC4E-HTM-AC100V
HC4E-HTM-AC120V
HC4E-HTM-AC200V
HC4E-HTM-AC240V
HC4E-HTM-DC6V
HC4E-HTM-DC12V
HC4E-HTM-DC24V
HC4E-HTM-DC48V
HC4E-HTM-DC100V
4 Form C (twin)
Part No.
HC4ED-HTM-AC6V
HC4ED-HTM-AC12V
HC4ED-HTM-AC24V
HC4ED-HTM-AC48V
HC4ED-HTM-AC100V
HC4ED-HTM-AC120V
HC4ED-HTM-AC200V
HC4ED-HTM-AC240V
HC4ED-HTM-DC6V
HC4ED-HTM-DC12V
HC4ED-HTM-DC24V
HC4ED-HTM-DC48V
HC4ED-HTM-DC100V
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. With diode type (For DC)
1) Plug-in type
2 Form C
Part No.
HC2-DC6V-D-F
HC2-DC12V-D-F
HC2-DC24V-D-F
HC2-DC48V-D-F
HC2-DC100V-D-F
3 Form C
Part No.
HC3-DC6V-D-F
HC3-DC12V-D-F
HC3-DC24V-D-F
HC3-DC48V-D-F
HC3-DC100V-D-F
4 Form C
Part No.
HC4-DC6V-D
HC4-DC12V-D
HC4-DC24V-D
HC4-DC48V-D
HC4-DC100V-D
4 Form C (twin)
Part No.
HC4D-DC6V-D
HC4D-DC12V-D
HC4D-DC24V-D
HC4D-DC48V-D
HC4D-DC100V-D
6V DC
12V DC
24V DC
48V DC
1 Form C
Part No.
HC1-L-DC6V-D-F
HC1-L-DC12V-D-F
HC1-L-DC24V-D-F
HC1-L-DC48V-D-F
2 Form C
Part No.
HC2-L-DC6V-D-F
HC2-L-DC12V-D-F
HC2-L-DC24V-D-F
HC2-L-DC48V-D-F
3 Form C
Part No.
HC3-L-DC6V-D-F
HC3-L-DC12V-D-F
HC3-L-DC24V-D-F
HC3-L-DC48V-D-F
4 Form C
Part No.
HC4-L-DC6V-D
HC4-L-DC12V-D
HC4-L-DC24V-D
HC4-L-DC48V-D
4 Form C (twin)
Part No.
HC4D-L-DC6V-D
HC4D-L-DC12V-D
HC4D-L-DC24V-D
HC4D-L-DC48V-D
100/110V DC
HC1-L-DC100V-D-F
HC2-L-DC100V-D-F
HC3-L-DC100V-D-F
HC4-L-DC100V-D
HC4D-L-DC100V-D
Nominal coil voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HC1-DC6V-D-F
HC1-DC12V-D-F
HC1-DC24V-D-F
HC1-DC48V-D-F
HC1-DC100V-D-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
Nominal coil voltage
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB4E 201302-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
RATING
1. Standard type
1) Coil data
(1) AC coils (50/60Hz)
Nominal coil
voltage
Type
Drop-out
voltage
(at 20°C 68°F)
Pick-up voltage
(at 20°C 68°F)
6V AC
Standard
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
30%V or more
of nominal
voltage
(Initial)
80%V or less of
nominal voltage
(Initial)
Nominal coil current
[±20%] (at 20°C 68°F)
Coil inductance
50Hz
60Hz
N.C.
condition
N.O.
condition
224mA
200mA
0.078H
0.074H
111mA
56mA
28mA
13.4/14.7mA
12.2/13.5mA
6.7/7.4mA
100mA
50mA
25mA
12/13.2mA
10.9/11.9mA
6/6.6mA
0.312H
1.243H
4.974H
23.75H
27.19H
85.98H
0.295H
1.181H
4.145H
20.63H
25.57H
81.76H
Nominal operating
power
50Hz
60Hz
1.3VA
1.2VA
Max. applied
voltage
(at 70°C 158°F)
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow
leading possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
(2) DC coils
Nominal coil
voltage
Type
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
6V DC
Standard
12V DC
24V DC
48V DC
100/110V DC
Nominal coil current
[±10%]
(at 20°C 68°F)
150mA
Coil resistance
[±10%]
(at 20°C 68°F)
40Ω
75mA
37mA
18.5mA
10/11mA
160Ω
650Ω
2,600Ω
10,000Ω
Nominal operating
power
Max. applied voltage
(at 70°C 158°F)
0.9W
110%V of
nominal voltage
1.0W
Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
3. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
2) Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current*4
Nominal operating power
Min. switching capacity
(Reference value)*1
Functional
Destructive
Vibration
resistance
Functional
Destructive
Mechanical
Expected life
Conditions
10A 250V AC
7A 250V AC
7A 250V AC
5A 250V AC
3A 250V AC
2,500VA
1,750VA
1,750VA
1,250VA
750VA
Electrical
Conditions for operation,
transport and storage*3
Max. Operating speed
Unit weight
250VAC
7A
7A
5A
AC (50Hz): 1.3VA, AC (60Hz): 1.2VA, DC: 0.9 to 1.1W
10A
1mA 1V DC
Insulation resistance (Initial)
Between open
contacts
Breakdown
Between contact
voltage
sets
(Initial)
Between contact
and coil
Temperature rise (coil)
(at 70°C 158°F)
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
Shock
resistance
Specifications
2 Form C
3 Form C
4 Form C
4 Form C (twin)
Max. 30 mΩ (By voltage drop 6 V DC 1A)
Ag alloy (cd free) + Au flash
AgNi type + Au clad
1 Form C
3A
100µA 1V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
700 Vrms for 1min. (Detection current: 10mA.)
700 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 80°C 176°F (By resistive method, nominal coil voltage)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Min. 5×107: AC coil type (at 180 times/min.); Min. 108: DC coil type (at 180 times/min.)
Min. 2×105
Min. 2×105
Min. 105
Min. 2×105
Min. 2×105
resistive load
resistive load
resistive load
resistive load
resistive load
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
Ambient temperature: –50°C to +70°C –58°F to +158°F (without LED); –50°C to +60°C –58°F to +140°F (with LED)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 30g 1.06 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket and terminal socket, be sure to verify the max. continuous current.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
Load
Voltage
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C (twin)
AC
Resistive (cos ϕ = 1)
125V AC
250V AC
10A
10A
7A
5A
7A
5A
3A
7A
—
5A
5A
3A
2A
3A
7A
5A
7A
5A
3A
7A
—
5A
5A
3A
2A
3A
DC
Inductive (cos ϕ 0.4)
125V AC
250V AC
5A
3A
3A
2A
3.5A
2.5A
1.5A
—
3.5A
—
2A
1A
0.5A
1A
2.5A
1.5A
2A
1.5A
1A
—
2A
—
1A
0.8A
0.4A
0.8A
Resistive
30V DC
—
Inductive
30V DC
—
Expected life
3A
—
—
3A
—
—
—
3A
—
3A
—
3A
1A
—
—
0.6A
—
—
—
0.4A
—
0.4A
—
—
Min. 5×105
Min. 106
Min. 2×105
Min. 5×105
Min. 106
Min. 105
Min. 2×105
Min. 5×105
Min. 2×105
Min. 5×105
Min. 106
Min. 2×105
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
ASCTB4E 201302-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
2. Amber sealed type
1) Coil data
Same coil data as HC relay standard type. Please refer to standard type information.
2) Specifications
Characteristics
Contact
Rating
Electrical characteristics
Expected life
Conditions
Specifications
2 Form C
4 Form C
4 Form C (twin)
2 Form C
4 Form C
4 Form C
3A 250V AC
2A 250V AC
1A 250V AC
700VA
500VA
250VA
250VAC
250VAC
250VAC
3A
2A
1A
1mA 100mV DC
100µA 100mV DC
Max. 90°C 194°F (By resistive method, nominal voltage)
Min. 2×105 resistive load (at 20 times/min.)
Ambient temperature: –40°C to +60°C –40°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
760mmHg±20% (1,013mb±20%)
Item
1 Form C
1 Form C
5A 250V AC
1,250VA
250VAC
5A
Arrangement
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Temperature rise (coil) (at 60°C 140°F)
Electrical
Conditions for operation, transport and
storage*2
Ambient air pressure
Notes: Other specifications are same as standard types.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
AC
Load
Resistive (cos ϕ = 1)
125V AC
250V AC
5A
5A
Voltage
HC1E
HC2E
HC4E
HC4ED (4 Form C twin)
3A
2A
1A
3A
2A
1A
DC
Inductive (cos ϕ 0.4)
125V AC
250V AC
—
—
—
—
—
Resistive
30V DC
3A
Inductive
30V DC
1A
Expected life
2A
2A
—
0.7A
0.6A
—
Min. 2×105
Min. 2×105
Min. 2×105
—
—
—
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
3. With diode type (For DC)
1) Coil data
Same coil data as HC relay standard type for DC. Please refer to standard type information.
Please connect DC coil type built-in diode correctly by verifying the coil polarity.
2) Specifications
Characteristics
Conditions
Item
Conditions for operation, transport and storage*
Specifications
Ambient temperature: –50°C to +60°C –58°F to +140°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay.
* The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
REFERENCE DATA
Standard type
1. Life curve
2.-(1) Switching capacity range
(single contact type)
Load: 250 V AC resistive load
Mechanical life (DC type)
250
Mechanical life (AC type)
500
400
100
HC4c
250
100
HC2c, 3c
1c
300
AC voltage, V
5,000
AC voltage, V
Life, ×104 times
10,000
2.-(2) Switching capacity range
(4-pole bifurcated (twin) contact type)
(250 V AC cosϕ = 1)
100mV
10
2c
HC1c
200
3c
100
4c
4
6
8
10
1mA
10mA
Load current, A
3.-(1) Coil temperature rise
(1 Form C, AC type)
(See note.)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100
90
90
80
10A
70
7A
5A
2A
0A
60
50
40
Temperature rise, °C
100
100µA
5A 10A
7A
3.-(2) Coil temperature rise
(2 Form C, AC type)
Measured portion: Inside the coil
Ambient temperature: 25°C 77°F
Temperature rise, °C
1A
AC current
(See note.)
Measured portion: Inside the coil
Ambient temperature: 18°C 64°F
10A
80
5A
70
0A
60
50
40
50
40
20
10
10
0
0
90
100
110
0
120
0A
60
10
80
5A
70
30
120
7A
80
20
110
80
Coil applied voltage, %V
Coil applied voltage, %V
90
100
3.-(6) Coil temperature rise
(2 Form C, DC type)
Measured portion: Inside the coil
Ambient temperature: 15 to 21°C 59 to 70°F
(See note.)
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
120
5A
100
3A
80
1A
100
90
90
80
70
60
10A
5A
0A
50
40
60
40
30
20
20
20
10
10
0
0
100
110
120
80
90
100
110
120
Coil applied voltage, %V
3.-(7) Coil temperature rise
(3 Form C, DC type)
3.-(8) Coil temperature rise
(4 Form C, DC type)
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
Measured portion: Inside the coil
Ambient temperature: 17 to 18°C 62 to 64°F
100
90
90
80
7A
70
5A
60
0A
50
40
Temperature rise, °C
100
80
90
100
110
120
Coil applied voltage, %V
When the nominal voltage is applied to AC 120 or
240 V coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
5A
70
60
3A
1A
50
40
30
20
20
0
0
Note: Coil temperature rise
80
30
10
5A
0A
50
40
90
7A
70
30
80
120
80
60
Coil applied voltage, %V
Temperature rise, °C
Temperature rise, °C
140
100
Temperature rise, °C
Temperature rise, °C
3.-(5) Coil temperature rise
(1 Form C, DC type)
160
110
Coil applied voltage, %V
3.-(4) Coil temperature rise
(4 Form C, AC type)
180
(See note.)
90
20
100
10A
100
30
90
3A
3.-(3) Coil temperature rise
(3 Form C, AC type)
30
80
1A
AC current
Temperature rise, °C
2
10
80
90
100
110
120
Coil applied voltage, %V
ASCTB4E 201302-T
Panasonic Corporation
0
80
90
100
110
120
Coil applied voltage, %V
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
Amber sealed type
1.-(1) Switching capacity range
(single contact type)
1.-(2) Switching capacity range
(4-pole bifurcated (twin) contact type)
2.-(1) Coil temperature rise (1 Form C AC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100V
Temperature rise, °C
250V
AC voltage, V
AC voltage, V
100
250
100
HC4E
10V
100mV
HC2E
90
80
70
5A
60
50
40
30
20
HC1E
10
10mA
100µA
1A 2A 3A 5A 10A
AC current
1A
3A
0
10A
80
AC current
90
100
110
120
Voltage applied to coil, %V
2.-(3) Coil temperature rise (4 Form C AC type)
2.-(4) Coil temperature rise (1 Form C DC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100
100
90
90
80
70
3A
60
50
40
(See note.)
100
90
2A
80
70
60
50
40
80
70
60
50
30
30
20
20
20
10
10
80
0
90
100
110
120
Voltage applied to coil, %V
10
80
90
100
110
120
Voltage applied to coil, %V
2.-(5) Coil temperature rise (2 Form C DC type)
Note: Coil temperature rise
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
When the nominal voltage is applied to AC 120 or
240 V coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
100
90
5A
0A
40
30
0
Temperature rise, °C
Temperature rise, °C
(See note.)
Temperature rise, °C
Temperature rise, °C
2.-(2) Coil temperature rise (2 Form C AC type)
0
80
90
100
110
120
Voltage applied to coil, %V
80
70
60
5A
50
40
30
20
10
0
80
90
100
110
120
Voltage applied to coil, %V
With diode type (For DC)
1.-(1) DC coil surge voltage waveform
(without diode)
1.-(2) DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
+
12V DC
–
12V DC
To digital
memory
Panasonic Corporation
–
To digital
memory
breakdown voltage: 1,000 V
(Reverse
(
Forward current: 1 A
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Standard and Amber sealed types
1) Plug-in type
1 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Standard type
27.2
1.071
0.6
.024
2
7
12
13
14
35.2
1.386
1
.039
LED AC type
6.4
.252
2.54
.100
13.35
.526
4.45
4.41
.175
.174
2
7
12
13
14
2
0.5
.020
LED DC type
2
7
7
12
13
( )
∼
12
13
14
( )
14
(+)
(−)
∼
4.06
.160
6.35
.250
6.35
.250
General tolerance: ±0.3 ±.012
2 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Standard type
27.2
1.071
0.6
.024
1
5
9
13
4
8
12
14
35.2
1.386
LED AC type
1
.039
1
5
9
13
( )
6.4
.252
2.54
.100
4.41
13.35
.174
.526
1
4
5
8
9
12
13
14
0.5
.020
LED DC type
4
8
12
∼
1
5
9
13
14
( )
4
8
12
14
(+)
(−)
∼
4.06
.160
6.35
.250
6.35
.250
General tolerance: ±0.3 ±.012
3 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
Schematic (Bottom view)
Standard type
0.6
.024
27.2
1.071
1
2
3
4
5
8
9
7
35.2
1.386
13
1
.039
0.5
.020
2.54
.100
4.41
13.35
.174
.526
2
3
4
5
6
7
8
13
9
14
14
LED AC type
6.4
.252
1
6
2
3
1
2
3
4
5
8
6
4
9
7
5
8
9
7
13
( )
4.06
.160
6.35
.250
6.35
.250
∼
LED DC type
1
14
( )
∼
13
(−)
General tolerance: ±0.3 ±.012
ASCTB4E 201302-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
6
14
(+)
HC
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
1.7
.067
Schematic (Bottom view)
Standard type
20.8
.819
1.7
.067
27.2
1.071
0.6
.024
35.2
1.386
2
3
4
6
7
8
9
10
11
12
13
13
( )
∼
4.06
.160
6.35
.250
6.35
.250
14
4
7
8
9
10
11
12
14
LED DC type
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
9
10
11
12
9
10
11
12
0.5
.020
2.54
.100
4.41
13.35
.174
.526
5
3
6
LED AC type
6.4
.252
1
2
5
13
1
.039
4.45
.175
1
14
( )
∼
13
(−)
14
(+)
General tolerance: ±0.3 ±.012
2) PC board type
4 Form C
External dimensions
CAD Data
20.8
.819
1.7
.067
1.7
.067
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
Types with 0.9 mm terminal width are also
available.
27.2
1.071
0.6
.024
35.2
1.386
1
.039
1.5
.059
13.35
.526
4.45
.175
1
2
3
1.5
.059
0.5
.020
4.41
.174
4
5
6
7
8
9
10
11
12
13
3.5
.138
14
4.06
.160
6.35
.250
6.35
.250
General tolerance: ±0.3 ±.012
PC board pattern
1 Form C
Schematic
2 Form C
4.1
.161
4.1
.161
10.4
.409
16.8
.661
4.45
.175
8.9
.350
13.35
.526
5-2 dia. hole
5-.079 dia.
3 Form C
10.4
.409
16.8
.661
10.4
.409
16.8
.661
8-2 dia. hole
8-.079 dia.
13.35
.526
11-2 dia. hole
11-.079 dia.
Same schematic as plug-in type HC relay
4.1
.161
4.1
.161
10.4
.409
16.8
.661
13.35
.526
4 Form C
4.45
.175
8.9
.350
13.35
.526
14-2 dia. hole
14-.079 dia.
Tolerance: ±0.1 ±.004
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
HC
3) TM type
4 Form C
External dimensions
CAD Data
20.6
.811
43
1.693
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
2
.079
34.2
1.346
1
.039
6.4
.252
2.54
0.5
.100 .020
13.35
.526
4.45
.175
4.31
.170
3.6
.142
1
2
3
4
5
6
7
8
9
10
11
12
13
14
4.06
.160
37.6
6.35 27 1.480
.250 1.063
6.35
.250
General tolerance: ±0.3 ±.012
Chassis (Panel) cutout
Chassis (Panel) cutout in tandem mounting
23
.906
2-3.6 dia.
2-.142 dia.
37.6
1.480
37.6
1.480
Tolerance: ±0.1 ±.004
Schematic
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with
built-in diode types.
21
.827
2
.079
21
.827
Notes: 1. In mounting, use M3 screws and M3 washers.
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
Moreover, use washers to prevent loosening.
With diode type (For DC)
Same dimensions as HC relay standard/plug-in type
CAD Data
Schematic
Without LED indicator
With LED indicator
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
9
10
11
9
10
11
13−
12
+14
13−
12
+14
LED
Protection (surge-absorbing) diode
Protection (surge-absorbing) diode
ASCTB4E 201302-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
HC
SAFETY STANDARDS
Item
1 Form C
UL/C-UL (Recognized)
File No.
Contact rating
E43028
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
E43028
HC
Standard
E43028
3 Form C
E43028
4 Form C twin
E43149
E43028
1 Form C
E43028
2 Form C
HC Amber
E43028
4 Form C
4 Form C twin
E43149
E43028
1 Form C
E43028
2 Form C
HC with
diode type
3 Form C
(For DC)
E43028
E43028
4 Form C
4 Form C twin
LR26550
etc.
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
6A 250V AC
1/6HP 125, 250V AC
3A 30V DC
4A 250V AC
1/10HP 125, 250V AC
3A 30V DC
2A 250V AC
1/20HP 125, 250V AC
2A 30V DC
1A 250V AC
1A 30V DC
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
LR26550
etc.
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
6A 250V AC
1/6HP 125, 250V AC
3A 30V DC
4A 250V AC
1/10HP 125, 250V AC
3A 30V DC
2A 250V AC
1/20HP 125, 250V AC
2A 30V DC
1A 250V AC
1A 30V DC
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
3A 250V AC
3A 30V DC
16
4 Form C
E43149
CSA (Certified)
Contact rating
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
7A 250V AC
/ HP 125, 250V AC
3A 30V DC
16
2 Form C
File No.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
File No.
40017406
40017406
—
VDE (Certified)
Contact rating
10A 250V AC (cosφ =1.0)
3A 250V AC (cosφ =0.4)
3A 30V DC (0ms)
7A 250V AC (cosφ =1.0)
2A 250V AC (cosφ =0.4)
3A 30V DC (0ms)
—
40017406
5A 65V AC (cosφ =1.0)
3A 65V AC (cosφ =0.4)
3A 30V DC (0ms)
TV rating (UL/CSA)
File No.
Rating
UL
TV-3
E43149
CSA
LR26550
UL
TV-3
E43149
CSA
LR26550
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Remarks
NOTES
1. Amber sealed type
When mounting TM types, use washers
to prevent damage or distortion to the
polycarbonate cover. When tightening
fixing screws, the optimum torque range
should be 0.294 to 0.49 N·m, (3 to 5
kgf·cm). If screws are over tightened, the
cover may distort, resulting in poor
sealing. Moreover, to prevent loosening,
use washers.
Panasonic Corporation
2. Diode characteristics
1) Reverse breakdown voltage: 1,000 V
2) Forward current: 1 A
3. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB4E 201302-T
Similar pages