ACDC 560 Watts DNR Series xppower.com • Rugged Design for Industrial Applications • Up to 89% Efficiency • Full Power to +60 °C • Wide Adjustment Range • DC OK 24 V Models • DC Standby Versions • 3 Year Warranty Specification Input General • 90-264 VAC, 120-375 VDC (DNR05/10/18) 85-264 VAC, 90-375 VDC (DNR30/60) Input Frequency • 47-63 Hz Input Current • See tables Inrush Current • 5-18 W: 10/18 A at 115/230 VAC 30 W: 20/40 A at 115/230 VAC 60 W: 30/60 A at 115/230 VAC Power Factor • EN61000-3-2, class A Earth Leakage Current • 0.8 mA max Input Protection • Internal fuse T2A, 250 VAC fitted in line Input Voltage Switching Frequency Signals MTBF DIN Rail Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay • • • • • Start Up Rise Time Hold Up Time • • Line Regulation • Load Regulation • Parallel Operation • Transient Response • Ripple & Noise • Overvoltage Protection • Overload Protection Efficiency Isolation • Short Circuit Protection • Temperature • Coefficient See tables See tables ±1% No minimum load required <1 s (may increase at low temperature extremes) <150 ms 30/130 ms at 115/230 VAC (DNR05) 25/100 ms at 115/230 VAC (DNR10) 20/75 ms at 115/230 VAC (DNR18) 20/30 ms at 115/230 VAC (DNR30) 20/30 ms at 115/230 VAC DNR60) 5-18 W: ±1.0% max 30-60 W: ±0.5% max 5-18 W: ±2.0% max 30-60 W: ±0.5% max Redundancy module DPM10 available for load currents up to 10 A (not with standby system), contact sales 4% max deviation recovery to within 1% in 2 ms for a 50% load change 50 mV pk-pk, 20 MHz bandwidth (may increase at low temperature extremes) Output clamps at 120-145% Vnom, auto recovery 110-145% constant current (DNR05-18) 105-150% power limited (DNR30/60) Power limited, auto recovery ±0.03%/°C • See tables • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground • 132 KHz typical, 55-90 kHz (DNR60) • DC ON indicator LED Green: All models DC LOW indicator LED Red: 5-18 W models DC OK: 24 V 30-60 W models DC OK: All standby models • 800 kHrs typical Bellcore, Issue 6 at +40 °C, GB (DNR05/10/18), 530 kHrs typical Bellcore, Issue 6 at +40 °C, GB (DNR30/60) • Compatible with TS35/7.5 or TS35/15 Environmental Operating Temperature • -20 °C to +70 °C (DNR05/10/18) -40 °C to +70 °C, start up at -35 °C (DNR30/60), all units derate linearly from 60 °C (see derating curves) Cooling • Convection-cooled with 25mm free space all sides Operating Humidity • 20-95% RH, non-condensing Storage Temperature • -25 °C to +85 °C (DNR05/10/18) -40 °C to +85 °C (DNR30/60) Shock • 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis in both directions Vibration • 2 g, 10 Hz to 500 Hz, along X, Y & Z axis, 60 mins/axis, mounted on rail EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge • • • • • • • Conducted Immunity Magnetic Field Dips & Interruptions • • • Safety Approvals • EN55022, level B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, level 4, Perf Criteria A EN61000-4-3, level 3, Perf Criteria A EN61000-4-4, level 4, Perf Criteria A EN61000-4-5, installation class 3, Perf Criteria A EN61000-4-6, level 3, Perf Criteria A EN61000-4-8, level 4 Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B EN60950-1, UL508 Pollution Degree 2, UL1310 class 2 power recognised, See note 3 & ratings table, UL60950-1 Overvoltage Category II, UL508 Overvoltage Category III, DNR30 & DNR60: SEMI F47 ANSI/ISA 12.12.01. Class 1, Division 2 Groups A,B,C and D Output Voltage 5V 12 V 15 V 24 V Input Current (typ.) 115 VAC 230 VAC 0.12 A 0.08 A 0.12 A 0.08 A 0.12 A 0.08 A 0.12 A 0.08 A Output Voltage Trim 4.50-5.75 V 10.80-13.80 V 13.50-17.25 V 21.60-28.80 V Output Current Efficiency (typ.) Model Number 1.000 0.420 0.340 0.210 A A A A 69% 72% 72% 72% DNR05US05(1) DNR05US12(1) DNR05US15(1) DNR05US24(1) 5 12 15 24 V V V V 0.20 0.20 0.20 0.20 A A A A 0.13 0.13 0.13 0.13 A A A A 4.50-5.75 10.80-13.80 13.50-17.25 21.60-28.80 V V V V 2.000 0.840 0.670 0.420 A A A A 73% 75% 76% 76% DNR10US05(1) DNR10US12(1) DNR10US15(1) DNR10US24(1) 5 12 15 24 V V V V 0.36 0.36 0.36 0.36 A A A A 0.21 0.21 0.21 0.21 A A A A 4.50-5.75 10.80-13.80 13.50-17.25 21.60-28.80 V V V V 3.000 1.500 1.200 0.750 A A A A 75% 77% 77% 77% DNR18US05(1) DNR18US12(1) DNR18US15(1) DNR18US24(1) 5 12 24 48 V V V V 0.56 0.56 0.56 0.56 A A A A 0.33 0.33 0.33 0.33 A A A A 5.00-5.50 12.00-14.00 24.00-28.00 48.00-55.00 V V V V 6.000 2.500 1.250 0.625 A A A A 79% 84% 86% 86% DNR30US05(1,3,4) DNR30US12(1,3,4) DNR30US24(1,3,4) DNR30US48(1,3,4) 5 12 24 48 V V V V 1.10 1.10 1.10 1.10 A A A A 0.59 0.59 0.59 0.59 A A A A 5.00-5.50 12.00-14.00 24.00-28.00 48.00-55.00 V V V V 10.000 5.000 2.500 1.250 A A A A 79% 86% 89% 89% DNR60US05(1,3,4) DNR60US12(1,3,4) DNR60US24(1,3,4) DNR60US48(1,3,4) Notes 1. Add suffix ‘-S’ for spring clamp connection option. 2. 30-60 W models are suitable for battery-charging applications. 3. Approved to UL1310, but 5 & 12 V not Class 2 Power recognised. 4. SEMI F47 compliant. Derating Curves , DNR0518 W Models 100 Load (%) 80 60 40 20 0 -20 DNR3060 W Models 0 10 20 0 10 20 30 40 50 60 70 30 40 50 60 70 100 Load (%) 80 60 40 20 0 -40 Ambient Temp (˚C) ACDC DNR0560 Models and Ratings ACDC DNR0560 Mechanical Details DNR05/10/18 W Models 0.89 (22.5) 2 4.53 (115.0) 1 -V +V DC Output DC LO 3.48 (88.5) ON Voltage Trim N L 3 1 AC Input Notes 1. All dimensions in inches (mm). 2. Weight 0.33 lb (150 g) approx. 3. Tolerance: ±0.02 (0.5) maximum. 4. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm) DNR05, 10, 18 Connections Designation Conn Pin 1 Ground AC 2 Neutral Input 3 Line DC 1 Positive 2 Negative Output 30/60 W Models 1.59 (40.5) 4.53 (115.0) 1 5 -V -V +V +V DC OK DC Output Voltage Trim 3.60 (90.0) ON N L 1 3 AC Input Notes 1. All dimensions in inches (mm). 2. Weight 0.8 lb (350 g) approx. 3. Tolerance: ±0.02 (0.5) maximum. 4. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm) DNR30/60 Connections Designation Conn Pin 1 Ground AC 2 Neutral Input 3 Line 1 DC OK* 2 Positive DC 3 Positive Output 4 Negative 5 Negative * 24 V and standby models only. 1 5 Maximum current drain from battery by PSU when inactive 22 mA +V -V -V +V +V DC OK DC Output +V Conn DC OK AC Input Relay Control Coil Voltage Trim D1 e.g. IN4001 LOAD DC Output ON Fuse N L 1 Notes 1. With AC in, unit provides power to the load and to charge the battery. The DC OK signal acts by sensing a voltage on +V and holds the relay closed. 2. With loss of AC in, battery voltage is present on +V. DC OK signal holds the relay closed. Battery supplies power to the load. 3. As the battery discharges, its voltage falls. When this falls below the level shown in the table below the DC OK signal switches off to allow the relay to open to disconnect and protect the battery. Lead Acid Battery -V -V 3 DNR30/60 connection for DC standby system applications AC Input DNR30/60 Connections Pin Designation 1 Ground 2 Neutral 3 Line 1 DC OK 2 Positive 3 Positive 4 Negative 5 Negative Output Set Voltages For Standby Versions Current DC OK Signal Off Model(1) Voltage DNR30US12# 13.6 V 2.20 A 10.30-11.30 V 84% DNR30US24# 27.2 V 1.10 A 21.10-22.10 V 86% DNR30US48# 54.5 V 0.55 A 42.70-43.70 V 86% DNR60US12# 13.6 V 4.40 A 10.30-11.30 V 86% DNR60US24# 27.2 V 2.20 A 21.10-22.10 V 89% DNR60US48# 54.5 V 1.10 A 42.70-43.70 V 89% (2) Efficiency Notes 1. Suffix # indicates standby version. 2. Not UL1310 approved. DC OK 30/60 W Models Output good = 24 V Output not good = 0 V RL > 700Ω N/O N/C DCOK 22 K 0.5 W Coil Coil DCOK -Vout Common Example using external relay to create volt-free contact -Vout 5.1 V 0.3 W Example using external components to create TTL signal Standard on 24 V models, 30-60 W only. 21-Jan-11 ACDC DNR0560 Standby Versions