MORNSUN K78L15-500R3 Support the negative output Datasheet

DC/DC Converter
K78Lxx-500R3 Series
FEATURES
Wide input voltage , non-isolated & regulated single
output
 High efficiency up to 95%
 No-load input current as low as 0.2mA
 Operating temperature range: -40℃ to +85℃




Support the negative output
Output short circuit protection
Pin-out compatible with LM78XX linear regulators
UL60950, EN60950 approval
RoHS
K78Lxx-500R3 series are high efficiency switching regulators and ideal substitutes of LM78xx series three-terminal linear regulators. The
product is featured with high efficiency, low loss, short circuit protection, support the negative output and no heat sink requirement. They
are widely used in industrial control, instrumentation, and electric power applications.
Selection Guide
Certification
Part
Number
K78L03-500R3
K78L05-500R3
UL/CE
K78L12-500R3
K78L15-500R3
Input Voltage (VDC)
Nominal
(Range)
24
(4.75-36)
24
(6.5-36)
12
(7-31)
24
(15-36)
12
(8-24)
24
(19-36)
12
(8-21)
Output
Output Voltage
(VDC)
Max. Output Current
(mA)
Efficiency (%/Typ.)
(Min. Vin)/ (Max. Vin)
@Full Load
Max.
Capacitive
Load(µF)
3.3
500
86/80
680
5.0
500
90/84
680
-5.0
-300
80/81
330
12
500
94/91
680
-12
-150
84/85
330
15
500
95/93
680
-15
-150
85/87
330
Note:For input voltage higher than 30 VDC, a 22uF/50V input capacitor is required.
Input Specifications
Item
Operating Conditions
No-load Input Current
Positive output
Min.
Typ.
Max.
Unit
--
0.2
1.5
mA
Reverse Polarity Input
Forbidden
Input Filter
Capacitor filter
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
K78L03-500R3
--
±2
±4
Others
--
±2
±3
Unit
Output Voltage Accuracy
Full load, input voltage range
Line Regulation
Full load, input voltage range
--
±0.2
±0.4
Load Regulation
Nominal input ,10% -100% load
--
±0.4
±0.6
Ripple & Noise*
20MHz bandwidth, nominal input, 10% -100% load
--
20
75
mVp-p
Temperature Drift Coefficient
Operating temperature -40℃~ +85℃
--
--
±0.03
%/℃
--
50
250
mV
0.2
1
ms
Transient response deviation
Transient recovery time
Output short circuit protection
Nominal input, 25% load step change
Nominal input
--
%
Continuous, self-recovery
Note: *1. Ripple and noise tested with “parallel cable” method, please refer to DC-DC Converter Application Notes for specific operation methods;
*2. With the load lower than 10%, the maximum ripple and noise of 3.3V/5V output products will be 150mVp-p, 12V/15V output products will be 2%Vo.
2015.12.15-A/1
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78Lxx-500R3 Series
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Operating Temperature
Derating if the temperature ≥71℃ (see Fig. 1)
-40
--
85
-55
--
125
260
Storage Temperature
单位
℃
Pin Welding Resistance Temperature
Welding time: 10s (Max.)
--
--
Storage Humidity
Non-condensing
5
--
95
--
850
KHz
--
--
K hours
Switching Frequency
Full load, nominal input
550
MTBF
MIL-HDBK-217F@25℃
2000
%RH
Physical Specifications
Package Dimensions
10.00*7.20*11.00 mm
Weight
1.0g (Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
EMS
Conducted Disturbance
CISPR22/EN55022
CLASS B (see Fig. 5-② for recommended circuit)
Radiated Emission
CISPR22/EN55022
CLASS B (see Fig. 5-② for recommended circuit)
Electrostatic Discharge
IEC/EN 61000-4-2
Contact ±4KV
perf. Criteria B
Radiation Immunity
IEC/EN 61000-4-3
10V/m
perf. Criteria A
EFT
IEC/EN 61000-4-4
±1KV (see Fig. 5-① for recommended circuit)
perf. Criteria B
Conducted Disturbance Immunity
IEC/EN 61000-4-6
3Vr.m.s
perf. Criteria A
Output Power Percentage(%)
Product Characteristic Curve
120
Temperature Derating Curve
100
80
60
40
The Wind Speed:0.8 m/ s
20
0
-40
0
40
71 85
120
Operatin g Temper atu re ( ℃)
Fig. 1
2015.12.15-A/1
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78Lxx-500R3 Series
Design Reference
1. Typical application circuit
1
+Vin
C1
GND
3
DC/D C
1
+Vin
+Vout
C1
2
C2
3
1
DC/DC
GN D
2
C3
GND
Sheet 1
+Vout
3
C4
C2
Negative output application circuit
Fig. 2 Typical application circuit
+Vin
-Vout
GN D
GND
Positive output application circuit
2
DC / DC
C1/C3
(ceramic capacitor)
Part No.
GND
C2/C4
(ceramic capacitor)
22μF/10V
K78L03-500R3
LDM
1
DC/DC
K78L05-500R3
-Vout
2
22μF/25V
22μF/25V
K78L15-500R3
3
C1
22μF/10V
10μF/50V
K78L12-500R3
C2
Fig. 3 Positive and Negative output parallelling application circuit
Note:
1. C1 and C2(C3 and C4) are required and should be connected close to the pin terminal of the module.
2. The capacitance of C1 and C2(C3 and C4) refer to Sheet 1, it can be increased properly if required, and tantalum or low ESR electrolytic capacitors may also
suffice.
3. When the products used as the circuit like figure 3, an inductor named as LDM up to 10μH is recommended in the circuit to reduce the mutual interference.
4. Cannot be used in parallel for output and hot swap.
To reduce the output ripple furtherly, it is suggested to connect a “LC” filter at the output terminal, and recommended value of L is
10µH-47µH.
+Vin
1
C1
DC/DC
L
Vout
3
2
+Vin
C2
1
负
载
22μ F
DC/DC
2
3
C1
L
Vout
C2
22μ F
负
载
GND
GND
Positive output
Negative output
Fig. 4 “LC” filter application circuit
2. EMC solution-recommended circuit
FUSE
L DM 1
L DM 2
V in
Vin
C0
+Vo
GN D
+
M OV
DC/DC
C1
C5
C2
L OAD
GN D
①
②
Fig. 5 EMC recommended circuit
2015.12.15-A/1
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78Lxx-500R3 Series
FUSE
Selected based on the actual
input current from the customer
MOV
LDM1
C0
C1/C2
C5
LDM2
S20K30
82µH
680µF /50V
Refer to Sheet 1
4.7µF /50V
12µH
Note: Part ① in the Fig. 5 is for EMS test, part ② is for EMI filtering; parts ① and ② can be added based on actual requirement.
3. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1. Packing information please refer to Product Packing Information. Packing bag number: 58010116;
2. The max. capacitive load should be tested within the input voltage range and under full load conditions;
3. Without any special statement,all indexes are only specific to positive output application;
4. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25℃, humidity<75% when inputting
nominal voltage and outputting rated load;
5. All index testing methods in this datasheet are based on our Company’s corporate standards;
6. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact with our technician for specific information;
7. Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.12.15-A/1
Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages