ACDC 120 Watts AML120 Series xppower.com • Energy Star Level V ≥18 V • CEC 2008 & EISA 2007 Compliant ≥15V • High Power Density • Single Outputs from 15 V to 48 V • High Efficiency • 0 °C to +70 °C Operating Temperature • Nonstandard Connectors Available Specification Input General • 90-264 VAC • 47-63 Hz • 1.6 A rms at 115 VAC, 0.8 A rms at 230 VAC Inrush Current • 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C Power Factor • 0.98 typical at 115 VAC Earth Leakage Current • 150 µA max at 115 VAC, 60 Hz 250 µA max at 230 VAC, 50 Hz Input Protection • Internal 3 A fuse Standby Power • <0.5 W Consumption Input Voltage Input Frequency Input Current Output 15 to 48 VDC Not user-adjustable ±2% No minimum load required 2 s max at 115 VAC <80 ms at 115 VAC 15 ms minimum at full load and 115 VAC ±0.5% maximum See table 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 2% max pk-pk (see note 1) Overvoltage Protection • 110-140% Vnom, recycle input to reset Overtemperature • Unit shuts down, recycle input to reset Protection Overload Protection • 110-150%, auto recovery Short Circuit Protection • Trip and restart (Hiccup mode) Temperature • 0.04%/°C Coefficient Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • • Efficiency Isolation Switching Frequency Power Density MTBF • 87% typical, 80% min for 15 V models • 3000 VAC Input to Output 1500 VAC Input to Ground Output 0 V is electrically connected to Input Ground • 20-110 kHz variable • 4.9 W/In3 • >100 kHrs per MIL-HDBK-217F Environmental Operating Temperature • 0 °C to +70 °C, derate from 100% power at +50 °C to 60% power at +70 °C Cooling • Convection-cooled Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -20 °C to +80 °C Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • EN55022/FCC/VCCI, Class B conducted EN55022/FCC/VCCI, Class B radiated • EN61000-3-2 • EN61000-3-3 • EN61000-4-2, level 3 Perf Criteria A • EN61000-4-3, level 3 Perf Criteria A • EN61000-4-4, level 2 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN61000-4-6, 10 V Perf Criteria A • EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • EN60950, UL60950, CSA22.2 No. 60950 per cUL, CE Mark Output Power 105 W 120 W 120 W 120 W 120 W 120 W 120 W 120 W Output Voltage 15 V 18 V 19 V 20 V 24 V 30 V 36 V 48 V Total Reguaion(2) 5% 5% 5% 5% 5% 5% 5% 5% Output Current 7.00 A 6.67 A 6.32 A 6.00 A 5.00 A 4.00 A 3.34 A 2.50 A Model Number AML120PS15 AML120PS18 AML120PS19 AML120PS20 AML120PS24 AML120PS30 AML120PS36 AML120PS48 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. Mechanical Details Cable length approx 71” (1800mm) 1 3 2 4 1.46 Power On Indicator (37.0) Pin 1 2 3 4 Shell 6.58 (167.0) Rubber foot (4 places.) Function Return/Input Earth Output + Return/Input Earth Output + Return/Input Earth 0.02 (0.5) 2.56 (65.0) AC Input IEC 320-C6 Inlet (Mates with a C5 plug) Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Maximum load per pin on output connector is 5 A. 3. Optional output connectors available. Consult sales. 4. Output connector is non locking 4 pin DC power plug and mates with Kycon part KPJ-4S or equivalent. 24-Oct-13 ACDC AML120 Models and Ratings