AIMTEC AM3GW-4812DZ 3 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM3GW-Z
3 Watt | DC-DC Converter
FEATURES:




SIP9 Package
Low Ripple and Noise
Continuous Short Circuit Protection
-40ºC to +85ºC Operating Temperature Range
 Ultra-Wide Input Range 4:1
 1500VDC I/O Isolation
 Efficiency up to 84%
 Remote ON / OFF Control
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
Max (mA)
Maximum
Capacitive
Load (µF)
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
3.3
5
12
15
3.3
5
12
15
700
600
250
200
700
600
250
200
2200
1000
165
100
2200
1000
165
100
Input
Voltage (V)
Output
Voltage
(V)
Output Current
Max (mA)
Maximum
Capacitive
Load (µF)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±300
±125
±100
±300
±125
±100
±470
±100
±47
±470
±100
±47
AM3GW-2403SZ
AM3GW-2405SZ
AM3GW-2412SZ
AM3GW-2415SZ
AM3GW-4803SZ
AM3GW-4805SZ
AM3GW-4812SZ
AM3GW-4815SZ
Input Current
Full Load | No
Load (mA)
125
153
149
148
65
78
75
75
10
10
10
10
5
5
5
5
Efficiency
(%)
77
82
83
83
78
84
84
82
Models
Dual output
Model
AM3GW-2405DZ
AM3GW-2412DZ
AM3GW-2415DZ
AM3GW-4805DZ
AM3GW-4812DZ
AM3GW-4815DZ
Input Current
Full Load | No
Load (mA)
155
149
149
78
75
76
10
10
10
5
5
5
Efficiency
(%)
81
84
83
82
82
83
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters
Voltage Range
Filter
Start Up Time
Absolute Maximum Rating
Peak Input Voltage Time
On/Off Control
Input Reflected Ripple Current
Nominal
24
48
Typical
Maximum
9-36
18-75
Capacitor
10
Units
VDC
ms
50
VDC
100
100
ms
ON: 0 to 0.6VDC (or open) ; OFF:2.7 to 15.0VDC, OFF idle current: 5mA, max
20
mA p-p
24
48
Isolation Specifications
Parameters
Tested I/O Voltage
Resistance
Capacitance
www.aimtec.com
F 051e R11.G
Conditions
Typical
60 sec
>1000
500
Tel: +1 514 620 2722
1 of 5
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3GW-Z
3 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage Accuracy
Cross Regulation
(Dual Output Models)
Short Circuit Protection
Short Circuit Restart
Line Voltage Regulation
Typical
25% load on one output - 100% load on
second load
Hiccup
Load Voltage Regulation
Ripple & Noise
Transient Response Deviation
Transient Recovery Time
Maximum
Units
±1
%
±5
%
Continuous
Auto-Recovery
LL~HL
±0.5
From 10% to 100% load
±0.5
From 0% to 100% load 12Vout and 15Vout
±0.5
From 0% to 100% load 3.3Vout and 5Vout
±1
20MHz Bandwidth
50
±3
300
%
%
mV p-p
%
µs
General Specifications
Parameters
Switching Frequency
Operating Temperature
Storage Temperature
Temperature Coefficient
Maximum Case Temperature
Derating
Cooling
Humidity
Case Material
Potting Material
Weight
Dimensions (L x W x H)
MTBF
Max Soldering Temperature
Conditions
Typical
100% load
250
Maximum
-40 to 85
-40 to +125
±0.02
100
Above 75°C
3.5
Free Air Convection
95
Non conductive black plastic
Epoxy (UL94V-0 rated)
6.5
1.02 x 0.36 x 0.49 inches
25.91 x 9.14 x 12.44 mm
>1,212,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
1.5mm from case 10 second
260
Units
KHz
oC
oC
%/oC
oC
%/°C
% RH
g
oC
Safety Specifications
Parameters
Agency Approval
CE
EN55022 Class A,
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: designed to meet IEC 60950-1:2001
Standards
Pin Out Specifications
Pin
1
2
3
6
7
8
9
Single
- V Input
+ V Input
On/Off Control
+ V Output
NC
NC
- V Output
www.aimtec.com
F 051e R11.G
Dual
- V Input
+ V Input
On/Off Control
+ V Output
Common
NC
-V Output
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3GW-Z
3 Watt | DC-DC Converter
Dimensions
All dimensions are in millimeters (inches)
Pin diameter: 1.0 ±0.05 ( 0.04 ±0.002 )
Pin pitch tolerance: ±0.35 ( ±0.014 )
Case Tolerance: ±0.5 ( ±0.02 )
Derating
www.aimtec.com
F 051e R11.G
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3GW-Z
3 Watt | DC-DC Converter
Conducted Emissions
Models
AM2GW-24XX-Z
AM2GW-48XX-Z
C1
1210,225K/100V,X7R, 2pcs
1210,105k/100V,X7R
L1
6.8µH
56µH
Input Reflected Ripple Current
www.aimtec.com
F 051e R11.G
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3GW-Z
3 Watt | DC-DC Converter
Typical Efficiency Example Charts
Eff %
AM3GW‐2405SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
80%
100%
Loading %
Eff %
AM3GW‐4815SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
80%
100%
Loading %
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.G
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages