Skyworks AS204-80LF Gaas ic sp4t nonreflective switch with driver 300 khz-3.5 ghz Datasheet

DATA SHEET
AS204-80, AS204-80LF: GaAs IC SP4T Nonreflective
Switch With Driver 300 kHz–3.5 GHz
Features
Simplified Block Diagram
Integrated driver 5 V supply voltage
● High isolation (45 dB @ 0.9 GHz)
● Low insertion loss (0.5 dB @ 0.9 GHz)
● SSOP-16 plastic package
● Nonreflective all ports
● ESD rated at class 1A HBM
● Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
●
J1
50
J5
J2
J4
J3
50
Description
The AS204-80 is a high-isolation SP4T FET IC nonreflective
switch with driver. The insertion loss is 0.5 dB and isolation is
45 dB at 0.9 GHz. The switch is ideal for cellular base station
switch matrices.
NEW
50
50
2:4 Decoder
CTL1
VCC
CTL2
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 °C
VCC = 5 V, ZO = 50 Ω, unless otherwise noted
Parameter(1)
Insertion
loss(2)
Frequency
Min.
300 kHz–1.0 GHz
300 kHz–2.0 GHz
300 kHz–2.5 GHz
300 kHz–3.5 GHz
Max.
Unit
0.4
0.6
0.7
0.9
0.6
0.8
0.9
1.2
dB
dB
dB
dB
Isolation
300 kHz–1.0 GHz
300 kHz–2.0 GHz
300 kHz–2.5 GHz
300 kHz–3.5 GHz
VSWR(3) on state
300 kHz–3.5 GHz
1.3:1
VSWR(3)
0.5 GHz–3.5 GHz
1.5:1
off state
40
30
28
22
Typ.
45
38
32
25
dB
dB
dB
dB
1. All measurements made in a 50 Ω system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Input/Output.
BUY
NOW
Innovation to GoTM
Now available for purchase online.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200106 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 18, 2007
1
DATA SHEET • AS204-80, AS204-80LF
Operating Characteristics at 25 °C
VCC = 5 V, ZO = 50 Ω, unless otherwise noted
Parameter
Condition
Switching characteristics
Rise, fall
On, off
Video feedthru
Frequency
Min.
10/90% or 90/10% RF
50% CTL to 90/10% RF
TRISE = 1 ns, BW = 500 MHz
Max.
75
125
50
Input power for 1 dB compression
Intermodulation intercept point (IP3)
Typ.
For two-tone input power 13 dBm
ns
ns
mV
0.5–2 GHz
26
dBm
0.5–2 GHz
0.05 GHz
40
29
dBm
dBm
Thermal resistance
30
Control voltages(1)
CTL1, 2 low
CTL1, 2 high
°C/W
0
2.4
Supply voltage, VCC(1)
0.5
5.0
4.8
Supply current
Unit
VCC = 5 V
V
V
5.2
500
µA
1. VCC must be powered on by a minimum of 10 ns prior to VCTL.
Typical Performance Data
VCC = 5 V, ZO = 50 Ω, unless otherwise noted
-20
-30
-0.2
J1–J3
-0.4
J1–J2
J1–J5
J1–J4
-0.6
Isolation (dBm)
Insertion Loss (dBm)
0
-40
J1–J5
-50
J1–J2
-60
J1–J4
-70
J1–J3
-0.8
-80
-1.0
-90
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Isolation vs. Frequency
2.0
VSWR
1.8
1.6
J2–J5_ON (lS22l)
J2–J5_Off
1.4
J2–J5_On (lS11l)
1.2
1.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Frequency (GHz)
VSWR vs. Frequency
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
April 18, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200106 Rev. B
3.0
3.5
DATA SHEET • AS204-80, AS204-80LF
CBL
GND
CTL1
CTL2
CBL
12
GND
11
50 Ω
10
9
2:4 TTL
Decoder
J2
J3
DC blocking capacitors (CBL) required for positive voltage operation.
CBL = 47 pF for operation frequency >500 MHz.
Truth Table
Insertion
Loss
Path J1 to:
Control Input
CTL1
CTL2
J2
0
0
J3
1
0
J4
0
1
J5
1
1
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
“0” = 0 to 0.5 V.
“1” = 2.4 to 5 V.
Recommended Solder Reflow Profiles
SSOP-16 (-80)
Refer to the “Recommended Solder Reflow Profile”
Application Note.
13
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
GND
GND
14
Class 1A
15
-65 °C to +150 °C
ESD human body model
GND
VCC
8
Storage temperature
CBL
7
-40 °C to +85 °C
GND
6
Operating temperature
CBL
5
-0.2 V, +6 V
50 Ω
4
Control voltage
J4
3
6V
GND
GND
2
Supply voltage
J5
CBL
50 Ω
J1
16
Value
0.8 W > 500 MHz
0.2 W @ 50 MHz
1
Characteristic
RF input power
Pin Out
50 Ω
Absolute Maximum Ratings
0.197 (5.00 mm)
0.189 (4.80 mm)
0.025
(0.635 mm) Typ.
Pin 16
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
0.244 (6.20 mm)
0.228 (5.80 mm)
0.158 (4.00 mm)
0.150 (3.80 mm)
Pin 1
0.0196 X 45˚
Chamfer
R 0.013/
0.008
0.068
(1.73 mm) Max.
R 0.008
Min.
0.0098
(0.25 mm)
5˚ -15˚
0.010
(0.25 mm)
Typ.
0.010 (0.25 mm)
0.004 (0.10 mm)
0.050 (1.27 mm)
0.016 (0.40 mm)
8˚ Max.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200106 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 18, 2007
3
DATA SHEET • AS204-80, AS204-80LF
Copyright © 2002, 2003, 2004, 2005, 2006, 2007, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
April 18, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200106 Rev. B