ZETTLER AZ830-2C-5DSE Polarized dip relay single side stable Datasheet

AZ830
POLARIZED DIP RELAY
SINGLE SIDE STABLE
FEATURES
•
•
•
•
•
•
•
•
•
•
Low profile for compact board spacing
DC coils to 48 VDC
High sensitivity, 100 mW pickup
Meets FCC Part 68.302 1500 V lightning surge
Meets FCC Part 68.304 1000 V dielectric
Life expectancy to 100 million operations
High switching capacity, 60 W, 125 VA
Fits standard 16 pin IC socket
Epoxy sealed
UL file E43203 (UL1950); CSA file LR 88413
CONTACTS
Arrangement
DPDT (2 Form C)
Bifurcated crossbar contacts
Ratings
Resistive load:
Max.
Max.
Max.
Max.
Rated Load
UL
Material
Resistance
switched power: 60 W or 125 VA
switched current: 2 A
switched voltage: 250 VDC or 300 VAC
carry current: 3A
2 A at 30 VDC
1 A at 120 VAC
Silver alloy, gold clad. Silver palladium, gold clad
available upon request (not recommended for
current greater than 1 Amp).
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 108
1 x 105 at 2 A, 30 VDC or 1 A, 125 VAC
2 x 106 at 1 A, 30 VDC or .5 A, 125 VAC
(see table for additional figures)
Operate Time (typical)
3 ms at nominal coil voltage
Release Time (typical)
2 ms at nominal coil voltage
(with no coil suppression)
Capacitance
Contact to contact: 1.0 pF
Contact set to contact: 1.0 pF
Contact to coil: 2.0 pF
Bounce (typical)
At 10 mA contact current
1.5 ms at operate N.O. side
2.5 ms at operate N.C. side
Dielectric Strength
(at sea level)
1500 Vrms contact to coil
1000 Vrms between contact sets
1000 Vrms across contacts
Meets FCC Part 68.302 lightning surge
Meets FCC Part 68.304 V dielectric
Insulation Resistance
1000 megohms min. at 20°C, 500 VDC,
50% RH
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
Operating
At nominal coil voltage
Standard: -40°C (-40°F) to 70°C (158°F)
Sensitive: -40°C (-40°F) to 85°C (185°F)
Both: -40°C (-40°F) to 105°C (221°F)
< 50 milliohms initially
COIL
Power
At Pickup Voltage
(typical)
Standard coil: 200 mW
Sensitive coil: 100 mW
Max. Continuous
Dissipation
1.0 W at 20°C (68°F)
0.9 W at 40°C (104°F)
Temperature Rise
Standard: 38°C (68°F) at nominal coil voltage
Sensitive: 21°C (38°F) at nominal coil voltage
Temperature
Max. 115°C (239°F)
NOTES
1.
2.
3.
4.
All values at 20°C (68°F).
Relay may pull in with less than “Must Operate” value.
Relay has fixed coil polarity.
For complete isolation between the relay’s magnetic fields, it is
recommended that a .197" (5.0 mm) space be provided between
adjacent relays.
5. Relay adjustment may be affected if undue pressure is exerted
on relay case.
6. Specifications subject to change without notice.
ZETTLER
Storage
Vibration
0.062" (1.5 mm) DA at 10–55 Hz
Shock
40 g
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy, P.C.
Max. Solder Temp.
270°C (518°F)
Max. Solder Time
5 seconds
Max. Solvent Temp.
80°C (176°F)
Max. Immersion Time
30 seconds
Weight
5 grams
electronics GmbH
Junkersstrasse 3, D-82178 Puchheim, Germany
Tel. +49 89 800 97 0
Fax +49 89 800 97 200
[email protected]
www.ZETTLERelectronics.com
2003-08-14
AZ830
RELAY ORDERING DATA
TYPICAL CONTACT LIFE EXPECTANCY
NUMBER OF OPERATIONS
STANDARD COIL
COIL SPECIFICATIONS
Nominal
Coil
VDC
5
Max.
Continuous
VDC
7.5
Coil
Resistance
Ohm ± 10%
62.5
Must
Operate
VDC
3.5
ORDER NUMBER*
AZ830–2C–5DE
6
9.0
90
4.2
AZ830–2C–6DE
12
18.0
360
8.4
AZ830–2C–12DE
24
36.0
1,440
16.8
AZ830–2C–24DE
48
72.0
5,760
33.6
AZ830–2C–48DE
AZ830–2C–5DSE
SENSITIVE RELAYS
5
11.0
125
3.5
6
13.0
180
4.2
AZ830–2C–6DSE
12
26.0
720
8.4
AZ830–2C–12DSE
24
53.0
2,880
16.8
AZ830–2C–24DSE
48
106.0
11,520
33.6
AZ830–2C–48DSE
* Add suffix “A” for silver palladium gold clad contacts.
VOLTAGE
POWER
50 mV
30 VDC
30 VDC
30 VDC
60 VDC
60 VDC
60 VDC
30 VAC
30 VAC
30 VAC
60 VAC
60 VAC
60 VAC
125 VAC
125 VAC
125 VAC
50 µW
60 W
40 W
20 W
60 W
40 W
20 W
120 VA
80 VA
40 VA
120 VA
80 VA
40 VA
125 VA
80 VA
40 VA
Maximum Switching Capacity
PC BOARD LAYOUT
.788
(20.0)
.386
(9.8)
.044
(1.1) REF
0.03 DIA
(0.8)
(8 HOLES)
.015
(0.38)
10.0
9.0
8.0
7.0
6.0
5.0
4.0
.044
(1.1) REF
.200
(5.07)
.300
(7.61)
(.024 ± .005)
(0.6 ± 0.13)
TYP
.200
(5.07)
3.0
2.0
0.1
(2.54)
Viewed toward
terminals
.390
(9.9)
Current
.044
(1.1)
INDUCTIVE
LOAD
5 x 107
15 x 104
3 x 105
1 x 106
—
—
—
15 x 104
3 x 105
1 x 106
15 x 104
3 x 105
1 x 106
15 x 104
3 x 105
1 x 106
NOTES: 1. Relays operated at nominal coil voltage.
2. Inductive load tests are at 0.7 power factor.
3. Table represents typical life figures and are not
guaranteed minimums.
MECHANICAL DATA
.138
(3.5)
RESISTIVE
LOAD
5x 107
5 x 105
1 x 106
3 x 106
5 x 105
1 x 106
3 x 106
5 x 105
1 x 106
3 x 106
5 x 105
1 x 106
3 x 106
5 x 105
1 x 106
3 x 106
WIRING DIAGRAM
+
1
4
6
AC Resistive Load
1.0
.9
.8
.7
.6
.5
DC Resistive Load
.4
8
.3
.2
400
500
600
700
800
900
300
200
1000
Viewed toward terminals
100
.1
50
60
70
80
90
9
40
11
30
13
(WATCH FOR POLARITY)
20
16
.012 ± .005
(0.3 ± 0.13)
TYP
10
–
Voltage
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
Coil Temperature Rise
Sensitive
Standard
60
110
Full Load
Full Load
90
Coil Temperature Rise ˚C
Coil Temperature Rise ˚C
100
80
No Load
70
60
50
40
30
50
No Load
40
30
20
20
10
10
60%
80%
100%
120%
140%
160%
180%
Percent of Nominal Coil Voltage
ZETTLER
60%
8 0%
100%
120%
140%
160%
180%
Percent of Nominal Coil Voltage
electronics GmbH
Junkersstrasse 3, D-82178 Puchheim, Germany
Tel. +49 89 800 97 0
Fax +49 89 800 97 200
[email protected]
www.ZETTLERelectronics.com
2003-08-14
Similar pages