Holt HI-3717A Compliant with arinc 717-15 Datasheet

HI-3717A
Single-Rail ARINC 717 Protocol IC
with SPI Interface
August 2015
GENERAL DESCRIPTION
APPLICATIONS
·
·
·
·
Digital Flight Data Acquisition Units (DFDAU)
Digital Flight Data Recorders (DFDR)
Quick Access Recorders (cassette type)
Expandable Flight Data Acquisition and Recording
Systems
· Compliant with ARINC 717-15 (June 6, 2011)
· Operates from a single +3.3V supply with on-chip
44
43
42
41
40
39
38
37
36
35
34
NOCONV
RINB-40
RINB
RINA
RINA-40
GND
TFIFO
TEMPTY
INSYNC
SYNC0
SYNC1
HI-3717APCI
HI-3717APCT
HI-3717APCM
33
32
31
30
29
28
27
26
25
24
23
-
OUTHA
TXOUTHA
TXOUTHB
OUTHB
TXHB
TXBA
OUTBA
TXOUTBA
TXOUTBB
OUTBB
TXBB
MATCH
RFIFO
ROVF
MR
RSEL
GND
SI
SCK
SO
CS
ACLK
-
12
13
14
15
16
17
18
19
20
21
22
converters to provide proper voltages for both Harvard
Bi-Phase (HPB) and Bi-Polar Return-to-Zero (BPRZ)
outputs
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
· One selectable receive channel as HBP or BPRZ with
integrated analog line receiver
44 - Pin Plastic 7mm x 7mm
Chip-Scale Package (QFN)
· Both HBP and BPRZ transmitters have integrated line
drivers as well as digital outputs
· 32-word by 12-bit FIFOs for both the receive and the
VDD
C1C1+
V+
transmit channel
44
43
42
41
40
39
38
37
36
35
34
-
· Programmable slew rates on transmit channels: 1.5μs,
GND
C2+
C2VTXHA
FEATURES
-
The HI-3717A is available in very small 44-pin 7mm x 7mm
Chip-scale (QFN) and 44-pin Quad Flat Pack (PQFP) plastic
packages.
GND
C2+
C2VTXHA
PIN CONFIGURATIONS (Top View)
VDD
C1C1+
V+
The HI-3717A from Holt Integrated Circuits is a CMOS
device designed for interfacing an ARINC 717 compatible
bus to a Serial Peripheral Interface (SPI) enabled microcontroller. The part includes a selectable Harvard Bi-Phase
(HBP) or Bi-Polar Return-to-Zero (BPRZ) receive channel
and transmit channels with HBP and BPRZ encoders and
line drivers. The receive channel has integrated analog line
receivers and the transmit channels have integrated line
drivers for the corresponding encoding method (HBP and
BPRZ). The part operates from a single +3.3V supply using
only four external capacitors. Each transmit and receive
channel has a 32-word by 12-bit FIFO for data buffering.
3.75μs, 7.5μs or 10μs
· Digital transmitter outputs available for use with
external line drivers
· Programmable bit rates: 384, 768, 1536, 3072, 6144,
12288, 24576, 49152 and 98304 bits/sec (32, 64, 128,
256, 512, 1024, 2048, 4096 and 8192 words/sec)
· Enhanced Sync detection allows multiple false sync
marks in user data while still synchronizing within 8
seconds
· Fast SPI transmitter write and receiver read modes
· Match pin flags when preprogrammed word count /
NOCONV
RINB-40
RINB
RINA
RINA-40
GND
TFIFO
TEMPTY
INSYNC
SYNC0
SYNC1
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
HI-3717APQI
HI-3717APQT
HI-3717APQM
33
32
31
30
29
28
27
26
25
24
23
-
OUTHA
TXOUTHA
TXOUTHB
OUTHB
TXHB
TXBA
OUTBA
TXOUTBA
TXOUTBB
OUTBB
TXBB
( DS 3717A Rev. B)
MATCH
RFIFO
ROVF
MR
RSEL
GND
SI
SCK
SO
CS
ACLK
· Frame / subframe word count indicator
· Industrial and Extended temperature ranges
· Burn-in available
12
13
14
15
16
17
18
19
20
21
22
subframe is received
44 - Pin Plastic Quad Flat Pack (PQFP)
HOLT INTEGRATED CIRCUITS
www.holtic.com
08/15
HI-3717A
BLOCK DIAGRAM
VDD (3.3V)
10uF
0.1uF
CSUPPLY
TXHA
OUTHA
5Ω
Transmit
32 x 12-BIT
FIFO
Transmit
Rate
Selection
HBP
Encoder
Line
Driver
37.5Ω
TXOUTHA
37.5Ω
TXOUTHB
OUTHB
5Ω
Slew
Rate
&
Loopback
Test
Control
TXHB
TXBA
OUTBA
5Ω
BPRZ
Encoder
Line
Driver
37.5Ω
TXOUTBA
37.5Ω
TXOUTBB
OUTBB
5Ω
TXBB
+3.3V
NOCONV
V+
Transmit FIFO
Status Register
TXFSTAT
MR
V+
COUT
VV-
SCK
CS
SI
COUT
DC / DC
Converter
SPI
Interface
C1+
C1-
SO
CFLY+
C2+
ARINC 717
Clock
Divider
ACLK
Control
Register 0
CTRL0
Control
Register 1
CTRL1
C2-
CFLY-
RSEL
Receive FIFO
Status Register
RXFSTAT
FIFO Status Pin
Assignment
Register
FSPIN
Word Count
Utility Register
WRDCNT
MATCH
RFIFO
TFIFO
HBP Line
Receiver
RINA
40 KΩ
RINB
40 KΩ
RINA-40
TEMPTY
HBP / BPRZ
Data
Sampler
RINB-40
HBP / BPRZ
Clock
Recovery
&
Decoder
SYNC
Detect
RECEIVE
32 x 12-BIT
FIFO
ROVF
INSYNC
SYNC1
SYNC0
BPRZ Line
Receiver
GND
FIGURE 1.
HOLT INTEGRATED CIRCUITS
2
HI-3717A
PIN DESCRIPTIONS
SIGNAL
FUNCTION
DESCRIPTION
Internal
Pull-up / Down
NOCONV
RINB-40
RINB
RINA
RINA-40
GND
INPUT
INPUT
INPUT
INPUT
INPUT
POWER
50KΩ pull-down
TFIFO
OUTPUT
TEMPTY
OUTPUT
INSYNC
OUTPUT
SYNC0
OUTPUT
Disables on-chip DC-DC voltage converter
Alternate receiver negative input. Requires external 40K ohm resistor
Receiver negative input. Direct connection to ARINC 717 bus (BPRZ or HBP)
Receiver positive input. Direct connection to ARINC 717 bus (BPRZ or HBP)
Alternate receiver positive input. Requires external 40K ohm resistor
Chip 0V Supply (All GND pins on package must be connected)
Output is user programmable to indicate the Transmit FIFO Full or Half-full state.
See FSPIN<5>, in Table 7, FIFO Status Pin Assignment Register.
Output goes high when the transmit FIFO is empty
Output goes high when the receiver is synchronized to the incoming data. Synchronization occurs at the next valid sync mark following the detection of the proper
number and order of consecutively spaced sync marks. See Table 5.
Output in conjunction with SYNC1 output indicates when each of the four ARINC 717
subframe sync words are received. Only valid in 4 Sync-Word mode when the
INSYNC pin is high.
SYNC1
OUTPUT
MATCH
OUTPUT
RFIFO
OUTPUT
ROVF
OUTPUT
MR
RSEL
SI
SCK
SO
CS
ACLK
INPUT
INPUT
INPUT
INPUT
OUTPUT
INPUT
INPUT
Output in conjunction with SYNC0 output indicates when each of the four ARINC 717
subframe sync words are received. Only valid in 4 Sync-Word mode when the
INSYNC pin is high.
Output goes high when the value of the Frame Word Count Register matches the
value in the Frame Count Utility Register, WRDCNT.
Output is user programmable to indicate the Receive FIFO Full, Half-full or Empty
state. See FSPIN<7:6> in Table 7, FIFO Status Pin Assignment Register.
Receive FIFO Overflow. Output goes high when an attempt is made to load a full
Receive FIFO
Master Reset, active low
Selects either HBP or BPRZ Receiver. OR’d with RXSEL bit in Control Register 0
SPI interface serial data input
SPI Clock. Data is shifted into SI and out of SO when CS is low.
SPI Interface seral data output
Chip Select. Data is shifted into SI and out of SO using SCK when CS is low
Master timing source for receiver and transmitters. 24 MHZ ±0.1%
TA B L E 1 .
HOLT INTEGRATED CIRCUITS
3
50KΩ pull-up
50KΩ pull-down
50KΩ pull-down
50KΩ pull-down
50KΩ pull-up
50KΩ pull-down
HI-3717A
PIN DESCRIPTIONS (cont.)
SIGNAL
FUNCTION
DESCRIPTION
TXBB
OUTPUT
OUTBB
OUTPUT
TXOUTBB
OUTPUT
TXOUTBA
OUTPUT
OUTBA
OUTPUT
TXBA
TXHB
OUTPUT
OUTPUT
OUTHB
OUTPUT
TXOUTHB
TXOUTHA
OUTPUT
OUTPUT
OUTHA
OUTPUT
TXHA
VC2C2+
V+
C1+
C1VDD
OUTPUT
CONVERTER
CONVERTER
CONVERTER
CONVERTER
CONVERTER
CONVERTER
POWER
Bi-Polar Return-to-Zero (BPRZ) digital low output (external line driver required)
Alternate Bi-Polar Return-to-Zero (BPRZ) Line Driver low output. Requires external
32.5 ohm resistor
Bi-Polar Return-to-Zero (BPRZ) Line Driver low output. Direct connect to ARINC 717
bus
Bi-Polar Return-to-Zero (BPRZ) Line Driver high output. Direct connect to ARINC
717 bus
Alternate Bi-Polar Return-to-Zero (BPRZ) Line Driver high output. Requires external
32.5 ohm resistor
Bi-Polar Return-to-Zero (BPRZ) digital high output (external line driver required)
Harvard Bi-Phase (HBP) digital low output (external line driver required)
Alternate Harvard Bi-Phase (HBP) Line Driver low output. Requires external 32.5
ohm resistor
Harvard Bi-Phase (HBP) Line Driver low output. Direct connect to ARINC 717 bus
Harvard Bi-Phase (HBP) Line Driver high output. Direct connect to ARINC 717 bus
Alternate Harvard Bi-Phase (HBP) Line Driver high output. Requires external 32.5
ohm resistor
Harvard Bi-Phase (HBP) digital high output (external line driver required)
DC/DC converter negative voltage
DC/DC converter fly capacitor for VDC/DC converter fly capacitor for VDC/DC converter positive voltage
DC/DC converter fly capacitor for V+
DC/DC converter fly capacitor for V+
Chip +3.3V Supply
TA B L E 1 ( c o n t . ) .
TA B L E 1 .
HOLT INTEGRATED CIRCUITS
4
Internal
Pull-up / Down
HI-3717A
SERIAL PERIPHERAL
INTERFACE (SPI)
SPI BASICS
HI-3717A SPI INSTRUCTIONS
The HI-3717A uses an SPI (Serial Peripheral Interface) for host
access to internal registers and data FIFOs. Host serial
communication is enabled through the Chip Select (CS) pin,
and is accessed via a four-wire interface consisting of Serial
Data Input (SI) from the host, Serial Data Output (SO) to the
host and Serial Clock (SCK). All read / write cycles are
completely self-timed.
Instruction op codes are used to read, write and configure the
HI-3717A. Each SPI read or write operation begins with an 8-bit
instruction. When CS goes low, the next 8 clocks at the SCK
pin shift an instruction op code into the decoder, starting with
the first rising edge. The op code is shifted into the SI pin, most
significant bit (MSB) first. The SPI can be clo cked up to10 MHz.
As seen in Figure 2, SPI Mode 0 holds SCK in the low state
when idle. The SPI protocol transfers serial data as 8-bit bytes.
Once CS is asserted, the next 8 rising edges on SCK latch input
data into the master and slave devices, starting with each byte's
most-significant bit. A rising edge on CS terminates the serial
transfer and re-initializes the HI-3717A SPI for the next transfer.
If CS goes high before a full byte is clocked by SCK, the
incomplete byte clocked into the device SI pin is discarded.
In the general case, both master and slave simultaneously
send and receive serial data (full duplex), per Figure 2 below.
However the HI-3717A operates half duplex, maintaining high
impedance on the SO output, except when actually transmitting
serial data. When the HI-3717A is sending data on SO during
read operations, activity on its SI input is ignored. Figure 3 and
Figure 4 show actual behavior for the HI-3717A SO output.
/W
The SPI protocol defines two parameters, CPOL (clock
polarity) and CPHA (clock phase). The possible CPOL-CPHA
combinations define four possible “SPI Modes”. Without
describing details of the SPI modes, the HI-3717A operates in
Mode 0 where input data for each device (master and slave) is
clocked on the rising edge of SCK, and output data for each
device changes on the falling edge (CPHA = 0, CPOL = 0). The
host SPI logic must be set for Mode 0 for proper
communications with the HI-3717A .
The SPI instructions are of a common format. The most
significant bit (MSB) specifies whether the instruction is a write
“0” or read “1” transfer.
R
The SPI protocol specifies master and slave operation; the
HI-3717A operates as an SPI slave.
MSB
7
X
X
X
X
X
X
X
6
5
4
3
2
1
0
LSB
SPI INSTRUCTION FORMAT
For write instructions, the most significant bit of the data word
must immediately follow the instruction op code and is clocked
into its register on the next rising SCK edge. Data word length
varies depending on word type written: 8-bit Control & Status
Register writes, 16-bit Word Count Utility Register writes and
16-bit Transmit FIFO writes.
For read instructions, the most significant bit of the requested
data word appears at the SO pin at the next falling SCK edge
after the last op code bit is clocked into the decoder. As in write
instructions, the data field bit-length varies with read instruction
type.
Since HI-3717A operates in half-duplex mode, the host
discards the dummy byte it receives while serially transmitting
the instruction op code to the HI-3717A.
SCK (SPI Mode 0)
SI
SO
High Z
MSB
LSB
MSB
LSB
CS
FIGURE 2. Generalized Single-Byte Transfer Using SPI Protocol Mode 0
HOLT INTEGRATED CIRCUITS
5
High Z
HI-3717A
Figure 3 and Figure 4 show read and write timing as it appears
for a single-byte and dual-byte register operation. The
instruction op code is immediately followed by a data byte
comprising the 8-bit data word read or written. For a register
read or write, CS is negated after the data byte is transferred.
Table 2 summarizes the HI-3717A SPI instruction set.
0
1
2
3
4
5
6
7
Note: SPI Instruction op-codes not shown in Table 2 are
“reserved” and must not be used. Further, these op-codes will
not provide meaningful data in response to a read instruction.
Two instruction bytes cannot be “chained”; CS must be negated
after each instruction, and then reasserted for the following
Read or Write instruction.
0
1
2
3
4
5
6
7
SCK
MSB
LSB
SI
Op-Code Byte
LSB MSB
MSB
High Z
SO
High Z
Data Byte
CS
Note: Two instruction bytes cannot be “chained”;
CS must be negated after each instruction, and then
reasserted for the following Read or Write instruction.
FIGURE 3. Single-Byte Read From a Register
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
SCK
SPI Mode 0
MSB
LSB MSB
LSB
LSB MSB
SI
Op-Code Byte
SO
Data Byte 0
Data Byte 1
High Z
CS
Note: Two instruction bytes cannot be “chained”;
CS must be negated after each instruction, and then
reasserted for the following Read or Write instruction.
FIGURE 4. 2-Byte SPI Write Example
HOLT INTEGRATED CIRCUITS
6
HI-3717A
SPI INSTRUCTION SET
OP Code R/W
# Data
bytes
DESCRIPTION
0x64
W
1
Write Control Register 0
0x62
0x6A
0x72
0x74
0x2*
W
W
W
W
W
1
1
2
2
1
Write Control Register 1
Write Receiver FIFO Status Pin Assignment Register
Write Word Count Utility Register
Write Transmit FIFO word
Fast Write Transmit FIFO Word
0xE4
R
1
Read Control Register 0
0xE2
0xE6
0xE8
0xEA
0xF2
0xF6
0xFE
0xC*
R
R
R
R
R
R
R
R
1
1
1
1
2
2
4
1
Read Control Register 1
Read Receive FIFO Status Register
Read Transmit FIFO Status Register
Read Receive FIFO Status Pin Assignment Register
Read Word Count Utility Register
Read Receive FIFO Word
Read Receive FIFO Word and Word Count
Fast Read Receive FIFO
* In the case of FAST instructions, the last four bits of the instruction byte are data
TABLE 2. SPI Instruction Set
HOLT INTEGRATED CIRCUITS
7
HI-3717A
REGISTER DESCRIPTIONS
BR
2
BR
1
BR
0
32
W
SL PS
E
SL W1
E
R W0
XS
EL
CONTROL REGISTER 0: CTRL0
X
Read: SPI Op-code 0xE4
Write: SPI Op-code 0x64
7 6
MSB
5
4
3
2
1
0
LSB
Bit
Name
R/W Default Description
7
-
R/W
0
Not Used. Always reads a “0”
6-4
BR2:0
R/W
0
Setting these bits sets the ARINC 717 data rate for both the receive and transmit data.
000 768 Bits/sec. ( 64 words/sec.)
001 1536 Bits/sec. (128 words/sec.)
010 3072 Bits/sec. (256 words/sec.)
011 6144 Bits/sec. (512 words /sec.)
100 12288 Bits/sec. (1024 words/sec.)
101 24576 Bits/sec. (2048 words/sec.)
110 49152 Bits/sec. (4096 words/sec.)
111 98304 Bits/sec. (8192 words/sec.)
3
32WPS
R/W
0
Setting this bit overrides the state of BR2:0 and sets the data rate at 384 Bits/sec. (32 words/sec.)
2-1
SLEW1:0
R/W
0
Setting these bits controls the nominal slew rate on both the HBP & BPRZ transmit channel outputs.
00
7.5 μs
01
3.75 μs ( ARINC 717 data rates)
10
10.0 μs ( Same as ARINC 429 Low Speed)
11
1.5 μs ( Higher data rates beyond ARINC 717 – same as ARINC 429 High Speed)
0
RXSEL
R/W
0
Selects either the HBP (”0”) or BPRZ (”1”) Receiver. This bit is logically OR’d with the RSEL input
pin.
TABLE 3.
C C
YN YN
ST TS OS ST
SR SF N TE
CONTROL REGISTER 1: CTRL1
X X X X
Read: SPI Op-code 0xE2
Write: SPI Op-code 0x62
7 6
MSB
5
4
3
2
1
0
LSB
Bit
Name
7-4
-
R/W
R/W Default Description
0
Not Used, Always reads a “0”
3
SRST
R/W
0
Software Reset - Setting this bit to “1” empties all the FIFO’s, clears the Sync detection logic and
sets the analog line drivers to Hi-Z state. All other register bits remain unchanged.
2
SFTSYNC
R/W
0
2 Sync-Word Mode: Setting the bit to “1” will result in the INSYNC output pin going high when the
third of three consecutively occurring sync marks is detected.
1
NOSYNC
R/W
0
No Synchronization - Setting this bit to “1” will result in all data captured being loaded into the
receive FIFO. WARNING: In this mode there is no way the HI-3717A can determine frame or subframe boundaries. This sync mode overrides all the other sync modes when set to “1”.
0
TEST
R/W
0
Test Mode - A “1” in this bit position will disable the line receiver and both line drivers and the digital
transmitted data will be looped back to the HBP or BPRZ data sampler selected by RXSEL .
TABLE 4.
HOLT INTEGRATED CIRCUITS
8
HI-3717A
R
FF
C
N C1 C0
SY YN YN
IN S S
X X X X X X X X
Read: SPI Op-code 0xE6
Write: Read Only
Bit
Name
7
INSYNC
Y
F PT F
AL M OV T
S
FH FE F
R R R TE
U
LL
RECEIVE FIFO STATUS REGISTER: RXFSTAT
7 6
MSB
5
4
3
2
1
0
LSB
R/W Default Description
R
0
Receive channel sync indicator. The bit is set to”1” when synchronization is achieved on the
receive channel.
4 Sync-Word Mode occurs when four consecutive valid sync marks (Octal 1107, 2670, 5107 and
6670 respectively) are received exactly 1 second apart. The bit is set when the next valid and
properly spaced subframe sync mark (Octal 1107) is detected.
2 Sync-Word Mode (CTRL1<2> = “1”) occurs when two consecutively valid sync marks are
received exactly 1 second apart and in the proper order but the first sync mark does not have to be
Octal 1107. The bit is set when the next valid and properly spaced subframe sync mark is detected.
The bit remains set until synchronization is lost at which time the device automatically attempts to
re-synchronize. No data is passed to the receive FIFO until Synchronization is re-established.
Existing data in the FIFO remains intact and can be read at any time.
6-5
SYNC0:1
R
0
The two bits are realtime indicators of when each of the four ARINC 717 subframe sync marks are
received. They are updated when the sync mark is detected and passed to the Receive FIFO. The
two bits are only valid in 4 Sync-Word Mode when the INSYNC pin is high. See Application Note
AN-170 for detecting SYNC phase in SFTSYNC mode.
00
Subframe SYNC1 mark received (Octal 1107)
01
Subframe SYNC2 mark received (Octal 2670)
10
Subframe SYNC3 mark received (Octal 5107)
11
Subframe SYNC4 mark received (Octal 6670)
4
RFFULL
R
0
Bit is set when the Receive FIFO contains 32 words.
3
RFHALF
R
0
Bit is set when the Receive FIFO contains exactly 16 words.
2
RFEMPTY
R
1
Bit is set when the Receive FIFO is empty. It is reset to”0” when the first valid word is passed to the
Receive FIFO.
1
RFOVF
R
0
FIFO Overflow bit and ROVF pin are set to “1” when devices attempts to load a valid word to a full
Receive FIFO. The Receive FIFO will ignore additional words if it is full.
0
-
R
0
Not used, Always reads “0”
TABLE 5.
HOLT INTEGRATED CIRCUITS
9
HI-3717A
REGISTER DESCRIPTIONS (cont.)
T
Y
Y
F PT
F PT FW
AL EM
AL M OV ST
H E
H
FF FF FF TE
TF TF
U
LL
F
FI
O
FF
F
TRANSMIT FIFO STATUS REGISTER: TXFSTAT
X X X X X X X X
Read: SPI Op-code 0xE8
Write: Read Only
7 6
MSB
5
4
3
2
1
0
LSB
Bit
Name
7
TFIFO
R/W Default Description
R
0
This bit mirrors the status of the TFIFO pin. See register FSPIN below for TFIFO pin assignment.
6
TFHALF
R
0
Set when the Transmit FIFO contains exactly 16 words
5
TFEMPTY
R
1
Set when the Transmit FIFO is empty. Reset to “0” when at least one word is loaded to the Transmit
FIFO.
4-0
-
R
0
Not used, Always reads “0”
TABLE 6.
TY
0 IGN
LF P VFW T
O
A
M
S
IF A
H E O S
FI
R RF TF
FF FF FF TE
LL
1
U
FO
FF
F
FIFO STATUS PIN ASSIGNMENT
REGISTER: FSPIN
X X X X X X X X
Read: SPI Op-code 0xEA
Write: SPI Op-code 0x6A
7 6
MSB
5
4
3
2
1
0
LSB
Bit
Name
R/W Default Description
7-6
RFIFO1:0
R/W
0
These bits program which Receive FIFO Status Register bit is represented by the RFIFO pin .
00
RFIFO pin is set “1” when Receive FIFO Status Register Bit 2, RFEMPTY, is “1”.
01
RFIFO pin is set “1” when Receive FIFO Status Register Bit 3, RFHALF, is “1”.
10
RFIFO pin is set “1” when Receive FIFO Status Register Bit 3, RFHALF, is “1”.
11
RFIFO pin is set “1” when Receive FIFO Status Register Bit 4, RFFULL, is “1”.
5
TFASIGN
R/W
0
This bit programs the TFIFO pin to reflect the Transmit FIFO Status (FIFO Full or FIFO Half-Full).
0
TFIFO pin is set “1” when Transmit FIFO is Full (contains 32 words).
1
TFIFO pin is set “1” when Transmit FIFO is Half-Full (contains exactly 16 words).
4-0
-
R
0
Not used, Always reads “0”
TABLE 7.
12
C
11 C10
C
9
C
Read: SPI Op-code 0xF2
Write: SPI Op-code 0x72
8
C
7 C6 C5
C
X X X X X X X X
15 14 13 12 11 10 9
MSB
8
C
4
C
3 C2
C
1
WORD COUNT UTILITY REGISTER: WRDCNT
Y
PT
M
E
0
O
C FF S1 S
X X X X X X X X
7
6
5
4
3
2
1
0
LSB
The Word Count Utility Register can be programmed to generate an interrupt on the MATCH pin when the data for the specified word
count of the specified subframe is loaded into the Receive FIFO. The Word Count Utility Register can used with any of the standard
ARINC 717 data rates and all of the expanded data rates, except 8192 wps.
Bit
Name
R/W Default Description
15 - 3
C12:0
R/W
0
Subframe Word Count - The value is compared to the current word count in the Receive FIFO and
sets the MATCH pin to “1” whenever there is a match. The MATCH pin will stay at “1” for one word
time.
2
-
R/W
0
Not used, Always reads “0”
1-0
S1:0
R/W
0
Subframe ID
00
Subframe One
01
Subframe Two
10
Subframe Three
11
Subframe Four
TABLE 8.
HOLT INTEGRATED CIRCUITS
10
HI-3717A
ARINC 717 MESSAGE AND BIT ORDERING
The first 12- bit word of a subframe that appears on the ARINC 717
bus is the synchronization code with the least significant bit (LSB)
first. This is immediately followed by up to 8191 12-bit data words,
all within1 second from the start of the synchronization code. The
next three subframes immediately follow the first subframe with
their synchronization code as the first 12-bit word of the subframe
followed by the same number of data words as the first subframe.
ARINC 717 messages consist of 12-bit words sent in a 4 second
frame divided into four 1 second subframes. Each subframe
consists of 64 (basic rate), 128, 256, 512, 1024, 2048, 4096 or
8192 12 bit words, depending on the data rate of the target
system.
ARINC 717 data is transmitted between the HI-3717A and host
microcontroller using the four-wire Serial Peripheral Interface
(SPI). A read or write operation consists of a single-byte op-code
followed by 8-bit data words. Figure 5 shows examples of how the
SPI data bytes are mapped to the ARINC 717 message.
The first word of each subframe contains a unique Barker Code
synchronization pattern that identifies the subframe. The octal
synchronization code for subframes 1 through 4 are 1107, 2507,
5107 and 6670 respectively.
ARINC717 Message as received / transmitted on the ARINC 717 serial bus
Frame
Subframe 1
Subframe 2
MSB LSB
LSB
1 Second
Subframe 3
MSB LSB
Subframe 4
MSB
MSB
LSB
1 Second
1 Second
1 Second
4 Seconds
ARINC717 Subframe Format
Nth Data Word
1st Subframe Sync Code (1107)
2nd Data Word
1 1 1 0 0 0 1 0 0 1 0 0
0 1 2 3 4 5 6 7 8 9 10 11
0 1 2 3 4 5 6 7 8 9 10 11
MSB
MSB LSB
LSB
MSB
LSB
1 Second
time
ARINC 717 Message as transferred on the SPI bus
SPI Op-Code
Don’t Care
0 1 1 1 0 1 0 0
LSB
MSB
Subframe Sync or Data Word Bits
7 6 5 4 3 2 1 0
X X X X 11 10 9 8
LSB
MSB
Example 1. Write Transmit FIFO Subframe Sync or Data Word (Op-Code 0x74).
SPI Op-Code
Always “0”
1 1 1 0 0 1 1 0
LSB
MSB
Subframe Sync or Data Word Bits
0 0 0 0 11 10 9 8
7 6 5 4 3 2 1 0
LSB
MSB
Example 2. Read Receive FIFO Subframe Sync or Data Word (Op-Code 0xF6).
SPI Op-Code Subframe Sync or Data Word Bits
0 0 1 0 11 10 9 8
7 6 5 4 3 2 1 0
LSB
MSB
Example 3. Fast Write Transmit FIFO Subframe Sync or Data Word (Op-Code 0x2-) .
SPI Op-Code
Word Count Bits
0 1 1 1 0 0 1 0
LSB
MSB
12 11 10 9 8 7 6 5
Sync Bits
4 3 2 1 0 X 1 0
LSB
MSB
Example 4. Write Word Count Utility Register, WRDCNT (Op-Code 0x72).
SPI Op-Code
Always “0”
1 1 1 1 1 1 1 0
MSB
LSB
Subframe Sync or Data Word Bits
0 0 0 0 11 10 9 8
Word Count Bits
7 6 5 4 3 2 1 0
LSB
MSB
12 11 10 9 8 7 6 5
4 3 2 1 0 0 1 0
LSB
MSB
Example 5. Read Receive FIFO Data Word with Word Count (Op-Code 0xFE).
FIGURE 5.
Sync Bits
ARINC 717 & SPI Bit Ordering
HOLT INTEGRATED CIRCUITS
11
Always “0”
HI-3717A
FUNCTIONAL DESCRIPTION
OVERVIEW
ARINC 717 is a continuous transmission of 12-bit words in 4 second
frames divided into four 1 second subframes. The programmed
data rate (32 to 8192 wps) determines the number of words per
subframe. The first word of each subframe is reserved for a unique
sync mark. Figure 5 illustrates the relationship between ARINC 717
frames, subframes and words.
The HI-3717A is comprised of independent ARINC 717 receive and
transmit sections easily accessible via a four wire SPI
communications bus. It supports the ARINC 717 Harvard Bi-Phase
(HBP) protocol as well as the Bi-Polar Return to Zero (BPRZ)
auxiliary protocol.
The receiver accepts data from either a Harvard Bi-Phase (HBP) or
a Bi-Polar Return to Zero (BPRZ) bus, recovers the clock, decodes
the data, synchronizes the ARINC 717 data frames using the
unique subframe sync marks and stores the recovered data in a 32
word x 12 bit Receive FIFO.
The ARINC 717 Transmitter accesses data from a 32 word x 12 bit
Transmit FIFO, encodes it into both HBP and BPRZ data streams at
the selected data rate, and converts the digital data stream to
ARINC 717 bus compatible outputs. There are separate outputs for
the HBP and BPRZ ARINC 717 buses.
In order to avoid inadvertent transceiver operation, Control
Register 0, CTRL0, should be programmed last. Writing
CTRL0 sets the desired data rate which, after one bit period,
enables the internal clocks. This in turn makes the transmitter
or receiver operational. Changing the data rate on the fly may
result in unpredictable operation during the transition to the
new programmed state. A full reset, POR or MR, should be
issued before reprogramming the data rate.
Data Rate
For correct ARINC 717 date rate reception, transmission and bit
timing, the HI-3717A requires a 24 MHz reference clock source
applied to the ACLK input. This clock is divided down to achieve the
data rate programmed with CTRL0<6:4>. The input receive data is
8X oversampled relative to the programmed data rate.
ARINC 717 requires a basic data rate of 64 wps with support for
128, 256 and 512 wps. The HI-3717A offers an expanded range of
32 to 8192 wps for testing purposes and future expansion.
CTRL0<3>, 32WPS, overrides the state of CTRL0<6:4> and sets
the data rate to 32 wps. The required 0.1% timing tolerance is
maintained over all data rates.
Line Driver Output Slew Rates
Refer to Figure 1 for the Block Diagram of the HI-3717A
The slew rate of the HBP and BPRZ outputs is controllable with
CTRL0<2:1>. A 3.75μs slew rate conforms to all the required
ARINC 717 data rates. A 1.5μs is provided for higher data rates
beyond the standard. In addition, slower slew rates of 7.5μs and
10μs are available to further optimize the application.
INITIALIZATION AND RESET
Receiver Format
The HI-3717A generates a full reset upon application power. The
power-on-reset (POR) sets all registers to their default values,
places the Receive and Transmit FIFOs to their empty state, and
clears the sync detection logic. It also sets both the HBP and BPRZ
outputs to the high impedance state and the input sampling and
decoders are disabled. See Register Descriptions for complete
definition of the default values.
The ARINC 717 format of the receiver is selectable as HBP or
BPRZ by the state in CTRL0<0>, RXSEL, OR’d with the state of the
external RSEL input pin. A “0” on RSEL and CTRL0<0> selects
HBP and a “1” on either RSEL or CTRL0<0> selects BPRZ.
The part can also be initialized to the full reset state by applying a
100ns active low pulse to the external MR pin.
Input Synchronization Mode
A software reset is also possible via the SPI communications
interface by writing a “1” to the CTRL1<3>. This bit places both the
Receive and Transmit FIFO’s in the empty state, clears the sync
detection logic, and sets both the HBP and BPRZ line drivers to a
high impedance state. All other registers remain unchanged. The
device is held in the reset state until a “0” is written to CTRL1<3>.
1. 4 Sync-Word Mode
The receive and transmit sections operate at the same data rate
and they are configured and monitored via the SPI interface.
Refer to Table 3 for the detail description of each bit in Control
Register 0.
The HI-3717A has three different synchronization modes:
This is the default synchronization mode at power up or after a
Master Reset. In this mode the HI-3717A searches for the four
subframe sync marks:
SYNC1 = Octal 1107
SYNC2 = Octal 2670
SYNC3 = Octal 5107
SYNC4 = Octal 6670
CONFIGURATION
The HI-3717A is configured via the SPI communications bus by
writing to Control Register 0, CTRL0, and Control Register 1,
CTRL1. They are reset to 0x00 following a Power On Reset
(POR) or a Master Reset (MR) but remain unchanged on a
Software Reset, CTRL1<3>, SRST. The function of each register
bit is shown in the Register Descriptions.
in the correct sequential order starting from SYNC1 and the
exact bit time determined by the programmed word rate. When
synchronization is achieved the INSYNC pin as well as the
INSYNC bit of the Receive FIFO Status Register, RXFSTAT<7>
are set to “1” on the next valid SYNC1 mark. The valid SYNC1
mark and following data words are stored in the Receive FIFO.
HOLT INTEGRATED CIRCUITS
12
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
Sync time varies from 4 seconds to a worst case of 8 seconds
for a valid data stream.
The first word stored in the Receive FIFO is available when
RXFSTAT<2>, RFEMPTY, is reset to “0”, which is 12-bit periods
(one word time) after INSYNC is set to “1”.
The HI-3717A remains in sync as long as the proper sync
sequence is maintained. INSYNC is reset to “0” when the next
expected subframe sync mark is not present. The HI-3717A will
initiate a new synchronization process at the next valid SYNC1
mark.
Once the part falls out of sync, the whole previous subframe
should be discarded.
NOTE: If the part does not synchronize in 8 seconds
(INSYNC = “0”), a Software Reset should be performed by
setting CTRL1<3>, SRST.
2. 2 Sync-Word Mode
In this mode the HI-3717A searches for any two subframe sync
marks in the correct sequential order and the exact starting time
for the sync mark. INSYNC is set to “1” when the third valid sync
mark is detected. The part must continue to detect each sync
mark in the correct order and with the correct starting time to
stay in sync.
This method reduces the time required to obtain sync to about 2
seconds typical and a worst case of 3 seconds.
3. No Sync Detect Mode
Digital Loopback
Normal HI-3717A operation is with CTRL1<0> set to “0”. Setting it
to “1” places the part in digital loopback mode. In this mode the
analog line receivers are disconnected from the data samplers
and both output line drivers are placed in a high impedance state.
The output encoders are connected to input sampler / decoder.
The part may be verified by selecting the desired receive decode
format with RSEL pin or CTRL0<0>, writing the transmit FIFO and
reading the receive FIFO. All status pins and registers reflect the
status of the loopback operation.
FIFO Status Pin Assignment Register, FSPIN
This register assigns the function of the external RFIFO and
TFIFO pins. The RFIFO pin reflects the state of one of the three
Receive FIFO status flags (RFFULL, RFHALF and RFEMPTY) in
the Receive FIFO Status Register, RXFSTAT. The TFIFO pin
reflects the state of one of two Transmit FIFO states (Transmit
FIFO Full or Transmit FIFO Half-Full). Refer to the FSPIN Register
Description in Table 7 for register assignment details.
Word Count Utility Register, WRDCNT
The MATCH pin goes high when the HI-3717A is in the INSYNC
condition and the word count and subframe count matches the
value programmed in the Word Count Utility Register. Note: The
INSYNC pin is set to “1” when the second consecutive SYNC1
mark of the proper sync sequence is received. The Word Count
Utility Register and Match pin function can be used for the
standard ARINC 717 data rates and all of the expanded data rates,
except 8192 wps.
In this mode, the INSYNC is set to “1” and all data is stored in
the Receive FIFO. Without sync detection, the Receive FIFO
just records the sequential bits, not words, from the bus. It is up
to the user to detect the sync marks and determine the word
boundaries in this mode.
In both the 4 Sync-Word and 2 Sync-Word Modes, the HI-3717A
uses a proprietary sync tracking and detection method which allows
correct synchronization to occur in the presence of up to three false
sync marks without increasing the sync time.
+5V
Harvard Bi-Phase
-5V
+10V
Bi-Polar Return to Zero
-10V
Data
1
0
1
1
0
1
0
1
0
LSB
FIGURE 6.
0
1
1
MSB
ARINC 717 HBP & BPRZ Differential Input Signal Format
HOLT INTEGRATED CIRCUITS
13
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
ARINC 717 RECEIVER
The input data stream for ARINC 717 can be one of two formats.
The main ARINC 717 bus to a Digital Flight Data Recorder (DFDR)
uses Harvard Bi-phase (HBP) encoding and the auxiliary output
bus to an Aircraft Integrated Data System (AIDS) uses Bi-Polar
Return to Zero (BPRZ) encoding as shown in Figure 6.
The HI-3717A has an independent ARINC 717 receive channel with
a selectable on-chip HBP analog line receiver for connection to the
main incoming ARINC 717 data bus or a BPRZ analog line receiver
for connection to an auxiliary data bus.
The ARINC 717 specification requires the following detection levels
for the HBP inputs:
STATE
HI
NULL
LO
The auxiliary BPRZ input detection levels are the same as
standard ARINC 429 levels:
DIFFERENTIAL VOLTAGE
+6.5 Volts to +13 Volts
+2.5 Volts to -2.5 Volts
-6.5 Volts to -13 Volts
The HI-3717A guarantees recognition of these levels with a
common mode voltage with respect to GND less than ±25V for the
worst case conditions (3.15V supply, 8V HBP signal level and 13V
BPRZ signal level).
Design tolerances guarantee detection of the above levels, so the
actual acceptance ranges are slightly larger. If the signal (including
nulls) is outside the differential voltage ranges, the HI-3717A
receiver rejects the data.
RINA-40
VDD
DIFFERENTIAL
AMPLIFIERS
The bit timing for both the receive and transmit functions is the data
rate programmed in CTRL0<6:3>. The HI-3717A allows the
following word / bit rates:
32 words/sec.
64 words /sec.
128 words/sec.
256 words/sec.
512 words /sec.
1024 words/sec.
2048 words/sec.
4096 words/sec.
8192 words/sec.
The sampler uses three separate shift registers, one each for
Ones, Zero and Null detection. When the input signal is within the
differential voltage range of one of the valid states (One, Zero or
Null) of the selected data format, the sampler clocks “1” into that
register and a “0” into the other two. When the signal is outside the
differential voltage ranges defined for all the shift registers, a “0” is
clocked into all three registers. Only one shift register can clock “1”
for a given sample. The Null shift register is only used for the BPNZ
format.
For Havard Bi-phase, HBP, coding, the sampler validates a HI
(One) or LO (Zero) if the signal is in that state for at least two
samples. There is no Null state for the HBP format.
The Bi-Polar Return to Zero, BPRZ, coding sampler validates that
at least two consecutive Ones or two consecutive Zeroes are
followed by at least two consecutive Null states.
ONE
NULL
GND
384 Bits/sec
768 Bits/sec.
1536 Bits/sec.
3072 Bits/sec.
6144 Bits/sec.
12288 Bits/sec.
24576 Bits/sec.
49152 Bits/sec.
98304 Bits/sec.
The 32 WPS data rate is typically used for testing purposes.
COMPARATORS
RINA
=
=
=
=
=
=
=
=
=
The input data from the selected analog line receiver is
oversampled at 8X relative to the word rate programmed in
CTRL0<6:3>. This is 4X oversample of the transition rate since the
code rate for both methods is double the data rate.
DIFFERENTIAL VOLTAGE
+2 Volts to +8 Volts
NA
-2 Volts to -8 Volts
STATE
ONE
NULL
ZERO
Bit Timing & Input Sampling
VDD
ZERO
RINB
RINB-40
GND
CNTL0<0>
RSEL
FIGURE 7. ARINC 717 Receiver Inputs
HOLT INTEGRATED CIRCUITS
14
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
Decoders
The decoder recovers the clock and resynchronizes each valid one
or zero to the transition bit period.
The Harvard Bi-phase, HBP, decoder confirms the sampler only
provided a valid One or Zero, not both, then detects the presence or
absence of an edge in the data bit period. The output of the decoder
is a “1” if there was a transition, otherwise a “0”.
The Bi-Polar Return to Zero, BPRZ, decoder confirms the sampler
only provided a valid One or Zero, followed by a valid Null. The
decoder output is a “1” for a valid One and “0” for a valid Zero.
Once the data is captured, it is re-sampled to the recovered
transition rate clock (sample clock sent to the sync detector) and resampled to recover the data bit rate clock.
The decoders will operate correctly when the input data bit period is
not more than 2 sample clocks (25%) larger or 1 sample clock
(12.5%) smaller than the nominal value. The slower input frequency
causes a mismatch between the sampled data and the recovered
clock. The faster input frequency causes issues with internal edge
detection logic.
SYNC Detect
In the 2 Sync-Word Mode, CTRL1<2> = “1”, once two consecutive
valid subframe sync marks are detected, the INSYNC bit is set to “1”
at the next consecutive valid subframe sync mark if it occurs at the
proper relationship to the previous valid sync marks. The first valid
subframe sync mark does not have to be SYNC1 in this mode but
each successive subframe sync marks must be the next in the
sequence and properly spaced from the preceding valid subframe
sync mark.
INSYNC is set to “0” when the next expected subframe sync mark is
missed in the 4 Sync-Word or 2 Sync-Word Modes. The HI-3717A
sync detection logic is reset and the part initiates the full synchronization process again. The data from the subframe preceding the
first incorrect subframe sync mark should be discarded. No data is
passed to the Receive FIFO until synchronization is reestablished.
There are also two bits in the Receive FIFO Status Register,
RXFSTAT<6:5> that provide a realtime indicator when each of the
four ARINC 717 subframe sync marks are received. The bits are
valid only when INSYNC is “1” and are updated when the subframe
sync word is loaded into the Receive FIFO.
The final mode is No Synchronization, CRTL1<1> = “1”. In this
mode data is captured and loaded directly to the Receive FIFO in
the order it was received. It is the responsibility of the user to extract
the data from the FIFO and determine word, frame and subframe
boundaries. The INSYNC bit remains “0” while in this mode.
Receive FIFO and Retrieving Data
The HI-3717A employs a proprietary, four level sync algorithm that
samples each bit and compares each combination of 12-bits
against the four valid ARINC 717 subframe sync marks.
In 4 Sync-Word Mode, once a valid SYNC1 mark is discovered, it
continues to look for each of the next three subframe sync marks in
the proper order and timing. If any one is not found, the search
starts over looking for SYNC1 again. Once all four sync marks are
detected in the proper order and location in a frame, the INSYNC
pin is set to “1” at the next SYNC1 subframe sync mark if it is the
correct value and it occurs at the proper relationship to the previous
valid sync mark. This is the default synchronization mode for the
HI-3717A.
Data is transferred from the Receive FIFO starting with the valid
subframe sync mark when INSYNC was set to “1” and continues
with each consecutive 12-bit word until INSYNC is set to “0”.
Each time a valid ARINC 717 word is loaded to the Receive FIFO the
RFFULL, RFHALF and RFEMPTY bits in the Receive FIFO Status
Register (RXFSTAT<4:2>) are updated. Each word is retrieved
from the Receive FIFO via the SPI interface using SPI Op-code
instruction 0xF6 (word only), 0xFE (word & word count) or 0xC
(Fast Read).
SYNC DETECTION
ONES
SHIFT REGISTER
INSYNC
HBP
DECODER
HBP / BPRZ
SELECT
NULL
12-BIT SERIAL
INPUT REGISTER
12-BIT SERIAL
REGISTER
SHIFT REGISTER
12-BIT COMPARATOR
32 WORD x 12-BIT
RECEIVE FIFO
ZEROS
ACLK
SHIFT REGISTER
DATA CLOCK
DIVIDER
BPRZ
DECODER
WORD
WORD COUNT CLOCK
&
SUBFRAME
DETECTION
CTRL0<0>
CTRL0<6:4>
RSEL
FIGURE 8.
ARINC 717 Receiver Block Diagram
HOLT INTEGRATED CIRCUITS
15
12-BIT SERIAL
INPUT REGISTER
to Line Drivers
RFIFO
ROVF
SYNC0
SYNC1
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
The SPI read instruction 0xF6 format is an 8-bit op-code followed by
two 8-bit data words. The four most significant bits (MSB) of the first
data word are always “0” followed by the first four MSB of the ARINC
717 word. The second data word contains the remaining 8-bits of
the ARINC 717 word. The least significant bit (LSB) of the ARINC
717 word is the LSB of the second 8-bit data word.
The format for read word and word count instruction 0xFE is the
same as the read instruction with the addition of two additional 8-bit
data bytes that contain the word count and the corresponding sync
subframe information. The third 8-bit SPI data byte contains the 8
MSB bits of the word count. The fourth data byte is comprised of
remaining 5 bits of the word count as well as the two bit code for the
subframe number in the same format as described in the RFXSTAT
Register Description. Refer to Example 5 in Figure 5 for more
details on the format for this instruction.
The Fast Read instruction 0xC uses only one SPI data byte for a
read operation. This is accomplished by using only first four bits for
the SPI op-code and placing the first four most significant bits of the
ARINC 717 word in the four remaining bit locations of what are
normally part of an op-code. The remaining 8-bits of the ARINC 717
word are in a normal SPI data byte. This method use one less SPI
data byte than a normal read instruction.
Up to 32 ARINC 717 words may be held in the Receive FIFO. The
RFFULL bit (RXFSTAT<4>) is set to “1” when the Receive FIFO is
full. Failure to unload the Receive FIFO when full will result in loss
of new data words until there are less than 32 words in the FIFO.
The RFOVF bit (RXFSTAT<1>) and external FROV pin are set to “1”
when an attempt is made to write to a full Receive FIFO.
The Receive FIFO half-full flag, the RFHALF bit (RXFSTAT<3), is
set to “1” whenever the Receive FIFO contains exactly 16 words.
The RFHALF bit provides a useful indicator to the host CPU that the
FIFO is filling up.
The Receive FIFO empty, the RFEMPTY bit (RXFSTAT<2>), is set
to “1” when the Receive FIFO is empty. It is reset to “0” when there
is at least one word in the Receive FIFO.
When the HI-3717A attempts to load a valid word to a full Receive
FIF0, the RFOVF flag, RXFSTAT<1>, and the external RFOV pin
are set to “1”. The Receive FIFO ignores any attempt to load any
additional words if it is full. The RFOVF flag and RFOV pin are reset
to “0” when either the INSYNC goes to “0” or the device is reset.
The external RFIFO pin is programmable in the FIFO Status Pin
Assignment Register (FSPIN<7:6>) to reflect the value of the
RFFULL, RFHALF or the RFEMPTY status bit. Refer to the FSPIN
Register Description for the bit values that assign the RFFULL,
RFHALF or RFEMPTY status bit to the RFIFO pin. The default
state is assignment of the RFEMPTY bit to the RFIFO pin.
Word Count Utility Register, WRDCNT, is used to cause the
external MATCH pin to be set to”1” when a specific word count is
reached in a specific subframe. WRDCNT<15:3> specifies the
location in the subframe and WRDCNT<1:0> specifies the
subframe that is monitored. MATCH is “1” until the next word is
loaded into the Receive FIFO.
The Match word and subframe bit assignments of the Word Count
Utility Register, WRDCNT, are found in Table 8.
TXHA
TXHB
HBP
ENCODER
12 BIT PARALLEL
LOAD SHIFT REGISTER
BPRZ
ENCODER
HBP
LINE DRIVER
SLEW RATE
&
LOOPBACK
TEST
CONTROL
TXOUTHA, OUTHA
TXOUTHB, OUTHB
NOCONV
BPRZ
LINE DRIVER
TXOUTBA, OUTBA
TXOUTBB, OUTBB
TXBA
TXBB
BIT CLOCK
WORD CLOCK
&
BIT CLOCK
WORD CLOCK
START
SEQUENCE
32 word x 12 bit FIFO
ADDRESS
WORD COUNTER
&
FIFO CONTROL
LOAD
TFIFO
TEMPTY
INCREMENT
WORD COUNT
FIFO
LOADING
SEQUENCER
SCK
SPI COMMANDS
CS
SI
SPI INTERFACE
SPI COMMANDS
DATA
CLOCK
SO
CTRL0<6:4>
FIGURE 9.
DATA CLOCK
DIVIDER
ARINC 717 Transmitter Block Diagram
HOLT INTEGRATED CIRCUITS
16
ACLK
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
TRANSMITTER
SYSTEM OPERATION
The receiver and transmitter always operate at the same data rate.
Otherwise, they operate completely independent of each other.
The only restrictions are:
FIFO Operation
The HI-3717A Transmit FIFO is loaded with ARINC 717 words
awaiting transmission. SPI words are written to the next Transmit
FIFO location with op-code 0x74 or 0x2 (Fast Write). If Transmit
FIFO Status Register empty flag, the TFEMPTY (TXFSTAT<5>)
bit, is “1” (FIFO empty), then up to 32 ARINC 717 12-bit words can
be safely loaded via the SPI interface. If the TFEMPTY bit is “0”
then less than 32 positions are available. If all 32 positions are
filled, then the Transmit FIFO is full. Any further attempt to load the
Transmit FIFO is ignored until the FIFO contains less than 32
words.
The Transmit FIFO half-full flag, the TFHALF (TXFSTAT<6>) bit in
the Transmit FIFO Status Register, is equal to “0” when there are
less than or more than 16 ARINC 717 words in the Transmit FIFO
and equal to “1” when there are exactly 16 words in the FIFO. The
host CPU can safely load 16 ARINC 717 words into the Transmit
FIFO only when TFHALF is “1”.
The Transmit FIFO status (Full or Empty) is available on the
external TFIFO pin, depending on the value in FSPIN<5> of the
FIFO Status Pin Assignment Register (See Table 7). The state of
the TFIFO pin is reflected in bit TFIFO in TXFSTAT<7>. The state
of TFEMPTY flag is always on the external TEMPTY pin.
It is the user’s responsibility to load the correct subframe sync
mark in the first word of each subframe and ensure the Transmit
FIFO is not left empty for more than one word time for continuous
transmissions.
The SPI format for writing an ARINC 717 word and Fast Word to
the HI-3717A Transmit FIFO is the same as the read format,
except the most significant bit of the op-code instruction is “0”
rather than a “1”.
Data Transmission
The ARINC 717 transmission begins when the first word is loaded
into the Transmit FIFO. Each word is serially fed to both the HBP
and BPRZ encoders at the data rate programmed in Control
Register 0, CNTL0<6:4>. The output of each encoder drives its
own ARINC 717 analog line driver. The slew rate of both the HBP
and the BPRZ auxiliary outputs is controllable with CNTL0<2:1>.
Refer to the CTRL0 Register Description for the individual bit
values required for setting the desired data and output slew rate.
1. The Receive FIFO ignores any attempt to load any additional
words if it is full and at least one location is not retrieved
before the next valid ARINC 717 is received.
2. The Transmit FIFO can store a maximum of 32 words and
ignores any attempt to store additional words when it is full.
DC/DC Converter
The HI-3717A requires only a single +3.3V power supply. An
integrated inverting / non-inverting voltage doubler generates the
rail voltages (±5.7V) which then power the line drivers to produce
the required +5V ARINC 717 HBP and ±5V ARINC 717 BPRZ
signal levels.
The internal dual-polarity charge pump requires four external
capacitors, two for each polarity generated by the charge pump.
Pins C1+ and C1- connect the external “fly” capacitor, CFLY, to the
positive portion of the charge pump, resulting in 5.7V at the V+ pin
that is generated by an on-board bandgap reference voltage. An
output “hold” capacitor, COUT, is placed between V+ and GND.
The inverting negative portion of the converter works in a similar
fashion, with CFLY and COUT placed between C2+ / C2- and V- /
GND respectively (see block diagram page 2). See Converter
Characteristics table for recommended capacitor specifications.
Line Driver Operation
The line drivers in the HI-3717A directly drive the ARINC 717
buses. The two ARINC 717 HBP outputs (TXOUTHA and
TXOUTHB) provide a differential voltage of ±5V in accordance
with the Harvard Bi-Phase format. Control Register 0
(CTRL0<6:4) controls the transmitter data rate and CTRL0<2:1>
controls the output slew rate.
The two auxillary ARINC 717 BPRZ outputs (TXOUTBA and
TXOUTBB) provide a differential voltage to produce a +10V One,
a -10V Zero, and a 0 Volt Null. The transmitter data rate is the
same as the HBP output which is also controlled by the same bits
in Control Register 0 (CTRL0<6:4). The slew rate of the differential output signal is also controlled by Control Register 0
(CTRL0<2:1>. No additional hardware is required to control the
slope. Slope rate is set by on-chip resistors and capacitors.
HOLT INTEGRATED CIRCUITS
17
HI-3717A
FUNCTIONAL DESCRIPTION (cont.)
Line Driver Output Pins
The Harvard Bi-phase (HBP) TXOUTHA and TXOUTHB pins as
well as the Bi-Polar Return to Zero (BPRZ) TXOUTBA and
TXOUTBB pins have 37.5 Ohms in series with each line driver
output, and may be directly connected to an ARINC 717 bus.
The OUTHA, OUTHB, OUTBA and OUTBB pins have 5 Ohms of
internal series resistance and require an external 32.5 ohm
resistor in series with each pin. OUTHA, OUTHB, OUTBA and
OUTBB pins are for applications where external series resistance is applied, typically for lightning protection devices.
Either the TXOUTHA & TXOUTHB outputs or the OUTHA &
OUTHB outputs are used in an application but not both sets at
the same time. Likewise, only one set of the auxiliary BPRZ
output pins (TXOUTBA & TXOUTBB or OUTBA & OUTBB) are
used. Using both set of pins on either output will produce
unpredictable results.
The line driver outputs TXOUTHA, TXOUTHB, OUTHA, OUTHB,
TXOUTBA, TXOUTBB, OUTBA & OUTBB are in a high impedance state after any reset and when in the digital loopback test
mode (CTRL1<0> = “1”) allowing multiple line drivers to be
connected to a single ARINC 717 bus. Note that both analog line
receivers are also disconnected from the HBP and BPRZ input
data samplers during reset and when in the digital loopback
mode.
The HI-3717A also has digital outputs from both the HBP (TXHA
& TXHB) and the BPRZ (TXBA & TXBB) encoders allowing the
use of external ARINC 717 line drivers. All four of these output
pins are active all the time and reflect the digital data sent to the
data sampler in the digital loopback mode.
By keeping excessive voltage outside the device, the RINA/B-40
input option is helpful in applications where lightning protection is
required.
Please refer to the Holt AN-300 Application Note for additional information and recommendations on lightning protection of Holt
line drivers and line receivers.
Master Reset
Application of a Master Reset with a 100ns active low pulse to the
external MR pin sets all registers to their default values, places
the Receive and Transmit FIFOs to their empty state, and clears
the sync detection logic. It also sets both the HBP and BPRZ outputs to the high impedance state and disables input sampling of
both analog line receivers..
Software Reset
A software reset is also possible via the SPI communications interface by writing a “1” to the CTRL1<3>. This bit places both the
Receive and Transmit FIFO’s in the empty state, clears the sync
detection logic, sets both the HBP and BPRZ line drivers to a high
impedance state and disables the input sampling of both analog
line receivers. Unlike POR and MR, ALL other registers remain
unchanged. The device is held in the reset state until a “0” is written to CTRL1<3>.
No DC/DC Converter Option
The NOCONV pin is set to “1” to disable the internal DC/DC Converter and supply +5V & -5V to the V+ & V- pins respectively from
an external power source. The “fly” capacitor pins can be left
floating.
Line Receiver Input Pins
No Internal Line Drive Option
The HI-3717A has two sets of Line Receiver input pins that are
shared with the HBP and BPRZ line receivers, RINA/B and
RINA/B-40. Only one pair may be used to connect to the ARINC
717 bus. The unused pair must be left floating. The RINA/B pins
may be connected directly to the ARINC 717 bus.
The HI-3717A can be used without the internal line drivers if only
the ARINC 717 receive function is required or if the user wants to
use his own external ARINC 717 line drivers connected to the
TXHA, TXHB, TXBA & TXBB digital transmitter outputs. For this
option, NOCONV pin is set to “1” to disable the internal line drivers, V+ is connected to VDD & V- is left unconnected.
The RINA/B-40 pins require an external 40K ohm resistor in series with each ARINC 717 input. The resistors do not affect the
ARINC 717 receiver level detection thresholds .
When using the RINA/B-40 pins, each side of the ARINC 717
bus must be connected through a 40K ohm series resistor in order for the chip to detect the correct ARINC 717 levels. The typical ARINC 717 differential signal is translated and input to a window comparator and latch. The comparator levels are set so
that with the external 40K ohm resistors, they are just below the
standard minimum data threshold and in the case of the auxiliary BPRZ line receiver, just above the standard 2.5 volt BPRZ
(ARINC 429) null threshold.
HOLT INTEGRATED CIRCUITS
18
HI-3717A
TIMING DIAGRAMS
t CPH
t CYC
CS
tCHH
t SCKF
t CES
SCK
t CEH
t CES
t DS
t SCKR
t DH
SI
MSB
LSB
FIGURE 10. SPI Serial Input Timing
t CPH
CS
t CYC
t SCKH
t SCKL
SCK
t CHZ
t DV
SO
MSB
Hi Impedance
LSB
Hi Impedance
FIGURE 11. SPI Serial Output Timing
HBP DATA
BPRZ DATA
INSYNC
12 Data Bits
tREMPTY
RFIFO (RFEMPTY)
RFIFO (RFFULL)
12 Data Bits
ROVF
tROVF
FIGURE 12. Receive FIFO Flag Timing
2nd to
LAST WORD
Bit 10
Bit 11
LAST TRANSMIT FIFO WORD
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
HBP DATA
BPRZ DATA
tTEMPTY
TEMPTY
FIGURE 13. Transmit FIFO Empty Flag Timing
HOLT INTEGRATED CIRCUITS
19
Bit 8
Bit 9
Bit 10
Bit 11
HI-3717A
TIMING DIAGRAMS (cont.)
HBP BIT
Data Bit 0
HBP BIT
Data Bit 1
+5V
HBP BIT
Data Bit 11
+5V
+5V
TXOUTHA & OUTHA
0V
0V
+5V
+5V
TXOUTHB & OUTHB
0V
+5V
+5V
90%
10%
(TXOUTHA - TXOUTHB
&
OUTHA - OUTHB)
0V
trx
tfx
+5V
VDIFF
0V
0V
-5V
90%
-5V
10%
one level
zero level
FIGURE 14. Harvard Bi-Phase (HBP) Output Waveforms
BPRZ BIT
Data Bit 0
BPRZ BIT
Data Bit 1
BPRZ BIT
Data Bit 11
+5V
+5V
TXOUTBA & OUTBA
-5V
+5V
TXOUTBB & OUTBB
-5V
-5V
tfx
+10V
+10V
90%
VDIFF
tfx
10%
(TXOUTBA - TXOUTBB
&
OUTBA - OUTBB)
trx
trx
10%
one level
zero level
90%
null level
-10V
FIGURE 15. Bi-Polar Return to Zero (BPRZ) Output Waveforms
Data Bit 1
Data Bit 0
HARVARD BI-PHASE (HBP)
+3.3V
tHr
+3.3V
90%
10%
90%
10%
TXHA
tHf
TXHB
0V
+3.3V
+3.3V
0V
tBr
+3.3V
90%
10%
tBf
0V
0V
+3.3V
0V
one level
0V
+3.3V
90%
10%
TXBA
TXBB
+3.3V
0V
0V
BI-POLAR RETURN ZERO (BPRZ)
Data Bit 11
0V
0V
null level
zero level
FIGURE 16. Harvard Bi-Phase (HBP) & Bi-Polar Return to Zero (BPRZ) Logic Output Waveforms
HOLT INTEGRATED CIRCUITS
20
HI-3717A
ABSOLUTE MAXIMUM RATINGS
Supply Voltages VDD ......................................... -0.3V to +5.0V
V+ ......................................................... +7.0V
V- ......................................................... -7.0V
Power Dissipation at 25°C
Plastic Quad Flat Pack ............... 1.5 W, derate 10mW/°C
Voltage at pins RINxx-xx .................................. -120V to +120V
DC Current Drain per digital input pin ........................... ±10mA
Voltage at pins TXAOUT, TXBOUT, AMPA, AMPB ......... V- to V+
Storage Temperature Range ........................ -65°C to +150°C
Voltage at any other pin ...............................-0.3V to VDD +0.3V
Operating Temperature Range (Industrial): ..... -40°C to +85°C
(Hi-Temp): ..... -55°C to +125°C
Solder temperature (Reflow) ............................................. 260°C
NOTE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only.
Functional operation of the device at these or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
VDD = 3.3V, TA = Operating Temperature Range (unless otherwise specified).
LIMITS
PARAMETER
HARVARD BI-PHASE (HBP) INPUTS
CONDITIONS
SYMBOL
-
MIN
TYP
MAX
UNIT
Pins RINA, RINB, RINA-40 (with external 40KOhms), RINB-40 (with external 40KOhms)
HBP Differential Input Voltage: (RINA to RINB)
HI
LO
VIHH
VILH
HI
LO
HI
LO
VIHHA
VILHA
VIHHB
VILHB
Common mode voltages less than
±25V with respect to GND
2.0
-8.0
5.0
-5.0
8.0
-2.0.
V
V
3.5
-1.5
-1.5
3.5
5.0
0
0
5.0
6.5
+1.5
+1.5
6.5
V
V
V
V
HBP Input Voltage (Ref. to DFDAU Signal Ground)
RINA
RINB
BI-POLAR RETURN TO ZERO (BPRZ) INPUTS -
Pins RINA, RINB, RINA-40 (with external 40KOhms), RINB-40 (with external 40KOhms)
BPRZ Differential Input Voltage: (RINA to RINB)
ONE
ZERO
NULL
VIHB
VILB
VINUL
ONE
ZERO
ONE
RINB
ZERO
VIHBA
VILBA
VIHBB
VILBB
Common mode voltages less than
±25V with respect to GND
6.5
-13.0
-2.5
10.0
-10.0
0
13.0
-6.5
+2.5
V
V
V
3.25
-6.5
-6.5
3.25
5.0
-5.0
-5.0
5.0
6.5
-3.25
-3.25
6.5
V
V
V
V
140
140
100
-
KΩ
KΩ
KΩ
200
μA
μA
20
20
20
pF
pF
pF
20% VDD
V
V
BPRZ Input Voltage (Ref. to DFDAU Signal Ground)
RINA
HARVARD BI-PHASE (HBP) & BI-POLAR RETURN TO ZERO (BPRZ) INPUTS
Input Resistance:
Differential
To GND
To VDD
RI
RG
RH
-
Input Sink
Input Source
IIH
IIL
-450
Differential
To GND
To VDD
CI
CG
CH
Input Voltage HI
Input Voltage LO
VIH
VIL
Input Sink
Input Source
Pull-down Current (MR, SI, SCK, ACLK pins)
Pull-up current (CS pin)
IIH
IIL
IPD
IPU
Input Current:
Input Capacitance:
(Guaranteed but not tested)
(RINA to RINB)
LOGIC INPUTS
Input Voltage:
Input Current:
HOLT INTEGRATED CIRCUITS
21
80% VDD
1.5
-1.5
60
-60
μA
μA
μA
μA
HI-3717A
DC ELECTRICAL CHARACTERISTICS (cont.)
VDD = 3.3V, TA = Operating Temperature Range (unless otherwise specified).
LIMITS
PARAMETER
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNIT
HARVARD BI-PHASE (HBP) OUTPUTS - Pins TXOUTHA, TXOUTHB, (or OUTHA, OUTHB with external 32.5 Ohms)
HBP output voltage (Differential)
(TXOUTHA to TXOUTHB or OUTHA to OUTHB)
HI
LO
VOHH
VOLH
600 ohm load
4.0
-6.0
5.0
-5.0
6.0
-4.0
V
V
HI
LO
HI
LO
VOHHA
VOLHA
VOHHB
VOLHB
600 ohm load
4.5
-0.5
-0.5
4.5
5.0
0
0
5.0
5.5
+0.5
+0.5
5.5
V
V
V
V
HBP output voltage (Ref to GND)
TXOUTHA or OUTHA
TXOUTHB or OUTHB
BI-POLAR RETURN TO ZERO (BPRZ) OUTPUTS - Pins TXOUTBA, TXOUTBB, (or OUTBA, OUTBB with external 32.5 Ohms)
BPRZ output voltage (Differential)
(TXOUTBA to TXOUTBB or OUTBA to OUTBB)
ONE
ZERO
NULL
VOHB
VOLB
VONUL
No load
9.0
-11.0
-0.5
10.0
-10.0
0
11.0
-9.0
+0.5
V
V
V
ONE
ZERO
ONE
ZERO
VOHBA
VOLBA
VOHBB
VOLBB
No load
4.5
-5.5
-5.5
4.5
5.0
-5.0
-5.0
5.0
5.5
-4.5
-4.5
5.5
V
V
V
V
IOUT
Momentary short-circuit current
80
Logic "1" Output Voltage
Logic "0" Output Voltage
VOH
VOL
IOH = -100μA
IOL = 1.0mA
90%VDD
Output Sink
Output Source
IOL
IOH
VOUT = 0.4V
VOUT = VDD - 0.4V
1.6
BPRZ output voltage (Ref to GND)
TXOUTBA or OUTBA
TXOUTBB or OUTBB
HARVARD BI-PHASE (HBP) and BI-POLAR RETURN TO ZERO (BPRZ) OUTPUTS
Output current
mA
LOGIC OUTPUTS (Including TXHA, TXHB, TXBA & TXBB)
Output Voltage:
Output Current:
Output Capacitance:
CO
10% VDD
V
V
-1.0
mA
mA
15
pF
OPERATING VOLTAGE RANGE
VDD
3.15
3.45
V
35
mA
120
mA
OPERATING SUPPLY CURRENT
Transmitting Data at 8192 words/sec.
IDD
Transmitting Data in 8192 words/sec.
IDDL
Outputs Unloaded
600 Ohm Differential Output Load HBP
400 Ohm Differential Output Load BPRZ
HOLT INTEGRATED CIRCUITS
22
HI-3717A
AC ELECTRICAL CHARACTERISTICS
VDD = 3.3V, TA = Operating Temperature Range and ACLK=24MHz +0.1%
LIMITS
PARAMETER
SYMBOL
UNITS
MIN
TYP
MAX
SPI INTERFACE TIMING
SCK clock period
CS active after last SCK rising edge
CS setup time to first SCK rising edge
CS hold time after last SCK falling edge
CS inactive between SPI instructions
SPI SI Data set-up time to SCK rising edge
SPI SI Data hold time after SCK rising edge
SCK rise time
SCK fall ime
SCK pulse width high
SCK pulse width low
SO valid after SCK falling edge
SO high-impedance after CS inactive
MR pulse width
tCYC
tCHH
tCES
tCEH
tCPH
tDS
tDH
tSCKR
tSCKF
tSCKH
tSCKL
tDV
tCHZ
tMR
100
5
5
5
55
10
10
10
10
20
25
35
30
40
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
RECEIVER TIMING
Delay - INSYNC high to REMPTY low (plus 12 data bits)
Delay - RFFULL high to ROVF high (plus 12 data bits)
tREMPTY
tROVF
100
100
ns
ns
2604
1302
651
326
163
81.4
41.7
20.4
10.2
μs
μs
μs
μs
μs
μs
μs
μs
μs
10
10
5.0
5.0
15
15
2.0
2.0
μs
μs
μs
μs
μs
μs
μs
μs
5.0
5.0
5.0
5.0
ns
ns
ns
ns
TRANSMITTER TIMING
TFEMPY flag high to beginningt of first data bit of last word in Transmit FIFO
32 words / sec.
tTEMPTY (32 wps)
64 words / sec.
tTEMPTY (64 wps)
128 words / sec.
tTEMPTY (128 wps)
256 words / sec.
tTEMPTY (256 wps)
512 words / sec.
tTEMPTY (512 wps)
1024 words / sec.
tTEMPTY (1024 wps)
2048 words / sec.
tTEMPTY (2048 wps)
4094 words / sec.
tTEMPTY (4096 wps)
8192 words / sec.
tTEMPTY (8192 wps)
Line driver transition differential times (Both the Harvard Bi-Phase and Bi-Polar Return to Zero are set to the same slew rate)
CNTL0<2:1> = 00
high to low
tfx
5.0
7.5
low to high
trx
5.0
7.5
CNTL0<2:1> = 01
high to low
tfx
2.5
3.75
low to high
trx
2.5
3.75
CNTL0<2:1> = 10
high to low
tfx
5.0
10
low to high
trx
5.0
10
CNTL0<2:1> = 11
high to low
tfx
1.0
1.5
low to high
trx
1.0
1.5
Transmitter digital outputs transition times
Harvard Bi-Phase (HBP)
high to low
tHf
3.0
low to high
tHr
3.0
Bi-Polar Return to Zero (BPRZ)
high to low
tBf
3.0
low to high
tBr
3.0
HOLT INTEGRATED CIRCUITS
23
HI-3717A
CONVERTER CHARACTERISTICS
VDD = +3.3V, TA = Operating Temperature (unlesss otherwise stated)
LIMITS
PARAMETER
Start-up transient (V+, V-)
Operating Switching Frequency
Worst case maximum voltage doubler output
SYMBOL
TEST CONDITIONS
tSTART
fSW
VDD2+(max) VDD = 3.6V, T= -55C,
VDD2-(max)
Capacitor Requirements (see block diagram on p. 2 for capacitor placement)
V+ Fly-back capacitor, non-polarized
x7R MLCC, 10V minimum
CFLY+
ESR(CFLY+)
500 kHz
V- Fly-back capacitor, non-polarized
x7R MLCC, 10V minimum
CFLYESR(CFLY-)
500 kHz
Two bulk storage capacitors, non-polarized
X7R MLCC or tantalum, 10V minimum
COUT
ESR(COUT)
Supply de-coupling capacitors,
x7R MLCC or tantalum, 10V minimum
CSUPPLY
Open load
UNITS
MIN
TYP
MAX
-
650
10
6.93
-6.93
ms
kHz
V
V
0.47
-
500
μF
mW
2.2
-
500
μF
mW
10
-
47
300
μF
mW
10
0.1
47
μF
μF
500 kHz
Two parallel capacitors
HOLT INTEGRATED CIRCUITS
24
HI-3717A
HEAT SINK - CHIP-SCALE PACKAGE ONLY
The HI-3717APCx uses a 44-pin plastic chip-scale
package. This package has a metal heat sink pad on its
bottom surface. This heat sink is electrically isolated from
ORDERING INFORMATION
HI - 3717A xx x x
PART
NUMBER
Blank
F
PART
NUMBER
the die. To enhance thermal dissipation, the heat sink can
be soldered to matching circuit board pad.
LEAD
FINISH
Tin / Lead (Sn / Pb) Solder
100% Matte Tin (Pb-free, RoHS compliant)
TEMPERATURE
RANGE
FLOW
BURN
IN
I
-40°C TO +85°C
I
No
T
-55°C TO +125°C
T
No
M
-55°C TO +125°C
M
Yes
PART
NUMBER
PACKAGE
DESCRIPTION
PC
44 PIN PLASTIC CHIP-SCALE, QFN (44PCS)
PQ
44 PIN PLASTIC QUAD FLAT PACK, PQFP (44PMQS)
HOLT INTEGRATED CIRCUITS
25
HI-3717A
REVISION HISTORY
P/N
Rev
Date
DS3717B
NEW
A
03/12/15
05/4/15
B
08/31/15
Description of Change
Initial Release.
Clarify that CS must be asserted for every word read from the FIFO (cannot hold
CS low and read multiple words). Remove reference to ARINC 573 standard.
Eliminate “Flight” and “Test” mode nomenclature and rename to 4 Sync-Word
mode and 2 Sync-Word mode respectively. Both modes are equally valid to
achieve synchronization. Add note on p. 13 regarding synchronization. Update
SPI Serial Output Timing diagram. Correct numerous typos.
HOLT INTEGRATED CIRCUITS
26
HI-3717A PACKAGE DIMENSIONS
millimeters (inches)
44-PIN PLASTIC CHIP-SCALE PACKAGE (QFN)
Package Type: 44PCS
7.00
BSC
(0.276)
5.50 ± 0.050
(0.217 ± 0.002)
0.50 BSC
(0.0197)
7.00
BSC
(0.276)
5.50 ± 0.050
(0.217 ± 0.002)
Top View
Bottom
View
0.25 ± 0.050
(0.010 ± 0.002)
1.00
max
(0.039)
0.200 typ
(0.008)
0.400 ± 0.050
(0.016 ± 0.002)
Electrically isolated heat
sink pad on bottom of
package
Connect to any ground or
power plane for optimum
thermal dissipation
BSC = “Basic Spacing between Centers”
is theoretical true position dimension and
has no tolerance. (JEDEC Standard 95)
millimeters (inches)
44-PIN PLASTIC QUAD FLAT PACK (PQFP)
Package Type:
44PMQS
0.230 MAX.
(0.009)
0.80
BSC
(0.031)
10.000 BSC
(0.394
SQ.
13.200 BSC
(0.520)
SQ.
0.370 ± 0.080
(0.015 ± 0.003)
0.880 ± 0.150
(0.035 ± 0.006)
1.60
typ
(0.063)
0.20
min
(0.008)
See Detail A
2.70
MAX.
(0.106)
2.00 ± 0.20
(0.079 ± 0.008)
0.30
R MAX.
(0.012)
0.13
R MIN. Detail A
(0.005)
BSC = “Basic Spacing between Centers”
is theoretical true position dimension and
has no tolerance. (JEDEC Standard 95)
HOLT INTEGRATED CIRCUITS
27
0° £ Q £ 7°
Similar pages