IS42VM32400F 1M x 32Bits x 4Banks Mobile Synchronous DRAM Description These IS42VM32400F are mobile 134,217,728 bits CMOS Synchronous DRAM organized as 4 banks of 1,048,576 words x 32 bits. These products are offering fully synchronous operation and are referenced to a positive edge of the clock. All inputs and outputs are synchronized with the rising edge of the clock input. The data paths are internally pipelined to achieve high bandwidth. All input and output voltage levels are compatible with LVCMOS. Features JEDEC standard 1.8V power supply. • Auto refresh and self refresh. • All pins are compatible with LVCMOS interface. • All inputs and outputs referenced to the positive edge of the system clock. • Data mask function by DQM. • 4K refresh cycle y / 64ms. • Internal 4 banks operation operation. • Programmable Burst Length and Burst Type. • Burst Read Single Write operation. - 1, 2, 4, 8 or Full Page for Sequential Burst. - 4 or 8 for Interleave Burst. • Programmable CAS Latency : 2,3 clocks. • Programmable Driver Strength Control - Full Strength or 1/2, 1/4 of Full Strength • Special Function Support. - PASR(Partial Array Self Refresh) - Auto TCSR(Temperature Compensated Self Refresh) • Automatic precharge, includes CONCURRENT Auto Precharge Mode and controlled Precharge. • Deep Power Down Mode Mode. Copyright © 2010 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on any published information and before placing orders for products. Integrated Silicon S S Solution, Inc. does not recommend the use off any off its products in life f support applications where the failure f or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless Integrated Silicon Solution, Inc. receives written assurance to its satisfaction, that: a.) the risk of injury or damage has been minimized; b.) the user assume all such risks; and c.) potential liability of Integrated Silicon Solution, Inc is adequately protected under the circumstances Rev. A | July 2010 www.issi.com - [email protected] 1 IS42VM32400F Figure1: 90Ball FBGA Ball Assignment 1 2 3 4 5 6 7 8 9 A DQ26 DQ24 VSS VDD DQ23 DQ21 B DQ28 VDDQ VSSQ VDDQ VSSQ DQ19 C VSSQ DQ27 DQ25 DQ22 DQ20 VDDQ D VSSQ DQ29 DQ30 DQ17 DQ18 VDDQ E VDDQ DQ31 NC NC DQ16 VSSQ F VSS DQM3 A3 A2 DQM2 VDD G A4 A5 A6 A10 A0 A1 H A7 A8 NC NC BA1 A11 J CLK CKE A9 BA0 /CS /RAS K DQM1 NC NC /CAS /WE DQM0 L VDDQ DQ8 VSS VDD DQ7 VSSQ M VSSQ DQ10 DQ9 DQ6 DQ5 VDDQ N VSSQ DQ12 DQ14 DQ1 DQ3 VDDQ P DQ11 Q VDDQ Q VSSQ SSQ VDDQ VSSQ Q DQ4 Q R DQ13 DQ15 VSS VDD DQ0 DQ2 [Top View] Rev. A | July 2010 www.issi.com - [email protected] 2 IS42VM32400F Table2: Pin Descriptions Pin Pin Name Descriptions CLK System Clock The system clock input. All other inputs are registered to the SDRAM on the rising edge CLK. CKE Clock Enable Controls internal clock signal and when deactivated, the SDRAM will be one of the states among power down, suspend or self refresh. /CS Chip Select Enable or disable all inputs except CLK, CKE and DQM. BA0 BA1 BA0~BA1 B k Add Bank Address Selects ba bank to o be b activated a a d during du g RAS activity. a y Selects bank to be read/written during CAS activity. A0~A11 Address Row Address Column Address Auto Precharge /RAS, /CAS, /WE Row Address Strobe, Column Address Strobe, Write Enable RAS, CAS and WE define the operation. Refer function truth table for details. DQM0~DQM3 Data Input/Output Mask C t l output Controls t tb buffers ff iin read d mode d and d masks k input i t data d t in i write mode. DQ0~DQ31 Data Input/Output Data input/output pin. VDD/VSS Power Supply/Ground Power supply for internal circuits and input buffers. VDDQ/VSSQ Data Output Power/Ground Power supply for output buffers. NC No Connection No connection. Rev. A | July 2010 www.issi.com - [email protected] : RA0~RA11 : CA0~CA7 : A10 3 IS42VM32400F Figure2: Functional Block Diagram EXTENDED MODE REGISTER CLK CLOCK CKE GENERATOR TCSR ROW DECODER ROW DECODER ROW DECODER ROW DECO ODER PASR ADDRESS ROW MODE REGISTER ADDRESS BUFFER & REFRESH COUNTER BANK D BANK C BANK B BANK A SENSE AMPLIFIER /CAS / /WE CONTROL LOGIC L /RAS COMMAND DE ECODER /CS COLUMN DECODER & LATCH CIRCUIT COLUMN ADDRESS BUFFER & BURST COUNTER DATA CONTROL CIRCUIT DQM LATCH CIRCUIT INPUT & OUTPUT BUFFER DQ Rev. A | July 2010 www.issi.com - [email protected] 4 IS42VM32400F Figure3: Simplified State Diagram EXTENDED MODE REGISTER SET MODE REGISTER SET SELF REFRESH MRS ACT DEEP POWER DOWN POWER DOWN ROW ACTIVE WRITE A SUSPEND CKE ↓ CKE CKE ↓ ACTIVE POWER DOWN READ PRE E WRITE WRITE SUSPEND CBR REFRESH REF IDLE CKE ↓ READ WRITE READ WRITE CKE CKE CKE ↓ CKE ↓ WRITE A READ A CKE POWER ON CKE PRECHARGE READ SUSPEND READ A SUSPEND PRECHARGE Automatic Sequence Manual Input Rev. A | July 2010 www.issi.com - [email protected] 5 IS42VM32400F Figure4: Mode Register Definition BA1 A11 BA0 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address Bus 13 11 12 0 0 0 10 9 8 WB 0 7 0 6 5 4 CAS Latency 0 3 BT 2 1 0 Mode Register (Mx) Burst Length M9 Write Burst Mode M6 M5 M4 CAS Latency M3 Burst Type 0 Burst Read and Burst Write 0 0 0 Reserved 0 Sequential 1 Burst Read and Single Write 0 0 1 - 1 Interleave 0 1 0 0 1 1 M2 M1 M0 0 0 2 0 1 3 0 0 1 0 1 1 Burst Length M3 = 0 M3 = 1 0 1 1 0 1 2 2 0 1 0 4 4 Reserved 0 1 1 8 8 1 Reserved 1 0 0 Reserved Reserved 1 0 Reserved 1 0 1 Reserved Reserved 1 1 Reserved 1 1 0 Reserved Reserved 1 1 1 Full Page Reserved Note: M13/M12(BA1/BA0) must be set to “0/0” to select Mode Register (vs. the Extended Mode Register) Burst Type Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit M3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column add ess as shown address, sho n in Table 3. 3 Table 3: Burst Definition Burst Length Starting Column Address A2 Interleaved 0 0-1 0-1 1 1-0 1-0 0 0 0-1-2-3 0-1-2-3 0 1 1-2-3-0 1-0-3-2 1 0 2-3-0-1 2-3-0-1 1 1 3-0-1-2 3-2-1-0 0 0 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 block-of-eight burst; A0-A2 select the starting column within the block. 2 0 8 A0 0 0 1 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 0 1 0 2-3-4-5-6-7-0-1 2 3456701 2-3-0-1-6-7-4-5 2 3016745 0 1 1 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 1 0 0 4-5-6-7-0-1-2-3 4-5-6-7-0-1-2-3 1 0 1 5-6-7-0-1-2-3-4 5-4-7-6-1-0-3-2 1 1 0 6-7-0-1-2-3-4-5 6-7-4-5-2-3-0-1 1 1 1 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 Full n=A0 7 n=A0-7 Page (Location 0-255) Rev. A | July 2010 Note : Sequential A1 4 Order of Access Within a Burst 1. For full-page accesses: y = 256 2. For a burst length of two, A1-A7 select the blockof-two burst; A0 selects the starting column within the block. 3. For a burst length of four, A2-A7 select the blockof-four burst; A0-A1 select the starting column within the block. 4. For a burst length of eight, A3-A7 select the 5. For a full-page burst, the full row is selected and A0-A7 select the starting column. 6. Whenever a boundary of the block is reached within a given sequence above, the following access wraps within the block. 7. For a burst length of one, A0-A7 select the unique column to be accessed, and mode register bit M3 is ignored. Cn, Cn+1. Cn+2, Cn+3, Cn+4… Not Supported …Cn-1, Cn... www.issi.com - [email protected] 6 IS42VM32400F Figure5: Extended Mode Register BA1 A11 BA0 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address Bus 13 12 0 1 11 0 10 0 9 0 8 0 7 6 0 5 DS 4 0 3 2 0 1 0 Extended Mode Register (Ex) PASR E6 E5 Driver Strength E2 E1 E0 Self Refresh Coverage 0 0 Full Strength 0 0 0 All Banks 0 1 1/2 Strength 0 0 1 Two Banks (BA1=0) 1 0 1/4 Strength 0 1 0 One Bank (BA1=BA0=0) 1 1 Reserved 0 1 1 Reserved 1 0 0 Reserved 1 0 1 Half of One Bank (BA1=BA0=0, Row Address MSB=0) 1 1 0 Quarter of One Bank (BA1=BA0=0, Row Address 2 MSB=0) 1 1 1 Reserved Note: E13/E12(BA1/BA0) must be set to “1/0” to select Extend Mode Register (vs. the base Mode Register) Rev. A | July 2010 www.issi.com - [email protected] 7 IS42VM32400F Functional Description In general, this 128Mb SDRAM (1M x 32Bits x 4banks) is a multi-bank DRAM that operates at 1.8V and includes a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the 33,554,432-bit banks is organized as 4,096 rows by 256 columns by 32-bits Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0-BA1 select the bank, A0-A11 select the row). The address bits (BA0-BA1 select the bank, A0-A7 select the column) registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. P i to Prior t normall operation, ti th SDRAM mustt be the b initialized. i iti li d The Th following f ll i sections ti provide id detailed d t il d information i f ti covering i d i device initialization, register definition, command descriptions and device operation. Power up and Initialization SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. Once power is applied to VDD and VDDQ(simultaneously) and the clock is stable(stable clock is defined as a signal cycling within timing constraints specified for the clock pin), the SDRAM requires a 300µs delay prior to issuing any command other than a COMMAND INHIBIT or NOP. NOP CKE must be held high during the entire initialization period until the PRECHARGE command has been issued. Starting at some point during this 300µs period and continuing at least through the end of this period, COMMAND INHIBIT or NOP commands should be applied. Once the 300µs delay has been satisfied with at least one COMMAND INHIBIT or NOP command having been applied, a PRECHARGE command should be applied. All banks must then be precharged, thereby placing the device in the all banks idle state. Once in the idle state, two AUTO REFRESH cycles must be performed. After the AUTO REFRESH cycles are complete, the SDRAM is ready for mode register programming. Because the mode register will power up in an unknown state, it should be loaded prior to applying any operational command. And a extended mode register set command will be issued to program specific mode of self refresh operation(PASR). The following these cycles, the Mobile SDRAM is ready for normal operation. Register Definition Mode Register The mode register is used to define the specific mode of operation of the SDRAM. This definition includes the selection of a burst length, a burst type, a CAS latency, an operating mode and a write burst mode. The mode register is programmed via the LOAD MODE REGISTER command and will retain the stored information until it is programmed again or the device loses power. power Mode register bits M0-M2 specify the burst length, M3 specifies the type of burst (sequential or interleaved), M4-M6 specify the CAS latency, M7 and M8 specify the operating mode, M9 specifies the write burst mode, and M10-M11 should be set to zero. M12 should be set to zero to prevent extended mode register. The mode register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements will result in unspecified operation. Extended Mode Register The Extended Mode Register controls the functions beyond those controlled by the Mode Register. These additional functions are special features of the BATRAM device. They include Partial Array Self Refresh (PASR) and Driver Strength (DS). The Extended Mode Register is programmed via the Mode Register Set command and retains the stored information until it is programmed again or the device loses power. The Extended Mode Register must be programmed with M7 through M11 set to “0”. The Extended Mode Register must be loaded when all banks are idle and no bursts are in progress, and the controller must wait the specified time before initiating any subsequent operation. Violating either of these requirements results in unspecified operation. Rev. A | July 2010 www.issi.com - [email protected] 8 IS42VM32400F Burst Length Read and write accesses to the SDRAM are burst oriented, with the burst length being programmable, as shown in Figure 1. The burst length determines the maximum number of column locations that can be accessed for a given READ or WRITE command. command Burst lengths of 1, 2, 4 or 8 locations are available for both the sequential and the interleaved burst types, and a full-page burst is available for the sequential type. The full-page burst is used in conjunction with the BURST TERMINATE command to generate arbitrary burst lengths. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected by A1-A7 when the burst length g is set to two;; byy A2-A7 when the burst length g is set to four;; and byy A3-A7 when the burst length g is set to eight. g The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. Full-page bursts wrap within the page if the boundary is reached. Bank(Row) Active The Bank Active command is used to activate a row in a specified bank of the device. This command is initiated by activating CS, RAS and deasserting CAS, WE at the positive edge of the clock. The value on the BA0-BA1 selects the bank, and the value on the A0-A11 selects the row. This row remains active for column access until a precharge command is issued to that bank. Read and write operations can only be initiated on this activated bank after the minimum tRCD time is passed from the activate command. Read The READ command is used to initiate the burst read of data. This command is initiated by activating CS, CAS, and deasserting WE, RAS at the positive edge of the clock. BA0-BA1 input select the bank, A0-A7 address inputs select the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected the row being accessed will be precharged at the end of the READ burst; if Auto Precharge is not selected, the row will remain active for subsequent accesses. The length of burst and the CAS latency will be determined by the values programmed during the MRS command. Write The WRITE command is used to initiate the burst write of data. This command is initiated by activating CS, CAS, WE and deasserting RAS at the positive edge of the clock. clock BA0-BA1 input select the bank bank, A0-A7 address inputs select the starting column location. location The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected the row being accessed will be precharged at the end of the WRITE burst; if Auto Precharge is not selected, the row will remain active for subsequent accesses. Rev. A | July 2010 www.issi.com - [email protected] 9 IS42VM32400F CAS Latency The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the first piece of output data. d The h latency l can be b set to two or three h clocks. l k Iff a READ command d is registered d at clock l k edge d n, and d the h latency l is m clocks, the data will be available by clock edge n + m. The DQs will start driving as a result of the clock edge one cycle earlier (n + m 1), and provided that the relevant access times are met, the data will be valid by clock edge n + m. For example, assuming that the clock cycle time is such that all relevant access times are met, if a READ command is registered at T0 and the latency is programmed to two clocks, the DQs will start driving after T1 and the data will be valid by T2, as shown in Figure 6. Reserved states should not be used as unknown operation or incompatibility with future versions may result. Figure6: CAS Latency T0 T1 T2 T3 CLK READ COMMAND NOP NOP tOH tLZ DQ Dout tAC CAS Latency=2 T0 T1 T2 T3 T4 CLK COMMAND READ NOP NOP tLZ DQ NOP tOH Dout tAC CAS Latency=3 DON’T CARE UNDEFINED Operating Mode The normal operating mode is selected by setting M7 and M8 to zero; the other combinations of values for M7 and M8 are reserved for future use and/or test modes. The programmed burst length applies to both READ and WRITE bursts. Test modes and reserved states should not be used because unknown operation or incompatibility with future versions may result. Write Burst Mode When M9 = 0, the burst length programmed via M0-M2 applies to both READ and WRITE bursts; when M9 = 1, the programmed burst length applies to READ bursts, but write accesses are single-location (nonburst) accesses. Rev. A | July 2010 www.issi.com - [email protected] 10 IS42VM32400F Table4: Command Truth Table Function CKEn-1 CKEn /CS /RAS /CAS /WE DQM Command Inhinit (NOP) H X H X X X X X No Operation (NOP) H X L H H H X X Mode Register Set H X L L L L X OP CODE 4 Extended Mode Register Set H X L L L L X OP CODE 4 Active (select bank and activate row) H X L L H H X Bank/Row Read H X L H L H L/H Bank/Col L 5 Read with Autoprecharge H X L H L H L/H Bank/Col H 5 Write H X L H L L L/H Bank/Col L 5 Write with Autoprecharge H X L H L L L/H Bank/Col H 5 Precharge All Banks H X L L H L X X H Precharge g Selected Bank H X L L H L X Bank L Burst Stop H H L H H L X X Auto Refresh H H L L L H X X 3 Self Refresh Entry H L L L L H X X 3 Self Refresh Exit L H H X X X L H H H X X 2 Precharge Power Down Entry H L H X X X L H H H X X Precharge Down Exit L H H X X X L H H H X X Clock Suspend Entry H L H X X X L V V V X X Clock Suspend Exit L H X X Deep Power Down Entry H L X X Deep Power Down Exit L H X X X L H H X L ADDR A10 Note 6 Note : 1. CKEn is the logic state of CKE at clock edge n; CKEn-1 was the state of CKE at the previous clock edge. H: High Level, L: Low Level, X: Don't Care, V: Valid 2. Exiting Self Refresh occurs by asynchronously bringing CKE from low to high and will put the device in the all banks idle state once tXSR is met. Command Inhibit or NOP commands should be issued on any clock edges occuring during the tXSR period. A minimum of two NOP commands must be provided during tXSR period. 3. During refresh operation, internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care” except for CKE. 4. A0-A11 define OP CODE written to the mode register, and BA must be issued 0 in the mode register set, and 1 in the extended mode register set. 5. DQM “L” means the data Write/Ouput Enable and “H” means the Write inhibit/Output High-Z. Write DQM Latency is 0 CLK and Read DQM Latency is 2 CLK. 6. Standard SDRAM parts assign this command sequence as Burst Terminate. For Bat Ram parts, the Burst Terminate command is assigned to the Deep Power Down function. Rev. A | July 2010 www.issi.com - [email protected] 11 IS42VM32400F Table5: Function Truth Table Current State Idle Row Active Read Command Action Note Mode Register Set Set the Mode Register 14 X Auto or Self Refresh Start Auto or Self Refresh 5 BA X Precharge No Operation H BA R Row Add. Add B kA Bank Activate i Activate the Specified Bank and Row L L BA Col Add./ A10 Write/WriteAP ILLEGAL 4 H L H BA Col Add./ A10 Read/ReadAP ILLEGAL 4 L H H H X X No Operation No Operation 3 H X X X X X Device Deselect No Operation or Power Down 3 L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge Precharge 7 L L H H BA Row Add. Bank Activate ILLEGAL 4 L H L L BA Col Add./A10 Write/Write AP Start Write : Optional AP(A10=H) 6 L H L H BA Col Add./A10 Read/Read AP Sta t Read : Optional Start AP(A10=H) 6 L H H H X X No Operation No Operation H X X X X X Device Deselect No Operation L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge Termination Burst : Start the Precharge L L H H BA Row Add. Bank Activate ILLEGAL L H L L BA Col Add./A10 Write/WriteAP Termination Burst : Start Write(AP) 8,9 L H L H BA Col Add./A10 Read/Read AP Terimination Burst : Start Read(AP) 8 L H H H X X No Operation Continue the Burst H X X X X X Device Deselect Continue the Burst /CS /RAS /CAS /WE L L L L L L L H X L L H L L L H L H L Rev. A | July 2010 BA A0-A11 OP CODE OP CODE OP CODE Description www.issi.com - [email protected] 4 12 IS42VM32400F Table5: Function Truth Table Current State Write Read with Auto Precharge Write with Auto Precharge Rev. A | July 2010 Command /CS /RAS /CAS /WE BA L L L L L L L H X L L H L L L H L H L A0-A11 OP CODE Description Action Note Mode Register Set ILLEGAL 13,14 X Auto or Self Refresh ILLEGAL 13 BA X Precharge Termination Burst : Start the Precharge 10 H BA Row Add. Bank Activate ILLEGAL 4 L L BA Col Add./A10 Write/WriteAP Termination Burst : Start Write(AP) 8 H L H BA Col Add./A10 Read/ReadAP Terimination Burst : Start READ(AP) 8,9 L H H H X X No Operation Continue the Burst H X X X X X Device Deselect Continue the Burst L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 4,12 L L H H BA Row Add. Bank Activate ILLEGAL 4,12 L H L L BA Col Add./A10 Write/WriteAP ILLEGAL 12 L H L H BA Col Add./A10 Read/ReadAP ILLEGAL 12 L H H H X X No Operation Continue the Burst H X X X X X Device Deselect Continue the Burst L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 4,12 L L H H BA Row Add. Bank Activate ILLEGAL 4,12 L H L L BA Col Add./A10 Write/WriteAP ILLEGAL 12 L H L H BA Col Add./A10 Read/ReadAP ILLEGAL 12 L H H H X X No Operation Continue the Burst H X X X X X Device Deselect Continue the Burst OP CODE OP CODE www.issi.com - [email protected] 13 IS42VM32400F Table5: Function Truth Table Current State P echa ging Precharging Row Activating Write Recovering Rev. A | July 2010 Command /CS /RAS /CAS /WE BA L L L L L L L H X L L H L L L H L H L A0-A11 OP CODE Description Action Note Mode Register Set ILLEGAL 13,14 X Auto or Self Refresh ILLEGAL 13 BA X Precharge No Operation : Bank(s) Idle after tRP H BA Row Add. Bank Activate ILLEGAL 4,12 L L BA Col Add./ A10 Write/WriteAP ILLEGAL 4,12 H L H BA Col Add./ A10 Read/ReadAP ILLEGAL 4,12 L H H H X X No Operation No Operation : Bank(s) Idle after tRP H X X X X X Device Deselect No Operation : Bank(s) Idle after tRP L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 4,12 L L H H BA Row Add. Bank Activate ILLEGAL 4,11,12 L H L L BA Col Add./A10 Write/Write AP ILLEGAL 4,12 L H L H BA Col Add./A10 Read/Read AP ILLEGAL 4,12 L H H H X X No Operation No Operation : ROw Active after tRCD H X X X X X Device Deselect No Operation : ROw Active after tRCD L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 4,13 L L H H BA Row Add. Bank Activate ILLEGAL 4,12 L H L L BA Col Add./A10 Write/WriteAP Start Write : Optional AP(A10=H) L H L H BA Col Add./A10 Read/Read AP Start Write : Optional AP(A10=H) L H H H X X No Operation No Operation : Row Active after tDPL H X X X X X Device Deselect No Operation : Row Active after tDPL OP CODE OP CODE www.issi.com - [email protected] 9 14 IS42VM32400F Table5: Function Truth Table Current State Write Recovering with Auto Precharge Refreshing Mode Register Accessing Rev. A | July 2010 Command /CS /RAS /CAS /WE BA L L L L L L L H X L L H L L L H L H L A0-A11 OP CODE Description Action Note Mode Register Set ILLEGAL 13,14 X Auto or Self Refresh ILLEGAL 13 BA X Precharge ILLEGAL 4,13 H BA Row Add. Bank Activate ILLEGAL 4,12 L L BA Col Add./ Add / A10 Write/WriteAP ILLEGAL 4 12 4,12 H L H BA Col Add./ A10 Read/ReadAP ILLEGAL 4,9,12 L H H H X X No Operation No Operation : Precharge after tDPL H X X X X X Device Deselect No Operation : Precharge after tDPL L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 13 L L H H BA Row Add. Bank Activate ILLEGAL 13 L H L L BA Col Add./A10 Write/Write AP ILLEGAL 13 L H L H BA Col Add./A10 Read/Read AP ILLEGAL 13 L H H H X X No Operation No Operation : Idle after f tRC C H X X X X X Device Deselect No Operation : Idle after tRC L L L L Mode Register Set ILLEGAL 13,14 L L L H X X Auto or Self Refresh ILLEGAL 13 L L H L BA X Precharge ILLEGAL 13 L L H H BA Row Add. Add Bank Activate ILLEGAL 13 L H L L BA Col Add./A10 Write/WriteAP ILLEGAL 13 L H L H BA Col Add./A10 Read/Read AP ILLEGAL 13 L H H H X X No Operation No Operation : Idle after 2 Clock Cycle H X X X X X Device Deselect No Operation : Idle after 2 Clock Cycle OP CODE OP CODE www.issi.com - [email protected] 15 IS42VM32400F Note : 1 H: 1. H LLogic i High, Hi h L: L Logic L i Low, L X: X Don't D 't care, BA: BA Bank B k Address, Add AP: AP Auto A t Precharge. P h 2. All entries assume that CKE was active during the preceding clock cycle. 3. If both banks are idle and CKE is inactive, then in power down cycle 4. Illegal to bank in specified states. Function may be legal in the bank indicated by Bank Address, depending on the state of that bank. 5. If both banks are idle and CKE is inactive, then Self Refresh mode. 6. Illegal if tRCD is not satisfied. 7. Illegal if tRAS is not satisfied. 8. Must satisfy burst interrupt condition. 9. Must satisfy bus contention, bus turn around, and/or write recovery requirements. 10. Must mask preceding data which don't satisfy tDPL. 11. Illegal if tRRD is not satisfied 12. Illegal for single bank, but legal for other banks in multi-bank devices. 13. Illegal for all banks. 14. Mode Register Set and Extended Mode Register Set is same command truth table except BA. Rev. A | July 2010 www.issi.com - [email protected] 16 IS42VM32400F Table6: CKE Truth Table Current State CKE Command A i Action N Note Prev Cycle Current Cycle /CS /RAS /CAS /WE BA A0-A11 H X X X X X X X INVALID 2 L H H X X X X X Exit Self Refresh with Device Deselect 3 L H L H H H X X Exit Self Refresh with No Operation 3 L H L H H L X X ILLEGAL 3 L H L H L X X X ILLEGAL 3 L H L L X X X X ILLEGAL 3 L L X X X X X X Maintain Self Refresh H X X X X X X X INVALID 2 L H H X X X X X L H H H X X Power Down Mode Exit, All Banks Idle 3 L X X X X X L X X X X X L X X Self Refresh Power Down L Deep Power Down All Banks Idle Any State other than listed above Rev. A | July 2010 H L ILLEGAL 3 L L X X X X X X Maintain Power Down Mode H X X X X X X X INVALID 2 L H X X X X X X Deep Power Down Mode Exit 6 L L X X X X X X Maintain Deep Power Down Mode H H H X X X H H L H X X H H L L H X H H L L L H H H L L L L H L H X X X H L L H X X H L L L H X H L L L L H H L L L L L L X X X X X X X Power Down H H X X X X X X Refer to Operations of the Current State Truth Table H L X X X X X X Begin Clock Suspend next cycle L H X X X X X X Exit Clock Suspend next cycle L L X X X X X X Maintain Clock Suspend Refer to the Idle State section of the Current State Truth Table 4 4 4 X X OP CODE Auto Refresh Mode Register Set 5 Refer to the Idle State section of the Current State Truth Table 4 4 4 X X Entry Self Refresh OP CODE Mode Register Set www.issi.com - [email protected] 5 5 17 IS42VM32400F Note : 1. H: Logic High, L: Logic Low, X: Don't care 2. For the given current state CKE must be low in the previous cycle. 3. When CKE has a low to high transition, the clock and other inputs are re-enabled asynchronously. When exiting power down mode, a NOP (or Device Deselect) command is required on the first positive edge of clock after CKE goes high. 4. The address inputs depend on the command that is issued. 5. The Precharge Power Down mode, the Self Refresh mode, and the Mode Register Set can only be entered from the all banks idle state. 6. When CKE has a low to high transition, the clock and other inputs are re-enabled asynchronously. When exiting deep power down mode, a NOP (or Device Deselect) command is required on the first positive edge of clock after CKE goes high and is maintained for a minimum 300usec. 300usec Rev. A | July 2010 www.issi.com - [email protected] 18 IS42VM32400F Table7: Absolute Maximum Rating Parameter Symbol Ambient Temperature (Industrial) Rating -40 ~ 85 TA Ambient Temperature (Commercial) Unit °C 0 ~ 70 TSTG -55 ~ 150 °C VIN, VOUT -1.0 ~ 2.6 V VDD, VDDQ -1.0 ~ 2.6 V Short Circuit Output Current IOS 50 mA Power Dissipation PD 1 W Storage Temperature Voltage on Any Pin relative to VSS Voltage on VDD relative to VSS Note : Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Table8: Capacitance (TA=25 °C, f=1MHz, VDD=1.8V) Parameter Input Capacitance Pin Symbol Min Max Unit CLK CI1 2 4 pF A0~A11, BA0~BA1, CKE, /CS, /RAS, /CAS /WE /CAS, /WE, DQM0 DQM0~DQM3 DQM3 CI2 2 4 pF p DQ0~DQ31 CIO 3 5 pF Data Input/Output Capacitance Table9: DC Operating Condition (Voltage referenced to VSS=0V, TA= -40 ~ 85 °C) Parameter Symbol Min Typ Max Unit VDD 1.7 1.8 1.95 V VDDQ 1.7 1.8 1.95 V 1 Input High Voltage VIH 0.8 x VDDQ - VDDQ+0.3 V 2 Input Low Voltage VIL -0.3 0 0.3 V 3 Output High Voltage VOH 0.9 x VDDQ - - V IOH= -0.1mA Output Low Voltage VOL - - 02 0.2 V IOL= +0.1mA +0 1mA Input Leakage Current ILI -1 - 1 uA 4 Output Leakage Current ILO -1.5 1.5 uA 5 Power Supply Voltage Note Note : 1. VDDQ must not exceed the level of VDD 2. VIH(max) = VDDQ+1.5V AC. The overshoot voltage duration is ≤ 3ns. 3. VIL(min) = -1.0V AC. The overshoot voltage duration is ≤ 3ns. 4. Any input 0V 0 ≤ VIN ≤ VDDQ. Q Input leakage currents include Hi-Z output leakage for all bi-directional buffers with tri-state outputs. 5. DOUT is disabled, 0V ≤ VOUT ≤ VDDQ. Rev. A | July 2010 www.issi.com - [email protected] 19 IS42VM32400F Table10: AC Operating Condition (TA= -40 ~ 85 °C, VDD = 1.8V, VSS=0V) P Parameter t S Symbol b l T Typ U it Unit VIH / VIL 0.9 x VDDQ / 0.2 V Input Timing Measurement Reference Level Voltage VTRIP 0.5 x VDDQ V Input Rise / Fall Time tR / tF 1/1 ns VOUTREF 0.5 x VDDQ V CL 30 pF AC Input High/Low Level Voltage Output Timing Measurement Reference Level Voltage Output Load Capacitance for Access Time Measurement VTT=0.5 x VDDQ VDDQ 500Ω Output 50Ω Output 500Ω 30pF 30pF DC Output Load Circuit Rev. A | July 2010 Z0=50Ω Z0 50Ω AC Output Load Circuit www.issi.com - [email protected] 20 IS42VM32400F Table11: DC Characteristic (DC operating conditions unless otherwise noted) P Parameter t Speed S Sym T t Condition Test C diti Operating Current ICC1 Burst Length=1, One Bank Active, tRC ≥ tRC(min) IOL = 0 mA Precharge Standby Current in Power Down Mode ICC2P CKE ≤ VIL(max), tCK = 10ns 0.3 ICC2PS CKE & CLK ≤ VIL(max), tCK = ∞ 0.3 ICC2N CKE ≥ VIH(min), /CS ≥ VIH(min), tCK = 10ns Input signals are changed one time during 2 clks clks. 10 ICC2NS CKE ≥ VIH(min), CLK ≤ VIL(max), tCK = ∞ Input signals are stable. 3 ICC3P CKE ≤ VIL(max), tCK = 10ns 5 ICC3PS CKE & CLK ≤ VIL(max), tCK = ∞ 1 ICC3N CKE ≥ VIH(min), /CS ≥ VIH(min), tCK = 10ns Input signals are changed one time during 2 clks. 20 ICC3NS CKE ≥ VIH(min), CLK ≤ VIL(max), tCK = ∞ Input signals are stable. 10 Precharge Standby Current in Non Power Down Mode Active Standby Current in Power Down Mode Active Standby Current in Non Power Down Mode -75 -10 50 45 U it Unit N t Note mA 1 mA mA mA mA Burst Mode Operating Current ICC4 tCK>tCK(min), IOL = 0 mA, Page Burst All Banks Activated, tCCD = 1 clk 110 105 mA 1 Auto Refresh Current (4K Cycle) ICC5 tRC ≥ tRFC(min), All Banks Active 100 95 mA 2 PASR 4 banks Self Refresh Current 2 Bank 1 Bank TCSR 85°C 350 45°C 180 85°C ICC6 CKE ≤ 0.2V 310 45°C 160 85°C 290 45°C 150 Deep Power Down Mode Current ICC7 30 uA uA Note : 1. Measured with outputs open. 2. Refresh period is 64ms. Rev. A | July 2010 www.issi.com - [email protected] 21 IS42VM32400F Table12: AC Characteristic (AC operation conditions unless otherwise noted) Parameter Sym CLK Cycle Time Access time from CLK (pos. edge) -75 75 Min -10 10 Max Min CL = 3 tCK3 7.5 CL = 2 tCK2 10 CL = 3 tAC3 6 8 CL = 2 tAC2 8 8 1000 10 Max 10 Unit 1000 Note 1 2 CLK High-Level Width tCH 2.5 2.5 3 CLK Low-Level Width tCL 2.5 2.5 3 CKE Setup Time tCKS 2.0 2.0 CKE Hold Time tCKH 1.0 1.0 /CS, /RAS, /CAS, /WE, DQM Setup Time tCMS 2.0 2.0 /CS, /RAS, /CAS, /WE, DQM Hold Time tCMH 1.0 1.0 Address Setup Time tAS 2.0 2.0 Address Hold Time tAH 1.0 1.0 Data-In Setup Time tDS 2.0 2.0 Data-In Data In Hold Time tDH 10 1.0 10 1.0 Data-Out High-Impedance Time from CLK (pos.edge) ns CL = 3 tHZ3 6 8 CL = 2 tHZ2 8 8 Data-Out Low-Impedance Time tLZ 1.0 1.0 Data-Out Hold Time (load) tOH 2.5 2.5 Data-Out Hold Time (no load) tOHN 1.8 1.8 ACTIVE to PRECHARGE command tRAS 45 PRECHARGE command period tRP 22.5 24 100K 40 4 100K ACTIVE bank b k a to ACTIVE bank b k a command d tRC 67.5 64 ACTIVE bank a to ACTIVE bank b command tRRD 15 20 5 ACTIVE to READ or WRITE delay tRCD 22.5 30 READ/WRITE command to READ/WRITE command tCCD 1 1 WRITE command to input data delay tDWD 0 0 6 Data-in to PRECHARGE command tDPL 15 20 7 Data-in to ACTIVE command tDAL 37.5 40 CLK ns 6 7 DQM to data high-impedance during READs tDQZ 2 2 6 DQM to data mask during WRITEs tDQM 0 0 6 LOAD MODE REGISTER command to ACTIVE or REFRESH command tMRD 2 2 CL = 3 tROH3 3 3 CL = 2 tROH2 2 2 Last data-in to burst STOP command tBDL 1 1 6 Last data-in to new READ/WRITE command tCDL 1 1 6 tCKED 1 1 Data-out to high-impedance from PRECHARGE command CKE to clock disable or power-down entry mode CKE to clock enable or power-down exit setup mode tPED 1 9 1 tREF AUTO REFRESH period tRFC 67.5 70 Exit SELF REFRESH to ACTIVE command tXSR 67.5 70 tT 0.5 Rev. A | July 2010 6 CLK Refresh period (4,096 rows) Transition time 8 CLK 64 1.2 www.issi.com - [email protected] 9 64 0.5 ms 5 ns 5 1.2 22 IS42VM32400F Note : 1. The clock frequency must remain constant (stable clock is defined as a signal cycling within timing constraints specified for the clock pin) during access or precharge states (READ, WRITE, including tDPL, and PRECHARGE commands). CKE may be used to reduce the data rate. 2. tAC at CL = 3 with no load is 5.5ns and is guaranteed by design. Access time to be measured with input signals of 1V/ns edge rate, from 0.8V to 0.2V. If tR > 1ns, then (tR/2-0.5)ns should be added to the parameter. 3. AC characteristics assume tT = 1ns. If tR & tF > 1ns, then [(tR+tF)/2-1]ns should be added to the parameter. 4. tHZ defines the time at which the output achieves the open circuit condition; it is not a reference to VOH or VOL. The last valid data element will meet tOH before going High-Z. 5. Parameter guaranteed by design. A. Target values listed with alternative values in parentheses. B tRFC mustt be B. b less l th or equall to than t tRC+1CLK tRC 1CLK tXSR must be less than or equal to tRC+1CLK 6. Required clocks are specified by JEDEC functionality and are not dependent on any timing parameter. 7. Timing actually specified by tDPL plus tRP; clock(s) specified as a reference only at minimum cycle rate 8. JEDEC and PC100 specify three clocks. 9. Timing actually specified by tCKs; clock(s) specified as a reference only at minimum cycle rate. 10. A new command can be given tRC after self refresh exit. Rev. A | July 2010 www.issi.com - [email protected] 23 IS42VM32400F Special Operation for Low Power Consumption Temperature e pe atu e Co Compensated pe sated Se Self Refresh e es Temperature Compensated Self Refresh allows the controller to program the Refresh interval during SELF REFRESH mode, according to the case temperature of the Mobile SDRAM device. This allows great power savings during SELF REFRESH during most operating temperature ranges. Only during extreme temperatures would the controller have to select a TCSR level that will guarantee data during SELF REFRESH. Every cell in the DRAM requires refreshing due to the capacitor losing its charge over time. The refresh rate is dependent on temperature. At higher temperatures a capacitor loses charge quicker than at lower temperatures, requiring the cells to be refreshed more often. Historically, during Self Refresh, the refresh rate has been set to accommodate the worst case, or highest temperature range expected. Thus, during ambient temperatures, the power consumed during refresh was unnecessarily high, because the refresh rate was set to accommodate the higher temperatures. This temperature compensated refresh rate will save power when the DRAM is operating at normal temperatures. Partial Array Self Refresh For further power savings during SELF REFRESH, the PASR feature allows the controller to select the amount of memory that will be refreshed during SELF REFRESH. The refresh options are All Banks;all four banks, Two Banks;bank a and b, One Bank;bank a, Half of One Bank;1/2 of bank a, Quarter of One Bank;1/4 of bank a. WRITE and READ commands can still occur during standard operation, but only the selected banks will be refreshed during SELF REFRESH. Data in banks that are disabled will be lost. Deep Power Down Deep Power Down is an operating mode to achieve maximum power reduction by eliminating the power of the whole memory array of the devices. Data will not be retained once the device enters Deep Power Down Mode. This mode is entered by having all banks idle then /CS and /WE held low with /RAS and /CAS held high at the rising edge of the clock, while CKE is low. This mode is exited by asserting CKE high. Rev. A | July 2010 www.issi.com - [email protected] 24 IS42VM32400F Figure7: Deep Power Down Mode Entry CLK CKE /CS //RAS /CAS /WE tRP DON’T CARE Deep Power Down Entry Precharge if needed Figure8: Deep Power Down Mode Exit CLK CKE /CS /RAS /CAS /WE 100 µ s Deep Power Down Exit tRP tRFC Auto Refresh All Banks Precharge Mode Register Set Auto Refresh New Command Extended Mode Register Set DON’T CARE Rev. A | July 2010 www.issi.com - [email protected] 25 Rev. A | July 2010 0.80 Package Outlline 0.45 www.issi.com - [email protected] 08/14/20088 1. CONTROLLING DIMENSION : MM . 2. Reference document : JEDEC MO-207 NOTE : IS42VM32400F Figure9: 90Ball FBGA Configuration 26 IS42VM32400F Ordering Information – VDD = 1.8V Industrial Range: (-40oC to +85oC) Configuration Frequency (MHz) Speed (ns) 4Mx32 133 7.5 Rev. A | July 2010 Order Part No. Package IS42VM32400F-75BLI 90-ball BGA, Lead-free www.issi.com - [email protected] 27