Total Power MSGWI06 Ultra compact smd package 22.0 x 20.3 x 10.2 mm (0.87 x 0.80 x 0.40 inches) Datasheet

FEATURES
►Ultra compact SMD Package
22.0 x 20.3 x 10.2 mm (0.87 x 0.80 x 0.40 inches)
►Ultra wide 4:1 Input Range
►Fully regulated Output
►Operating Temp. Range –40°C to +80°C
►Over Load Protection
►Remote On/Off Control
►I/O-isolation 1500 VDC
►Input Filter meets EN 55022,class A and FCC, level A
►Qualified for lead-free Reflow Solder Process according
IPC/JEDEC J-STD-020D
►CSA/UL/IEC/EN 60950-1 Safety Approval
►3 Years Product Warranty
PRODUCT OVERVIEW
The MSGWI06 series is a new range of isolated 6W DC/DC converter modules featuring fully regulated output voltages and ultra-wide 4:1 input voltage
ranges. These products are with a very small footprint occupying just 4.5cm2 (0.7 square in.) on PCB. All models are qualified for lead free reflow solder
processes according IPC J-STD-020D.An excellent efficiency allows an operating temperature range of –40° to +80°C. Further features include remote
On/Off control and over load protection.
The very compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications in battery-powered equipment
and instrumentation.
Model Selection Guide
Model
Input
Output
Output
Number
Voltage
Voltage
Current
(Range)
VDC
MSGWI06-24S033
MSGWI06-24S05
MSGWI06-24S12
MSGWI06-24S15
MSGWI06-24S24
MSGWI06-24D05
MSGWI06-24D12
MSGWI06-24D15
MSGWI06-48S033
MSGWI06-48S05
MSGWI06-48S12
MSGWI06-48S15
MSGWI06-48S24
MSGWI06-48D05
MSGWI06-48D12
MSGWI06-48D15
24
(9 ~ 36)
48
(18 ~ 75)
VDC
3.3
5
12
15
24
±5
±12
±15
3.3
5
12
15
24
±5
±12
±15
Input Current
Max.
Min.
@Max. Load
mA
1450
1200
500
400
250
±600
±250
±200
1450
1200
500
400
250
±600
±250
±200
mA
218
180
75
60
38
±90
±38
±30
218
180
75
60
38
±90
±38
±30
mA(typ.)
262
316
301
301
301
301
301
301
131
158
151
151
151
151
151
151
@No Load
mA(typ.)
Max. capacitive
Efficiency
Load
(typ.)
@Max. Load
μF
%
76
79
83
83
83
82
83
83
76
79
83
83
83
82
83
83
330
100
30
100#
330
100
20
100#
# For each output
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Short Circuit Input Power
Conducted EMI
In
Total Power International,
Inc
Model
Min.
Typ.
Max.
24V Input Models
-0.7
---
50
100
48V Input Models
-0.7
---
24V Input Models
---
---
9
48V Input Models
---
---
18
24V Input Models
---
---
8.5
48V Input Models
---
---
17
---
---
3000
All Models
Unit
VDC
mW
Compliance to EN 55022,class A and FCC part 15,class A
Toll Free: 877-646-0900
www.total-power.com
MSGWI06 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 6W, SMD Package
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
At 50% Load
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=15% to 100%
Min.
----------------110
25% Load Step Change
Foldback
Typ.
Max.
±1.0
±2.0
±1.0
--±0.5
±1.0
±0.5
±1.2
60
100
300
600
±3
--±0.01
±0.02
150
--Continuous
Unit
%Vnom.
%
%
%
mV P-P
μsec
%
%/℃
%
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Moisture Sensitivity Level (MSL)
Safety Approvals
Conditions
60 Seconds
500 VDC
100KHz, 1V
Min.
1500
1000
----350,000
Typ.
----1200
330
---
Max.
----1500
-----
MIL-HDBK-217F@25℃, Ground Benign
IPC/JEDEC J-STD-020D
Level 2
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Unit
VDC
MΩ
pF
KHz
Hours
Input Fuse
24V Input Models
1500mA Slow-Blow Type
48V Input Models
750mA Slow-Blow Type
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (on)
Control Input Current (off)
Control Common
Standby Input Current
Conditions
Vin-RC=5V
Vin-RC=0V
Min.
2.5V ~ 50VDC or Open Circuit
-0.7V ~ 0.8V
----Referenced to Negative Input
---
Typ.
Max.
Unit
-----
500
-500
μA
μA
---
10
mA
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Natural Convection
Min.
-40
---50
--Free-Air convection
---
Max.
+80
+105
+125
95
Unit
℃
℃
℃
% rel. H
260
℃
Power Derating Curve
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MSGWI06 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 6W, SMD Package
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
3
Ripple & Noise measurement bandwidth is 0-20MHz.
4
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
5
All DC/DC converters should be externally fused at the front end for protection.
6
Other input and output voltage may be available, please contact factory.
however, they may not meet all specifications listed.
7
It is not recommended to use water-washing process on SMT units.
8
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Connecting Pin Patterns
17.78 [0.70]
5.08 [0.20]
22.0 [0.87]
12.7 [0.5]
11
9
20.3 [0.8]
16
3.0 [0.12]
5.08
[0.2]
1 2
6
27.0 [1.06]
25.4 [1.0]
2.11
[0.08]
8
2.54 [0.10]
1.9 [0.07]
10.2 0.5
[0.4 0.02]
1.5 [0.06]
S SEATING
PLANE
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
0~
4
0.15
[0.01]
10.05 [0.4]
2.54 [0.1]
X.XX±0.13 ( X.XXX±0.005)
0.1 S
►Pins ±0.05(±0.002)
Pin Connections
Physical Characteristics
Pin
Single Output
Dual Output
1
Remote On/Off
Remote On/Off
2
-Vin
-Vin
6
NC
Common
8
NC
-Vout
9
+Vout
+Vout
11
-Vout
Common
16
+Vin
+Vin
Case Size
:
22.0x20.3x10.2 mm (0.87x0.8x0.4 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Phosphor bronze
Weight
:
7.8g
NC: No Connection
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MSGWI06 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 6W, SMD Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.
A logic low is -0.7V to 0.8V. A logic high is 2.5V to 50V. he maximum sink current of the switch at on/off terminal during a logic low is -500 μA.
The maximum sink current of the switch at on/off terminal during a logic high is 500μA or open.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
Com.
DC / DC
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MSGWI06 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com