ACE ACE358 The ace358 consists of two independent high gain, internally frequency compensated operational amplifier. it can be operated from a single power supply and also split power supplies. Datasheet

ACE358
Dual Operational Amplifier
Description
The ACE358 consists of two independent high gain, internally frequency compensated operational
amplifier. It can be operated from a Single power supply and also split power supplies.
Features




Internally frequency compensated for unity gain
Wide power supply range 3V~32V
Input common-mode voltage range include ground
Large DC Voltage gain
Applications


General purpose amplifier
Transducer amplifier
Absolute Maximum Ratings
O
(TA=25 C)
Parameter
Symbol
Max
Unit
Supply Voltage
VCC
±16 or 32
V
Differential Input Voltage
VI(DIFF)
±32
V
Input Voltage
VI
-0.3~32
V
Output Short to Ground
Continuous
Operating Temperature Range
TOPR
0~70
O
C
Storage Temperature Range
TSTG
-65~150
O
C
Packaging Type
SOP-8
1
8
2
7
3
6
4
5
8
SOP-8
Description
1
Output 1
2
Input1(-)
3
Input1(+)
4
VEE/GND
5
Input2(+)
6
Input2(-)
7
Output2
8
Vcc
VER1.3
1
ACE358
Dual Operational Amplifier
Ordering information
ACE358 XX + H
Halogen-free
Pb-free
FM : SOP-8
Block Diagram
Electrical Characteristics
(VCC=5.0V VEE=GND,TA=25,unless otherwise specified)
Symbol
Parameter
VIO
Input Offset Voltage
IIO
IBIAS
VI(R)
Min Typ
Max
Unit
2.9
7.0
mV
Input Offset Current
5
50
nA
Input Bias Current
Input Common Mode
Voltage
45
250
nA
VCC-1.5
V
ICC
Power Supply Current
GV
Large Signal Voltage
Gain
VO(H)
Output Voltage Swing
PSRR
VCC=30V
0
RL=∞,VCC=30V
0.8
2.0
mA
RL=∞,Full Temperature Range
0.5
1.2
mA
VCC=15V,RL>=2KΩ VO(P)=1V to 11V
25
VCC=30V,RL=2KΩ
26
VCC=30V,RL=10KΩ
27
VCC=5V,RL>=10KΩ
VO(L)
CMRR
Test Condition
VCM=0V to VCC-1.5V
VO(P)=1.4V,RS=0Ω
Common Mode Rejection
Ratio
Power Supply Rejection
100
V/mV
V
28
5
V
20
mV
65
80
dB
65
100
dB
VER 1.3
2
ACE358
Dual Operational Amplifier
Ration
CS
ISC
Channel Separation
Short Circuit Current to
Ground
ISOURCE
Output Current
ISINK
VI(DIFF)
Differential Input Voltage
F=1KHZ to 20KHZ
120
40
VI(+)= 1V,VI(-)=0V
VCC=15V,VO(P)=2V
VI(+)=0V,,VI(-)=1V
VCC=15V,VO(P)=2V
VI(+)=0V,,VI(-)=1V
VCC=15V,VO(P)=200mV
dB
60
mA
10
30
mA
10
15
mA
12
100
µA
VCC
V
Typical Performance Characteristics
VER 1.3
3
ACE358
Dual Operational Amplifier
VER 1.3
4
ACE358
Dual Operational Amplifier
VER 1.3
5
ACE358
Dual Operational Amplifier
Packing Information
SOP-8
VER 1.3
6
ACE358
Dual Operational Amplifier
Notes
ACE does not assume any responsibility for use as critical components in life support devices or systems
without the express written approval of the president and general counsel of ACE Electronics Co., LTD.
As sued herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and shoes failure to perform when properly used in
accordance with instructions for use provided in the labeling, can be reasonably expected to result in
a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can
be reasonably expected to cause the failure of the life support device or system, or to affect its safety
or effectiveness.
ACE Technology Co., LTD.
http://www.ace-ele.com/
VER 1.3
7
Similar pages