Current Transducer HX 02..06-P IPN = 2 .. 6 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal Primary current r.m.s. current measuring range IPN (A) IP (A) 2 3 4 6 VOUT ROUT RL VC IC Vd Ve ±6 ±9 ±12 ±18 Primary Conductor Diameter x Turns (mm) 0.5d 0.6d 0.7d 1.0d x x x x 30T 20T 15T 10T Type Features • Galvanic isolation between primary HX 02-P HX 03-P HX 04-P HX 06-P Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output impedance Load resistance Supply voltage (± 5 %)1) Current consumption R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn R.m.s. voltage for partial discharge extinction at 10pC Impulse withstand voltage, 1.2/50µs ±4 < 50 ≥ 10 ± 15 < ± 15 >3 ≥1 ≥6 V Ω kΩ V mA kV kV kV • • • • • • and secondary circuit Hall effect measuring principle Isolation voltage 3000V Low power consumption Extended measuring range(3x IPN) Power supply from ±12V to ±15V Material according to UL94-V0 Advantages • Low insertion losses • Easy to mount with automatic handling system Accuracy-Dynamic performance data X ε L VOE VOH VOT TCε G tr f Accuracy @ IPN, TA = 25°C (without offset) Linearity error (0 .. ± IPN) Electrical offset voltage, TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 3 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth (-3 dB) 2) < ± 1 % of IPN < ± 1 % of IPN < ± 40 mV < ± 15 max. ± 1.5 ± 0.1 ≤ 3 50 mV mV/K %/K µs kHz Ambient operating temperature Ambient storage temperature Mass Min. internal creepage distance/clearance Isolation material group Standards ratings range • High immunity to external interference. Applications • Switched Mode Power Supplies (SMPS) • AC variable speed drives • Uninterruptible Power Supplies General data TA TS m • Small size and space saving • Only one design for wide current - 25 .. + 85 °C - 25 .. + 85 °C 8 g ≥ 5.5 mm I EN50178 (UPS) • Electrical appliances • Battery supplied applications • DC motor drives Application Domain • Industrial Notes : 1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN 2) Small signal only to avoid excessive heating of the magnetic cores Page 1/2 060920/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HX 02..06-P (in mm. 1 mm = 0.0394 inch) HX 02..06-P HX03...25-P 02..25-P HX 50-P HXHX50-P Terminal Pin Identification 19 Max. 19 Max. 20 Max. 3 3 8.8 6 6 3-P=2.54 03-P 0.6 04-P 0.7 06-P 1.0 5 3Secondary +V pins dimension 2 0 0.5 x 0.25 1 -V or 0 1.3 3.5 6 5 4.5 2 0 1 -V or 0 02-P 0.6 0.5 4 OUT 3 +V 15.4 Max. 3.5 3-P=2.54 4 OUT 5.4 HX d d 15.4 Max. 10.85 Primary conductor diameter 5 3 3.5 3.5 3.5 0.5 0.5 20 Max. 1 ..... -15 V 2 ..... 0 V 3 ..... +15 V 4 ..... Output 5 ..... Primary input Current (+) 6 ..... Primary input Current (-) 1.2 3 10.85 3 8.8 Top view 5.4 HX HX 05-P 02-P 41123 Lot No. Terminal Pin Identification 1.....-15V 2.....0V 3.....+15V 4.....Output 5.....Primary input Current(+) 6.....Primary input Current(-) Primary conductor diameter / dimension HX Safety 03-P 05-P 10-P 15-P 20-P 25-P 50-P d 0.6 1.4 0.8 1.1 1.6 1.6 1.2x6.3 Secondary pins dimension This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. 0.5x0.25 Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 060920/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com