LINER LTC1922EN-1 Synchronous phase modulated full-bridge controller Datasheet

LTC1922-1
Synchronous Phase
Modulated Full-Bridge Controller
DESCRIPTIO
U
FEATURES
■
■
■
■
■
■
■
■
■
■
■
■
Adaptive DirectSenseTM Zero Voltage Switching
Integrated Synchronous Rectification Control for
Highest Efficiency
Output Power Levels from 50W to Kilowatts
Very Low Start-Up and Quiescent Currents
Compatible with Voltage Mode and Current Mode
Topologies
Programmable Slope Compensation
Undervoltage Lockout Circuitry with 4.2V Hysteresis
and Integrated 10.3V Shunt Regulator
Fixed Frequency Operation to 1MHz
50mA Outputs for Bridge Drive and Secondary Side
Synchronous Rectifiers
Soft-Start, Cycle-by-Cycle Current Limiting and
Hiccup Mode Short-Circuit Protection
5V, 15mA Low Dropout Regulator
20-Pin PDIP and SSOP Packages
U
APPLICATIO S
■
■
■
Telecommunications, Infrastructure Power Systems
Distributed Power Architectures
Server Power Supplies
High Density Power Modules
The LTC1922-1 also provides secondary side synchronous rectifier control. The device uses peak current mode
control with programmable slope comp and leading edge
blanking.
The LTC1922-1 features extremely low operating and
start-up currents to simplify off-line start-up and bias
circuitry. The LTC1922-1 also includes a full range of
protection features and is available in 20-pin through hole
(N) and surface mount (G) packages.
, LTC and LT are registered trademarks of Linear Technology Corporation.
DirectSense is a trademark of Linear Technology Corporation.
U
■
The LTC®1922-1 phase shift PWM controller provides all
of the control and protection functions necessary to implement a high performance, zero voltage switched, phase
shift, full-bridge power converter with synchronous rectification. The part is ideal for developing isolated, low
voltage, high current outputs from a high voltage input
source. The LTC1922-1 combines the benefits of the fullbridge topology with fixed frequency, zero voltage switching operation (ZVS). Adaptive ZVS circuity controls the
turn-on signals for each MOSFET independent of internal
and external component tolerances for optimal performance.
TYPICAL APPLICATIO
VIN
48V
BIAS
SUPPLY
Efficiency
100
VOUT
3.3V
EFFICIENCY (%)
90
VIN = 48V
VIN = 36V
80
70
LTC1922-1
ISOLATED
FEEDBACK
60
0
10
20
30
40
LOAD CURRENT (A)
1922 • TA01b
1922 TA01a
1
LTC1922-1
U
W W
W
ABSOLUTE
AXI U RATI GS
U
W
U
PACKAGE/ORDER I FOR ATIO
(Note 1)
ORDER PART
NUMBER
TOP VIEW
VCC to GND
Low Impedance Source ......................... –0.3V to 10V
(Chip Self Regulates at 10.3V)
All Other Pins to GND
(Low Impedance Source) ..................... –0.3V to 5.5V
VCC (Current Fed) .................................................. 25mA
VREF Output Current ................................ Self Regulated
Outputs (A, B, C, D, E, F) Current ..................... ±100mA
Operating Temperature Range (Note 5)
LTC1922E ........................................... – 40°C to 85°C
LTC1922I ............................................ – 40°C to 85°C
Storage Temperature Range ................. – 65°C to 125°C
Lead Temperature (Soldering, 10 sec).................. 300°C
SYNC
1
20 CT
RAMP
2
19 GND
CS
3
18 OUTA
COMP
4
17 OUTB
RLEB
5
16 OUTC
FB
6
15 VCC
SS
7
14 OUTD
PDLY
8
13 OUTE
SBUS
9
12 OUTF
ADLY 10
11 VREF
G PACKAGE
20-LEAD PLASTIC SSOP
LTC1922EG-1
LTC1922IG-1
LTC1922EN-1
LTC1922IN-1
N PACKAGE
20-LEAD PDIP
TJMAX = 125°C, θJA = 110°C/W (G)
TJMAX = 125°C,θJA = 62°C/W (N)
Consult factory for parts specified with wider operating temperature ranges.
ELECTRICAL CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at VCC = 9.5V, CT = 180pF, TA = TMIN to TMAX unless other wise noted.
SYMBOL
PARAMETER
CONDITIONS
UVLO
Undervoltage Lockout
Measured on VCC
UVHY
UVLO Hysteresis
Measured on VCC
ICCST
Start-Up Current
VCC = VUVLO – 0.3V
ICCRN
Operating Current
VSHUNT
Shunt Regulator Voltage
RSHUNT
MIN
TYP
MAX
UNITS
10.25
10.7
V
Input Supply
3.8
4.2
V
145
250
µA
4
7
mA
Current Into VCC = 10mA
10.2
10.8
V
Shunt Resistance
Current Into VCC = 7mA to 17mA
–1.5
2
Ω
DTHR
Delay Pin Threshold
ADLY and PDLY
SBUS = 1.5V
SBUS = 2.25V
1.38
2.08
1.50
2.25
1.62
2.42
V
V
DHYS
Delay Hysteresis Current
ADLY and PDLY
SBUS = 1.5V, ADLY/PDLY = 1.6V
1.1
1.3
1.45
mA
DTMO
Delay Time-Out
SBUS = 1.5V
SBUS = 2.25V
DZRT
Zero Delay Threshold
Measured on SBUS
●
Delay Blocks
600
900
3
4.15
ns
ns
5
V
Phase Modulator
ROS
RAMP Offset Voltage
Measured on COMP, RAMP = 0V
0.4
V
IRMP
RAMP Discharge Current
RAMP = 1V, COMP = 0V
30
50
mA
ISLP
Slope Compensation Current
Measured on CS, CT = 1.5V
CT = 3V
35
70
55
110
DCMX
Maximum Phase Shift
COMP = 4V
●
95
99.5
DCMN
Minimum Phase Shift
COMP = 0V
●
2
0.1
75
150
µA
µA
%
0.6
%
LTC1922-1
ELECTRICAL CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at VCC = 9.5V, CT = 180pF, TA = TMIN to TMAX unless other wise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
OSCT
Total Variation
VCC = 6.5V to 9.5V
236
277
319
kHz
OSCV
CT RAMP Amplitude
OSYT
SYNC Threshold
Measured on CT
3.6
3.85
4.2
V
Measured on SYNC
1.6
1.8
2.2
V
OSYW
Minimum SYNC Pulse Width
Measured at Outputs (Note 2)
OSYWX
Maximum SYNC Pulse Width
Measured on Outputs, CT = 180pF
OSOP
SYNC Output Pulse Width
Measured on SYNC, RSYNC = 5.1k
Oscillator
●
6
ns
1.3
170
µs
ns
Error Amplifier
VFB
FB Input Voltage
COMP = 2.5V (Note 3)
1.179
FBI
FB Input Range
Measured on FB (Note 4)
–0.3
1.204
AVOL
Open-Loop Gain
COMP = 1V to 3V (Note 3)
70
90
IIB
Input Bias Current
COMP = 2.5V (Note 3)
VOH
Output High
Load on COMP = –100µA
4.7
4.92
VOL
Output Low
Load on COMP = 100µA
ISOURCE
Output Source Current
COMP = 2.5V
– 400
– 800
µA
ISINK
Output Sink Current
COMP = 2.5V
3
7
mA
VREF
Initial Accuracy
TA = 25°C, Measured on VREF
4.925
5
5.075
V
REFTV
Total Variation
Line, Load and Temperature
4.9
5
5.1
V
REFLD
Load Regulation
Load on VREF = 100µA to 5mA
2
15
mV
REFLN
Line Regulation
VCC = 6.5V to 9.5V
0.1
10
mV
REFSC
Short-Circuit Current
VREF Shorted to GND
18
30
45
mA
OUTH(X)
Output High Voltage
IOUT(X) = –50mA
7.9
8.4
OUTL(X)
Output Low Voltage
IOUT(X) = 50mA
0.6
1
V
RHI(X)
Pull-Up Resistance
IOUT(X) = –50mA to –10mA
22
30
Ω
RLO(X)
Pull-Down Resistance
IOUT(X) = –50mA to –10mA
12
20
Ω
tr(X)
Rise Time
COUT(X) = 50pF
5
15
ns
tf(X)
Fall Time
COUT(X) = 50pF
5
15
ns
5
0.18
1.229
V
2.5
V
dB
50
nA
V
0.4
V
Reference
●
Outputs
V
Current Limit and Shutdown
CLPP
Pulse-by-Pulse Current Limit Threshold
Measured on CS
0.34
0.415
0.48
V
CLSD
Shutdown Current Limit Threshold
Measured on CS
0.55
0.64
0.73
V
SSI
Soft-Start Current
SS = 2.5V
7
12
17
µA
SSR
Soft-Start Reset Threshold
Measured on SS
0.7
0.4
0.1
V
FLT
FAULT Reset Threshold
Measured on SS
4.4
4.1
3.8
V
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: SYNC pulse width is valid from >20ns and <0.4 • (1/fOSC),
VSYNC = 0V to 5V.
Note 3: FB is driven by a servo loop amplifier to control VCOMP for these
tests.
Note 4: Set FB to –0.3V, 2.5 and insure that COMP does not phase invert.
Note 5: The LTC1922-1E is guaranteed to meet performance specifications
from 0°C to 85°C. Specification over the –40°C to 85°C operating
temperature range are assured by design, characterization and correlation
with statistical process controls. The LTC1922-1I is guaranteed and tested
over the – 40°C to 85°C operating temperature range.
3
LTC1922-1
U W
TYPICAL PERFOR A CE CHARACTERISTICS
Start-Up ICC vs VCC
TA = 25°C
TA = 25°C
CT = 180pF
270
VCC (V)
100
FREQUENCY (kHz)
10.25
150
ICC (µA)
280
10.50
200
10.00
9.50
0
2
6
4
8
10
10
0
VCC (V)
30
20
ISHUNT (mA)
40
240
– 60 – 40 – 20 0
20 40 60
TEMPERATURE (°C)
50
Leading Edge Blanking Time
vs RLEB
VREF vs IREF
5.05
TA = 25°C
300
TJ = 25°C
5.00
TJ = 85°C
VREF (V)
BLANK TIME (ns)
250
200
150
4.95
4.90
TJ = –40°C
100
4.85
50
4.80
0
0 10 20 30 40 50 60
RLEB (kΩ)
0
70 80 90 100
5
10
15 20 25
IREF (mA)
30
Error Amplifier Gain/Phase
GAIN (dB)
5.01
4.99
PHASE (DEG)
VREF (V)
5.00
4.98
4.97
– 60 – 40 – 20 0
20 40 60
TEMPERATURE (°C)
80
100
1922 • G03
4
40
35
1922 • G05
1922 • G04
VREF vs Temperature
TA = 25°C
100
80
60
40
20
0
–180
–270
–360
10
80
100
1922 • G03
1922 • G02
1922 • G01
350
260
250
9.75
50
0
Oscillator Frequency vs
Temperature
VCC vs ISHUNT
100
1k
10k
100k
FREQUENCY (Hz)
1M
10M
1922 • G07
LTC1922-1
U W
TYPICAL PERFOR A CE CHARACTERISTICS
Delay Hysteresis Current vs
Temperature
Start-Up ICC vs Temperature
1.278
150
1.276
140
120
110
100
90
80
120
1.274
5
35
65
TEMPERATURE (°C)
95
125
CT = 3.0V
110
1.272
1.270
1.268
1.266
1.264
1.262
100
90
80
70
CT = 1.5V
60
1.260
50
40
1.256
–55
–25
5
35
65
TEMPERATURE (°C)
95
125
–55
–25
5
35
65
TEMPERATURE (°C)
1922 • G11
1922 • G10
95
125
1922 • G12
Delay Pin Threshold vs
Temperature
VCC Shunt Voltage vs Temperature
10.5
2.4
ICC = 10mA
2.3
10.4
SBUS = 2.25V
2.2
THRESHOLD (V)
10.3
10.2
10.1
2.1
2.0
1.9
1.8
1.7
10.0
1.6
9.9
SBUS = 1.5V
1.5
9.8
–55
–25
5
35
65
TEMPERATURE (°C)
95
1.4
–55
125
–25
5
35
65
TEMPERATURE (°C)
1922 • G13
1.202
390
1.201
385
1.200
380
1.199
375
1.198
1.197
370
365
1.196
360
1.195
355
–25
5
35
65
TEMPERATURE (°C)
95
125
Ramp Offset Voltage vs
Temperature
FB Input Voltage vs Temperature
1.194
–55
95
1922 • G14
OFFSET (mV)
–25
SHUNT VOLTAGE (V)
70
–55
SBUS = 1.5V
1.258
FB VOLTAGE (V)
ICC (µA)
130
Slope Current vs Temperature
130
CURRENT (µA)
HYSTERESIS CURRENT (mA)
160
125
1922 • G15
350
–55
–25
5
35
65
TEMPERATURE (°C)
95
125
1922 • G16
5
LTC1922-1
U
U
U
PIN FUNCTIONS
SYNC (Pin 1): Synchronization Input/Output for the
Oscillator. Terminate SYNC with a 5.1k resistor to GND.
RAMP (Pin 2): Input to Phase Modulator Comparator. The
voltage on RAMP is internally level shifted by 400mV.
CS (Pin 3): Input to Current Limit Comparators, Output of
Slope Compensation Circuitry.
COMP (Pin 4): Error Amplifier Output, Input to Phase
Modulator.
RLEB (Pin 5): Timing Resistor for Leading Edge Blanking.
Use a 10k to 100k resistor to program from 40ns to 310ns
of leading edge blanking. A ±1% tolerance resistor is
recommended. Leading edge blanking may be defeated by
connecting RLEB to VREF.
FB (Pin 6): Error Amplifier Inverting Input. This is the
voltage feedback input for the LTC1922-1.
SS (Pin 7): Soft-Start/Restart Delay Circuitry Timing
Capacitor.
PDLY (Pin 8): Passive Leg Delay Circuit Input.
SBUS (Pin 9): Input (Bus) Voltage Sensing Input.
ADLY (Pin 10): Active Leg Delay Circuit Input.
6
VREF (Pin 11): 5V Reference Output. VREF is capable of
supplying up to 15mA to external circuitry. Bypass VREF
with a 1µF (minimum) ceramic capacitor to GND.
OUTF (Pin 12): 50mA Driver Output for Secondary Side
Current Doubler Synchronous Rectifier.
OUTE (Pin 13): 50mA Driver Output for Secondary Side
Current Doubler Synchronous Rectifier.
OUTD (Pin 14): 50mA Driver Output for Active Leg Low
Side.
VCC (Pin 15): Chip Power Supply Input, 10.3V Shunt
Regulator. Bypass VCC with a 0.1µF or larger ceramic
capacitor to GND.
OUTC (Pin 16): 50mA Driver Output for Active Leg High
Side.
OUTB (Pin 17): 50mA Driver Output for Passive Leg Low
Side.
OUTA (Pin 18): 50mA Driver Output for Passive Leg High
Side.
GND (Pin 19): All Voltages on the LTC1922-1 Are Referred
to GND.
CT (Pin 20): Timing Capacitor for Oscillator. Use ±5% or
better multilayer NPO ceramic for best results.
LTC1922-1
W
BLOCK DIAGRA
VCC
VREF
CT
SYNC
SBUS
15
11
20
1
9
5V
UVLO
SHUNT REG
10.25V “ON”
6V “0FF”
REF AND LDO
1.2V
ERROR
AMPLIFIER
FB 6
OSC
8 PDLY
–
1.2V
+
50k
COMP 4
PHASE
MODULATOR
Q
+
T
+
PASSIVE
DELAY
17 OUTB
QB
0.4V
RAMP 2
18 OUTA
–
14.9k
–
BLANK
VREF
QB
R
Q
S
13 OUTE
SYNC
RECTIFIER
DRIVE
LOGIC
12µA
SS 7
+
FAULT
LOGIC
R
–
600mV
SHUTDOWN
CURRENT LIMIT
RLEB 5
12 OUTF
16 OUTC
QB
S
ACTIVE
DELAY
14 OUTD
CS 3
BLANK
+
SLOPE
COMPENSATION
CT/R
10 ADLY
19
400mV
–
1922 • BD
GND
PULSE BY PULSE
CURRENT LIMIT
WU
W
TI I G DIAGRA
ACTIVE DELAY
PASSIVE DELAY
OUTA
OUTB
OUTC
OUTD
RAMP
COMP
CURRENT DOUBLER
OUTE
OUTF
NOTE: SHADED AREAS CORRESPOND TO POWER DELIVERY PULSES
1922 TD
7
LTC1922-1
U
OPERATIO
Phase Shift Full-Bridge PWM
5) Optimized current mode control architecture.
Conventional full-bridge switching power supply topologies are often employed for high power, isolated DC/DC
and off-line converters. Although they require two additional switching elements, substantially greater power and
higher efficiency can be attained for a given transformer
size compared to the more common single-ended forward
and flyback converters. These improvements are realized
since the full-bridge converter delivers power during both
parts of the switching cycle, reducing transformer core
loss and lowering voltage and current stresses. The fullbridge converter also provides inherent automatic transformer flux reset and balancing due to its bidirectional
drive configuration. As a result, the maximum duty cycle
range is extended, further improving efficiency. Soft switching variations on the full-bridge topology have been proposed to improve and extend its performance and
application. These zero voltage switching (ZVS) techniques exploit the generally undesirable parasitic elements present within the power stage. The parasitic
elements are utilized to drive near lossless switching
transitions for all of the external power MOSFETs.
Benefit: eliminates glue circuitry, less overshoot at startup, faster recovery from system faults.
LTC1922-1 phase shift PWM controller provides enhanced
performance and simplifies the design task required for a
ZVS phase shifted full-bridge converter. The primary
attributes of the LTC1922-1 as compared to currently
available solutions include:
1) Truly adaptive and accurate (DirectSense technology)
ZVS switching delays.
Benefit: higher efficiency, higher duty cycle capability,
eliminates external trim.
2) Internally generated drive signals for current doubler
synchronous rectifiers.
Benefit: eliminates external glue logic, drivers, optimal
timing for highest efficiency.
6) Proven reference circuits and design tools.
Benefit: substantially reduced learning curve, more time
for optimization.
As a result, the LTC1922-1 makes the ZVS topology
feasible for a wider variety of applications, including those
at lower power levels.
The LTC1922-1 controls four external power switches in
a full-bridge arrangement. The load on the bridge is the
primary winding of a power transformer. The diagonal
switches in the bridge connect the primary winding between the input voltage and ground every oscillator cycle.
The pair of switches that conduct are alternated by an
internal flip-flop in the LTC1922-1. Thus, the voltage
applied to the primary is reversed in polarity on every
switching cycle and each output drive signal is 1/2 the
frequency of the oscillator. The on-time of each driver
signal is slightly less that 50%. The actual percentage is
adaptively modulated by the LTC1922-1. The on-time
overlap of the diagonal switch pairs is controlled by the
LTC1922-1 phase modulation circuitry. (Refer to Block
and Timing Diagrams) This overlap sets the approximate
duty cycle of the converter. The LTC1922-1 driver output
signals (OUTA to OUTF) are optimized for interface with an
external gate driver IC or buffer. External power MOSFETs
A and C require high side driver circuitry, while B and D are
ground referenced and E and F are ground referenced but
on the secondary side of the isolation barrier. Methods for
providing drive to these elements are detailed in the data
sheet. The secondary voltage of the transformer is the
primary voltage divided by the transformer turns ratio.
Similar to a buck converter, the secondary square wave is
applied to an output filter inductor and capacitor to produce a well regulated DC output voltage.
3) Programmable (single resistor) leading edge blanking.
Benefit: prevents spurious operation, reduces external
filtering required on CS.
4) Programmable (single resistor) slope compensation.
Benefit: eliminates external glue circuitry.
8
Switching Transitions
The phase shifted full-bridge can be described by four
primary operating states. The key to understanding how
ZVS occurs is revealed by examining the states in detail.
LTC1922-1
U
OPERATIO
Each full cycle of the transformer has two distinct periods
in which power is delivered to the output, and two “freewheeling” periods. The two sides of the external bridge
have fundamentally different operating characteristics that
become important when designing for ZVS over a wide
load current range. The left bridge leg is referred to as the
“passive” leg, while the right leg is referred to as the
“active” leg. The following descriptions provide insight as
to why these differences exist.
risen to VIN, MOSFET MC is switched on by the LTC19221 DirectSense circuitry. The primary current␣ now flows
through the two high side MOSFETs (MA and MC). The
transformer’s secondary windings are electrically shorted
at this time since both ME and MF are “ON”. As long as
positive current flows in LO1 and LO2, the transformer
primary (magnetizing) inductance is also shorted through
normal transformer action. MA and MF turn off at the end
of State 2.
State 1 (Power Pulse 1)
State 3 (Passive Transition)
Referring to Figure 1, State 1 begins with MA, MD and MF
“ON” and MB, MC and ME “OFF.” During the simultaneous
conduction of MA and MD, the full input voltage is applied
across the transformer primary winding and following the
dot convention, VIN/N is applied to the left side of LO1
allowing current to increase in LO1. The primary current
during this period is approximately equal to the output
inductor current (LO1) divided by the transformer turns
ratio plus the transformer magnetizing current (VIN • tON/
LMAG). MD turns off and ME turns on at the end of State 1.
MA turns off when the oscillator timing period ends, i.e.,
the clock pulse toggles the internal flip-flop. At the instant
MA turns off, the voltage on the MA/MB junction begins to
decay towards the lower supply (GND). The energy available to drive this transition is limited to the primary leakage
inductance and added commutating inductance which
have (IMAG + IOUT/2N) flowing through them initially. The
magnetizing and output inductors don’t contribute any
energy because they are effectively shorted as mentioned
previously, significantly reducing the available energy.
This is the major difference between the active and passive
transitions. If the energy stored in the leakage and commutating inductance is greater than the capacitive energy,
the transition will be completed successfully. During the
transition, an increasing reverse voltage is applied to the
leakage and commutating inductances, helping the overall
primary current to decay. The inductive energy is thus
resonantly transferred to the capacitive elements, hence,
the term passive or resonant transition. Assuming there is
sufficient inductive energy to propel the bridge leg to
GND, the time required will be approximately equal to
π • √LC/2. When the voltage on the passive leg nears GND,
MOSFET MB is commanded “ON” by the LTC1922-1
DirectSense circuitry. Current continues to increase in the
leakage and external series inductance which is opposite
in polarity to the reflected output inductor current. When
this current is equal in magnitude to the reflected output
current, the primary current reverses direction, the opposite secondary winding becomes forward biased and a
new power pulse is initiated. The time required for the
current reversal reduces the effective maximum duty cycle
State 2 (Active Transition and Freewheel Interval)
MD turns off when the phase modulator comparator
transitions. At this instant, the voltage on the MD/MC
junction begins to rise towards the applied input voltage
(VIN). The transformer’s magnetizing current and the
reflected output inductor current propels this action. The
slew rate is limited by MOSFET MC and MD’s output
capacitance (COSS), snubbing capacitance and the transformer interwinding capacitance. The voltage transition
on the active leg from the ground reference point to VIN will
always occur, independent of load current as long as
energy in the transformer’s magnetizing and leakage inductance is greater than the capacitive energy. That is,
1/2 • (LM + LI) • IM2 > 1/2 • 2 • COSS • VIN2 — the worst case
occurs when the load current is zero. This condition is
usually easy to meet. The magnetizing current is virtually
constant during this transition because the magnetizing
inductance has positive voltage applied across it throughout the low to high transition. Since the leg is actively
driven by this “current source,” it is called the active or
linear transition. When the voltage on the active leg has
9
LTC1922-1
U
OPERATIO
.and must be considered when specifying the power transformer. If ZVS is required over the entire range of loads, a
small commutating inductor is added in series with the
primary to aid with the passive leg transition, since the
leakage inductance alone is usually not sufficient and
predictable enough to guarantee ZVS over the full load
range.
State 1.
State 4 (Power Pulse 2)
During power pulse 2, current builds up in the primary
winding in the opposite direction as power pulse 1. The
primary current consists of reflected output inductor
current and current due to the primary magnetizing inductance. At the end of State 4, MOSFET MC turns off and an
active transition, essentially similar to State 2, but opposite in direction (high to low) takes place.
POWER PULSE 1
VIN
VOUT
L1
MA
MC
MB
MD
N:1
LOAD
L2
+
MF
ME
IP ≈ IL01/N + (VIN • TOVL)/LMAG
PRIMARY AND
SECONDARY SHORTED
State 2.
ACTIVE
TRANSITION
MA
FREEWHEEL
INTERVAL
MC
VOUT
MA
MC
LOAD
MB
MD
MB
MD
MF
State 3.
PASSIVE
TRANSITION
MA
MC
MB
MD
State 4.
MA
POWER PULSE 2
VOUT
MC
LOAD
MB
+
MD
MF
ME
1922 F01
Figure 1. ZVS Operation
10
ME
LTC1922-1
U
OPERATIO
Zero Voltage Switching (ZVS)
Adaptive Mode
A lossless switching transition requires that the respective
full-bridge MOSFETs be switched to the “ON” state at the
exact instant their drain to source voltage is zero. Delaying
the turn-on results in lower efficiency due to circulating
current flowing in the body diode of the primary side
MOSFET rather than its low resistance channel. Premature
turn-on produces hard switching of the MOSFETs, increasing noise and power dissipation. Previous solutions
have attempted to meet these requirements with fixed or
first order (linear) variable open-loop time delays. Openloop methods typically set the turn-on delay to the worst
case longest bridge transition time expected plus the
tolerances of all the internal and external delay timing
circuitry. These error tolerances can be quite significant,
while the optimal transition times over the load current
range vary nonlinearly. In a volume production environment, these factors can necessitate an external trim to
guarantee ZVS operation, adding cost to the final product.
An additional side effect of longer than required delays is
a decrease in the effective maximum duty cycle. Reduced
duty cycle range can mandate a lower transformer turns
ratio, impacting efficiency or requiring a lower switching
frequency, impacting size.
The LTC1922-1 is configured for adaptive delay sensing
with three pins, ADLY, PDLY and SBUS. ADLY and PDLY
sense the active and passive delay legs respectively via a
voltage divider network as shown in Figure 2.
LTC1922-1 Adaptive Delay Circuitry
The LTC1922-1 addresses the issue of nonideal switching
delays with novel DirectSense circuitry that intelligently
monitors both the input supply and instantaneous bridge
leg voltages, and commands a switching transition when
the expected zero voltage condition is reached. In effect,
the LTC1922-1 “closes the loop” on the ZVS turn-on delay
requirements. DirectSense technology provides optimal
turn-on delay timing, regardless of input voltage, output
load, or component tolerances and greatly simplifies the
power supply design process. The DirectSense technique
requires only a simple voltage divider sense network to
implement. If there is not enough energy to fully commutate the bridge leg to a ZVS condition, the LTC1922-1
automatically overrides the DirectSense circuitry and forces
a transition. The LTC1922-1 delay circuitry can also be
overridden, by tying SBUS to VREF.
VIN
A
R2
C
ADLY
SBUS
R5
R6
PDLY
B
R1
D
R3
1k
R4
1k
RCS
1922 F02
Figure 2. Adaptive Mode
The threshold voltage on PDLY and ADLY for both the
rising and falling transitions is set by the voltage on SBUS.
A buffered version of this voltage is used as the threshold
level for the internal DirectSense circuitry. At nominal VIN,
the voltage on SBUS is set to 1.5V by an external voltage
divider between VIN and GND, making this voltage directly
proportional to VIN. The LTC1922-1 DirectSense circuitry
uses this characteristic to zero voltage switch all of the
external power MOSFETs, independent of input voltage.
ADLY and PDLY are connected through voltage dividers to
the active and passive bridge legs respectively. The lower
resistor in the divider is set to 1k. The upper resistor in the
divider is divided into one, two or three equal value
resistors to reduce its overall capacitance. In off-line
applications, this is usually required anyway to stay within
the maximum voltage ratings of the resistors. One or two
resistor segments will work for most nominal 48V or lower
VIN applications.
To set up the ADLY and PDLY resistors, first determine at
what drain to source voltage to turn-on the MOSFETs.
Finite delays exist between the time at which the LTC1922-1
controller output transitions, to the time at which the
power MOSFET switches on due to MOSFET turn on delay
and external driver circuit delay. Ideally, we want the
power MOSFET to switch at the instant there is zero volts
across it. By setting a threshold voltage for ADLY and
11
LTC1922-1
U
OPERATIO
PDLY corresponding to several volts across the MOSFET,
the LTC1922-1 can “anticipate” a zero voltage VDS and
signal the external driver and switch to turn-on. The
amount of anticipation can be tailored for any application
by modifying the upper divider resistor(s). The LTC1922-1
DirectSense circuitry sources a trimmed current out of
PDLY and ADLY after a low to high level transition occurs.
This provides hysteresis and noise immunity for the PDLY
and ADLY circuitry, and sets the high to low threshold on
ADLY or PDLY to nearly the same level as the low to high
threshold, thereby making the upper and lower MOSFET
VDS switch points virtually identical, independent of VIN.
to VCC as well as signaling that the chip’s bias voltage is
sufficient to begin switching operation (under voltage
lockout). With its typical 10.2V turn-on voltage and 4.2V
UVLO hysteresis, the LTC1922-1 is tolerant of loosely
regulated input sources such as an auxiliary transformer
winding. The VCC shunt is capable of sinking up to 25mA
of externally applied current. The UVLO turn-on and turnoff thresholds are derived from an internally trimmed
reference making them extremely accurate. In addition,
the LTC1922-1 exhibits very low (145µA typ) start-up
current that allows the use of 1/8W to 1/4W trickle charge
start-up resistors.
Example: VIN = 48V nominal (36V to 72V)
The trickle charge resistor should be selected as follows:
1. Set up SBUS: 1.5V is desired on SBUS with VIN = 48V.
Set divider current to 100µA.
RSTART(MAX) = VIN(MIN) – 10.7V/250µA
R1 = 1.5V/100µA = 15k.
Adding a small safety margin and choosing standard
values yields:
R2 = (48V – 1.5V)/100µA = 465k.
APPLICATION
VIN RANGE
RSTART
DC/DC
36V to 72V
100k
Off-Line
85V to 270VRMS
430k
390VDC
1.4M
An optional small capacitor (0.001µF) can be added
across R1 to decouple noise from this input.
2. Set up ADLY and PDLY: 7V of “anticipation” are required
in this circuit to account for the delays of the external
MOSFET driver and gate drive components.
R3, R4 = 1k, sets a nominal 1.5mA in the divider
chain at the threshold.
R5, R6 = (48V – 7V – 1.5V)/1.5mA = 26.3k,
use (2) equal 13k segments.
PFC Preregulator
VCC should be bypassed with a 0.1µF to 1µF multilayer
ceramic capacitor to decouple the fast transient currents
demanded by the output drivers and a bulk tantalum or
electrolytic capacitor to hold up the VCC supply before the
bootstrap winding, or an auxiliary regulator circuit takes
over.
CHOLDUP = (ICC + IDRIVE) • tDELAY/3.8V
(minimum UVLO hysteresis)
Zero Delay Mode
The LTC1922-1 provides the flexibility through the SBUS
pin to disable the DirectSense delay circuitry. See Figure␣ 3
for details.
Regulated bias supplies as low as 7V can be utilized to
provide bias to the LTC1922-1. Refer to Figure 4 for
various bias supply configurations.
VREF
VIN
SBUS
12V ±10%
VBIAS < VUVLO
ADLY
PDLY
1922 F03
1.5k
1N5226
3V
1N914
RSTART
+
Figure 3. Zero Delays
0.1µF
0.1µF
CHOLD
Powering the LTC1922-1
The LTC1922-1 utilizes an integrated VCC shunt regulator
to serve the dual purposes of limiting the voltage applied
12
VCC
VCC
Figure 4. Bias Configurations
1922 F04
LTC1922-1
U
OPERATIO
Off-Line Bias Supply Generation
If a regulated bias supply is not available to provide VCC
voltage to the LTC1922-1 and supporting circuitry, one
must be generated. Since the power requirement is small,
approximately 1W, and the regulation is not critical, a
simple open-loop method is usually the easiest and lowest
cost approach. One method that works well is to add a
winding to the main power transformer, and post regulate
the resultant square wave with an L-C filter (see Figure␣ 5a).
The advantage of this approach is that it maintains decent
regulation as the supply voltage varies, and it does not
require full safety isolation from the input winding of the
transformer. Some manufacturers include a primary winding for this purpose in their standard product offerings as
well. A different approach is to add a winding to the output
inductor and peak detect and filter the square wave signal
(see Figure 5b). The polarity of this winding is designed so
that the positive voltage square wave is produced while the
output inductor is freewheeling. An advantage of this
technique over the previous is that it does not require a
separate filter inductor and since the voltage is derived
from the well-regulated output voltage, it is also well
controlled. One disadvantage is that this winding will
require the same safety isolation that is required for the
main transformer. Another disadvantage is that a much
larger VCC filter capacitor is needed, since it does not
VIN
2k
+
0.1µF
CHOLD
1922 F05a
*OPTIONAL
Figure 5a. Auxiliary Winding Bias Supply
VIN
VOUT
LOUT
RSTART
ISO BARRIER
Programming the LTC1922-1 Oscillator
The high accuracy LTC1922-1 oscillator circuit provides
flexibility to program the switching frequency, slope compensation, and synchronization with minimal external
components. The LTC1922-1 oscillator circuitry produces
a 3.8V peak-to-peak amplitude ramp waveform on CT and
a narrow pulse on SYNC that can be used to synchronize
other PWM chips. Typical maximum duty cycles of 99%
are obtained at 300kHz and 97% at 1MHz. The large
amplitude ramp provides a high degree of noise margin. A
compensating slope current is derived from the oscillator
ramp waveform and sourced out of CS.
The desired amount of slope compensation is selected
with single external resistor (or no resistor), if not required. A capacitor to GND on CT programs the switching
frequency. The CT ramp discharge current is internally set
to a high value (>10mA). The dedicated SYNC I/O pin easily
achieves synchronization. The LTC1922-1 can be set up to
either synchronize other PWM chips or be synchronized
by another chip or external clock source. The 1.8V SYNC
threshold allows the LTC1922-1 to be synchronized directly from all standard 3V and 5V logic families.
Design Procedure:
VCC
RSTART
15V*
generate a voltage as the output is first starting up, or
during short-circuit conditions.
+
1. Choose CT for the desired oscillator frequency. The
switching frequency selected must be consistent with the
power magnetics and output power level. This is detailed
in the Transformer Design section. In general, increasing
the switching frequency will decrease the maximum achievable output power, due to limitations of maximum duty
cycle imposed by transformer core reset and ZVS. Remember that the output frequency is 1/2 that of the
oscillator.
CT = 1/(20k • fOSC)
Example: Desired fOSC = 330kHz
0.1µF
VCC
CHOLD
1922 F05b
Figure 5b. Output Inductor Bias Supply
CT = 1/(20k • 330kHz) = 152pF, choose closest standard
value of 150pF. A 5% or better tolerance multilayer NPO
or X7R ceramic capacitor is recommended for best
performance.
13
LTC1922-1
U
OPERATIO
2. The LTC1922-1 can either synchronize other PWMs, or
be synchronized to an external frequency source or PWM
chip. See Figure 6 for details.
CT OF SLAVE(S) IS
1.25 CT OF MASTER.
LTC1922-1
CT
5.1k
MASTER
CT
SYNC
CT
5.1k
SYNC
CT
LTC1922-1
1k
1k
SYNC
•
•
5.1k
•
UP TO
5 SLAVES
LTC1922-1
CT
CT
(33µA/V(CT)). Thus, at the peak of CT, this current is
approximately 125µA and is output from the CS pin. A
resistor connected between CS and the external current
sense resistor sums in the required amount of slope
compensation. The value of this resistor is dependent on
several factors including minimum VIN, VOUT, switching
frequency, current sense resistor value and output inductor value. An illustrative example with the design equation
is provided below.
Example: VIN = 36V to 72V
SLAVES
VOUT = 3.3V
1922 F06a
Figure 6a. SYNC Output (Master Mode)
IOUT = 40A
L = 2.2µH
AMPLITUDE > 1.8V
12.5ns < PW < 0.4/ƒ
EXTERNAL
FREQUENCY
SOURCE
1k
SYNC
5.1k
LTC1922-1
CT
Transformer turns ratio (N) = VIN(MIN) • DMAX/
VOUT␣ =␣ 3
RCS = 0.025Ω
CT
1922 F06b
fSW = 300kHz, i.e., transformer f = fSW/2 = 150kHz
Figure 6b. SYNC Input from an External Source
RSLOPE = VO • RCS/(2 • L • fT • 125µA • N) = 3.3V • 0.025/
(2 • 2.2µA • 100k • 125µA • 3)
3. Slope compensation is required for most peak current
mode controllers in order to prevent subharmonic oscillation of the current control loop. In general, if the system
duty cycle exceeds 50% in a fixed frequency, continuous
current mode converter, an unstable condition exists
within the current control loop. Any perturbation in the
current signal is amplified by the PWM modulator resulting in an unstable condition. Some common manifestations of this include alternate pulse nonuniformity and
pulse width jitter. Fortunately, this can be addressed by
adding a corrective slope to the current sense signal or by
subtracting the same slope from the current command
signal (error amplifier output). In theory, the current
doubler output configuration does not require slope compensation since the output inductor duty cycles only
approach 50%. However, transient conditions can momentarily cause higher duty cycles and therefore, the
possibility for unstable operation. The exact amount of
required slope compensation is easily programmed by the
LTC1922-1 with the addition of a single external resistor
(see Figure 7). The LTC1922-1 generates a current that is
proportional to the instantaneous voltage on C T ,
RSLOPE = 500Ω, choose the next higher standard value
to account for tolerances in ISLOPE, RCS, N and L.
14
LTC1922-1
CT
I=
33k
V(CT)
33k
BRIDGE
CURRENT
CS
RSLOPE
ADDED
SLOPE
CURRENT SENSE
WAVEFORM
RCS
1922 F07
Figure 7. Slope Compensation Circuitry
Current Sensing and Overcurrent Protection
Current sensing provides feedback for the current mode
control loop and protection from overload conditions. The
LTC1922-1 is compatible with either resistive sensing or
current transformer methods. Internally connected to the
LTC1922-1 CS pin are two comparators that provide
pulse-by-pulse and overcurrent shutdown functions respectively. (See Figure 8)
LTC1922-1
U
OPERATIO
PULSE BY PULSE
CURRENT LIMIT
φMOD
+
Q
S Q
S
–
R
OVERLOAD
CURRENT LIMIT
+
S Q
–
UVLO
ENABLE
4.1V
R
12µA
SS
0.4V
+
600mV
PWM
LOGIC
–
RCS
400mV
Q
H = SHUTDOWN
OUTPUTS
UVLO
ENABLE
+
CS
PWM
LATCH
CSS
–
Q
1922 F08
Figure 8. Current Sense/Fault Circuitry Detail
The pulse-by-pulse comparator has a 400mV nominal
threshold, which can reduce sense resistor losses by 67%
compared to previous solutions. This corresponds to 3W
in a 200W, 48V to 3.3V converter. If the 400mV threshold
is exceeded, the PWM cycle is terminated. The overcurrent
comparator is set approximately 50% higher than the
pulse-by-pulse level. If the current signal exceeds this
level, the PWM cycle is terminated, the soft-start capacitor
is quickly discharged and a soft-start cycle is initiated. If
the overcurrent condition persists, the LTC1922-1 halts
PWM operation and waits for the soft-start capacitor to
charge up to approximately 4V before a retry is allowed.
The soft-start capacitor is charged by an internal 12µA
current source. If the fault condition has not cleared when
soft-start reaches 4V, the soft-start pin is again discharged and a new cycle is initiated. This is referred to as
hiccup mode operation. In normal operation and under
most abnormal conditions, the pulse-by-pulse comparator is fast enough to prevent hiccup mode operation. In
severe cases, however, with high input voltage, very low
RDS(ON) MOSFETs and a shorted output, or with saturating magnetics, the overcurrent comparator provides a
means of protecting the power converter.
Leading Edge Blanking
The LTC1922-1 provides programmable leading edge
blanking to prevent nuisance tripping of the current sense
circuitry. Although the ZVS full-bridge topology is somewhat more immune to leading edge noise spikes than
other types of converters, they are not totally eliminated.
Leading edge blanking relieves the filtering requirements
for the CS pin, greatly improving the response to real
overcurrent conditions. It also allows the use of a ground
referenced current sense resistor or transformer(s), further simplifying the design. With a single 10k to 100k
resistor from RLEB to GND, blanking times of approximately 40ns to 320ns are programmed. If not required,
connecting RLEB to VREF can disable leading edge blanking. Keep in mind that the use of leading edge blanking will
set a minimum linear control range for the phase modulation circuitry.
Resistive Sensing
A resistor connected between input common and the
sources of MB and MD is the simplest, fastest and most
accurate method of current sensing for the full-bridge
converter. This is the preferred method for low to moderate power levels. A graph of resistive sense power losses
vs output power is shown Figure 9. The sense resistor
should be chosen such that the maximum rated output
current for the converter can be delivered at the lowest
expected VIN. Use the following formula to calculate the
optimal value for RCS.
15
LTC1922-1
U
OPERATIO
POWER LOSS (W)
2.0
RS = 0.025
1.8 VIN = 48V
VO = 3.3V
1.6
LO = 2.2µH
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
5
10 15 20 25 30
OUTPUT CURRENT (A)
35
40
1922 • F09
Figure 9. RSENSE Power Loss vs IOUT
If RAMP and CS are connected together:
RCS =
0.4V – (125µA • RSLOPE)
IP (PEAK)
IP (PEAK) =
IO(MAX)
+
VIN(MAX) • 2 • DMIN
LMAG • f CLK
2 • N • EFF
VO (1 – DMIN )
LOUT • f CLK• N
+
where: N = Transformer turns ratio
If RAMP and CS are separated
RCS
0.4V
=
IP (PEAK)
include, higher cost and complexity, lower accuracy, core
reset/max duty cycle limitations and lower speed. Nevertheless, for very high power applications, this method is
preferred. The sense transformer primary is placed in the
same location as the ground referenced sense resistor, or
between the upper MOSFET drains in the (MA, MC) and
VIN. The advantage of the high side location is a greater
immunity to leading edge noise spikes, since gate charge
current and reflected rectifier recovery current are largely
eliminated. Figure 10 illustrates a typical current sense
transformer based sensing scheme. RS in this case is
calculated the same as in the resistive case, only its value
is increased by the sense transformer turns ratio. At high
duty cycles, it may become difficult or impossible to reset
the current transformer. This is because the required
transformer reset voltage increases as the available time
for reset decreases to equalize the (volt • seconds) applied.
The interwinding capacitance and secondary inductance
of the current sense transformer form a resonant circuit
that limits the dV/dT on the secondary of the CS transformer. This in turn limits the maximum achievable duty
cycle for the CS transformer. Attempts to operate beyond
this limit will cause the transformer core to “walk” and
eventually saturate, opening up the current feedback loop.
Common methods to address this limitation include:
1. Reducing the maximum duty cycle by lowering the
power transformer turns ratio.
2. Reducing the switching frequency of the converter.
3. Employ external active reset circuitry.
4. Using two CS transformers summed together.
Current Transformer Sensing
A current sense transformer can be used in lieu of resistive
sensing with the LTC1922-1. Current sense transformers
are available in many styles from several manufacturers.
A typical sense transformer for this application will use a
1:50 turns ratio (N), so that the sense resistor value is N
times larger, and the secondary current N times smaller
than in the resistive sense case. Therefore, the sense
resistor power loss is about N times less with the transformer method, neglecting the transformers core and
copper losses. The disadvantages of this approach
16
5. Choose a CS transformer optimized for high frequency
applications.
MD
SOURCE
MB
SOURCE
RSLOPE
N:1
RAMP
RS
CURRENT
TRANSFORMER
CS
OPTIONAL
FILTERING
Figure 10. Current Transformer Sense Circuitry
1922 F10
LTC1922-1
U
OPERATIO
Phase Modulator
(MA-MD or MB-MC) conduct and cause current in an
output inductor to increase. This current is seen on the
primary of the power transformer divided by the turns
ratio. Since the current sense resistor is connected
between GND and the two bottom bridge transistors, a
voltage proportional to the output inductor current will be
seen across RSENSE. The high side of RSENSE is also
connected to RAMP and CS, usually through a small
resistor (RSLOPE). When the voltage on RAMP/CS exceeds
either COMP/5.2 – 400mV, or 400mv, the overlap conduction period will terminate. During normal operation, the
attenuated COMP voltage will determine the RAMP/CS trip
point. During start-up, or slewing conditions following a
large load step, the 400mV CS threshold will terminate the
cycle, as COMP will be driven high, such that the attenuated version exceeds the 400mV threshold. In extreme
conditions, the 600mV threshold on CS will be exceeded,
invoking a soft-start/restart cycle.
The LTC1922-1 phase modulation control circuitry is
comprised of the phase modulation comparator and logic,
the error amplifier, and the soft-start amplifier (see
Figure␣ 11). Together, these elements develop the required
phase overlap (duty cycle) required to keep the output
voltage in regulation. In isolated applications, the sensed
output voltage error signal is fed back to COMP across the
input to output isolation boundary by an optical coupler
and shunt reference/error amplifier (LT®1431) combination. The FB pin is connected to GND, forcing COMP high.
The collector of the optoisolator is connected to COMP
directly. The voltage COMP is internally attenuated by the
LTC1922-1. The attenuated COMP voltage provides one
input to the phase modulation comparator. This is the
current command. The other input to the phase modulation comparator is the RAMP voltage, level shifted by
approximately 400mV. This is the current loop feedback.
During every switching cycle, alternate diagonal switches
FB
+
1.2V
TOGGLE
F/F
Q
ERROR
AMPLIFIER
–
50k
PHASE
MODULATION
COMPARATOR
COMP
VREF
SS
Q
–
PHASE
MODULATION
LOGIC
+
S Q
+
12µA
+
A
CLK
CLK
400mV
SOFT-START
AMPLIFIER
–
B
C
D
R
FROM
CURRENT
LIMIT
COMPARATOR
–
14.9k
RLEB
RAMP
BLANKING
Q S
R
CLK
1922 F11
Figure 11. Phase Modulation Circuitry
17
LTC1922-1
U
OPERATIO
Selecting the Power Stage Components
Perhaps the most critical part of the overall design of the
converter is selecting the power MOSFETs, transformer,
inductors and filter capacitors. Tremendous gains in efficiency, transient performance and overall operation can
be obtained as long as a few simple guidelines are followed
with the phase shifted full-bridge topology.
Power Transformer
This guide is aimed at selecting readily available standard
“off the shelf” transformers. The basic requirements,
however, apply to custom transformer designs as well.
Switching frequency, core material characteristics, series
resistance and input/output voltages all play an important
role in transformer selection. Close attention also needs to
be paid to leakage and magnetizing inductances as they
play an important role in how well the converter will
achieve ZVS. Planar magnetics are very well suited to
these applications because of their excellent control of
these parameters.
Turns Ratio
impact on efficiency. Other factors to consider are switching frequency and required maximum duty cycle. A lower
value of magnetizing inductance will require a longer time
to reset the core, cutting into the available duty cycle
range. As switching frequencies increase, this becomes
more significant. In general, the magnetizing inductance
value should be the lowest value required in order to
achieve the necessary maximum duty cycle at the chosen
switching frequency. Output inductor value determines
the magnitude of output ripple current and therefore the
ripple voltage along with the output capacitors. Generally
speaking, the output inductance should be minimized as
much as possible in order to improve transient response.
In addition, output capacitance ESR should be minimized
as much as possible. Using the equations below, plug in
the manufacturers magnetizing inductance value and a
“starting value” of commutating inductance (1% of LMAG)
to verify that a sufficient max duty cycle can be achieved
at the desired switching frequency. Next, use equation (2)
to determine what the absolute minimum required LCOM is
to guarantee ZVT over the entire load range. One or two
iterations may be required in order to arrive at the final
selections.
The required turns ratio for a current doubler secondary is
given below. Depending on the magnetics selected, this
value may need to be reduced slightly.
MAX DC vs LCOM at fSW
Turns ratio formula:
MAX DC ≥
N = 2•
2 – f SW • TR
;
2
(1)
VIN(MIN) • DMAX
VOUT
where:
VIN(MIN) = Minimum VIN for operation
DMAX = Maximum duty cycle of controller
where:
TR = transformer reset time (worst case)
=
IO(MAX) • f SW • LMAG + VIN • 2 • D • N  LCOM + LL 


f SW • LMAG • N
VIN


Magnetizing, Output, and Leakage Inductors
A lower value of magnetizing and output inductance will
improve the ability of the converter to achieve ZVS over the
full range of loads and reduce the size of the external
commutating inductor. One of the trade-offs is increased
primary referred ripple current which has a small negative
18
LCOM vs ZVS vs Load
2
LCOM + LL =
2
4 / 3 C OSS • LMAG • f SW
2 • D2
(2)
LTC1922-1
U
OPERATIO
where:
COSS = MOSFET D-S capacitance
lMAG = magnetizing inductance
fSW = switching frequency
D = duty cycle
LL = leakage inductance
For a 48V to 3.3V/5V, 200W converter, the following
values were derived:
fSW
LMAG
LCOM
LOUT
: 300kHz
: 100µH
: 0.9µH
: 2.2µH
Turns Ratio (N) = 2.5
Output Capacitors
Output capacitor selection has a dramatic impact on ripple
voltage, dynamic response to transients and stability.
Capacitor ESR along with output inductor ripple current
will determine the peak-to-peak voltage ripple on the
output. The current doubler configuration is advantageous because it has inherent ripple current reduction.
The dual output inductors deliver current to the output
capacitor 180 degrees out of phase, in effect, partially
canceling each other’s ripple current. This reduction is
maximized at high duty cycle and decreases as the duty
cycle reduces. This means that a current doubler converter requires less output capacitance for the same
performance as a conventional converter. By determining
the minimum duty cycle for the converter, worse-case
VOUT ripple can be derived by the formula given below.
VORIPPLE = IRIPPLE • ESR =
VO • ESR
(1 – D)(1 – 2D)
LO • 2 • f SW
where:
D
= minimum duty cycle
fSW = oscillator frequency
LO = output inductance
ESR = output capacitor series resistance
The amount of bulk capacitance required is usually system
dependent, but has some relationship to output inductance value, switching frequency, load power and dynamic
load characteristics. Polymer electrolytic capacitors are
the preferred choice for their combination of low ESR,
small size and high reliability. For less demanding applications, or those not constrained by size, aluminum electrolytic capacitors are commonly applied. Most
DC/DC converters in the 100kHz to 300kHz range use 20µF
to 25µF of bulk capacitance per watt of output power.
Converters switching at higher frequencies can usually
use less bulk capacitance. In systems where dynamic
response is critical, additional high frequency capacitors,
such as ceramics, can substantially reduce voltage transients,
Power converter stability is, to a large extent, determined
by the choice of output capacitor. A zero in the converter’s
transfer function is given by 1/(2π • ESR • CO). Aluminum
electrolytic ESR is highly variable with temperature, increasing by about 4× at cold temperatures, making the
ESR zero frequency highly variable. Polymer electrolytic
ESR is essentially flat with temperature. This characteristic simplifies loop compensation and allows for a much
faster responding power supply compared to one with
aluminum electrolytic capacitors. Specific details on loop
compensation are given in the Compensation section of
the data sheet.
Power MOSFETs
The full-bridge power MOSFETs should be selected for
their RDS(ON) and BVDSS ratings. Select the lowest BVDSS
rated MOSFET available for a given input voltage range
leaving at least a 20% voltage margin. Conduction losses
are directly proportional to RDS(ON). Since the full-bridge
has two MOSFETs in the power path most of the time,
conduction losses are approximately equal to:
2 • RDS(ON) • I2, where I = IO/2N
Switching losses in the MOSFETs are dominated by the
power required to charge their gates, and turn-on and
turn-off losses. At higher power levels, gate charge power
is seldom a significant contributor to efficiency loss. ZVS
operation virtually eliminates turn-on losses. Turn-off
losses are reduced by the use of an external drain to source
19
LTC1922-1
U
OPERATIO
snubber capacitor and/or a very low resistance turn-off
driver. If synchronous rectifier MOSFETs are used on the
secondary, the same general guidelines apply. Keep in
mind, however, that the BVDSS rating needed for these can
be greater than VIN(MAX)/N, depending on how well the
secondary is snubbed. Without snubbing, the secondary
voltage can ring to levels far beyond what is expected due
to the resonant tank circuit formed between the secondary
leakage inductance and the COSS (output capacitance) of
the synchronous rectifier MOSFETs.
Switching Frequency Selection
Closing the Feedback Loop
Closing the feedback loop with the full-bridge converter
involves identifying where the power stage and other
system poles/zeroes are located and then designing a
compensation network around the converters error amplifier to shape the frequency response to insure adequate
phase margin and transient response. Additional modifications will sometimes be required in order to deal with
parasitic elements within the converter that can alter the
feedback response. The compensation network will vary
depending on the load current range and the type of output
capacitors used. In isolated applications, the compensation network is generally located on the secondary side of
the power supply, around the error amplifier of the
optocoupler driver, usually an LT1431or equivalent. In
nonisolated systems, the compensation network is located around the LTC1922-1’s error amplifier.
Unless constrained by other system requirements, the
power converter’s switching frequency is usually set as
high as possible while staying within the desired efficiency
target. The benefits of higher switching frequencies are
many including smaller size, weight and reduced bulk
capacitance. In the full-bridge phase shift converter, these
principles are generally the same with the added complication of maintaining zero voltage transitions, and therefore, higher efficiency. ZVS is achieved in a finite time
during the switching cycle. During the ZVS time, power is
not delivered to the output; the act of ZVS reduces the
maximum available duty cycle. This reduction is proportional to maximum output power since the parasitic capacitive element (MOSFETs) that increase ZVS time get
larger as power levels increase. This implies an inverse
relationship between output power level and switching
frequency. Table 1 displays recommended maximum
switching frequency vs power level for a 30V/75V in to
3.3V/5V out converter. Higher switching frequencies can
be used if the input voltage range is limited, the output
voltage is lower and/or lower efficiency can be tolerated.
In current mode control, the dominant system pole is
determined by the load resistance (VO/IO) and the output
capacitor 1/(2π • RO • CO). The output capacitors ESR
1/(2π • ESR • CO) introduces a zero. Excellent DC line and
load regulation can be obtained if there is high loop gain at
DC. This requires an integrator type of compensator
around the error amplifier. A procedure is provided for
deriving the required compensation components. More
complex types of compensation networks can be used to
obtain higher bandwidth if necessary.
Table 1.Switching Frequency vs Power Level
Step 2. Calculate ESR zero location:
20
<50W
600kHz
<100W
450kHz
<200W
300kHz
<500W
200kHz
<1kW
150kHz
<2kW
100kHz
Step 1. Calculate location of minimum and maximum
output pole:
FP1(MIN) = 1/(2π • RO(MAX) • CO)
FP1(MAX) = 1/(2π • RO(MIN) • CO)
FZ1 = 1/(2π • RESR • CO)
Step 3. Calculate the feedback divider gain:
RB/(RB + RT) or VREF/VOUT
If Polymer electrolytic output capacitors are used, the ESR
zero can be employed in the overall loop compensation
and optimum bandwidth can be achieved. If aluminum
electrolytics are used, the loop will need to be rolled off
prior to the ESR zero frequency, making the loop response
LTC1922-1
U
OPERATIO
slower. A linearized SPICE macromodel of the control loop
is very helpful tool to quickly evaluate the frequency
response of various compensation networks.
Polymer Electrolytic (see Figure 12) 1/(2πCCRI) sets a
low frequency pole. 1/(2πCCRF) sets the low frequency
zero. The zero frequency should coincide with the worstcase lowest output pole frequency. The pole frequency
and mid frequency gain (RF/RI) should be set such so that
the loop crosses over zero dB with a –1 slope at a
frequency lower than (fSW/8). Use a bode plot to graphically display the frequency response. An optional higher
frequency pole set by CP2 and Rf is used to attenuate
switching frequency noise.
VOUT
VOUT
OPTIONAL
CC
Rf
CO
RI
REF
RL
–
ESR
COMP
OPTO
CP2
RD
2.5V
COLL
+
LT1431 OR EQUIVALENT
PRECISION ERROR
AMP AND REFERENCE
Current Doubler
The current doubler secondary employs two output inductors that equally share the output load current. The transformer secondary is not center-tapped. This configuration
provides 2× higher output current capability compared to
similarly sized single output inductor modules, hence the
name. Each output inductor is twice the inductance value
as the equivalent single inductor configuration and the
transformer turns ratio is 1/2 that of a single inductor
secondary. The drive to the inductors is 180 degrees out
of phase which provides partial ripple current cancellation
in the output capacitor(s). Reduced capacitor ripple current lowers output voltage ripple and enhances the
capacitors’s reliability. The amount of ripple cancellation
is related to duty cycle (see Figure 13). Although the
current doubler requires an additional inductor, the inductor core volume is proportional to LI2, thus the size penalty
is small. The transformer construction is simplified without a center-tap winding and the turns ratio is reduced by
1/2 compared to a conventional full wave rectifier configuration.
1922 F12
1
Figure 12. Compensation for Polymer Electrolytic
Aluminum Electrolytic (see Figure 12) the goal of this
compensator will be to cross over the output minimum
pole frequency. Set a low frequency pole with CC and RIN
at a frequency that will cross over the loop at the output
pole minimum F, place the zero formed by CC and Rf at the
output pole F.
NOTE: INDUCTOR(S) DUTY CYCLE
IS LIMITED TO 50% WITH CURRENT
DOUBLER PHASE SHIFT CONTROL.
NORMALIZED
OUTPUT RIPPLE
CURRENT
ATTENUATION
Synchronous Rectification
The LTC1922-1 produces the precise timing signals necessary to control current doubler secondary side synchronous MOSFETs on OUTE and OUTF. Synchronous rectifiers are used in place of Schottky or Silicon diodes on the
secondary side of the power supply. As MOSFET RDS(ON)
levels continue to drop, significant efficiency improvements can be realized with synchronous rectification,
provided that the MOSFET switch timing is optimized. An
additional benefit realized with synchronous rectifiers is
bipolar output current capability. These characteristics
improve transient response, particularly overshoot, and
improve ZVS ability at light loads.
0
0
0.25
DUTY CYCLE
0.5
1922 • F13
Figure 13. Ripple Current Cancellation vs Duty Cycle
Synchronous rectification of the current doubler secondary requires two ground referenced N-channel MOSFETs.
The timing of the LTC1922-1 drive signals is shown in the
Timing Diagram. Synchronous rectifier turn-on is internally delayed by the LTC1922-1 after OUT (C or D)
turn-off—just after the end of a power cycle. Synchronous
rectifier turn-off occurs coincident with OUT (A or B)
turn-off. This gives a passive transition time margin before
21
LTC1922-1
U
OPERATIO
the start of a new power cycle. A noninverting MOSFET
driver such as the LTC1693-1 (Figure 14) is used so that
a single signal transformer with secondary center tap can
be employed to translate the drive signals from the primary to the secondary side. In the event of overcurrent
shutdown, or UVLO condition, both synchronous rectification MOSFETs are driven on in order to protect the load
circuitry.
further eased since all of the switches turn on with zero
VDS, eliminating the “Miller” effect. Low turn-off resistance is critical, however, in order to prevent excessive
turn-off losses resulting from the same Miller effects that
were not an issue for turn on. The LTC1922-1 does not
require the propagation delays of the high and low side
drive circuits to be precisely matched as the DirectSense
ZVS circuitry will adapt accordingly, unlike previous solutions. As a result, LTC1922-1 can drive a simple NPN-PNP
buffer or a gate driver chip like the LTC1693-1 to provide
the low side gate drive. Providing drive to the high side
presents additional challenges since the MOSFET gate
must be driven above the input supply. A simple circuit
(Figure 15) using a single LTC1693-1, an inexpensive
signal transformer, and a few discrete components provides both high side gate drives (A and C) reliably.
Full-Bridge Gate Drive
The full-bridge converter requires high current MOSFET
gate driver circuitry for two ground referenced switches
and two high side referred switches. Providing drive to the
ground referenced switches is not too difficult as long as
the traces from the gate driver chip or buffer to the gate and
source leads are short and direct. Drive requirements are
LTC1693-1
OUT1
IN1
LTC1922-1
1:2
OUTE
GND1
OUTF
GND2
IN2
OUT2
1922 F14
Figure 14. Isolated Drive Circuitry
VIN
REGULATED
BIAS
LTC1922-1
VCC
0.1µF
0.1µF
OUTA
OR
OUTC
IN
2k
BAT
54
OUT
2µF
CER
POWER
MOSFET
1/2
LTC1693-1
GND
SIGNAL
TRANSFORMER
BRIDGE
LEG
1922 F15
Figure 15. High Side Gate Driver Circuitry
22
LTC1922-1
U
PACKAGE DESCRIPTIO
Dimensions in inches (millimeters) unless otherwise noted.
G Package
20-Lead Plastic SSOP (0.209)
(LTC DWG # 05-08-1640)
7.07 – 7.33*
(0.278 – 0.289)
20 19 18 17 16 15 14 13 12 11
7.65 – 7.90
(0.301 – 0.311)
1 2 3 4 5 6 7 8 9 10
5.20 – 5.38**
(0.205 – 0.212)
1.73 – 1.99
(0.068 – 0.078)
0° – 8°
0.13 – 0.22
(0.005 – 0.009)
0.65
(0.0256)
BSC
0.55 – 0.95
(0.022 – 0.037)
0.05 – 0.21
(0.002 – 0.008)
0.25 – 0.38
(0.010 – 0.015)
NOTE: DIMENSIONS ARE IN MILLIMETERS
*DIMENSIONS DO NOT INCLUDE MOLD FLASH. MOLD FLASH
SHALL NOT EXCEED 0.152mm (0.006") PER SIDE
**DIMENSIONS DO NOT INCLUDE INTERLEAD FLASH. INTERLEAD
FLASH SHALL NOT EXCEED 0.254mm (0.010") PER SIDE
G20 SSOP 1098
N Package
20-Lead PDIP (Narrow 0.300)
(LTC DWG # 05-08-1510)
1.040*
(26.416)
MAX
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
0.255 ± 0.015*
(6.477 ± 0.381)
0.130 ± 0.005
(3.302 ± 0.127)
0.300 – 0.325
(7.620 – 8.255)
0.009 – 0.015
(0.229 – 0.381)
(
+0.035
0.325 –0.015
+0.889
8.255
–0.381
)
0.045 – 0.065
(1.143 – 1.651)
0.020
(0.508)
MIN
0.065
(1.651)
TYP
0.125
(3.175)
MIN
0.005
(0.127)
MIN
0.100
(2.54)
BSC
*THESE DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS.
MOLD FLASH OR PROTRUSIONS SHALL NOT EXCEED 0.010 INCH (0.254mm)
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
0.018 ± 0.003
(0.457 ± 0.076)
N20 1098
23
LTC1922-1
U
TYPICAL APPLICATIO
Synchronous Phase Shifted Full Bridge 48V to 3.3V, 40A Isolated Converter
10V
D2
BAS21
R3
470Ω
D1
BAS21
C3
2.2µF
VCC2
VCC1
1
R6
470Ω
+VOUT
VLOW
Q3
R4
10Ω
Q4
FMMT718
8T
L4
2.2µH
P
C8, 1nF
100V
R2
10k
0.125W
2T
VHIGH
Q5
FMMT619
Q6
FMMT619
Q11
Q13
FMMT718
C14
0.1µF
Q10
+
+
+
C11
470µF
6V
Q7
R9
0.06Ω
1W
T3
TTWB-1010
10V
22µF
25V
Q8
C9
470µF
6V
Q12
Q14
FMMT718
R10
470Ω
Q9
C4 +
470µF
6V
C7 +
470µF
6V
L3
2.4µH
10V
10V
R8
470Ω
D4
BAT54
T2
TTWB-1010
L2
2.4µH
Q2
FMMT718
A
IN1
R7
2.2k
C12
0.1µF
R1
10
C1
2.2µF
6
7
OUT1
U1
LTC1693-1
5
3
OUT2
IN2
4
2
GND1 GND2
R5
2.2k
D3
BAT54
Q1
8
D6
BAS21
R11
10Ω
0.125W
C15
2.2nF
250V
AC "Y"
VHIGH
L5
1mH
BAS21 BAS21
D6
BAS21
7T
R18
470Ω
0.125W
T4, TTWB-1010
C18 R21
0.1µF 3.3Ω
0.125W
C16
1nF
R19
4.7k
C22 R28
0.1µF 3.3Ω
0.125W
C19
1nF
R27
4.7k
D11
BAT54
R22
950Ω
0.125W
D13
BAT54
R15
2k
0.125W
VLOW
U2
8 LTC1693-1 6
VCC1
VCC2
3
5
IN2
OUT2
1
7
IN1
OUT1
2
4
GND2 GND1
Q15
FZT600
C20
1µF
D12
MMSZ4240BT1
10V
C21
4.7µF
D16
C17
0.22µF
50V
– VOUT
T5, TTWB-1010
+VIN
C5
1.5µF
100V
–VIN
A
L1
4.7µH
C10
1.5µF
100V
C2
1.5µF
100V
C6
1.5µF
100V
10V
R20
310k
R23
30k
R24
10k
D14
1N4699
12V
R29
510Ω
D15
1N4683
3V
C28
68µF
20V
R17
13.3k
1%
C33
0.1µF
P
C34
0.1µF
C23
100pF
R26
1k
1%
9
+
R13
13.3k
1%
R25
1k
1%
SBUS
15
C27
0.1µF
R12
13.3k
1%
R16
13.3k
1%
10
18
ADLY
DRVA
8
16
PDLY
R14
510Ω
2
17
14
SYNC
1
VREF
CT
11
5.1k
RLEB
20
C29
1µF
R35
3.3k
C30
180pF
+VOUT
R30
ISO1
470
MOC207
7 4 3 1
12
OUTF
13
OUTE
4 6
COMP
GND
5
R34
20k
19
SS
FB
7
6
C31
0.068µF
NOTE: UNLESS OTHERWISE
NOTED
ALL CAPS 25V
ALL RESISTORS 1206, 5%
ALL DIODES MMBT914LT1
ALL NPNs MMBT3904LT1
ALL PNPs MMBT3906LT3
3
RAMP DRVB DRVD CS
DRVC
U3
LTC1922-1
VIN
C1, C3 TAIYO YUDEN EMK316BJ225ML (X5R, 16V, 1206)
C2, C5, C6, C10 VITRAMON VJ1825Y155MXB(X7R, 1825)
C4, C7, C9, C11 KEMET T510X477M006AS (TANT, 7343H)
C15 MU RATA GHM3035C7R222K-GC (X7R, 2220)
C17 TAIYO YUDEN UMK316BJ224ML (X7R,1206)
C20, C29 TAIYO YUDEN UMK316BJ105ML (X7R,1206)
C28 AVX TPSE686M020R0125 (TANT 7343H)
C21 TAIYO YUDEN EMK325BJ475MN (X5R, 1210)
R9 DALE WSL
L1 COILCRAFT DO3316P-472
L5 COILCRAFT DO1608C-105
L2, L2 PULSE P1977 PQ20/20 1.25mohms 20A
Q7, Q8, Q9, Q10 SUD50N03
Q1, Q3, Q11, Q12 SUD30N10-25
5
8
2
R36
100k
C25
C24
0.1µF 0.01µF
1
U4
LT1431
3
COLL
V+
2
6
GNDF COMP
4
5
GNDS RTOP
8
7
RMID
REF
R31
7.5k
R33
3.01k
1%
R32
10k
C26
0.02µF
R37
9.3k
1%
– VOUT
1922 TA02
RELATED PARTS
PART NUMBER
DESCRIPTION
COMMENTS
LT1105
Off-Line Switching Regulator
Built-In Isolated Regulation without Optoisolator
LT1681/LTC1698
36V to 72V Input Isolated DC/DC Converter Chipset
Synchronous Rectification; Overcurrent, Overvoltage, UVLO
Protection; Power Good Output Signal;h Voltage Margining;
Compact Solution
LT1683
Ultralow Noise Push-Pull DC/DC Converter
Minimizes Conducted and Radiated EMI; Reduces Need for Filters,
Shields and PCB Iterations
LTC1693-1
High Speed Dual MOSFET Driver
1.5A Peak Output Current; 4.5V ≤ VIN ≤ 13.2V
LT1725
General Purpose Isolated Flyback Controller
48V to 5V Conversion; No Optoisolator Required
24
Linear Technology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408)432-1900 ● FAX: (408) 434-0507 ● www.linear-tech.com
1922f LT/TP 0501 2K • PRINTED IN USA
 LINEAR TECHNOLOGY CORPORATION 2000
Similar pages