Kersemi MBR2035 20 amp schottky barrier rectifier 20 to 100 volt Datasheet

 omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
MBR2020
THRU
MBR20100
Features
•
•
•
•
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
20 Amp
Schottky Barrier
Rectifier
20 to 100 Volts
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Microsemi
Catalog
Number
MBR2020
MBR2030
MBR2035
MBR2040
MBR2045
MBR2060
MBR2080
MBR20100
Device
Marking
MBR2020
MBR2030
MBR2035
MBR2040
MBR2045
MBR2060
MBR2080
MBR20100
Maximum
Recurrent
Peak
Reverse
Voltage
20V
30V
35V
40V
45V
60V
80V
100V
TO-220AC
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
C
B
S
F
Q
T
14V
21V
24.5V
28V
31.5V
42V
56V
70V
20V
30V
35V
40V
45V
60V
80V
100V
A
U
H
K
L
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element MBR2020-2045
IF(AV)
20A
TC = 135°C
IFSM
150A
8.3ms, half sine
VF
MBR2060
MBR2080-20100
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
www.kersemi.com
.63V
.75V
.84V
IFM = 20A per
element;
TA = 25°C*
IR
0.1mA
TJ = 25°C
J
R
G
A
B
C
D
F
G
H
J
K
L
Q
R
S
T
U
INCHES
.595
.620
.380
.405
.160
.190
.025
.035
.142
.147
.190
.210
.110
.130
.018
.025
.500
.562
.045
.060
.100
.120
.080
.110
.045
.055
.235
.255
-----.050
MM
15.11
9.65
4.06
0.64
3.61
4.83
2.79
0.46
12.70
1.14
2.54
2.04
1.14
5.97
-----
15.75
10.29
4.82
0.89
3.73
5.33
3.30
0.64
14.27
1.52
3.04
2.79
1.39
6.48
1.27
MBR2020 thru MBR20100
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
10
100
MBR2060
60
6
4
40
2
20
MBR2020-1645
1
10
.6
6
.4
4
MBR2080-20100
.2
2
TJ=25°C
25°C
µAmps .1
Amps 1
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.3
.4
.5
.6
.7
75
50
100
125 150
175
.8
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
20
150
18
125
14
100
75
10
Amps
Amps
50
8
25
5
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
125
150
°C
1
2
4
6
8 10
20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
www.kersemi.com
Similar pages