AIMTEC AM2DC-1209DH60Z 2 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM2DC-Z
2 Watt | DC-DC Converter
FEATURES:








RoHS compliant SIP7 package
High efficiency up to 82%
I/O Isolation 6000 VDC
Low coupling capacity
Physical clearance of Isolation barrier 6mm
Safety barrier 100% production tested
Rated working voltage of 250 Vrms
Continuous Short Circuit Protection
Models
Single output
Input
Voltage (V)
Output Voltage
(V)
Output Current
Max (mA)
Max Capacitive
Load (uF)
Efficiency
(%)
5
5
5
5
5
12
12
12
12
12
15
15
15
15
15
24
24
24
24
24
3.3
5
9
12
15
3.3
5
9
12
15
3.3
5
9
12
15
3.3
5
9
12
15
600
400
222
167
133
600
400
222
167
133
600
400
222
167
133
600
400
222
167
133
1000
470
470
220
220
1000
470
470
220
220
1000
470
470
220
220
1000
470
470
220
220
73
78
80
80
82
73
78
80
80
82
73
78
80
80
82
73
78
80
80
82
Model
Input
Voltage (V)
Output Voltage
(V)
Output Current
max (mA)
Max Capacitive
Load (uF)
Efficiency
(%)
AM2DC-0503DH60Z
AM2DC-0505DH60Z
AM2DC-0509DH60Z
AM2DC-0512DH60Z
AM2DC-0515DH60Z
AM2DC-051509DH60Z
AM2DC-1203DH60Z
AM2DC-1205DH60Z
AM2DC-1209DH60Z
AM2DC-1212DH60Z
AM2DC-1215DH60Z
AM2DC-121509DH60Z
AM2DC-1503DH60Z
AM2DC-1505DH60Z
AM2DC-1509DH60Z
AM2DC-1512DH60Z
AM2DC-1515DH60Z
AM2DC-151509DH60Z
5
5
5
5
5
5
12
12
12
12
12
12
15
15
15
15
15
15
±3.3
±5
±9
±12
±15
+15/-9
±3.3
±5
±9
±12
±15
+15/-9
±3.3
±5
±9
±12
±15
+15/-9
±300
±200
±111
±83
±67
+67/-111
±300
±200
±111
±83
±67
+67/-111
±300
±200
±111
±83
±67
+67/-111
±470
±220
±220
±100
±100
+100/-220
±470
±220
±220
±100
±100
+100/-220
±470
±220
±220
±100
±100
+100/-220
73
78
80
80
82
72
73
78
80
80
82
72
73
78
80
80
82
72
Model
AM2DC-0503SH60Z
AM2DC-0505SH60Z
AM2DC-0509SH60Z
AM2DC-0512SH60Z
AM2DC-0515SH60Z
AM2DC-1203SH60Z
AM2DC-1205SH60Z
AM2DC-1209SH60Z
AM2DC-1212SH60Z
AM2DC-1215SH60Z
AM2DC-1503SH60Z
AM2DC-1505SH60Z
AM2DC-1509SH60Z
AM2DC-1512SH60Z
AM2DC-1515SH60Z
AM2DC-2403SH60Z
AM2DC-2405SH60Z
AM2DC-2409SH60Z
AM2DC-2412SH60Z
AM2DC-2415SH60Z
Models
Dual output
www.aimtec.com
F 051e R6
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2DC-Z
2 Watt | DC-DC Converter
Models
Dual output (continued)
Model
Input
Voltage (V)
Output Voltage
(V)
Output Current
max (mA)
Max Capacitive
Load (uF)
Efficiency
(%)
AM2DC-2403DH60Z
AM2DC-2405DH60Z
AM2DC-2409DH60Z
AM2DC-2412DH60Z
AM2DC-2415DH60Z
AM2DC-241509DH60Z
24
24
24
24
24
24
±3.3
±5
±9
±12
±15
+15/-9
±300
±200
±111
±83
±67
+67/-111
±470
±220
±220
±100
±100
+100/-220
73
78
80
80
82
72
Input Specifications
Parameters
Voltage range
Filter
Startup time
Nominal
Typical
5
12
15
24
4.5-5.5
10.8-13.2
13.5-16.5
21.6-26.4
Maximum
Units
VDC
Capacitor
Absolute Maximum Rating
Vnom, constant resistive load
5 Vin
12 Vin
15 Vin
24 Vin
20
5 Vin
12 Vin
15 Vin
24 Vin
See the suggested circuit
70
40
30
20
20
Conditions
Typical
ms
0-7
0-15
0-18
0-28
100
Peak Input Voltage time
Quiescent Current
Input Reflected Ripple current
VDC
ms
mA
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage (rated for 1 min)
Rated working voltage
60 sec
Reinforced Insulation, 1 x MOPP
Reinforced Insulation, 2 x MOPP
Resistance
Capacitance
Rated
Units
6000
VDC
250
125
>1000
10
V rms
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Cross Regulation (dual output)
Temperature coefficient
Ripple and Noise*
Conditions
Typical
Maximum
±3
Continuous
Auto recovery
For 1% change of V in
±1.2
From 10 to 100% load
±10
25% to 100% one load & 100% other load
±4
±0.03
20MHz Bandwidth
Units
%
100
%
%
%
%/oC
mV p-p
*Output ripple and noise are measured with external connection of 10uF electrolytic capacitor and 1uF ceramic capacitor.
www.aimtec.com
F 051e R6
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2DC-Z
2 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Creepage and Clearance Distance
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Soldering temperature
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load, depending of the model
Input to Output
Full Load without Derating
50 - 100
>6
Maximum
-40 to +85
-40 to +125
100
Units
KHz
mm
oC
oC
oC
Free air convection
95
Non-conductive black plastic, epoxy encapsulated (UL94V-0 rated)
1.5mm from case for 10 sec.
260
4.2
0.77 x 0.39 x 0.49 inches
19.56 x 9.80 x 12.50 mm
>2 390 000 hrs (MIL-HDBK-217 F at +25 oC)
% RH
oC
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Safety Specifications
Parameters
EN 55022: 2010, Class B
EN 55024: 2010
IEC 61000-4-2: 2008, Criteria A
IEC 61000-4-3: 2010, Criteria A
IEC 61000-4-4: 2012, Criteria A (with external circuit)
IEC 61000-4-6: 2008, Criteria A
IEC 61000-4-8: 2009, Criteria A
Designed to meet IEC/EN 60950-1 & IEC/EN 60601-1
Standards
Pin Out Specifications
Pin
1
2
5
6
7
19.5
(0.77)
6000 VDC
Single
+ V Input
- V Input
- V Output
No pin
+ V Output
Dual
+ V Input
- V Input
- V Output
Common
+ V Output
Dimensions
9.8
(0.39)
PRINTED
FACE
12.0
(0.47)
0.50
(0.02)
3.00
(0.12)
2.54
(0.10)
15.24
(0.60)
0.50
(0.02)
9.8
(0.39)
NOTE: Unit:mm [inch]
Pin Diameter: 0.50 ± 0.05mm [0.02 ± 0.002 inch]
Pin Pitch tolerance: ±0.35mm [ ±0.014 inch]
Case tolerance: ±0.50mm [ ±0.02 inch]Pin Out
Specifications
0.3(0.01)
2.40
(0.09)
www.aimtec.com
F 051e R6
0.50
(0.02)
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2DC-Z
2 Watt | DC-DC Converter
Input Reflected Ripple Current Test Circuit
Recommended Application circuit for reducing the output ripple and noises:
Recommended Output Capacitor to reduce the converter’s ripple and noises for single output models is 4.7µF to 100µF and for dual
output models is 4.7µF to 68µF connected to both outputs.
Li with value of 12µH and Ci with value 10µF to 100µF are recommended to be connected to the input of the converter for EMI
improvement.
EMI Filter Circuit recommendation
Vin
C1
5, 12, 15 V
470 µF / 100V
24 V
470 µF / 100V
* Electrolytic type
L1
C2
C3
18 µH
18 µH
2.2 µF / 100V
470 pF / 2kV
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only