CT-2 CONNECTOR TERMINAL COMPACT CONNECTOR TERMINAL FOR REDUCED WIRING Pressure connector connect type Wire-direct connect type FEATURES TYPICAL APPLICATIONS • One-touch wiring with the various controller types greatly reduces the time required for wiring operations. • Compact space-saving design Design and dimensions match those for the RT-2 relay terminal. • Wide variation of pole: 20, 30, 34 and 40 poles • Available in pressure connector connect type and wire-direct connect type The direct connect type is a compact 62 × 52 mm 2.441× 2.047 inch (20P type). • Exclusive cables can be provided • Integrated AXM connector (complying to MIL Standard, Long lever type) I/O interface for PLCs, personal computers and various types of controllers. ORDERING INFORMATION Ex. CT2 M Installation type C 20 Termination type Blank: DIN rail mounting Blank: Pressure connector type connect type M: Direct mounting C: Wire-direct type connect type No. of poles 20: 20 poles 30: 30 poles 34: 34 poles 40: 40 poles TYPES 1. DIN rail mounting type Connection method Pressure connector connect type Wire-direct connect type 2. Direct mounting type No. of poles Part No. 20 30 34 40 20 30 34 40 CT2-20 CT2-30 CT2-34 CT2-40 CT2-C-20 CT2-C-30 CT2-C-34 CT2-C-40 Packing quantity Inner carton Outer carton Pressure connector connect type 1 pc. 20 pcs. Wire-direct connect type SPECIFICATIONS Rated voltage Rated current Breakdown voltage Insulation resistance Fasten torque Ambient temperature Connection method No. of poles Part No. 20 30 34 40 20 30 34 40 CT2-M-20 CT2-M-30 CT2-M-34 CT2-M-40 CT2-MC-20 CT2-MC-30 CT2-MC-34 CT2-MC-40 Packing quantity Inner carton Outer carton 1 pc. 20 pcs. No. of poles 20 30 34 40 Part No. AXM120415 AXM130415 AXM134415 AXM140415 CONNECTOR 125 V AC 1A 250 Vrms for in min. 100 MΩ (at 500 V DC megger) Pressure connector connect type: 0.3 to 0.5 N·m {3 to 5 kgf·cm} Wire-direct connect type 0.2 to 0.4 N·m {2 to 4 kgf·cm} 0°C to +55°C +32°F to +131°F • Applicable connector (socket) Product name MIL type AXM Flat Cable Connector • Applicable flat cable Standard wire: standard pitch (1.27 mm 0.050 inch)/ conductor #28 (7 wire/0.127 dia.) All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. CT-2 TERMINAL BLOCK 1. Pressure connector connect type • Applicable electrical wire 0.25 to 1.65 mm2 .01 to .065 inch • Applicable wire-pressed terminals 2. Wire-direct connect type When wiring screw-clamped terminal blocks, strip the lead wires and connect them properly. mm inch 3 dia. min. .118 dia. min. 5.6 max. .220 max. 3 min. .118 min. Stripping length 8 to 10 mm .315 to .394 inch Recommended wire • 0.128 to 1.318 mm .005 to 0.52 inch • 0.4 to 1.3 mm dia. .016 to .051 inch dia. 5.6 max. .220 max. 4 4.5 min. .157 .117 min. 4 4.5 min. .157 .177 min. DIMENSIONS mm inch 1. DIN rail mounting type Pressure connector connect type (20 poles) Wire-direct connect type 20 poles 98±1 3.858±.039 B1 42±0.6 1.654±.024 62±1 2.441±.039 B1 B10 B1 B10 A1 A10 A1 A10 B2 A1 B3 B4 A2 7.62±0.3 .300±.012 B5 A3 B6 A4 A5 B7 A6 B9 B8 A7 A8 ±1 B10 A9 52 2.047±.039 A10 52±1 2.047±.039 5.08±0.3 .200±.012 20-M3 .118 terminal screw 6.2±0.3 .244±.012 Pressure connector connect type (30 poles) Wire-direct connect type (30 poles) 98±1 3.858±.039 134±1 5.276±.039 B1 B2 A1 B1 B15 B1 B15 A1 A15 A1 A15 B3 A2 7.62±0.3 .300±.012 B5 B4 A4 A3 B6 A5 B7 A6 B8 A7 B9 A8 B10 A9 A10 B11 A11 B12 A12 B13 A13 B14 B15 A14 A15 30-M3 .118 terminal screw 6.2±0.3 .244±.012 Pressure connector connect type (34 poles) 5.08±0.3 .200±.012 Wire-direct connect type 34 poles 98±1 3.858±.039 170±1 6.693±.039 B1 B2 A1 B3 A2 7.62±0.3 .300±.012 B1 B17 B1 B17 A1 A17 A1 A17 B4 A3 B5 A4 B6 A5 B7 A6 B8 A7 B9 A8 A9 B10 B11 B12 B13 B14 B15 B16 B17 A10 A11 A12 A13 A14 A15 A16 A17 34-M3 .118 terminal screw ±0.3 5.08±0.3 .200±.012 6.2 .244±.012 Pressure connector connect type (40 poles) Wire-direct connect type (40 poles) 170±1 6.693±.039 B1 B2 A1 7.62±0.3 300±.012 42±0.6 1.654±.024 B3 A2 B4 A3 B5 A4 B1 B20 B1 B20 A1 A20 A1 A20 B6 A5 134±1 5.276±.039 B7 A6 B8 A7 B9 A8 B12 B13 B14 B16 B17 B18 B19 B20 B11 B15 B10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A9 A10 40-M3 .118 terminal screw 5.08±0.3 .200±.012 6.2±0.3 .244±.012 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. CT-2 2. Direct mounting type Pressure connector connect type (20 poles) Wire-direct connect type 20 poles 115±1 4.528±.039 106±0.5 4.173±.020 (M4 .157 screw mounting pitch) 98±1 3.858±.039 79±1 3.110±.039 70±0.5 2.756±.020 (M4 .157 screw mounting pitch) 62±1 2.441±.039 B1 mm inch 2-M4 .157 screw mounting position 42±0.6 1.654±.024 B1 B10 B1 B10 A1 A10 A1 A10 B2 A1 B3 A2 7.62±0.3 .300±.012 B4 B5 A3 B6 A4 A5 B7 A6 B8 A7 B9 A8 A10 5.08±0.3 .200±.012 20-M3 .118 terminal screw 6.2±0.3 .244±.012 52±1 2.047±.039 52±1 2.047±.039 B10 A9 Pressure connector connect type (30 poles) Wire-direct connect type (30 poles) 115±1 4.528±.039 106±0.5 4.173±.020 (M4 .157 screw mounting pitch) 98±1 3.858±.039 151±1 5.945±.039 ±0.5 142 5.591±.020 (M4 .157 screw mounting pitch) 134±1 5.276±.039 B1 B2 A1 B1 B15 B1 B15 A1 A15 A1 A15 B3 B4 A2 7.62±0.3 .300±.012 B5 A3 B6 A4 A5 B7 A6 B8 A7 B9 A8 B10 B11 B12 B13 B14 B15 A9 A10 A11 A12 A13 A14 A15 30-M3 .118 terminal screw 6.2±0.3 .244±.012 Pressure connector connect type (34 poles) 5.08±0.3 .200±.012 Wire-direct connect type 34 poles 115±1 4.528±.039 ±0.5 106 4.173±.020 (M4 .157 screw mounting pitch) 98±1 3.858±.039 187±1 7.362±.039 ±0.5 178 7.008±.020 (M4 .157 screw mounting pitch) 170±1 6.693±.039 B1 B2 A1 B3 A2 7.62±0.3 .300±.012 B1 B17 B1 B17 A1 A17 A1 A17 B4 A3 B5 A4 B6 A5 B7 A6 B8 A7 B9 A8 A9 B10 B11 B12 B13 B14 B15 B16 B17 A10 A11 A12 A13 A14 A15 A16 A17 34-M3 .118 terminal screw ±0.3 5.08±0.3 .200±.012 6.2 .244±.012 Pressure connector connect type (40 poles) Wire-direct connect type (40 poles) 187±1 7.362±.039 ±0.5 178 7.008±.020 (M4 .157 screw mounting pitch) 170±1 6.693±.039 B1 B2 A1 7.62±0.3 .300±.012 2-M4 .157 screw mounting position 42±0.6 1.654±.024 B3 A2 B4 A3 B5 A4 ±0.3 B1 B20 B1 B20 A1 A20 A1 A20 B6 A5 151±1 5.945±.039 ±0.5 142 5.591±.020 (M4 .157 screw mounting pitch) 134±1 5.276±.039 B7 A6 B8 A7 B9 A8 B19 B20 B11 B12 B13 B14 B15 B16 B17 B18 B10 A11 A19 A20 A12 A13 A14 A15 A16 A17 A18 A9 A10 40-M3 .118 terminal screw 5.08±0.3 .200±.012 6.2 .244±.012 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. CT-2 SCHEMATIC (Top View) 20 poles 34 poles A Connector No. 1 2 3 4 5 6 7 8 9 10 Connector No. Terminal No. (from left on the lower stage) 1 2 3 4 5 6 7 8 9 10 A Terminal No. (from left on the lower stage) Connector No. Terminal No. (from left on the upper stage) B 1 2 3 4 5 6 7 8 9 10 Connector No. Terminal No. (from left on the upper stage) 1 2 3 4 5 6 7 8 9 10 B 30 poles A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B 40 poles Connector No. Terminal No. (from left on the lower stage) Connector No. Terminal No. (from left on the upper stage) A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A Connector No. Terminal No. (from left on the lower stage) B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 B Connector No. Terminal No. (from left on the upper stage) A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 B CAUTIONS FOR USE 1. Installation 1) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. 2. Removal of cover 1) Insertions and withdraws of connector can be done by lifting the cover like 1. 2) Wiring to the terminal can be done by lifting the cover like 2. 3) Removal of the cover can be done by lifting it like 3. 4) In case of resetting the cover, please push the cover like 4. 1 2 1 First push in the DIN rail locking lever. DIN rail locking lever DIN rail 3 Press the unit onto the DIN rail. 2 Hook the holders on the unit over the DIN rail. 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 3 4 3 Remove the unit from the DIN rail. 2 Move the screwdriver in the direction of the arrows, and pull out the lever. 1 Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. 4) Be careful not to drop or shock the unit. Excessive shock such as dropping may cause damage or malfunction. 3. Wiring and circuit configuration 1) Make all connections according to the schematic. 2) When wiring power lines or power cables, twisted pair treatment (standed wire treatment) should be done in order to improve noise resistance. 3) In order to improve noise resistance, class 3 grounding of the control panel is recommended. 4) Turn off the power before connecting/ disconnecting connector cables. 4. Operating environment 1) Use the product at ambient operating temperature between 0°C and 55°C 32°F and 131°F. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as benzine, thinner, and alcohol or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 5. Transporting and storage 1) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the inner and outer boxes with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. • Temperature: 5 to 30°C 41 to 86° F • Humidity: Max. 60% R.H. • Environment: No hazardous substances such as sulfurous acid gases and little dust. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.