Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] The ACTF4001/426.0/QCC8C is a low-loss, compact, and economical surface-acoustic-wave (SAW) filter in a surface-mount ceramic QCC8C case intended for use in Mobile Radio ( FRS & PMR ) applications. 1.Package Dimension (QCC8C) 2. Pin Configuration 2 Input / Output 6 Output / Input 1,3, 5,7 To be Grounded 4,8 Case Ground Sign Data (unit: mm) Sign Data (unit: mm) A 2.08 E 1.20 B 0.60 F 1.35 C 1.27 G 5.00 D 2.54 H 5.00 3. Test Circuit In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 4.Typical Frequency Response 5.Performance 5-1.Maximum Rating Rating Value Units Input Power Level 10 dBm DC Voltage 12 V -40 to +85 °C +235 °C Storage Temperature Soldering Temperature In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 5-2.Electronic Characteristics Characteristics Minimum Typical Maximum Units -- MHz Centre Frequency fC -- 426.000 Usable Pass Band BW -- ±2.0 Insertion Loss (f C±2.0MHz) IL MHz 3.5 5.0 dB 40 45 45 50 -- dB -- 2.0 -- dB Rejection fC <fC – 20.0MHz fC >fC +25.0MHz Pass Band Ripple (with f C±2.0MHz) Input and Output Impedance 50Ω iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling! 1. 2. 3. 4. 5. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality. Unless noted otherwise, specifications apply over the entire specified operating temperature range. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies. In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010