ACT ACTF4001 Saw filter Datasheet

Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
The ACTF4001/426.0/QCC8C is a low-loss, compact, and economical surface-acoustic-wave (SAW)
filter in a surface-mount ceramic QCC8C case intended for use in Mobile Radio ( FRS & PMR )
applications.
1.Package Dimension (QCC8C)
2.
Pin
Configuration
2
Input / Output
6
Output / Input
1,3, 5,7
To be Grounded
4,8
Case Ground
Sign
Data (unit: mm)
Sign
Data (unit: mm)
A
2.08
E
1.20
B
0.60
F
1.35
C
1.27
G
5.00
D
2.54
H
5.00
3. Test Circuit
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1.1 C1
Date : March 2010
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
4.Typical Frequency Response
5.Performance
5-1.Maximum Rating
Rating
Value
Units
Input Power Level
10
dBm
DC Voltage
12
V
-40 to +85
°C
+235
°C
Storage Temperature
Soldering Temperature
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1.1 C1
Date : March 2010
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
5-2.Electronic Characteristics
Characteristics
Minimum
Typical
Maximum
Units
--
MHz
Centre Frequency
fC
--
426.000
Usable Pass Band
BW
--
±2.0
Insertion Loss
(f C±2.0MHz)
IL
MHz
3.5
5.0
dB
40
45
45
50
--
dB
--
2.0
--
dB
Rejection
fC <fC – 20.0MHz
fC >fC +25.0MHz
Pass Band Ripple (with f C±2.0MHz)
Input and Output Impedance
50Ω
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
2.
3.
4.
5.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1.1 C1
Date : March 2010
Similar pages