Electrical Characteristics
@ 25 °C
Contact form
B
Contact rating max.
W / VA
3
VDC
30
VAC
30
Switching current max.
A
0.2
Carry current max.
A
0.5
Breakdown voltage min.
VDC
150
Total resistance max. (initial)
mΩ
200
Ω
10 9
Switching voltage max.
Insulation resistance min.
Magnetical Characteristics (of unmodified Reed Switch)
AT
Drop out min.
AT
6
Test coil
TC
200
Test equipment tolerance
± AT
Replaces various competitors types
Not ESD sensitive
Approvals
10 - 30
2
Operating Characteristics (of unmodified Reed Switch)
Switching frequency max.
Easily mountable and removable as no
tools or screws required
@ 25 °C
Pull in range available
Features
@ 25 °C
Hz
200
Resonant frequency typ.
Hz
6000
Operate time max. (incl. bounce)
ms
200
Release time max.
ms
0.5
Operating temperature
°C
-20 to + 85
Vibration (10-1000 Hz)
g
20
Shock (1/2 sin 11 ms)
g
30
Environmental Characteristics
© PIC GmbH
Dimensions in mm
Ordering Information
Packing Unit
50
pcs
Weight per piece
0
g
Weight per package
0
g
Standard AT Ranges
1 = 10 to 15 AT
2 = 15 to 20 AT
3 = 20 to 25 AT
4 = 25 to 30 AT
Ordering Example
MS-2431-7-1-0300 describes
MS-2431 Form B with 10-15 AT
Page 1 of 2
Rev.:
1.0
ms24317_ds_e_1.0
PIC Proximity Instrumentation Controls
Kontaktbauelemente GmbH
Nibelungenstr. 5 A
90530 Wendelstein, Germany
Phone +49 911 99 59 06-0
Fax
+49 911 99 59 06-99
[email protected]
www.pic-gmbh.com
MS-2431-7
S W I T C HI N G T HE S M A R T WAY
MS-2431-7
Press-Fit Sensor Form B
Material Information
Material
Colour
Housing
PA-GF
white
Cable
UL 1569, AWG 24, 4mm stripped and tinned
black
Potting compound
Epoxy
black
Test Procedure of final Reed Sensor
Test Parameters
Test coil
TC- 324
Test programs
AT range
Test program
1 =
MS-2431-7 -1
2 =
MS-2431-7 -2
3 =
MS-2431-7 -3
4 =
MS-2431-7 -4
Remarks
When mounted onto ferromagnetic parts
switching distance of MS-2431-7
may reduce.
Electromagnetical influences and magnetic
fields may change the switching behaviour of
the sensor.
Recommended drill diameter 9.5 mm
Matching actuator MSM-... available as well.
Test Coil placed in vertical position
Reed Sensor aligns with bottom line
Reed Sensor axially centered in Test Coil
Page 2 of 2
Rev.:
1.0
ms24317_ds_e_1.0
PIC Proximity Instrumentation Controls
Kontaktbauelemente GmbH
Nibelungenstr. 5 A
90530 Wendelstein, Germany
Phone +49 911 99 59 06-0
Fax
+49 911 99 59 06-99
[email protected]
www.pic-gmbh.com
Similar pages