ETC2 MCF/T2915F Chassis mounting transformer Datasheet

Chassis Mounting Transformers
230V Single Primary
6VA to 200VA
Features:
•
Chassis mounting low voltage mains transformers with 230V ac primary winding.
•
2 secondary winding that can be connected in series or parallel.
•
Double section bobbins on interleaved lamination provide 3.75kV isolation.
•
Fixing by clamp on models up to 50VA, and frame construction above.
•
Tested to meet EN60065.
Specifications
Dimensions
VA
6
12
20
50
75
100
150
200
Fixing
Style
Weight
(kg)
Typical
Regulation
(%)
0.2
25
0.4
12
Width
Depth
Height
FC
45
40
37
54
50
72
62
65
92
1.0
75
67
54 x 54
1.5
68
75
57 x 44
59
79
89
100
50
56
78
90
85
72 x 58
72 x 68
Clamp
Frame
0.55
10
1.6
2.2
2.8
7
Dimensions : Millimetres
Page 1
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Part Numbers
Rating
Load
Part Number
0-5V, 0-5V @ 0.6A
MCF/B1805F
0-6V, 0-6V @ 0.5A
MCF/B1806F
0-9V, 0-9V @ 0.33A
MCF/B1809F
0-12V, 0-12V @ 0.25A
0-15V, 0-15V @ 0.2A
6VA - 25% Typical
Regulation
MCF/B1812F
MCF/B1815F
0-18V, 0-18V @ 0.17A
MCF/B1818F
0-20V, 0-20V @ 0.15A
MCF/B1820F
0-24V, 0-24V @ 0.12A
MCF/B1824F
0-5V, 0-5V @ 1.2A
MCF/N3505F
0-6V, 0-6V @ 1A
MCF/N3506F
0-9V, 0-9V @ 0.67A
MCF/N3509F
0-12V, 0-12V @ 0.5A
0-15V, 0-15V @ 0.4A
12VA - 12% Typical
Regulation
MCF/N3512F
MCF/N3515F
0-18V, 0-18V @ 0.33A
MCF/N3518F
0-20V, 0-20V @ 0.3A
MCF/N3520F
0-24V, 0-24V @ 0.25A
MCF/N3524F
0-5V, 0-5V @ 2A
MCF/R3505F
0-6V, 0-6V @ 1.67A
MCF/R3506F
0-6.3V, 0-6.3V @ 1.59A
0-9V, 0-9V @ 1.1A
0-12V, 0-12V @ 0.83A
N/A
20VA - 10% Typical
Regulation
MCF/R3509F
MCF/R3512F
0-18V, 0-18V @ 0.55A
MCF/R3518F
0-20V, 0-20V @ 0.5A
MCF/R3520F
0-24V, 0-24V @ 0.42A
MCF/R3524F
0-6V, 0-6V @ 4.17A
MCF/D2906F
0-9V, 0-9V @ 2.78A
MCF/D2909F
0-12V, 0-12V @ 2.08A
MCF/D2912F
0-15V, 0-15V @ 1.67A
50VA - 10% Typical
Regulation
MCF/D2915F
0-18V, 0-18V @ 1.39A
MCF/D2918F
0-20V, 0-20V @ 1.25A
MCF/D2920F
0-24V, 0-24V @ 1.04A
MCF/D2924F
Page 2
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Part Numbers
Rating
Load
Part Number
0-6V, 0-6V @ 6.25A
MCF/T2906F
0-9V, 0-9V @ 4.17A
MCF/T2909F
MCF/T2912F
0-12V, 0-12V @ 3.12A
0-15V, 0-15V @ 2.5A
75VA - 10% Typical
Regulation
MCF/T2915F
0-18V, 0-18V @ 2.08A
MCF/T2918F
0-24V, 0-24V @ 1.56A
MCF/T2924F
0-50V, 0-50V @ 0.75A
MCF/T2950F
0-6V, 0-6V @ 8.33A
MCF/B19606F
0-9V, 0-9V @ 5.55A
MCF/B19609F
0-12V, 0-12V @ 4.17A
MCF/B19612F
MCF/B19615F
0-15V, 0-15V @ 3.33A
0-18V, 0-18V @ 2.78A
100VA - 10% Typical
Regulation
MCF/B19618F
0-20V, 0-20V @ 2.5A
MCF/B19620F
0-24V, 0-24V @ 2.08A
MCF/B19624F
0-30V, 0-30V @ 1.67A
N/A
0-50V, 0-50V @ 1A
MCF/B19650F
0-6V, 0-6V @ 12.5A
MCF/T9606F
0-9V, 0-9V @ 8.33A
MCF/T9609F
MCF/T9612F
0-12V, 0-12V @ 6.25A
0-15V, 0-15V @ 5A
150VA - 10% Typical
Regulation
MCF/T9615F
0-18V, 0-18V @ 4.17A
MCF/T9618F
0-24V, 0-24V @ 3.12A
MCF.T9624F
0-50V, 0-50V @ 1.5A
MCF/T9650F
0-6V, 0-6V @ 16.7A
MCF/Y9606F
0-9V, 0-9V @ 11.1A
MCF/Y9609F
0-12V, 0-12V @ 8.3A
MCF/Y9812F
MCF/Y9615F
0-15V, 0-15V @ 6.67A
0-18V, 0-18V @ 5.55A
200VA - 7% Typical
Regulation
MCF/Y9618F
0-20V, 0-20V @ 5A
MCF/Y9620F
0-24V, 0-24V @ 4.17A
MCF/Y9624F
0-30V, 0-30V @ 3.33A
N/A
0-50V, 0-50V @ 2A
MCF/Y9650F
Page 3
04/10/05 V1.0
Chassis Mounting Transformers
230V Single Primary
Notes:
International Sales Offices:
AUSTRALIA – Farnell InOne
FINLAND – Farnell InOne
NETHERLANDS – Farnell InOne
SWITZERLAND – Farnell InOne
Tel No:
Tel No:
Tel No:
++ 61 2 9645 8888
Fax No: ++ 61 2 9644 7898
Fax No: ++ 358 9 345 5411
Fax No: ++ 31 30 241 7333
Tel No: ++ 41 1 204 64 64
Fax No: ++ 41 1 204 64 54
AUSTRIA – Farnell InOne
FRANCE – Farnell InOne
NEW ZEALAND – Farnell InOne
UK – Farnell InOne
Tel No:
Tel No:
Tel No:
Tel No:
++ 43 662 2180 680
++ 358 9 560 7780
++ 33 474 68 99 99
++ 31 30 241 7373
++ 64 9 357 0646
++ 44 8701 200 200
Fax No: ++ 43 662 2180 670
Fax No: ++ 33 474 68 99 90
Fax No: ++ 64 9 357 0656
Fax No: ++ 44 8701 200 201
BELGIUM – Farnell InOne
GERMANY – Farnell InOne
NORWAY – Farnell InOne
UK – BuckHickman InOne
Tel No:
Tel No:
Tel No:
++ 45 44 53 66 66
++ 44 8450 510 150
++ 32 3 475 2810
++ 49 89 61 39 39 39
Fax No: ++ 32 3 227 3648
Fax No: ++ 49 89 613 59 01
Fax No: ++ 45 44 53 66 02
++ 44 8450 510 130
BRAZIL – Farnell-Newark InOne
HONG KONG –
Farnell-Newark InOne
Tel No: ++ 852 2268 9888
PORTUGAL – Farnell InOne
UK – CPC
++ 55 11 4066 9400
Tel No:
++ 34 93 475 8804
++ 44 8701 202 530
Fax No: ++ 55 11 4066 9410
Fax No: ++ 852 2268 9899
Fax No: ++ 34 93 474 5288
++ 44 8701 202 531
CHINA – Farnell-Newark InOne
IRELAND – Farnell InOne
SINGAPORE –
Tel No:
Tel No:
Tel No:
++86 10 6238 5152
Fax No: ++86 10 6238 5022
Farnell-Newark InOne
Tel No: ++ 65 6788 0200
++ 353 1 830 9277
Fax No: ++ 353 1 830 9016
Fax No: ++ 65 6788 0300
export
EXPORT – Farnell InOne
Tel No:
++ 44 8701 200 208
Fax No: ++ 44 8701 200 209
For enquiries from all other markets
DENMARK – Farnell InOne
ITALY – Farnell InOne
SPAIN – Farnell InOne
Tel No:
Tel No:
Tel No:
++ 45 44 53 66 44
++ 39 02 93 995 200
++ 34 93 475 8805
Fax No: ++ 45 44 53 66 06
Fax No: ++ 39 02 93 995 300
Fax No: ++ 34 93 474 5107
ESTONIA – Farnell InOne
MALAYSIA –
SWEDEN – Farnell InOne
http://www.farnellinone.com
Tel No:
++ 358 9 560 7780
Fax No: ++ 358 9 345 5411
Farnell-Newark InOne
Tel No: ++ 60 3 7873 8000
Fax No: ++ 60 3 7873 7000
Tel No:
++ 46 8 730 50 00
Fax No: ++ 46 8 83 52 62
http://www.buckhickmaninone.com
http://www.cpc.co.uk
Disclaimer This data sheet and its contents (the "Information") belong to the Premier Farnell Group (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes
in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied.
The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data
sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage
resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded.
This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. © Premier Farnell plc 2004.
Page 4
04/10/05 V1.0
Similar pages