Battery BC18-12 Absorbent glass mat technology for efficient gas recombinatino Datasheet

VRLA Rechargeable Battery
Measures
Technology
Values
Innovation
BC18-12 (BC18-12FR)
FEATURES
Maintenance free(no water topping-up required)
No free acid(Non-spillable battery)
Can be used in any orientation(excluding used inverted)
Absorbent Glass Mat technology for efficient gas recombination
Its design life is up to 5 years in floating application
APPLICATION
UPS
Fishing Lights
Emergency Lights
Lawn Mowers
Video Camcorders(VCR)
SPECIFICATIONS
Nominal Voltage
Approx. Weight
BC18-12:
ABS: UL 94-HB (Dark gray color)
BC18-12FR:
ABS: UL 94-V0 (Light gray color)
5620g(12.39lbs.)
B1 (Fitting M5 bolt & nut) , T2 and I1 are optional
Max. Discharge Current
270 A (5 sec.)
5.4 A
< 3% per month (25 C)
UL
CE
(Fully Charged )
Length (L)
181±1.5(7.13±0.06)
JIS C 8702
GB/T 19639
Width (W)
76±1.5(2.99±0.06)
Container Height (H)
166±1.5(6.54±0.06)
Total Height (TH)
166±1.5(6.54±0.06)
TERMI NAL TYPE
Terminal B1
Terminal I1
Terminal T2
3.4(0.13)
12.0(0.47)
M5x0.8
2.0(0.08)
[M5 BOLT & NUT]
7.95(0.31)
2.0(0.08)
16m
IEC61056
5.5(0.22)
OUTER DIMENSIONS mm(inch)
o
6.35(0.25)
Discharge
Storage
Internal Resistance
ISO14001
0oC~40oC(32oF~104oF)
-20oC~50oC(-4oF~122oF)
-20oC~40oC(-4oF~104oF)
Charge
Self Discharge
ISO 9001
0.8(0.03)
Max. Charge Current
Operating Temperature
Range
18.0 Ah
17.1 Ah
15.3 Ah
10.8 Ah
11.0(0.43)
Terminals
CONTAINER MATERIAL
20 Hour Rate (900mA, 10.5V)
10 Hour Rate (1710mA, 10.5V)
5 Hour Rate (3060mA, 10.5V)
1 Hour Rate (10800mA,9.30V)
5.0(0.20)
Nominal Capacity
12V
[M5 BOLT & NUT]
Terminal Hardware Initial Torque:
B1(2.5Nm±5%),I1(4.0Nm±5%)
o
o
BC18-12 (BC18-12FR) discharge characteristics (25 C/77 F)
Battery Charging Characteristics
(Typical examp le of t he charge characteristics for the standby us e)
13.0
0.21
15.0
0.18
14.0
140
10.0
0.6CA
9.0
0.15
0.12
0.09
0.06
120
Charge voltage
13.0
100
olume
Charge v
1 Discharge
100%(0.05CA x 20h)
50%(0.05CA x 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
3 Temperature:25°C(77°F)
12.0
11.0
10.0
80
60
40
Charge volume(%)
0.17CA 0.095CA 0.05CA
0.25CA
Charge voltage(V)
11.0
Charge current(CA)
Terminal Voltage(V)
12.0
8.0
3CA 2CA
7.0
1CA
0.03
20
Charge current
1
2
3
5
10
20 30
60
2
3
5
10
20 30
0
0
Hr
Min
0
5
10
15
20
0
25
Charge time (hr)
Discharge time
Effect Of Temperature On Long Term Float Life
Application
Charging
method
Charging time
O
0.1CA, 25 C
(h)
Charging Temperature Max. charging
compensation
current
Voltage
coefficient of
(CA)
at 25OC
voltage
100%
50%
(V/cell) charging
(mV/ OC/cell)
discharge discharge
Constant
voltage & 2.25~2.30
Constant
current
charging
For
(with current
cycle service restriction) 2.40~2.50
For standby
power Source
-3
0.3
24
Temp
( OC)
20
Life expectancy(year)
Charging Procedure
0~40
(32~ 104 OF)
-4
0.3
16
10
8
6
5
4
3
2
1
0.5
20
68
10
30
86
50°C
122°F
40
104
Battery temperature
Constant power discharge characteristics at 25 oC/77 oF
Discharge
Time
Charging voltage :
2.275V/cell
Unit: W
5 Min
10 Min
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
651
479
384
229
131.0
52.5
36.2
20.21
10.64
1.75V
753
519
401
237
134.9
53.5
36.7
20.52
10.80
1.70V
800
538
414
242
137.3
54.0
37.0
20.63
10.85
1.65V
836
551
424
246
139.0
54.4
37.1
20.69
10.88
1.60V
864
561
432
249
140.4
54.7
37.2
20.69
10.88
F.V.
(V/cell)
Constant current discharge characteristics at 25 oC/77 oF
Discharge
Time
Unit: A
5 Min
10 Min
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
58.63
42.17
33.38
19.36
11.01
4.372
3.014
1.685
0.886
1.75V
69.11
45.69
34.92
20.10
11.34
4.460
3.060
1.710
0.900
1.70V
73.43
47.33
36.00
20.55
11.54
4.500
3.077
1.718
0.904
1.65V
76.72
48.46
36.83
20.84
11.68
4.532
3.088
1.724
0.907
1.60V
79.26
49.44
37.57
21.05
11.80
4.558
3.097
1.724
0.907
F.V.
(V/cell)
All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
Trial A/0
USA:
B&B BATTERY(USA) INC.
6415 RANDOLPH ST.COMMERCE,CA,90040 U.S.A.
TEL:1-323-278-1900.1-800-278-8599
FAX:1-323-278-1268
E-Mail:[email protected]
CHINA FACTORY:
B.B. BATTERY CO., LTD.
CHENG DONG TRIAL AREA,HUANG GANG,
RAOPING, GUANG DONG,CHINA,515700
TEL:86-768-7601001-2
FAX:86-768-7601469
E-Mail:[email protected]
Web Site: http://www.bb-battery.com
REV. Jun. 2011
EUROPE:
B&B BATTERY(EUROPE) B.V.
SUITE 8, HAAKSBERGWEG 33, 1101
BP AMSTERDAM,THE NETHERLANDS
TEL: 31-30-3200190
MOBILE: 886-933896989
E-Mail: [email protected]
JAPAN:
B&B BATTERY(JAPAN) CO., LTD.
1375-11 NARAHARA-MACHI,HACHIOJI,
TOKYO 193-0803,JAPAN.
TEL:81-426-25-6375
FAX:81-426-25-6375
E-Mail:[email protected]
HONG KONG:
B&B BATTERY(Hong Kong) Co.
TEL:852-2311-4918
FAX:852-2739-1182
E-Mail:[email protected]
TAIWAN:
B.B. BATTERY(TAIWAN) CO., LTD.
TEL:886-6-502-5150
FAX:886-6-589-8087
E-Mail:[email protected]
Powered by
B.B. Battery Co., Ltd.
Similar pages