48 V Input DC-DC Converter Modules Features • DC input range: 36 – 75 V • Efficiency: Up to 93% • Highly efficient: ZCS/ZVS switching • DC output: 1 – 48 V • Fast dynamic response • Maximum operating temp: 100°C, full load • Low profile: 0.37 in. (9.5 mm) • Isolated output • RoHS Compliant 3 • Low noise: Sine Amplitude ConverterTM • Power density up to 145 W/in (SACTM) technology • Agency approvals Size: 2.19 x 1.91 x 0.37 in 55,7 x 48,6 x 9,5 mm Applications • • • • • • • Product Overview Communications Distributed power ATE Defense Aerospace Medical And other applications requiring high efficiency VI Brick DC-DC converters use advanced Sine Amplitude ConverterTM (SACTM) technology, thermally enhanced packaging technologies, and advanced CIM processes to provide high power density and efficiency, superior transient response, and improved thermal management. The high speed 3.5 MHz, zero current switching–zero voltage switching (ZCS–ZVS) design enables efficient and low noise operation throughout the operating range. Product Selection: 36 – 75 V DC Input Range Output Voltage Output Power (W) Current (A) Efficiency (%) Part Numbering 1.0 Vdc 100 100 85 DC048B010T010FP 1.5 Vdc 120 80 87 DC048B015T012FP 1.8 Vdc 144 80 89 DC048B018T014FP 2.5 Vdc 175 70 90 DC048B025T017FP 3.0 Vdc 180 60 91 DC048B030T018FP 3.3 Vdc 165 50 91 DC048B033T016FP 5 Vdc 180 36 91 DC048B050T018FP 10 Vdc 180 18 92 DC048B100T018FP 12 Vdc 220 18.33 92 DC048B120T022FP 15 vdc 200 13.33 92 DC048B150T020FP 24 Vdc 220 9.17 92 DC048B240T022FP 28 Vdc 190 6.79 92 DC048B280T019FP 48 Vdc 220 4.58 93 DC048B480T022FP Part Numbering D C DC-DC Converter Module 0 4 8 Input Voltage Designator Package Size B Output Voltage Designator ( = VOUT X 10 ) 0 5 0 T Product Grade Temperatures Storage T – 40 to 125°C M –65 to 125°C Operating – 40 to 100°C –55 to 100°C 0 1 8 Output Power Designator ( = POUT / 10 ) F Baseplate Pin Style F = Slotted flange T = Transverse heat sink [a] P = Through hole [a] Contact VI Brick / 48V Input DC-DC Converter Modules vicorpower.com P factory Rev. 1.1 Page 1 of 21 MODULE FAMILY ELECTRICAL CHARACTERISTICS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Absolute Maximum Ratings Parameter Rating Unit +In to –In voltage -1.0 to +85 Vdc PC to –In voltage -0.3 to +6.0 Vdc 1.0 V -0.5 to 4.0 Vdc 1.5 V -0.5 to 4.0 Vdc 1.8 V -0.5 to 4.0 Vdc 2.5 V -0.5 to 6.0 Vdc 3.0 V -0.5 to 6.0 Vdc Notes +Out to -Out 3.3 V -0.5 to 12.0 Vdc 5V -0.5 to 12.0 Vdc 10 V -0.5 to 30.0 Vdc 12 V -0.5 to 30.0 Vdc 15 V -0.5 to 25 Vdc 24 V -0.5 to 50.0 Vdc 28 V -0.5 to 48.0 Vdc 48 V -0.5 to 60.0 Vdc 2,250 Vdc Test voltage 2,250 Vdc Test voltage 707 Vdc Test voltage Isolation voltage In to out In to base Out to base Operating Temperature -55 to +100 °C M-Grade Storage Temperature -65 to +125 °C M-Grade Pin soldering temperature Mounting torque 500 (260) °F (°C) <5 sec; wave solder 750 (390) °F (°C) <7 sec; hand solder 5 (0.57) in-lbs (N-m) 6 each Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability. Input Specifications Parameter Operating input voltage Min Typ Max Unit 36 48 75 Vdc 85 Vdc 33.8 35.3 Vdc Input surge withstand Undervoltage turn-on Undervoltage turn-off 30.4 31.8 Vdc Overvoltage turn-on 75.7 77.3 Vdc Overvoltage turn-off 78.8 Recommended external input capacitance 100 VI Brick / 48V Input DC-DC Converter Modules 81.0 Notes Vdc µF vicorpower.com See Figure 19 Rev. 1.1 Page 2 of 21 MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.) Output Specifications [a] Parameter Min Typ Max Unit Output voltage setpoint 2% Line regulation ±0.5 ±1 % Temperature regulation ±0.03 .05 % / °C [a] Vout nom. Notes Nominal input; full load; 25°C Low line to high line; full load, deviation from setpoint Over operating temperature range For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474. Control Specifications Parameter Min Typ Max Unit Notes DC voltage 4.8 5.0 5.2 Vdc Referenced to –In Module disable voltage 2.3 Vdc Referenced to –In 2.6 Vdc Referenced to –In 1.90 mA Primary Control (PC) 2.4 Module enable voltage 2.5 Disable hysteresis 100 Current limit 1.75 Disable delay time mV 1 µs Thermal Resistance and Capacity Parameter Min Typ Max Unit Baseplate to sink; flat, greased surface 0.20 °C/Watt Baseplate to sink; thermal pad 0.18 °C/Watt Baseplate to ambient 6.5 °C/Watt Baseplate to ambient; 1000 LFM 2.0 °C/Watt Thermal capacity 47.7 Watt-sec/°C vicorpower.com Rev. 1.1 Thermal Impedance (°C/W) 8 7 6 5 4 3 2 1 0 0 200 400 600 800 1000 Air Velocity (LFM) Figure 1 – Thermal impedance vs. airflow VI Brick / 48V Input DC-DC Converter Modules Page 3 of 21 MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.) General Specifications Parameter Isolation voltage Unit Notes In to out Min 2,250 Typ Vdc Test voltage, complies with basic insulation requirements In to base 2,250 Vdc Test voltage, complies with basic insulation requirements 707 Vdc Test voltage, complies with operational insulation requirements 10 megohms 2.19 ounces Out to base Isolation resistance (in to out) Weight Thermal protection Agency approvals 125 130 Max 62.14 grams 135 °C Junction temperature, with automatic recovery UL60950-1, CSA0950-1, EN60950-1, IEC60950-1. With appropriate fuse in series with the +Input cTÜVus, CE Note: Specifications are subject to change without notice. VI Brick / 48V Input DC-DC Converter Modules vicorpower.com Rev. 1.1 Page 4 of 21 1.0 Vout, 100 W OPERATING SPECIFICATIONS - (e.g. DC048B010T010FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 82 85 100 1.17 5.5 ±0.6 0 108 0 115 1.0 Max Unit Notes 138 1.24 7.6 ±1.5 108,000 100 130 50 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 90 Efficiency (%) 85 80 Vin 36 V 48 V 75 V 75 70 65 60 10 20 30 40 50 60 70 80 90 100 Output Current (A) Figure 2-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 2-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 25 20 15 Vin 36 V 48 V 75 V 10 5 0 10 20 30 40 50 60 70 80 90 100 Output Current (A) Figure 2-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 2-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 120 100 80 Vin NL 60 40 20 0 0 20 40 60 80 100 Output Current (A) Figure 2-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 2-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 5 of 21 1.5 Vout, 120 W OPERATING SPECIFICATIONS - (e.g. DC048B015T012FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 83 87 100 1.75 5.5 ±0.6 0 86.4 0 92 1.0 Max Unit Notes 125 1.86 7.6 ±1.5 48,000 80 104 40 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 90 Efficiency (%) 85 80 Vin 36 V 48 V 75 V 75 70 65 60 55 50 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Output Current (A) Figure 3-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 3-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Output Current (A) Figure 3-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 3-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 90 80 70 60 50 Vin NL 40 30 20 10 0 0 20 40 60 80 Output Current (A) Figure 3-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 3-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 6 of 21 1.8 Vout, 144 W OPERATING SPECIFICATIONS - (e.g. DC048B018T014FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 86 89 87 2.33 5.5 ±0.6 0 86.4 0 92 1.0 Max Unit Notes 109 2.48 7.6 ±1.5 27,000 80 104 40 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 8 16 24 32 40 48 56 64 72 80 Output Current (A) Figure 4-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 4-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 8 16 24 32 40 48 56 64 72 80 Output Current (A) Figure 4-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 4-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 100 90 80 70 60 Vin NL 50 40 30 20 10 0 0 20 40 60 80 Output Current (A) Figure 4-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 4-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 7 of 21 2.5 Vout, 175 W OPERATING SPECIFICATIONS - (e.g. DC048B025T017FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 87 90 65 3.5 5.5 ±0.6 0 75.6 0 80.5 1.0 Max Unit Notes 95 3.71 7.6 ±1.5 12,000 70 91 35 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 7 14 21 28 35 42 49 56 63 70 Output Current (A) Figure 5-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 5-1 – Efficiency vs. load Power Dissipation vs. Output Current 24 Power Dissipation (W) 22 20 18 16 Vin 36 V 48 V 75 V 14 12 10 8 6 4 0 7 14 21 28 35 42 49 56 63 70 Output Current (A) Figure 5-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 5-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 90 80 70 60 50 Vin NL 40 30 20 10 0 0 10 20 30 40 50 60 70 Output Current (A) Figure 5-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 5-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 8 of 21 3.0 Vout, 180 W OPERATING SPECIFICATIONS - (e.g. DC048B030T018FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 88 91 56 3.5 5.5 ±0.6 0 64.8 0 69.0 1.0 Max Unit Notes 90 3.71 7.6 ±1.5 12,000 60 78.0 30 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 6 12 18 24 30 36 42 48 54 60 Output Current (A) Figure 6-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 6-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 6 12 18 24 30 36 42 48 54 60 Output Current (A) Figure 6-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 6-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 80 70 60 50 Vin NL 40 30 20 10 0 0 10 20 30 40 50 60 Output Current (A) Figure 6-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 6-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 9 of 21 3.3 Vout, 165 W OPERATING SPECIFICATIONS - (e.g. DC048B033T016FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 87 91 130 4.67 5.5 ±0.6 0 54.0 0 57.5 1.0 Max Unit Notes 163 4.95 7.6 ±1.5 6,700 50 65 25 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 5 10 15 20 25 30 35 40 45 50 Output Current (A) Figure 7-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 7-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 22 20 18 16 Vin 36 V 48 V 75 V 14 12 10 8 6 4 0 5 10 15 20 25 30 35 40 45 50 Output Current (A) Figure 7-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 7-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 140 120 100 80 Vin NL 60 40 20 0 0 10 20 30 40 50 Output Current (A) Figure 7-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 7-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 10 of 21 5.0 Vout, 180 W OPERATING SPECIFICATIONS - (e.g. DC048B050T018FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 88 91 130 7.0 5.5 ±0.6 0 38.88 0 41.4 1.0 Max Unit Notes 165 7.43 7.6 ±1.5 3,000 36 46.8 18.0 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 3.6 7.2 10.8 14.4 18 21.6 25.2 28.8 32.4 36 Output Current (A) Figure 8-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 8-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 22 20 18 16 Vin 36 V 48 V 75 V 14 12 10 8 6 4 0 3.6 7.2 10.8 14.4 18 21.6 25.2 28.8 32.4 36 Output Current (A) Figure 8-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 8-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 160 140 120 100 Vin NL 80 60 40 20 0 0 10 20 30 40 Output Current (A) Figure 8-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 8-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 11 of 21 10 Vout, 180 W OPERATING SPECIFICATIONS - (e.g. DC048B100T018FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 89 92 80 14.0 5.5 ±0.6 0 19.44 0 20.7 1.0 Max Unit Notes 125 14.85 7.6 ±1.5 750 18 23.4 9.0 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 2 4 6 8 10 12 14 16 18 Output Current (A) Figure 9-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 9-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 2 4 6 8 10 12 14 16 18 20 Output Current (A) Figure 9-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 9-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 140 120 100 80 Vin NL 60 40 20 0 0 5 10 15 20 Output Current (A) Figure 9-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 9-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 12 of 21 12 Vout, 220 W OPERATING SPECIFICATIONS - (e.g. DC048B120T022FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 87 92 160 14.0 5.5 ±0.6 0 19.80 0 21.08 1.0 Max Unit Notes 200 14.85 7.6 ±1.5 750 18.33 23.83 9.17 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 1.83 3.66 5.49 7.32 9.15 10.98 12.81 14.64 16.47 18.3 Output Current (A) Figure 10-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 10-1 – Efficiency vs. load Power Dissipation vs. Output Current 24 Power Dissipation (W) 22 20 18 16 Vin 36 V 48 V 75 V 14 12 10 8 6 4 0 5 10 15 20 Output Current (A) Figure 10-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 10-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 200 180 160 140 120 Vin NL 100 80 60 40 20 0 0 5 10 15 20 Output Current (A) Figure 10-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 10-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 13 of 21 15 Vout, 200 W OPERATING SPECIFICATIONS - (e.g. DC048B150T020FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 89 92 115 18.67 5.5 ±0.6 0 14.40 0 15.33 1.0 Max Unit Notes 144 19.8 7.6 ±1.5 423 13.33 17.33 6.67 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 1.3 2.6 3.9 5.2 6.5 7.8 9.1 10.4 11.7 13 Output Current (A) Figure 11-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 11-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 1.33 2.66 3.99 5.32 6.65 7.98 9.31 10.64 11.97 13.3 Output Current (A) Figure 11-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 11-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 140 120 100 80 Vin NL 60 40 20 0 0 5 10 15 Output Current (A) Figure 11-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 11-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 14 of 21 24 Vout, 220 W OPERATING SPECIFICATIONS - (e.g. DC048B240T022FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 87 92 108 28.0 5.5 ±0.6 0 9.90 0 10.55 1.0 Max Unit Notes 135 29.7 7.6 ±1.5 188 9.17 11.92 4.59 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 0.91 1.82 2.73 3.64 4.55 5.46 6.37 7.28 8.19 9.1 Output Current (A) Figure 12-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 12-1 – Efficiency vs. load Power Dissipation vs. Output Current 24 Power Dissipation (W) 22 20 18 16 Vin 36 V 48 V 75 V 14 12 10 8 6 4 0 2 4 6 8 10 Output Current (A) Figure 12-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 12-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 120 100 80 Vin NL 60 40 20 0 0 2 4 6 8 10 Output Current (A) Figure 12-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 12-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 15 of 21 28 Vout, 190 W OPERATING SPECIFICATIONS - (e.g. DC048B280T019FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 89 92 130 37.33 5.5 ±0.6 0 7.33 0 7.81 10 Max Unit Notes 163 39.6 7.6 ±1.5 106 6.79 8.83 3.40 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 0.67 1.34 2.01 2.68 3.35 4.02 4.69 5.36 6.03 6.7 Output Current (A) Figure 13-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 13-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 0.67 1.34 2.01 2.68 3.35 4.02 4.69 5.36 6.03 6.7 Output Current (A) Figure 13-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 13-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 120 100 80 Vin NL 60 40 20 0 0 2 4 6 8 Output Current (A) Figure 13-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 13-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 16 of 21 48 Vout, 220 W OPERATING SPECIFICATIONS - (e.g. DC048B480T022FP) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Output capacitance Load current Current limit (peak) Short circuit current (avg) Min Typ 90 93 160 56.0 5.5 ±0.6 0 4.95 0 5.27 1.0 Max Unit Notes 200 59.4 7.6 ±1.5 47 4.58 5.95 2.29 % mV Volts Watts % µF Amps Amps Amps Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (1 minute off) No load No load to full load; nominal input, deviation from setpoint External Shut down, may require PC enable to initiate restart Shut down, may require PC enable to initiate restart Efficiency vs. Output Current 95 Efficiency (%) 90 85 Vin 36 V 48 V 75 V 80 75 70 65 0 0.45 0.9 1.35 1.8 2.25 2.7 3.15 3.6 4.05 4.5 4.95 Output Current (A) Figure 14-4 – Transient response 100 – 50%, 3 x 4.7 µF ceramic bypass capacitance Figure 14-1 – Efficiency vs. load Power Dissipation vs. Output Current Power Dissipation (W) 20 18 16 14 Vin 36 V 48 V 75 V 12 10 8 6 4 0 0.45 0.9 1.35 1.8 2.25 2.7 3.15 3.6 4.05 4.5 4.95 Output Current (A) Figure 14-5 – Transient response 50 – 100%, 3 x 4.7 µF ceramic bypass capacitance Figure 14-2 – Power dissipation vs. load Ripple vs. Output Current Output Ripple (mVpk-pk) 160 140 120 100 Vin NL 80 60 40 20 0 0 1 2 3 4 5 Output Current (A) Figure 14-3 – Output ripple vs. load with no external bypass capacitance VI Brick / 48V Input DC-DC Converter Modules Figure 14-6 – Output voltage ripple at nominal line and full load with no external bypass capacitance. vicorpower.com Rev. 1.1 Page 17 of 21 PIN / CONTROL FUNCTIONS +In / -In DC Voltage Ports The maximum input voltage should not be exceeded. The modules have internal over / undervoltage lockout functions that prevent operation outside of the specified input range. They will turn on when the input voltage rises above its undervoltage lockout. If the input voltage exceeds the overvoltage lockout, the module will shut down until the overvoltage fault clears. PC will toggle indicating an out of bounds condition. PC – Primary Control The output voltage is enabled when the PC pin is open circuit (floating). To disable the module’s output voltage, the PC pin is pulled low (referenced to –IN). Open collector optocouplers, transistors, or relays can be used to control the PC pin. During an abnormal condition the PC pin will pulse (Figure 17) as the module initiates a restart cycle. This will continue until the abnormal condition is rectified. The PC pin should not be used as an auxiliary voltage supply, nor should it be switched at a rate greater than 1 Hz. Figure 17 — PC module alarm logic Figure 18 — Pin configuration (as viewed from pin side) Figure 15 — Nominal line full load, turn on delay, Vin vs. Vout Disable Figure 16 — Module enable/disable. VI Brick / 48V Input DC-DC Converter Modules vicorpower.com Rev. 1.1 Page 18 of 21 PIN / CONTROL FUNCTIONS (CONT.) Scope Probe Jack 100 µF Electrolytic Capacitor + 4.7 µF Ceramic + To Vsource — — L O A D For agency approvals and fusing conditions, click on the link below: http://www.vicorpower.com/technical_library/technical_documentation/quality_and_certification/safety_approvals/ Figure 19 — Test set-up diagram for input and output ripple. VI Brick / 48V Input DC-DC Converter Modules vicorpower.com Rev. 1.1 Page 19 of 21 MECHANICAL DRAWINGS Baseplate – Slotted Flange Heat Sink (Longitudinal) Note: RoHS COMPLIANT PER CST-001 LATEST REVISION Figure 20 — Module outline Recommended PCB Pattern (Component side shown) Note: RoHS COMPLIANT PER CST-001 LATEST REVISION Figure 21 — PCB mounting specifications VI Brick / 48V Input DC-DC Converter Modules vicorpower.com Rev. 1.1 Page 20 of 21 Warranty Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages. Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual Property Department. The products described on this data sheet are protected by the following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,788,033; 6,940,013; 6,969,909; 7,038,917; 7,154,250; 7,166,898; 7,187,263; 7,202,646; D496,906; D506,438; D509,472; 6,911,848; 6,930,893; 6,934,166; 7,145,186; D505,114; and for use under 6,975,098 and 6,984,965 Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] VI Brick / 48V Input DC-DC Converter Modules vicorpower.com Rev. 1.1 10/08