Meder MK15-E-2 Reed sensors for smd mounting Datasheet

MK15 Series
MEDER electronic
Reed Sensors for
SMD Mounting
DESCRIPTION
MK15 are magnetically operated Reed proximity
switches for SMD mounting.
• • Lead design 1: Flat, straight leads for PCB slot
mounting.
• • Lead design 2: Flat, bent SMD leads.
The sensors are supplied taped & reeled according
to IEC 286/part 3 suitable for auto-placement. The
special features of this series are the small dimensions
of only 19.5 x 2.5 x 2.5mm and the simple internal
structure (low-cost version).
APPLICATIONS
• Electronic PCB’s where all components are
surface mounted
• Telecommunication applications Hook switch in
mobile and hard-wired phones
• Switching element in microphones
FEATURES
•
•
•
•
•
•
Excellent for low power operations
High power switches available
Six operate sensitivities available
Tape and Reel available
No external power required for sensor operation
UL approved
DIMENSIONS
All dimensions in mm [inch]
ORDER INFORMATION
MAGNETIC SENSITIVITY
Sensitivity
class
Pull In
AT Range
B
10 - 15
C
15 - 20
D
20 - 25
E
25 - 30
F
30 - 35
G
35 - 40
Part Number Example
MK15 - B - 1
B is the magnetic sensitivity
1 is the lead design
www.meder.com
254
Series
Magnetic
Sensitivity
Lead
Design
MK15 -
x-
x
Options
B, C, D, E, F, G
1.2
MEDER electronic
MK15 Series
Reed Sensors for
SMD Mounting
TAPE & REEL
SOLDERING INFORMATION
reflow soldering conditions according JEDEC norm J-STD-020C
40 s
260 oC
183 oC
125 oC
Ramp up:
max. 6K/s
120 s
120-180 s
Ramp down:
max. 8/Ks
www.meder.com
255
MEDER electronic
MK15 Series
Reed Sensors for
SMD Mounting
CONTACT DATA
All Data at 20° C
Contact Form →
Contact Ratings
Conditions
Form A
Min.
Typ.
Max. Units
Switching Power
Any DC combination of V & A not to
exceed their individual max.‘s
10
W
Switching Voltage
DC or peak AC
200
V
Switching Current
DC or peak AC
0.5
A
Carry Current
DC or peak AC
1.25
A
Static Contact Resistance
w/ 0.5 V & 10 mA
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure
200
mΩ
Insulation Resistance across Contacts
100 volts applied
1012
Ω
Breakdown Voltage across Contact
Voltage applied for 60 sec. min.
225
VDC
Operate Time incl. Bounce
Measured w/ 100 % overdrive
0.5
ms
Release Time
Measured w/ no coil suppression
0.1
ms
Capacitance
at 10 kHz cross contact
0.2
pF
Contact Operation *
Must Operate Condition
Steady state field
10
30
AT
Must Release Condition
Steady state field
4
27
AT
Environmental Data
Shock Resistance
1/2 sinus wave duration 11 ms
30
g
Vibration Resistance
From 10 - 2000 Hz
20
g
Ambient Temperature
10°C/ minute max. allowable
-40
130
o
C
Stock Temperature
10°C/ minute max. allowable
-50
130
o
C
Soldering Temperature
5 sec. dwell
260
o
C
Please note: The indicated electrical data are maximum values and can vary downwards when using a more
sensitive switch.
* These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if
more detail is required.
www.meder.com
256
Similar pages