Specification
AXHV1011
Oscillator type :
VCO – Voltage Controlled Oscillator
Parameter
min.
typ.
max.
Unit
Date: 2005-12-08
Condition
820
1175
MHz
@ 25°C
Frequency tuning range
Frequency adjustment range
EFC voltage VC
0
6
V
25
80
MHz/V
Tuning sensitivity (∆f / ∆VC)
EFC slope
positive
Frequency stability
vs. supply voltage variation (pushing)
1
MHz/V
vs. load change (pulling)
1
MHz
@ ar =12 dB
RF output
Signal waveform
SINUS
Amplitude
+2
+3.7
dBm
RL = 50 Ω
Harmonics
-14
dBc
-105
dBc/Hz @ 100 kHz
Phase Noise
Supply voltage VS
4.75
5
5.25
V
Current consumption (steady state)
20
mA
-10
+60
°C
Operating temperature range
-20
+70
°C
Operable temperature range
-40
+85
°C
Storage temperature range
25.4 x 12.7 x 6.1.
mm
Enclosure (see drawing) LxWxH
5
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXHV1011
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency Range [MHz]
820-1175
AXHV1011
page 1(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing on request
Pin connections
Output circuit:
Pin # Symbol
P1
VC
P2 RF OUT
P3
VS
P4
N.C.
All
GND
others
OUT
Function
Control Voltage (EFC)
RF Output
Supply Voltage
Not Connected
Ground
Typical performance
HV1011
f/MHz
1200
1150
1100
1050
1000
950
900
850
800
0
1
2
3
4
5
6
V_tune/V
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV1011
page 2(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Sensitivity(MHz/V)
HV1011
100
80
60
40
20
0
0
1
2
3
4
5
6
V_tune/V
HV1011
P_out/dBm
5
0
P_out/dBm
P_out_1st_Harmonic/dBm
-5
-10
-15
-20
0
1
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
2
3
V_tune/V
4
AXHV1011
page 3(4)
5
6
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV1011
page 4(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]