R Long Barrel Inductive Prox E2E2 3-Wire DC Rugged Inductive Prox Sensors Meet IP67 Requirements H Solid potted internal circuitry withstands shocks and water washdown to IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H High visibility indicator H Connector and prewired versions Ordering Information J PRE-WIRED SENSORS Type yp Size Shielded M12 M18 Sensing g distance 2 mm 5 mm M30 Unshielded M12 10 mm 5 mm M18 10 mm M30 18 mm Part number Output p NO NC NPN E2E2-X2C1 E2E2-X2C2 PNP E2E2-X2B1 E2E2-X2B2 NPN E2E2-X5C1 E2E2-X5C2 PNP E2E2-X5B1 E2E2-X5B2 NPN E2E2-X10C1 E2E2-X10C2 PNP E2E2-X10B1 E2E2-X10B2 NPN E2E2-X5MC1 E2E2-X5MC2 PNP E2E2-X5MB1 E2E2-X5MB2 NPN E2E2-X10MC1 E2E2-X10MC2 PNP E2E2-X10MB1 E2E2-X10MB2 NPN E2E2-X18MC1 E2E2-X18MC2 PNP E2E2-X18MB1 E2E2-X18MB2 J SENSORS WITH M12 CONNECTORS Type yp Size Shielded M12 M18 M30 Unshielded M12 M18 Sensing g distance 2 mm 5 mm 10 mm 5 mm 10 mm M30 18 mm Part number Output p NO NC NPN E2E2-X2C1-M1 E2E2-X2C2-M1 PNP E2E2-X2B1-M1 E2E2-X2B2-M1 NPN E2E2-X5C1-M1 E2E2-X5C2-M1 PNP E2E2-X5B1-M1 E2E2-X5B2-M1 NPN E2E2-X10C1-M1 E2E2-X10C2-M1 PNP E2E2-X10B1-M1 E2E2-X10B2-M1 NPN E2E2-X5MC1-M1 E2E2-X5MC2-M1 PNP E2E2-X5MB1-M1 E2E2-X5MB2-M1 NPN E2E2-X10MC1-M1 E2E2-X10MC2-M1 PNP E2E2-X10MB1-M1 E2E2-X10MB2-M1 NPN E2E2-X18MC1-M1 E2E2-X18MC2-M1 PNP E2E2-X18MB1-M1 E2E2-X18MB2-M1 2 E2E2 3-Wire DC E2E2 3-Wire DC J ACCESSORIES Description Part number Mounting brackets Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-B12 Y92E-B18 Y92E-B30 Silicone rubber covers for shielded sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-E12-2 Y92E-E18-2 Y92E-E30-2 Connector cordsets See Y96E Connector Cordsets data sheet for details J REPLACEMENT PARTS Description Part number Mounting hardware including one pair of metal nuts and one washer Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors M12-MHWS M18-MHWS M30-MHWS Specifications Part number E2E2-X2Cj/Bj Size M12 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 2 mm (0.08 in) ±10% 5 mm (0.20 in) ±10% 5 mm (0.20 in) ±10% 10 mm (0.39 in) ±10% 10 mm (0.39 in) ±10% 18 mm (0.71 in) ±10% Supply voltage (operating voltage range) 12 to 24 VDC, ripple (p-p): 10% max., (10 to 55 VDC) Current consumption 13 mA max. Sensing object Magnetic metals (refer to Engineering Data for non-magnetic metals) Setting distance 0 to 1.6 mm (0 to 0.06 in) 0 to 4.0 mm (0 to 0.16 in) 0 to 4.0 mm (0 to 0.16 in) 0 to 8.0 mm (0 to 0.31 in) 0 to 8.0 mm (0 to 0.31 in) 0 to 14.0 mm (0 to 0.55 in) Standard object (mild steel) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 15 x 15 x 1 mm (0.59 x 0.59 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in) Differential travel 10% max. of sensing distance Response frequency 1.5 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz Operation (with sensing object approaching) B1/C1 models: Load ON B2/C2 models: Load OFF Control output (switching capacity) 200 mA max., open collector Circuit protection Reverse connection protection, surge absorber, load short-circuit protection Indicator Operation indicator (red LED) E2E2-X5MCj/Bj E2E2-X5Cj/Bj E2E2-X10MCj/Bj M18 0.4 kHz Ambient temperature Operating --40°C to 85°C (--40°F to 185°F) with no icing Ambient humidity Operating 35% to 95% E2E2-X10Cj/Bj E2E2-X18MCj/Bj M30 Temperature influence ±15% max. of sensing distance at 23°C in temperature range of --40°C to 85°C (--40°F to 185°F) ±10% max. of sensing distance at 23°C in temperature range of --25°C to 70°C (--13°F to 158°F) Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Residual voltage 2.0 V max. (under load current of 200 mA with cable length of 2 m) Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC for 1 min between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 10 times each in X, Y, and Z axes Shock resistance 1,000 m/s2 (approx. 100G) for 10 times each in X, Y, and Z axes (This table continues on the next page.) 3 E2E2 3-Wire DC E2E2 3-Wire DC Specifications Table -- continued from previous page Part number Enclosure rating E2E2-X2Cj/Bj IEC IP67 NEMA 1, 4, 6, 12, 13 Weight Material E2E2-X5MCj/Bj 75 g E2E2-X5Cj/Bj E2E2-X10MCj/Bj E2E2-X10Cj/Bj 160 g Body Brass Sensing face PBT 220 g Operation J OUTPUT CIRCUITS E2E2-XjCj DC 3-wire Models E2E2-XjBj DC 3-wire Models Brown 1 Brown 1 +V 100 Ω +V Load Black Main circuit Black 4 (or 2) Main circuit 4 (or 2) Load Blue 3 100 Ω 0V J TIMING CHART E2E2-XjCj/Bj DC 3-wire Models NPN/PNP Open Collector Output Sensing object Control output Red indicator Yes No ON OFF Lit Not lit Engineering Data J OPERATING RANGE (TYPICAL) Shielded Models E2E2-XjCj/Bj Sensing distance X (mm) Sensing distance X (mm) E2Ej-X10j E2Ej-X2j E2Ej-X5j Y (mm) Y (mm) 4 Blue 3 0V E2E2-X18MCj/Bj E2E2 3-Wire DC E2E2 3-Wire DC Unshielded Models E2E2-XjMCj/Bj Sensing distance X (mm) Sensing distance X (mm) E2Ej-X5Mj E2Ej-X18Mj E2Ej-X10Mj Y (mm) Y (mm) J SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) E2E2-X10MCj/Bj Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) 5 Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) E2E2-X18MCj/Bj Mild steel Sensing distance (mm) Sensing distance (mm) E2E2-X5MCj/Bj Mild steel Sensing distance (mm) Sensing distance (mm) Mild steel E2E2-X10Cj/Bj Sensing distance (mm) E2E2-X5Cj/Bj Sensing distance (mm) E2E2-X2Cj/Bj Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) E2E2 3-Wire DC E2E2 3-Wire DC Dimensions Unit: mm (inch) J PRE-WIRED SENSORS E2E2-X2jj E2E2-X5Mjj 60 (2.36) 55 (2.17) 21 dia. (0.83) 21 dia. (0.83) 60 (2.36) 55 (2.17) 7 (0.28) 9 dia. M12 × 1 Operation indicator Two clamping nut Round vinyl-insulated cable 4 dia. (0.08 dia. x 60) Toothed washer 2/3 cores Standard length: 2 m E2E2-X5jj Operation indicator M12 × 1 Two clamping nut Toothed washer Round vinyl-insulated cable 4 dia. (0.08 dia. x 60) 2/3 cores Standard length: 2 m E2E2-X10Mjj 65 (2.56) 60 (2.36) 29 dia. (1.14) 29 dia. (1.14) 65 (2.56) 60 (2.36) 10 (0.39) 14.8 dia. Operation indicator M18 × 1 Two clamping nut Toothed washer Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m M18 × 1 Operation indicator Two clamping nut Round vinyl-insulated cable Toothed washer 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m E2E2-X10jj 70 (2.76) 42 dia. (1.65) 65 (2.56) Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m Operation indicator M30 × 1.5 Two clamping nut Toothed washer E2E2-X18Mjj 42 dia. (1.65) 70 (2.76) 65 (2.56) 13 (0.51) 26.8 dia. Operation indicator M30 × 1.5 Two clamping nut Toothed washer 6 Round vinyl-insulated cable 6 dia. (0.12 dia. x 45) 2/3 cores Standard length: 2 m E2E2 3-Wire DC E2E2 3-Wire DC J SENSORS WITH M12 CONNECTORS E2E2-X5MCj-M1/Bj-M1 E2E2-X2Cj-M1/Bj-M1 70 (2.76) 21 dia. (0.83) 17 55 (2.17) 4 M12 x 1 10 70 (2.76) 21 dia. (0.83) 55 (2.17) 7 (0.28) 17 9 dia. Operation indicator M12 x 1 M12 x 1 10 4 Operation indicator M12 x 1 Two clamping nut Two clamping nut Toothed washer Toothed washer E2E2-X5Cj-M1/Bj-M1 E2E2-X10MCj-M1/Bj-M1 75 (2.95) 29 dia. (1.14) 60 (2.36) 24 4 60 (2.36) 24 M12 x 1 10 10 (0.39) 4 10 14.8 dia. Operation indicator M18 x 1 75 (2.95) 29 dia. (1.14) Operation indicator M18 x 1 Two clamping nut Two clamping nut Toothed washer Toothed washer E2E2-X10Cj-M1/Bj-M1 E2E2-X18MCj-M1/Bj-M1 80 (3.15) 42 dia. (1.65) 5 80 (3.15) 42 dia. (1.65) 65 (2.56) 36 M12 x 1 10 65 (2.56) 13 (0.51) 36 5 10 26.8 dia. M12 x 1 M30 x 1.5 M12 x 1 Operation indicator Two clamping nut Toothed washer Operation indicator M30 x 1.5 Two clamping nut Toothed washer J MOUNTING HOLES F Dimensions M12 M18 M30 F (mm) 12.5 (0.49) dia. 18.5 (0.73) dia. 30.5 (1.20) dia. 7 E2E2 3-Wire DC E2E2 3-Wire DC Installation J PIN ARRANGEMENT E2E2-XjBj-M1 DC 3-wire Models Output configuration Applicable models NO E2E2-XjB1-M1 Pin arrangement Load Note: Terminal 2 is not used. Note: Terminal 2 is not used. Note: Terminal 4 is not used. Note: Terminal 4 is not used. E2E2-XjC1-M1 Load NC E2E2-XjB2-M1 Load E2E2-XjC2-M1 Load Precautions J MOUNTING Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Part B Part A Note: Unshielded Model Part B Part A 8 The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. Type Torque M12 30 N S m (310 kgf S cm) M18 70 N S m (710 kgf S cm) M30 180 N S m (1,800 kgf S cm) E2E2 3-Wire DC E2E2 3-Wire DC J EFFECTS OF SURROUNDING METAL When mounting the E2E2 within a metal panel, ensure that the clearances given in the table below are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. d dia. Type Dimension M12 M18 M30 Shielded ℓ 0 mm 0 mm 0 mm d 12 mm 18 mm 30 mm D 0 mm 0 mm 0 mm m 8 mm 20 mm 40 mm n 18 mm 27 mm 45 mm ℓ 15 mm 22 mm 30 mm d 40 mm 55 mm 90 mm D 15 mm 22 mm 30 mm m 20 mm 40 mm 70 mm n 36 mm 54 mm 90 mm Unshielded J MUTUAL INTERFERENCE A B When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. Type Dimension M12 M18 M30 Shielded A 30 mm 50 mm 100 mm B 20 mm 35 mm 70 mm A 120 mm 200 mm 300 mm B 100 mm 110 mm 200 mm Unshielded Cable Tractive Force Do not pull cables with the tractive forces exceeding these specs. J INSTALLATION Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF Diameter Tractive force 4 mm dia. max. 30 N max. 4 mm dia. min. 50 N max. J MOUNTING The Proximity Sensor may output a pulse signal when it is turned off. Turn off the load before turning off the Proximity Sensor. The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, or the Proximity Sensor may be damaged or lose its water-resistance. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. J ENVIRONMENT Target Object Water Resistance Do not use the Proximity Sensor underwater, outdoors, or in the rain. Metal Coating The sensing distances of the Proximity Sensor vary with the metal coating on target objects. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistant, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). J WIRING High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. 9 E2E2 3-Wire DC E2E2 3-Wire DC NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A.