IRF IRUD400CW60 Ultrafast, soft recovery diode Datasheet

Bulletin PD-21047 05/05
IRUD400CW60
FRED TM
Ultrafast, Soft Recovery Diode
Features
LUG
TERMINAL
ANODE 1
• Ultrafast Recovery
• Lead-Free
LUG
TERMINAL
ANODE 2
Benefits
•
•
•
•
VR = 600V
IF(AV) = 400A
Reduced RFI and EMI
Higher Frequency Operation
Reduced Snubbing
Reduced Parts Count
BASE COMMON CATHODE
Description/ Applications
These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The
softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited
for HF welding, power converters and other applications where switching losses are significant portion of the total
losses.
Absolute Maximum Ratings
Parameters (*)
VR
Cathode-to-Anode Voltage
IF(AV)
Continuous Forward Current
Max
Units
600
V
@ TC = 25°C
330
A
@ TC = 85°C
230
@ TC = 97°C
IFSM
Single Pulse Forward Current
PD
Maximum Power Dissipation
200
1200
@ TC = 25°C
660
@ TC = 97°C
280
W
Case Styles
IRUD400CW60
TO-244
(*) Per Leg unless otherwise specified
1
IRUD400CW60
Bulletin PD-21047 05/05
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameters
Min Typ Max Units Test Conditions
VBR
Breakdown Voltage,
600
-
-
VFM
Forward Voltage
-
1.45
2.0
IF = 200A
-
1.67
2.3
IF = 400A
-
1.13
1.4
IF = 200A @ TJ = 150°C
-
1.39
1.8
IF = 400A @ TJ = 150°C
V
IR = 100µA
IRM
Reverse Leakage Current
-
0.3
1.38
mA
TJ = 150°C, VR = VR Rated
LS
Series Inductance
-
5
-
nH
from top of terminal hole to mounting plane
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr
IRRM
Qrr
Min Typ Max Units Test Conditions
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
-
90
-
-
240
-
-
8.3
-
-
24
-
-
830
-
-
4730
-
ns
If = 200A, dif/dt = 200A/µs, Vr = 200V
If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C
A
If = 200A, dif/dt = 200A/µs, Vr = 200V
If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C
nC
If = 200A, dif/dt = 200A/µs, Vr = 200V
If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C
Thermal - Mechanical Characteristics
Parameters
Min
Typ
Max
Units
°C
TJ
Max. Junction Temperature Range
- 40
-
150
TStg
Max. Storage Temperature Range
- 40
-
150
RthJC
Thermal Resistance, Junction to Case
Per Leg
-
-
0.19
Thermal Resistance, Junction to Case
Per Module
-
-
0.095
-
°C/W
RthCS
Thermal Resistance, Case to Heatsink
-
0.10
Wt
Weight
-
68 (2.4)
-
T
Mounting Torque
30 (3.4)
-
40 (4.6)
lbf.in
Mounting Torque Center Hole
12 (1.4)
-
18 (2.1)
(N.m)
Terminal Torque
2
30 (3.4)
-
40 (4.6)
Vertical Pull
-
-
80
2 inch. Lever Pull
-
-
35
g (oz)
lbf.in
IRUD400CW60
Bulletin PD-21047 05/05
1000
Reverse Current - IR (µA)
100
TJ = 150˚C
100
10
1
25˚C
0.1
0.01
0
100 200 300 400 500
Reverse Voltage - VR (V)
600
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage (per Leg)
160
10
Tj = 150˚C
Tj = 25˚C
1
0
0.5
1
1.5
Forward Voltage Drop - VFM (V)
2
Allowable Case Temperature (°C)
Instantaneous Forward Current - IF (A)
1000
IRUD400CW60
RthJC = 0.19 K/W
140
120
DC
(D = 0.50)
100
80
60
0
Fig. 1 - Typical Forward Voltage Drop
vs. Instantaneous Forward Current (per Leg)
50
100
150
200
Current Rating - IDC (A)
250
Fig. 3 - Max. Current Rating Capability
(per Leg)
3
IRUD400CW60
Bulletin PD-21047 05/05
300
If = 200A
Vrr = 200V
RMS Limit
150
DC
200
100
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
50
Tj = 150˚C
t rr (ns)
Forward Power Loss (W)
200
100
0
0
50
100
150
Tj = 25˚C
200
Forward Current (A)
Fig. 4 - Typical Recovery Current vs. dif /dt
(per Leg)
0
100
200
300
400
500
dif/ dt - (A/µs)
Fig. 5 - Typical Reverse Recovery Time
vs. dif /dt (per Leg)
8000
40
If = 200A
Vrr = 200V
If = 200A
Vrr = 200V
6000
30
Tj = 150˚C
I RR (A)
Q RR (nC)
Tj = 150˚C
4000
2000
20
10
Tj = 25˚C
Tj = 25˚C
0
100
4
200
300
400
500
0
100
200
300
400
500
dif/ dt - (A/µs)
dif/ dt - (A/µs)
Fig. 6 - Typical Reverse Recovery Charge
vs. dif /dt (per Leg)
Fig. 7 - Typical Reverse Recovery Current
vs. dif /dt (per Leg)
IRUD400CW60
Bulletin PD-21047 05/05
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
D
di F /dt
dif/dt
ADJUST
G
IRFP250
S
Fig. 8 - Reverse Recovery Parameter Test Circuit
Outline Table
Conforms to JEDEC Outline TO-244
Dimensions in millimeters and (inches)
5
IRUD400CW60
Bulletin PD-21047 05/05
Ordering Information Table
Device Code
IR
UD
400
C
W
60
1
2
3
4
5
6
1
-
International Rectifier
2
-
UD = Fred
3
-
Current Rating (400 = 400A)
4
-
Circuit Configuration (C = Common Cathode)
5
-
W = TO-244 Wire Bondable not Isolated
6
-
Voltage Rating (60 = 600V)
Data and specifications subject to change without notice.