Keysight M9420A M9300a pxie frequency reference Datasheet

Keysight Technologies
M9300A PXIe Frequency Reference
Data Sheet
Overview
Product Description
The Keysight Technologies, Inc. M9300A PXIe frequency reference is a PXIe modular instrument that
can be used as a 10 MHz or 100 MHz reference in
various solutions. A single M9300A can be shared
with up to four PXI VSAs, VSGs or VXTs in one chassis, as shown in Figure 1, to form a multi-channel
solution.
Instrument control is provided through a soft front
panel and programmatic interfaces tuned to your
application development environment of choice.
Product Features
–– Locks to another reference with a value from
1 to 110 MHz.
–– Five 100 MHz outputs
–– One 10 MHz output
–– Internal 10 MHz OCXO timebase output
Uncompromising Values
–– Reduces development time and simplifies
integration into existing test environments with
multiple drivers and programmatic interfaces.
–– Reduces startup time with Keysight IO libraries
easy con-figuration, one-step software install,
and soft front panel.
–– Fast repair turnaround time with Calibrated
Core Exchange strategy.
Figure 1. M9300A PXIe Frequency Reference inserted in slot 10, above, can be
shared with four M9393A PXIe Vector Signal Analyzers in one chassis.
03 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Technical Specifications and Characteristics
Block diagram
M9300A PXIe Frequency Reference
(+13 dBm sine
all 100 MHz Outs)
100 MHz
Out 1
100 MHz PLL
100 MHz
Out 2
(1 to 110 MHz)
Ref In
100 MHz
Out 3
100 MHz
100 MHz
Out 4
10 MHz OCXO
TIMEBASE
100 MHz
Out 5
Divide 10 MHz
by 10
10 MHz
10 MHz Out
OXCO Out
(10 MHz, +10 dBm
to 16 dBm, sine)
Figure 2. M9300A PXIe frequency reference block diagram.
Definitions for specifications
Temperatures referred to in this document are defined as follows:
–– Operating ambient temperature = 0 to 55 ° C and individual
module temperature of ≤ 75 ° C
–– Room temperature = 20 to 30 ° C and individual module
temperature of ≤ 55 ° C
Specifications describe the warranted performance of
calibrated instruments. Data represented in this document
are specifications unless otherwise noted.
Specifications are warranted under the following conditions:
–– Calibrated instruments that have been stored for a minimum
of 2 hours within the operating ambient temperature range
–– 30 minute warm-up time
–– Calibration cycle maintained
Characteristics describe product performance that is useful in
the application of the product. Characteristics are often referred
to as Typical or Nominal values and are italicized.
–– Typical describes characteristic performance, which 80% of
instruments will meet when operated at room temperature.
–– Nominal describes representative performance that is useful
in the application of the product when operated at room
temperature.
Note: All graphs contain measured data from several units at
room temperature unless otherwise noted.
Recommended best practices in use
–– Use slot blockers and EMC filler panels in empty module
slots to ensure proper operating temperatures.
–– Keysight chassis and slot blockers optimize module
temperature performance and reliability of test.
–– At operating ambient temperatures above 45 °C, chassis
fan should be set to high.
04 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Technical Specifications and Characteristics (continued)
Reference outputs
100 MHz Out (Out 1 through Out 5)
Amplitude
≥ 10 dBm, 13 dBm, typical
Connectors
5 SMB snap-on
Impedance
50 Ω, nominal
10 MHz Out
Amplitude
9.5 dBm, nominal
Connectors
1 SMB snap-on
Impedance
50 Ω, nominal
OCXO Out
Amplitude
11.5 dBm, nominal
Connectors
1 SMB snap-on
Impedance
50 Ω, nominal
05 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Technical Specifications and Characteristics (continued)
Frequency accuracy
Same as accuracy of internal time base or external reference input
Internal timebase
Accuracy
± (time since last adjustment x aging rate)
± temperature effects
± calibration accuracy
Frequency stability - Aging rate
Daily
< ± .5 ppb/day, after 72 hour warm-up, nominal
Yearly
< ± .10 ppm/year, after 72 hours warm-up, nominal
Total 10 years
< ± 0.6 ppm/10yrs, after 72 hours warm-up, nominal
Achievable initial calibration accuracy (at time of shipment)
± 5 x 10 -8
Frequency stability - Temperature effects
20 to 30 °C
< ± 10 ppb, nominal
Full temperature range
< ± 50 ppb, nominal
Frequency stability - warm up
5 minutes over +20 to +30 °C, with respect to 1 hour
< ± 0.1 ppm, nominal
15 minutes over +20 to +30 °C, with respect to 1 hour
< ± 0.01 ppm, nominal
External reference input
Frequency
1 MHz to 110 MHz, sine wave
Lock range
± 1 ppm, nominal
Amplitude
0 to 10 dBm, nominal
Connector
1 SMB snap-on
Impedance
50 Ω, nominal
06 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Technical Specifications and Characteristics (continued)
Environmental and physical specifications
Temperature
Operating
Non-Operating (Storage)
0 to 55 °C
–40 to +70 °C
Humidity 1
Type tested at 95%, +40 °C (non-condensing)
Altitude
Up to 15,000 feet (4,572 meters)
EMC
Complies with European EMC Directive 2004/108/EC
–– IEC/EN 61326-2-1
–– CISPR Pub 11 Group 1, class A
–– AS/NZS CISPR 11
–– ICES/NMB-001
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
Warm-up time
30 minutes
Size
1 PXIe slot
Dimensions
Length 210 mm, Width 22 mm, Height 130 mm
Weight
0.551 kg (1.215 lbs)
Power drawn from chassis
≤ 18 W
System requirements
Operating systems
Windows 7 (32-bit and 64-bit)
Processor speed
1 GHz 32-bit (x86), 1 GHz 64-bit (x64)
(no support for Itanium 64)
Available memory
4 GB minimum
8 GB or greater recommended
Available disk space 2
1.5 GB available hard disk space, includes:
–– 1 GB available for Microsoft .NET Framework 3.5 SP1
–– 100 MB for Keysight IO Libraries Suite
Video
Support for DirectX 9 graphics with 128 MB graphics
memory recommended
(Super VGA graphics is supported)
Browser
Microsoft Internet Explorer 7.0 or greater
1.
Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the
environmental stresses of Storage, Transportation and End-use; those stresses include but are not limited to temperature, humidity, shock, vibration,
altitude and power line conditions. Test Methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3.
2. NET framework runtime components are installed by default with Windows 7. Therefore, you may not need this amount of available disk space.
07 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Software
Instrument connection software
Keysight IO
Library
The Suite offers a single entry point for connection to the most
common instruments including AXIe, PXI, GPIB, USB, Ethernet/LAN,
RS-232, and VXI test instruments from Keysight and other vendors.
It automatically discovers interfaces, chassis, and instruments. The
graphical user interface allows you to search for, verify and update
IVI instrument and soft front panel drivers for modular and traditional
instruments. The Suite safely installs in side-by-side mode with
NI I/O software.
Free software download at
www.keysight.com/find/iosuite
The PXI module includes a Soft Front Panel (SFP), a software-based
Graphical User Interface (GUI) which enables the instrument’s
capabilities from your PC.
Included on CD-ROM shipped with module
or online
Module setup and usage
Keysight Soft
Front Panel
Programming
Driver
Development environments
lVI-COM
IVI-C
LabVIEW
MATLAB
Visual Studio
(VB.NET, C#, C/C++)
VEE
LabVIEW, LabWindows/CVI, MATLAB
Included on CD-ROM shipped with module
or online
Assists in finding the right instrument commands and setting correct
parameters. A simple interface includes documentation, examples,
syntax checking, command execution and debug tools to build
sequences for integration in Excel, MATLAB, Visual Studio, LabVIEW,
VEE, SystemVue.
Free software download at
www.keysight.com/find/commandexpert
Programming assitance
Command
Expert
Calibration and traceability
Factory Calibration
The M9300A PXIe Frequency Reference ships factory calibrated with an ISO9002, NIST-traceable calibration certificate.
Calibration Cycle
A one year calibration cycle is recommended
Included in base
configuration
Calibration Sites
–– At Keysight’s Worldwide Service Centers
–– On-site by Keysight
–– By self-maintainers
More information visit
www.keysight.com/find/infoline
R1282A Annual
Calibration Service
–– Keysight Calibration
–– Keysight Calibration + Uncertainties
–– Keysight Calibration + Uncertainties + Guardbanding
–– Standards Compliance
–– ANSI Z540.3-2006, ISO 17025:2005, ANSI Z540-1-1994, ISO 9001:2008
Additional service, not included in the
warranty
N7800A Calibration
and Adjustment
Software
The M9300A is supported by Keysight’s Calibration and
Adjustment Software. This is the same software used at Keysight Service
Centers to automate calibration. The software offers compliance tests for
ISO 17025:2005, ANSI/NCSL Z540.3-2006, and measurement uncertainty
per ISO Guide to Expression of Measurement Uncertainty.
Licensed software.
For more information, visit
www.keysight.com/find/calibrationsoftware
Keysight Calibration
Status Utility
The Keysight Calibration Status utility helps ensure your M9300A is calibrated
by managing the calibration interval and providing messages regarding
instrument and module calibration status.
Included in base configuration
08 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Support
Support
Core Exchange
Program
Keysight’s Replacement Core Exchange program allows fast and easy module
repairs. A replacement core assembly is a fully functioning pre-calibrated
module replacement that is updated with the defective module serial number,
allowing the replacement module to retain the original serial number.
For qualified self-maintainers in US only
Self-Test Utility
A self-test utility runs a set of internal tests which verifies the health of the
modules and reports their status.
Included in base configuration
09 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Configuration and Ordering Information
Ordering Information
Accessories
Model
Description
Model
Description
M9300A
PXIe Frequency Reference
Includes:
Software, example programs and product
information on CD
Y1212A
Slot Blocker Kit: 5 modules
Y1213A
PXI EMC Filler Panel Kit: 5 slots
Y1214A
Air Inlet Kit: M9018A 18-slot chassis
Y1215A
Rack Mount Kit: M9018A 18-slot chassis
Software Information
Supported operating
systems
Microsoft Windows 7 (32/64-bit)
Standard compliant
drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application
development
environments (ADE)
VisualStudio (VB.NET, C#, C/C++), VEE,
LabVIEW, LabWindows/CVI, MATLAB
Keysight IO Libraries
(version 16.3 or newer)
Includes: VISA Libraries, Keysight Connection
Expert, IO Monitor
Related Products
Model
Description
M9393A
PXIe Performace Vector Signal Analyzer
M9391A
PXIe Vector Signal Analyzer
M9381A
PXIe Vector Signal Generator
M9380A
PXIe CW Source
M9420A
PXIe Vector Transceiver
M9018A
18-slot PXIe Chassis
M9037A
PXIe Embedded Controller
M9036A
PXIe Embedded Controller
Advantage services: Calibration
Keysight Advantage Services is committed to your success throughout
your equipment’s lifetime
N7800A
Calibration & Adjustment Software
10 | Keysight | M9300A PXIe Frequency Reference - Data Sheet
Evolving Since 1939
Our unique combination of hardware, software, services, and people can help you
reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight.
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.keysight.com/find/emt_product_registration
Register your products to get up-to-date product information and
find warranty information.
Keysight Services
www.keysight.com/find/service
Keysight Services can help from acquisition to renewal across your
instrument’s lifecycle. Our comprehensive service offerings—onestop calibration, repair, asset management, technology refresh,
consulting, training and more—helps you improve product quality
and lower costs.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure
your instruments are operating to specification, so you can rely on
accurate measurements.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and
product breadth, combined with channel partner convenience.
www.keysight.com/find/modular
www.keysight.com/find/m9300a
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-9-7-17)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2012-2017
Published in USA, November 18, 2017
5991-0898EN
www.keysight.com
Similar pages