MA1500RU Series 4:1 Input Range, 15W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 15W Output Power • 4:1 Input Voltage Range • Compact DIP Case • 1,600 VDC I/O Isolation • Meets EN 55032 “A” • Single & Dual Outputs • Remote On/Off Control • Wide Temperature Operation • Industry Standard Pin-Out Input Parameter Conditions Input Voltage Range Start Up Time Input Filter Input Reflected Ripple Current Output Parameter Output Voltage Accuracy Line Regulation, VIN = Min to Max Load Regulation, See Note 2 Cross Regulation, Dual Output Ripple & Noise (20 MHz) Transient Recovery Time, See Note 5 Transient Response Deviation Output Power Protection Temperature Coefficient Output Short Circuit Protection General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Remote On/Off (See Page 2) Parameter Supply On Supply Off Standby Input Current Control Common Environmental Parameter Operating Temperature Range MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Min. 24 VDC Input 9.0 48 VDC Input 18.0 Nominal VIN & Constant Resistive Load (Pi) Filter Typ. 24.0 48.0 20 Max. 36.0 72.0 Min. Single Output Dual Output Single Output Dual Output See Note 3 See Note 4 Typ. ±1.0 mA P - P Max. ±0.2 ±0.5 ±0.5 ±1.0 ±5.0 60 250 25% Load Step Change ±3.0 150 ±0.02 Continuous (Autorecovery) Conditions Input/Output, 60 Seconds Case/Input, Output, 60 Seconds 500 VDC 100 kHz/1V Conditions See Note On Page 3 Min. 1,600 1,600 1,000 Typ. Max. Ambient Case Min. -40 % % % mV P - P µSec % % IOUT %/ºC Units M⍀ pF kHz Typ. Max. 12 1.2 Units VDC VDC mA Max. +85 +105 +125 Units ºC ºC ºC 5.0 Referenced to -Input (Pins 2, 3) Conditions Units % VDC 2,000 280 Min. 3.0 0.0 VDC mS 20.0 Conditions Units Typ. -40 Free Air Convection RH, Non-condensing 95 % See Mechanical Diagram (Page 3) Copper With Nickel Coating (UL94V-0) 0.705 Oz (18g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 410 Typ. Max. Units kHours Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. Typ. Max. 50.0 100.0 260 Units Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Input Model Number MA1524S-03RU Voltage (VDC) Nominal Range 24 9.0 - 36.0 Output Current (mA) Full-Load No-Load 640 15 Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 4,000 Over Max Rating Voltage Capacitive Efficiency Fuse Slow-Blow Protection Load (%, Typ) (mA) (VDC) 0.0 3.9 (µF Max) 4,700 88 3,000 MA1524S-051RU 24 9.0 - 36.0 724 15 5.1 3,000 0.0 6.2 3,300 90 3,000 MA1524S-12RU 24 9.0 - 36.0 710 15 12.0 1,250 0.0 15.0 1,250 90 3,000 MA1524S-15RU 24 9.0 - 36.0 710 15 15.0 1,000 0.0 18.0 1,000 90 3,000 MA1524D-05RU 24 9.0 - 36.0 744 15 ±5.0 ±1,500 ±0.0 ±15.0 1,500 86 3,000 MA1524D-12RU 24 9.0 - 36.0 718 15 ±12.0 ±625 ±0.0 ±15.0 625 89 3,000 MA1524D-15RU 24 9.0 - 36.0 710 15 ±15.0 ±500 ±0.0 ±18.0 500 90 3,000 MA1548S-03RU 48 18.0 - 75.0 316 15 3.3 4,000 0.0 3.9 4,700 89 1,500 MA1548S-051RU 48 18.0 - 75.0 366 15 5.1 3,000 0.0 6.2 3,300 89 1,500 MA1548S-12RU 48 18.0 - 75.0 355 15 12.0 1,250 0.0 15.0 1,250 90 1,500 MA1548S-15RU 48 18.0 - 75.0 355 15 15.0 1,000 0.0 18.0 1,000 90 1,500 MA1548D-05RU 48 18.0 - 75.0 372 15 ±5.0 ±1,500 ±0.0 ±15.0 1,500 86 1,500 MA1548D-12RU 48 18.0 - 75.0 359 15 ±12.0 ±625 ±0.0 ±15.0 625 89 1,500 MA1548D-15RU 48 18.0 - 75.0 355 15 ±15.0 ±500 ±0.0 ±18.0 500 90 1,500 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is specified for a load change of 0% to 100%. Load regulation for 3.3V output models is ±1.0% max for a load change of 0% to 100%. 3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 4. Output ripple is measured with a 1.0 µF capacitor connected from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. See the typical connection diagram & notes on page 3. 5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%. 6. Operation at no-load will not damage these units. However, they may not meet all specifications. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Temperature Derating Curve Typical Connection To meet the requirements of EN 61000-4-4 & EN 61000-4-5, the external filter capacitors (C1 & C2) in the diagram above) are required. The recommended value for C1 & C2 is 330 µF/100V. A single 680 µF/100V capacitor may also be used. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. The Remote On/Off circuit is referenced to the minus input of the unit (pins 2 & 3). If the On/Off input (pin 1) is connected to the minus input, the unit is shut off. If pin 1 is left open, the unit operates normally. Page 2 EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFM We Power Your Success - For Less Standard EN 55032 EN 55032 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Criteria/Level Class A Class A B A B B A A www.micropowerdirect.com Efficiency vs Output Load: 24 VIN Models Efficiency vs Output Load: 48 VIN Models Mechanical Dimensions Pin Connections Pin Single 1 Remote On/Off 2 -VIN 3 -VIN 9 No Pin 11 NC 14 +VOUT 16 -VOUT 22 +VIN 23 +VIN NC: No Connection Dual Remote On/Off -VIN -VIN Common -VOUT +VOUT Common +VIN +VIN Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MPD offers a wide range of DC/DC converters in the standard 24 pin DIP package. Models range from 1W to 15W and offer wide input ranges, high isolation & tight regulation. Many are approved to EN 60950. For full information, go to our website or contact the factory. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]