NEC MPLCG0630L2R2 Large-current power inductor mplcg sery Datasheet

03
Vol.
Large-Current Power Inductor
MPLCG Series
[RoHS Compliant]
Inductance
(H)
at 100kHz
Model
DC resistance
RDC(m)max.
Irms ※1
(Ref.)
Rated Current(A)
Isat ※2
(Ref.)
MPLCG0530LR22
0.22±20%
3.7
14.1
10.2
MPLCG0530LR33
0.33±20%
7.3
10.3
8.9
MPLCG0530L1R0
1.0±20%
14.6
7.4
5.6
MPLCG0530L1R5
1.5±20%
21.7
5.9
5.6
MPLCG0530L2R2
2.2±20%
36.4
4.5
5.0
MPLCG0630L1R0
1.0±20%
9.0
11.9
11.3
MPLCG0630L1R5
1.5±20%
15.0
9.9
8.3
MPLCG0630L2R2
2.2±20%
19.0
8.2
7.8
MPLCG0630L3R3
3.3±20%
30.0
6.5
6.3
MPLCG0630L4R7
4.7±20%
41.0
5.5
5.4
※1 T=40K rise at rated current. ※2 Inductance drop 20% at rated current.
Operating temperature range: -20〜+120°C (Include self temperature rise)
5.5 max.
3.0 max.
(1.1)
(1.1)
Part No.
2.5 ± 0.2
Lot No.
2.5 ± 0.2
MPLCG0530 Series
5.0 ± 0.2
Shape and Dimensions
(0.1)
7.5 max.
3.0 max.
(3.2)
(1.4)
(1.4)
3.2 ± 0.2
Lot No.
3.2 ± 0.2
Part No.
6.7 ± 0.2
MPLCG0630 Series
(0.1)
[mm]
Recommended Land Pattern
3.5
MPLCG0630 Series
2.8
MPLCG0530 Series
1.7
2.3
1.7
2.0
3.7
2.0
[mm]
All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
Please request for a specification sheet for detailed product data prior to the purchase.
Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
9631MLGVOL03E1205E0
DC-Superposed Characteristics
Inductance at 20deg.C[uH]
Inductanceat 20deg.C[uH]
R33
R22
0.8
0.6
0.4
0.2
0.0
0
5
10
DC Current[A]
MPLCG0530Series【L1R0,L1R5,L2R2】
3.0
15
20
2R2
1R5
1R0
2.5
2.0
1.5
1.0
0.5
0.0
0
Dimensions of indented square hole plastic tape
5
DC Current[A]
10
3.0
2.0
1.0
0.0
15
4R7
3R3
2R2
1R5
1R0
4.0
0
5
10
DC Current[A]
15
MPLCG0530 Series
(3500pcs./reel)
W
±0.3
12.0
1
MPLCG0630Series
5.0
Inductance at 20deg.C[uH]
MPLCG0530Series
【LR22,LR33】
1.0
F
±0.1
5.5
E1
±0.1
1.75
P1
±0.1
8.0
P2
±0.1
2.0
[mm]
P0
±0.1
4.0
φD0
±0.05
1.55
T
±0.05
0.4
MPLCG0630 Series
(2000pcs./reel)
W
±0.3
16.0
Reel dimensions
[mm]
P1
±0.1
12.0
P2
±0.1
2.0
P0
±0.1
4.0
φD0
±0.05
1.55
T
±0.05
0.4
A
±5.0
φ380
D
B
±10
φ95
C
±1.0
φ13.5
D
±0.8
φ21.0
A0
±0.5
2.0
r
W1
±1.5
14.5
W2
±2.0
18.5
D
±0.8
φ21.0
A0
±0.5
2.0
W1
±1.0
18.0
W2
±1.5
21.6
[mm]
R1.0
A
C
E1
±0.1
1.75
MPLCG0530 Series
W2
B
A0
F
±0.1
7.5
MPLCG0630 Series
W1
2nd Sales Unit
Chiyoda First Bldg., 8-1, Nishi-Kanda 3-chome,Chiyoda-ku, Tokyo 101-8362, Japan
1st Overseas Sales Dept.
Phone: +81-3-3515-9222
Fax: +81-3-3515-9223
2nd Overseas Sales Dept.
Phone: +81-3-3515-9224
Fax: +81-3-3515-9223
NEC TOKIN Korea Co.,Ltd.
518, Korea City AIR-Terminal B/D, 159-6, Samsung-dong, Kangnam-gu, Seoul 135-728, Korea
Phone: +82-2-551-3651 Fax: +82-2-551-3650
NEC TOKIN America Inc.
(Headquarters & Western Area Sales)
2460 North First Street, Suite 220, San Jose, California 95131, U.S.A.
Phone: +1-408-324-1790 Fax: +1-408-324-1497
A
±5.0
φ380
B
±10
φ95
C
±1.0
φ13.5
[mm]
r
R1.0
NEC TOKIN Shanghai Co.,Ltd.
Room 301-302, Metro Plaza, No.555 Loushanguan Road, Changning District, Shanghai, China 200051
Phone: +86-21-6228-0606 Fax: +86-21-6228-6862
NEC TOKIN Singapore Pte Ltd.
150 Changi Road, #04-02 Guthrie Building, Singapore 419973
Phone: +65-6345-3181 Fax: +65-6345-6016
NEC TOKIN Taiwan Co.,Ltd.
Room 411, 4F, No.9, Lane 3, Minsheng W.Road, Taipei 104, Taiwan
Phone: +886-2-2521-3998 Fax: +886-2-2521-3993
NEC TOKIN Europe GmbH
Hellersbergstrasse 14, D-41460 Neuss, Germany
Phone: +49-2131-1866-0 Fax: +49-2131-1866-18
France Branch
Chicago Branch (Northeast Sales Office)
9, Rue Paul Dautier, 78142 Velizy-Villacoublay, France
Phone: +33-1-39-452011 Fax: +33-1-39-451209
Austin Branch (Southeast Sales Office)
©2012 NEC TOKIN Corporation
NEC TOKIN Hong Kong Ltd.
Technical support
NEC TOKIN EMC Division Sales and Marketing Department
1600 Golf Road, Corporate Center, Suite 1228, Rolling Meadows, Illinois 60008, U.S.A.
Phone: +1-847-981-5047 Fax: +1-847-981-5051
11782 Jollyville Road, Suite 208, Austin, Texas 78759, U.S.A.
Phone: +1-512-219-4040 Fax: +1-512-219-4007
Unit Nos. 1513-1517, Level 15, Tower Ⅱ, Grand Central Plaza, 138 Shatin Rural Committee Road,
Shatin, New Territories, Hong Kong
Phone: +852-2730-0028 Fax: +852-2375-2508
phone: +81-3-3515-9260 Fax: +81-3-3515-9278
For inquiry, Please call Sales Promotion Department (Japan)
Phone: +81-3-3515-9220 Fax: +81-3-3515-9221
Precautions
●The names of the products and the specifications in this catalog are subject to change without notice for the sake of improvement. The manufacturer also reserves the right
to discontinue any of these products. At the time of delivery, please ask for specifications sheets to check the contents in order to use the products properly and safely.
●Descriptions in this catalog regarding product characteristics and quality are based solely on discrete components. When using these components, be sure to check the
specifications with the component in question mounted on the products.
●The manufacturer,s warranty will not cover any disadvantage or damage caused by improper use of the products that deviates from the characteristics, specifications, or
conditions for use described in this catalog.
●The products in this catalog are intended for use in ordinary electronic products. If any of these products are to be used in special applications requiring extremely high
reliability, such as in aviation equipment and nuclear power controllers where product defects might pose a safety risk, please consult your NEC TOKIN sales representatives.
●Though the manufacturer has taken all possible precautions to ensure the quality and reliability of its products, improper use of products may result in bodily injury, fire, or
similar accident. If you have any questions regarding the use of the products in question, please consult your NEC TOKIN sales representatives.
●Please be advised that the manufacturer accepts no responsibility for any infraction by users of the manufacturer,s products on third party patents or industrial
copyrights. The manufacturer is responsible only when such infractions are attributable to the structural design of the product and its manufacturing process.
●Export Control
For customers outside Japan
NEC TOKIN products should not be used or sold for use in the development, production, stockpiling or utilization of any conventional weapons or mass-destructive
weapons(nuclear weapons, chemical or biological weapons, or missiles), or any other weapons.
For customers in Japan
For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license specified by the law is required for export.
●This catalog is current as of May 2012.
http://www.nec-tokin.com
9631MLGVOL03E1205E0
Printed in Japan
All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
Please request for a specification sheet for detailed product data prior to the purchase.
Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
9631MLGVOL03E1205E0
Similar pages