Power Systems MBUS-0505 Dc-dc converter unit 1.25 w unregulated dc-dc converter Datasheet

DC-DC Converter UNIT
MBU Series ( 1.25 W UNREGULATED DC-DC CONVERTER )
FEATURES
z
z
z
1000VDC ISOLATION
EFFICIENCY UP TO 82%
INTERNAL SMD TECHNOLOGY
LOW COST
NO HEATSINK REQUIRED
UP TO 1.25W UNREGULATED
OUTPUT POWER
DUAL IN LINE PACKAGE
100% BURNED IN
MTBF > 2,000,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ C
O
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-1.2% max
2
+/-8% max
Short Circuit Protection
z
Momentary
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
z
GENERAL SPECIFICATIONS
Efficiency
Isolation Voltage3
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +85 OC
Switching Frequency
100 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
LINE,
Case Size
FULL
LOAD
,
AND
70%-82%
25
O
C
UNLESS
2,000,000 Hours
1.7g Typ
Non-Conductive Plastic
12.7mm*10.16mm*7.62mm
OTHERWISE NOTED.
1
Line Regulation is for a 1.0% change in input Voltage.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 10 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MBU Series ( 1.25 W UNREGULATED DC-DC CONVERTER )
z SELECTION GUIDE
1.25W OUTPUT
INPUT
OUTPUT
OUTPUT
MODEL NUMBER VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
FULL
NO
LOAD
LOAD
EFF
ISOLATION
(%)
(VDC)
MBUS-0505
5
5
250
335
30
75
1000
MBUS-0509
5
9
140
335
30
75
1000
MBUS-0512
5
12
104
315
30
79
1000
MBUS-0515
5
15
84
310
30
81
1000
MBUS-1205
12
5
250
135
12
77
1000
MBUS-1209
12
9
140
135
12
77
1000
MBUS-1212
12
12
104
130
12
80
1000
MBUS-1215
12
15
84
130
12
80
1000
MBUS-2405
24
5
250
68
10
77
1000
MBUS-2409
24
9
140
68
10
77
1000
MBUS-2412
24
12
104
65
10
80
1000
MBUS-2415
24
15
84
65
10
80
1000
MBUS-4805
48
5
250
34
6
77
1000
MBUS-4809
48
9
140
34
6
77
1000
MBUS-4812
48
12
104
33
6
79
1000
MBUS-4815
48
15
84
33
6
79
1000
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MBU Series ( 1.25 W UNREGULATED DC-DC CONVERTER )
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
TOP VIEW
SIDE VIEW
BOTTOM VIEW
12.7[0.50]
PIN
SINGLE
1
-Vin
4
4
+Vin
5
5
+Vout
7
-Vout
7.62[0.30]
0.25[0.01]
10.16[0.40]
DANUBE
1
7.62[0.30]
7.62[0.30]
7
3.81[0.15]
0.50[0.02]
5.08[0.20]
All dimensions are in mm[inches]
z SIMPLIFIED SCHEMATIC
z TYPICAL APPLICATIONS
INPUT
+Vin
OUTPUT
+Vin
+Vout
+Vout
OSCILLATOR
DRIVER
-Vin
DC-DC
CONVERTER
-Vout
-Vin
www.Power-Systems.de
Page: 3 / 5
LOAD
-Vout
Version: 4-Oct-02
DC-DC Converter UNIT
MBU Series ( 1.25 W UNREGULATED DC-DC CONVERTER )
z TYPICAL PERFORMANCE CUREVES
VOUT VS LOAD(5Vout Models)
VOUT VS LOAD(9Vout Models)
6.4
10.4
6.0
10.0
Vout(V)
Vout(V)
Specifications typical at ta=25 OC , nominal input voltage , rated output current unless otherwise specified.
5.6
9.6
5.2
9.2
4.8
8.8
0
60
120
180
0
250
35
105
140
Output Current(mA)
Output Current(mA)
VOUT VS LOAD(12Vout Models)
VOUT VS LOAD(15Vout Models)
13.8
16.5
13.4
16.0
13.0
Vout(V)
Vout(V)
70
12.6
15.5
15.0
12.2
11.8
14.5
0
26
52
78
104
0
21
Output Current(mA)
42
63
84
Output Current(mA)
EFFICIENCY VS LOAD
DERATING CURVE
EFFICIENCY(%)
125%
80.0
100%
60.0
75%
40.0
SAFE
OPERATING
AREA
50%
20.0
25%
0.0
0
20
40
60
80
100
-25
% OF RATED LOAD(%)
www.Power-Systems.de
0
20
40
60
80
100
120
TA(degree C)
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MBU Series ( 1.25 W UNREGULATED DC-DC CONVERTER )
MBU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output
capacitance may be increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of
less than 0.5 ohm from DC to 250KHz is required.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground
and connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02