ELECTRONICS 2-electrode Spark Gap GXP Series Circuit Protection System Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. 2-electrode Spark Gap - GXP Series The GXP Series of 2-electrode spark gaps are gas discharge tubes, hermetically sealed in a glass/metal envelope. Tubes with a DC breakdown voltage in the range 250 V to 10 kV are available. This is signified by a numeral or numerals following the type letters and is expressed in hundreds of volts, e.g. GXP60 has a 6kV DC breakdown voltage. Typical Applications 1. Single-shot pulse generators 2. Turbine engine ignition circuits 3. Medical lithotripsy 4. High energy switches Electrical And Physical Characteristics All ratings given in this data sheet a reab solute, nonsimultaneous ratings. It is the equipment designer’s responsibility to ensure that they are not exceeded.The spark gap life depends on circuit conditions such as peak discharge current and duration, charge transfer per discharge and the repetition rate. Charge transfer, single discharge (8/20 ms waveshape) 0.5C max Cumulative charge transfer 6000C at 0.81mC per discharge at 1 Hz Operating temperature -55 to +125°C Mechanical shock, half-sine (to B.S. 2011 test Ea) 40g for 4ms Mounting screw mounted Radioactivity tritium (3H), 5.44 MBq (147 mCi) max per device Circuit Protection System Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Page:1 2-electrode Spark Gap - GXP Series Electriacl Characteristics Part No. DC Spark-over Voltage Max.Impulse Discharge Current (8/20μs) MAX Energy Level Minimum Insulation Resistance MaximumC apacitance (V) (KA) (J) (MΩ) pF W GXP05 500 30 60 100 5 60 GXP10 1000 30 60 100 5 60 GXP12 1200 30 60 100 5 60 GXP14 1400 30 60 100 5 60 GXP15 1500 30 60 100 5 60 GXP16 1600 30 60 100 5 60 GXP18 1800 30 60 100 5 60 GXP20 2000 30 60 100 5 60 GXP21 2100 30 60 100 5 60 GXP22 2200 30 60 100 5 60 GXP23 2300 30 60 100 5 60 GXP24 2400 30 60 100 5 60 GXP25 2500 30 60 100 5 60 GXP26 2600 30 60 100 5 60 GXP27 2700 30 60 100 5 60 GXP28 2800 30 60 100 5 60 GXP29 2900 30 60 100 5 60 GXP30 3000 30 60 100 5 60 GXP31 3100 30 60 100 5 60 GXP32 3200 30 60 100 5 60 GXP33 3300 30 60 100 5 60 GXP34 3400 30 60 100 5 60 GXP35 3500 30 60 100 5 60 GXP40 4000 30 60 100 5 60 GXP45 4500 30 60 100 5 60 GXP50 5000 30 60 100 5 60 GXP55 5500 30 60 100 5 60 GXP60 6000 30 60 100 5 60 GXP65 6500 30 60 100 5 60 GXP70 7000 30 60 100 5 60 GXP75 7500 30 60 100 5 60 GXP80 8000 30 60 100 5 60 GXP85 8500 30 60 100 5 60 GXP90 9000 30 60 100 5 60 GXP95 9500 30 60 100 5 60 GXP100 10000 30 60 100 5 60 GXP105 10500 30 60 100 5 60 GXP110 11000 30 60 100 5 60 GXP115 11500 30 60 100 5 60 GXP120 12000 30 60 100 5 60 Circuit Protection System Maximum power Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Page:2 2-electrode Spark Gap - GXP Series OUTLINE (All dimensions in millimetres) HOLE THREADED M3 x 5.0 MIN DEEP CONTACT CAP Φ9.5 ± 0.5 Φ29.0 MAX Φ29.0 MAX 42.0 MAX 42.0 MAX 64.0 MAX Warehouse Storage Conditions of Products · Storage Conditions: 1. Storage Temperature: -10°C~+40°C 2. Relative Humidity:≤75%RH 3. Keep away from corrosive atmosphere and sunlight. · Period of Storage: 1 year Circuit Protection System Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Page:3 RuiLongYuan Electronics Co., Ltd. · Reproducing and modifying information of the document is prohibited without permission from Ruilongyuan International Inc. · Ruilongyuan International Inc. reserves the rights to make changes of the content herein the document anytime without notification. Please refer to our website for the latest document. · Ruilongyuan International Inc. disclaims any and all liability arising out of the application or use of any product including damages incidentally and consequentially occurred. · Ruilongyuan International Inc. does not assume any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. · Applications shown on the herein document are examples of standard use and operation. Customers are responsible in comprehending the suitable use in particular applications.Ruilongyuan International Inc. makes no representation or warranty that such applications will be suitable for the specifed use without further testing or modifcation. · The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation equipment,aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at their own risk and agree to fullyindemnify Ruilongyuan International Inc. for any damages resulting from such improper use or sale. Tel: +86-755-8290 8296 Circuit Protection System Fax: +86-755-8290 8002 E-mail: [email protected] Specifications are subject to change without notice. Please refer to http://www.ruilon.com for current information. Page:4