Arch AQFV480F-12S Ac-dc switching power supply Datasheet

VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
KEY FEATURES
Standard
A Type
 Enclosed Switching Power Supply
 Universal Input: 90-264 VAC
 Active P.F.C. Function, PF>0.95
 Cooling by Built-in DC FAN
 Protections: Over Load / Over Voltage /
Over Temperature / Short Circuit
.All by Auto-recovery
 Built-in Remote ON/OFF Control
 Built-in Remote Sense Function
 Built-in DC OK Signal
 Stand by 5V @ 0.6A
 High Efficiency up to 92%
 Ultra Compact Size: 7.98 x 4.2 x 1.78 Inches
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
AQFV480F-12S
Max Output Wattage (W)
Voltage
480W
Input
Output
Isolation
AQFV480F-36S
AQFV480F-48S
90-264 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Current (Full load)
< 5.5 A max. (115 VAC) / < 3.0 A max. (230 VAC)
Inrush Current (<2ms)
< 50 A max. (115 VAC) / < 70 A max. (230 VAC)
Leakage Current
< 0.5 mA max.(240VAC 63Hz)
Power Factor
PF>0.95 (115 VAC) / PF>0.90 (230 VAC) at Full Load
Voltage (VDC.)
12V
24V
36V
48V
Trim
10.8 ~ 13.2V
21.6 ~ 26.4V
32.4 ~ 39.6V
43.2 ~ 50.4V
Voltage Accuracy
±2%
20
13.33
10
Current (18CFM FAN) (A) max
40
Line Regulation (LL-HL) (typ.)
±0.5%
Load Regulation (5-100%) (typ.)
±1%
Minimum Load
5%
Maximum Capacitive Load
180000 uF
75000 uF
50000 uF
25000 uF
Ripple & Noise (max.)
100mVp-p
200mVp-p
200mVp-p
300mVp-p
Vin:115(V.AC)
85%
87%
89%
88%
Vin:230(V.AC)
88%
90%
92%
91%
Efficiency (%.)
Protection
AQFV480F-24S
Hold-up Time
10 ms min.
Over Power Protection
Auto recovery
Over Voltage Protection
Auto recovery
Over Temperature
Auto recovery
Short Circuit Protection
Auto-recovery
Input-Output (V.AC)
3000VAC or 4242VDC
Input-FG
(V.AC)
1500V
Output-FG
.(V.AC)
500V
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Function
Environment
Physical
Safety
EMC
AQFV480F-12S
AQFV480F-24S
AQFV480F-36S
AQFV480F-48S
5V Stand by
5VSB: [email protected] ; Tolerance 10% , Ripple & Noise: 100m Vp-p (max.)
DC OK Signal
Turn ON: 4~6V ; Turn OFF: 0~1V
Remote Control
+RC / -RC: Power ON=open ; Power OFF=short
FAN Control
12VDC / 0.5A max.
Operating Temperature
-20°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>100,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Dimension (L x W x H)
7.98 x 4.2 x 1.78 Inches
(202.8 x 106.5 x 45.0 mm ) Tolerance 0.5 mm
Weight
1050 g
Agency Approvals
UL60950-1, CE(Surge:4KV)
EMI (Conducted & Radiated Emission)
EN 55022 class B
EMS (Noise Immunity)
EN 55024
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage,
please disconnect all Y-Capacitors within Arch power supply.
BLOCK DIAGRAM
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
MECHANICAL DIMENSION
Standard
AC Input Terminal Pin
ASSEMBLY INSTRUCTIONS
*U Case T=2.0mm
Customer is advised to screw into the threads no more than 2.0mm
PIN#
Single
1
AC IN (N)
2
AC IN (L)
3
DC Output Terminal Pin
PIN#
Single
4~6
+DC OUT
7~9
-DC OUT
Connector Pin (CN4)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
C1
+S
C2
-S
C3
+RC
C4
-RC
C5
DC-OK
C6
GND
C7
+5V SB
C8
-5V SB
-3-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
MECHANICAL DIMENSION
A Type
AC Input Terminal Pin
ASSEMBLY INSTRUCTIONS
*U Case T=2.0mm
Customer is advised to screw into the threads no more than 2.0mm
PIN#
Single
1
AC IN (N)
2
AC IN (L)
3
DC Output Terminal Pin
PIN#
Single
4~9
+DC OUT
10~15
-DC OUT
Connector Pin (CN4)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
C1
+S
C2
-S
C3
+RC
C4
-RC
C5
DC-OK
C6
GND
C7
+5V SB
C8
-5V SB
-4-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
FUNCTION DESCRIPITON of CN4 :
Pin No.
Function
C1
+S
C2
-S
C3
+RC
C4
-RC
C5
DC-OK
Description
Positive sensing. The +S signal should be connected to the positive terminal of the load.
The +S and -S leads should be twisted in pair to minimize noise pick-up effect.
The maximum line drop compensation is 0.5V. (max.)
Negative sensing. The -S signal should be connected to the negative terminal of the load.
The -S and +S leads should be twisted in pair to minimize noise pick-up effect.
The maximum line drop compensation is 0.5V. (max.)
Turns the output on and off by electrical or dry contact between pin C4 (-RC), Short: Power OFF, Open: Power ON.
Remote control ground.
DC-OK Signal is a DC output, referenced to pinC6(DC-OK GND).
C6
GND
C7
+5V SB
Stand by voltage output ground 4.5~5.5V, referenced to pin C8(-5V SB). The maximum load current is 0.6A.
This pin connects to the negative terminal(-V). Return for DC-OK signal output.
C8
-5V SB
Stand by voltage output ground.
FUNCTION MANUAL :
1. Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V. (max.)
2. DC-OK Signal
Between DC-OK(pinC5)
and GND(pinC6)
Output
Status
4~6V
0~1V
ON
OFF
3. Remote Control
It can be turned ON/OFF by using the "Remote Control" function.
Between RC+(pinC3) and
RC-(pinC4)
Output
Status
SW ON (Short)
SW OFF (Open)
OFF
ON
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-5-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
EFFICIENCY VERSUS LOAD (with 18CFM FAN)
AQFV480F-12S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
Efficiency
90
115
180
230
264
Load (%)
0
10
20
30
40
50
83.90
86.17
88.12
88.97
89.15
115V (%)
0
80.55
87.57
89.04
88.85
88.71
230V (%)
0
79.24
87.06
89.66
90.39
90.81
Load (%)
60
70
80
90
100
115V (%)
88.59
88.16
87.53
86.93
86.17
230V (%)
90.62
90.38
89.98
89.55
88.97
95.00%
100.00%
90.00%
95.00%
85.00%
90.00%
85.00%
EFF%
80.00%
EFF%
VS
75.00%
70.00%
80.00%
75.00%
70.00%
65.00%
65.00%
60.00%
60.00%
55.00%
55.00%
90V
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
80%
90%
100%
LOAD
AQFV480F-24S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
86.51
88.60
90.58
91.32
91.56
115V (%)
0
83.91
89.22
90.81
90.61
90.53
230V (%)
0
81.02
88.37
91.11
91.72
92.35
Load (%)
60
70
80
90
100
115V (%)
90.36
89.66
89.56
89.10
88.60
230V (%)
92.48
92.36
92.23
91.74
91.32
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
Efficiency
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
VS
55.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
-6-
VER : B_4
update : 2015.11.17
AC-DC Switching Power Supply
AQFV480F SERIES
(CV Mode)
480 Watts
EFFICIENCY VERSUS LOAD (with 18CFM FAN)
AQFV480F-36S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
Efficiency
90
115
180
230
264
Load (%)
0
10
20
30
40
50
87.75
89.98
92.19
92.96
93.21
115V (%)
0
81.77
87.84
90.61
90.36
90.80
230V (%)
0
78.91
87.02
90.20
91.32
92.36
Load (%)
60
70
80
90
100
115V (%)
91.05
90.75
90.49
90.30
89.98
230V (%)
92.80
93.04
92.80
93.03
92.96
100.00%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
55.00%
90V
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
80%
90%
100%
LOAD
AQFV480F-48S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
87.25
89.33
91.21
92.26
92.48
115V (%)
0
81.82
87.48
89.68
89.51
90.09
230V (%)
0
79.23
86.44
90.02
90.77
91.90
Load (%)
60
70
80
90
100
115V (%)
89.92
90.07
89.75
89.78
89.33
230V (%)
91.94
92.33
92.18
92.37
92.26
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
Efficiency
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
VS
55.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
-7-