Panasonic CN-24CL-C2 Cylindrical inductive proximity sensor Datasheet

Cylindrical Inductive Proximity Sensor
GX-M SERIES
Conforming to
EMC Directive
Listing
(2 m cable length type only)
Features
• Wide product range
Types: D
C 3-wire shielded type
DC 3-wire non-shielded type
DC 2-wire standard type
DC 2-wire long range type
Size: M8, M12, M18, M30
Connector: 2
m cable length type
M12 plug-in connector type
M12 pigtaild type (DC 2-wire
M8 type only)
• Strong resistance IP68 (GX-M8□ : IP67)
ORDER GUIDE
DC 3-wire type (2 m cable length type)
M8
M12
M18
Sensing range (Note 1,2)
Max. operation distance: 2 mm 0.08 in
(Stable sensing range 0 to 1.6 mm 0.06 in)
Max. operation distance: 5 mm 0.20 in
(Stable sensing range 0 to 4 mm 0.16 in)
M12
Max. operation distance: 10 mm 0.39 in
(Stable sensing range 0 to 8 mm 0.32 in)
M18
Ex.) GX-M12□
Max. operation distance: 7 mm 0.28 in
(Stable sensing range 0 to 5.6 mm 0.22 in)
Max. operation distance: 12 mm 0.47 in
(Stable sensing range 0 to 9.6 mm 0.38 in)
M30
Non-shielded
Appearance
Max. operation distance: 1.5 mm 0.06 in
(Stable sensing range 0 to 1.2 mm 0.05 in)
M30
Shielded
Type
Ex.) GX-MK12□
Max. operation distance: 22 mm 0.87 in
(Stable sensing range 0 to 17.6 mm 0.69 in)
Model No.
NPN output
PNP output
Output
operation
GX-M8A
GX-M8A-P
Normally open
GX-M8B
GX-M8B-P
Normally closed
GX-M12A
GX-M12A-P
Normally open
GX-M12B
GX-M12B-P
Normally closed
GX-M18A
GX-M18A-P
Normally open
GX-M18B
GX-M18B-P
Normally closed
GX-M30A
GX-M30A-P
Normally open
GX-M30B
GX-M30B-P
Normally closed
GX-MK12A
GX-MK12A-P
Normally open
GX-MK12B
GX-MK12B-P
Normally closed
GX-MK18A
GX-MK18A-P
Normally open
GX-MK18B
GX-MK18B-P
Normally closed
GX-MK30A
GX-MK30A-P
Normally open
GX-MK30B
GX-MK30B-P
Normally closed
Notes: 1) It is the value in state where the circumference of a detection side has a metal object.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
7
Cylindrical Inductive Proximity Sensor
GX-M SERIES
ORDER GUIDE
DC 2-wire type (2 m cable length type)
M8
Max. operation distance: 1.5 mm 0.06 in
(Stable sensing range 0 to 1.2 mm 0.05 in)
M12
Max. operation distance: 2 mm 0.08 in
(Stable sensing range 0 to 1.6 mm 0.06 in)
Max. operation distance: 5 mm 0.20 in
(Stable sensing range 0 to 4 mm 0.16 in)
Max. operation distance: 10 mm 0.39 in
(Stable sensing range 0 to 8 mm 0.32 in)
Max. operation distance: 2.5 mm 0.10 in
(Stable sensing range 0 to 2 mm 0.08 in)
M12
Ex.) GX-M12□-U
Max. operation distance: 4 mm 0.16 in
(Stable sensing range 0 to 3.2 mm 0.13 in)
M18
Max. operation distance: 8 mm 0.32 in
(Stable sensing range 0 to 6.4 mm 0.25 in)
Max. operation distance: 15 mm 0.59 in
(Stable sensing range 0 to 12 mm 0.47 in)
M30
Long range
Model No.
M18
Sensing range (Note 1,2)
M30
Appearance
M8
Standard
Type
Output operation
GX-M8A-U
Normally open
GX-M8B-U
Normally closed
GX-M12A-U
Normally open
GX-M12B-U
Normally closed
GX-M18A-U
Normally open
GX-M18B-U
Normally closed
GX-M30A-U
Normally open
GX-M30B-U
Normally closed
GX-ML8A-U
Normally open
GX-ML8B-U
Normally closed
GX-ML12A-U
Normally open
GX-ML12B-U
Normally closed
GX-ML18A-U
Normally open
GX-ML18B-U
Normally closed
GX-ML30A-U
Normally open
GX-ML30B-U
Normally closed
Notes: 1) It is the value in state where the circumference of a detection side has a metal object.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
M12 plug-in connector type (except for GX-M8□-U and GX-ML8□-U)
M12 plug-in connector type is also available.
When ordering this type, “-Z” for the M12 plug-in connector type to the model No.
(e.g.) M12 plug-in connector type of GX-M8A-P is “GX-M8A-P-Z”.
M12 pigtailed type (for GX-M8□-U and GX-ML8□-U only)
M12 pigtailed type is also available.
When ordering this type, “-J” for the M12 pigtailed type to the model No.
(e.g.) M12 pigtailed type of GX-M8A-U is “GX-M8A-U-J”.
Mating cable (2 cables are required for the thru-beam type.)
For M12 plug-in
connector type
Type
Straight
Elbow
Model No.
Description
CN-24C-C2
Length: 2 m 6.56 ft
CN-24C-C5
Length: 5 m 16.40 ft
Clamping ring :
ø14mm 0.55 in
CN-24CL-C2
Length: 2 m 6.56 ft
CN-24CL-C5
Length: 5 m 16.40 ft
Cable outer :
ø5.3mm 0.21 in
Mating cable
• Straight type
• Elbow type
8
Cylindrical Inductive Proximity Sensor
GX-M SERIES
SPECIFICATIONS
DC 3-wire type
Shielded type
Model No.
Type
Item
Normally open
GX-M8A□
Normally closed
GX-M8B□
Standard sensing object
Non-shielded type
GX-18A□
GX-M30A□
GX-18B□
GX-M30B□
GX-MK12B□
GX-MK18B□
GX-MK30B□
10 mm 0.39 in ±10 %
7 mm 0.28 in ±10 %
12 mm 0.47 in ±10 %
22 mm 0.87 in ±10 %
0 to 1.2 mm
0 to 0.05 in
0 to 1.6 mm
0 to 0.06 in
0 to 4 mm
0 to 0.16 in
0 to 8 mm
0 to 0.32 in
0 to 5.6 mm
0 to 0.22 in
0 to 9.6 mm
0 to 0.38 in
0 to 17.6 mm
0 to 0.69 in
Iron sheet 8 × 8 × t 1 mm
0.32 × 0.32 × t 0.04 in
Iron sheet 12 × 12 × t 1 mm
0.47 × 0.47 × t 0.04 in
Iron sheet 18 × 18 × t 1mm
0.71 × 0.71 × t 0.04 in
Iron sheet 30 × 30 × t 1 mm
1.18 × 1.18 × t 0.04 in
Iron sheet 24 × 24 × t 1 mm
0.94 × 0.94 × t 0.04 in
Iron sheet 24 × 24 × t 1 mm
0.94 ×0.94 × t 0.04 in
Iron sheet 45 × 45 × t 1 mm
1.77 × 1.77 × t 0.04 in
15 % or less of operation distance (with standard sensing object)
Along sensing axis: 5 % or less of operation distance
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption (Note 4)
10 mA or less
<NPN output type>
NPN open-collector transistor
• Maximum sink current 200 mA
• Applied voltage: 24 V DC or less (between output and 0 V)
• Residual voltage 2 V or less
Incorporated
Short-circuit protection
5 kHz
5 kHz
Operation indicator
Environmental resistance
2 kHz
1 kHz
1 kHz
0.5 kHz
3 (industrial enviroment)
IP67 (IEC)
Ambient temperature
IP69K (DIN), IP68 (IEC) (2 m cable length type only) , IP67 (IEC) (M12 plug-in connector type only)
–25 to +70 °C –13 to +158 °F, Storage: –40 to +85 °C –40 to +185 °F
Ambient humidity
50 % RH or less (at +70 °C +158 °F)
EMC
EN 60947-5-2
Voltage withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each
294 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Shock resistance
Sensing range variation
(Note 2)
Within ±10 % fluctuation of sensing range at +23 °C +73 °F and rated voltage in the range of
allowable temperature and supply voltage
Material
Enclosure: Brass (Nickel plated), Sensing part: PPS
0.44 mm2 (0.15 mm2 for GX-M8□) 3-core cabtyre cable, 2 m 6.56 ft long
Cable (except for M12 plug-in connector type)
Extension up to total 10 m 32.80 ft is possible with 0.34 mm2, or more, cable.
Cable extension
Accessories
2.5 kHz
Yellow LED (lights up when the output is ON)
Pollution degree
Net weight
(Note 5)
<PNP output type>
PNP open-collector transistor
• Maximum source current 200 mA
• Applied voltage: 24 V DC or less (between output and + V)
• Residual voltage 2 V or less
DC-12 or DC-13
Utilization category
Protection
GX-MK30A□
5 mm 0.20 in ±10 %
Repeatability (Note 2)
Max. response frequency
GX-MK18A□
GX-M12B□
Hysteresis (Note 2)
Output
GX-MK12A□
2 mm 0.08 in ±10 %
Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 %
Stable sensing range (Note 2,3)
GX-M12A□
2 m cable length type
40 g approx.
70 g approx.
90 g approx.
150 g approx.
75 g approx.
100 g approx.
180 g approx.
M12 plug-in connector type
15 g approx.
20 g approx.
45 g approx.
110 g approx.
25 g approx.
55 g approx.
140 g approx.
Nut: 2 pcs.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) It is the value in state where the circumference of a detection side has a metal object.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
4) It is the leakage current when the output is in the OFF state.
5) The weight includes the weight of two nuts.
9
Cylindrical Inductive Proximity Sensor
GX-M SERIES
SPECIFICATIONS
DC 2-wire type
Standard type
Model No.
Type
Item
Long range type
Normally open
GX-M8A-U(-J) GX-M12A-U(-Z) GX-M18A-U(-Z) GX-M30A-U(-Z) GX-ML8A-U(-J) GX-ML12A-U(-Z) GX-ML18A-U(-Z) GX-ML30A-U(-Z)
Normally closed
GX-M8B-U(-J) GX-M12B-U(-Z) GX-M18B-U(-Z) GX-M30B-U(-Z) GX-ML8B-U(-J) GX-ML12B-U(-Z) GX-ML18B-U(-Z) GX-ML30B-U(-Z)
Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % 2 mm 0.08 in ±10 %
Stable sensing range (Note 2,3)
Standard sensing object
5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 2.5 mm 0.10 in ±10 % 4 mm 0.16 in ±10 %
0 to 1.2 mm
0 to 0.05 in
0 to 1.6 mm
0 to 0.06 in
0 to 4 mm
0 to 0.09 in
0 to 8 mm
0 to 0.22 in
0 to 2 mm
0 to 0.08 in
0 to 3.2 mm
0 to 0.13 in
0 to 6.4 mm
0 to 0.25 in
0 to 12 mm
0 to 0.47 in
Iron sheet 8 × 8 × t 1 mm
0.32 × 0.32 × t 0.04 in
Iron sheet 12 × 12 × t 1 mm
0.47 × 0.47 × t 0.04 in
Iron sheet 18 × 18 × t 1mm
0.71 × 0.71 × t 0.04 in
Iron sheet 30 × 30 × t 1 mm
1.18 × 1.18 × t 0.04 in
Iron sheet 8 × 8 × t 1 mm
0.32 × 0.32 × t 0.04 in
Iron sheet 12 × 12 × t 1 mm
0.47 × 0.47 × t 0.04 in
Iron sheet 18 × 18 × t 1 mm
0.71 × 0.71 × t 0.04 in
Iron sheet 30 × 30 × t 1 mm
1.18 × 1.18 × t 0.04 in
1.5 kHz
0.8 kHz
Hysteresis (Note 2)
15 % or less of operation distance (with standard sensing object)
Repeatability (Note 2)
Along sensing axis: 5 % or less of operation distance
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption (Note 4)
0.5 mA or less
Non-contact DC 2-wire type
• Load current: 1.5 to 100 mA
• Residual voltage: 4.2 V or less (Note 5)
Output
DC-12 or DC-13
Utilization category
Incorporated
Short-circuit protection
Max. response frequency
1 kHz
1 kHz
1.2 kHz
Operation indicator
1.3 kHz
Environmental resistance
Protection
1.3 kHz
3 (Industrial environment)
IP67 (IEC)
IP69K (DIN), IP68 (IEC) (2 m cable length type only) , IP67 (IEC) (M12 plug-in connector type only)
Ambient temperature
–25 to +70 °C –13 to +158 °F, Storage: –40 to +85 °C –40 to +185 °F
Ambient humidity
50 % RH or less (at +70 °C +158 °F)
EMC
EN 60947-5-2
Voltage withstandability
500 V AC for one min. between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each
294 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Shock resistance
Sensing range variation
(Note 2)
Within ±10 % fluctuation of sensing range at +23 °C +73 °F and rated voltage in the range of
allowable temperature and supply voltage
Material
Enclosure: Brass (Nickel plated), Sensing part: PPS
0.44 mm [0.15 mm2 for GX-M(L)8□-U] 2-core cabtyre cable, 2 m 6.56 ft long
Cable (except for M12 plug-in connector type)
2
Cable extension
Accessories
1.1 kHz
Yellow LED (lights up when the output is ON)
Pollution degree
Net weight
(Note 6)
8 mm 0.32 in ±10 % 15 mm 0.59 in ±10 %
Extension up to total 10 m 32.80 ft is possible with 0.34 mm2, or more, cable.
2 m cable length type
40 g approx.
70 g approx.
90 g approx.
150 g approx.
40 g approx.
70 g approx.
90 g approx.
150 g approx.
M12 pigtailed(-J type) /
M12 plug-in connector type
20 g approx.
20 g approx.
45 g approx.
110 g approx.
20 g approx.
20 g approx.
45 g approx.
110 g approx.
Nut: 2 pcs.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) It is the value in state where the circumference of a detection side has a metal object.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
4) It is the leakage current when the output is in the OFF state.
5) When the cable is extended, the residual voltage becomes larger.
6) The weight includes the weight of two nuts.
10
Cylindrical Inductive Proximity Sensor
GX-M SERIES
WIRING DIAGRAMS
DC 3-wire type
Wiring diagram
NPN output type
PNP output type
(Brown) +V
(Brown) +V
Load
+
(Black) Output
–
(Black) Output
12 to 24V DC ±10 %
–
Load
(Blue) 0 V
(Blue) 0 V
Connector pin position
M12 connector
4
3
1
2
• Normally Open
1 : +V
2 : Not connected
3:0V
4 : Output
• Normally Closed
1 : +V
2 : Output
3:0V
4 : Not connected
DC 2-wire type
Wiring diagram
(Brown) +V
Load
+
–
(Blue) 0 V
12 to 24V DC ±10 %
Load
Connector pin position
M12 connector
4
3
1
2
• Normally Open
• Normally Closed
1 : +V
(except for GX-M8□-U-J and GX-ML8□-U-J)
1 : Not connected
2 : Not connected
3 : +V
4:0V
• Normally Open
(GX-M8□-U-J and GX-ML8□-U-J only)
1 : +V
2 : Not connected
3 : Not connected
4:0V
11
+
2:0V
3 : Not connected
4 : Not connected
12 to 24V DC ±10 %
Cylindrical Inductive Proximity Sensor
GX-M SERIES
PRECAUTIONS FOR PROPER USE
Embedding of the sensor in metal
• Never use this product as a sensing device for
personnel protection.
• In case of using sensing devices for personnel
protection, use products which meet laws and
standards, such as OSHA, ANSI or IEC etc.,
for personnel protection applicable in each
region or country.
•S
ensing range may decrease if the
Sensor
B
C
size (mm in) (mm in)
sensor is completely embedded
in metal. Especially for the nonshielded type, keep the minimum
distance specified in the right table.
%
Mounting
• The tightening torque should be under the value given
below.
&
M12
12
0.47
12
0.47
M18
18
0.71
18
0.71
M30
30
1.18
30
1.18
Note: With the non-shielded type, the sensing
range may vary depending on the
position of the nuts.
0HWDO
Mutual interference
• When two or more sensors are installed in parallel or face
to face, keep the minimum separation distance specified
below to avoid mutual interference.
Face to face mounting
'
Tightening torque
Model No.
GX-M□
GX-M(L)8□-U-J
Sensor size
Sensor
Connector
(Note)
M8
5 N·m
2 N·m
M12
6 N·m
2 N·m
M18
15 N·m
2 N·m
M30
40 N·m
2 N·m
M8
5 N·m
1.5 N·m
Note: Connector is equipped with -Z type or -J type.
Distance from surrounding metal
• As metal around the sensor may affect the sensing
performance, pay attention to the following points.
•T
he surrounding metal will affect the sensing performance.
%DFNJURXQGPHWDO
Keep the minimum distance specified in the table below.
$
A (mm in)
M8
M12
M18
M30
3
0.12
4
0.16
10
0.39
20
0.79
-
21
0.83
36
1.42
66
2.60
DC 2-wire standard type
4.5
0.18
6
0.23
15
0.59
30
1.18
DC 2-wire long range type
8
0.32
12
0.47
25
0.98
45
1.77
DC 3-wire shielded type
DC 3-wire non-shielded type
(
Type
DC 3-wire
shielded type
DC 3-wire
non-shielded type
D (mm in)
M8
M12 M18 M30
E (mm in)
M8
M12 M18 M30
18
24
60 120
3
4
10
20
0.71 0.94 2.36 4.72 0.12 0.16 0.39 0.77
-
84 144 264
3.30 5.67 10.39
-
48
72 120
1.89 2.83 4.72
DC 2-wire
standard type
18
24
60 120
3
4
10
20
0.71 0.94 2.36 4.72 0.12 0.16 0.39 0.77
DC 2-wire long
range type
30
50 100 180
5
8
16
30
1.18 1.97 3.93 7.09 0.20 0.32 0.63 1.18
Wiring
Influence of surrounding metal
Type
Parallel mounting
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
• Ensure that an isolation transformer is utilized for the DC power
supply. If an autotransformer is utilized, the main body or power
supply may be damaged.
• If the used power supply generates a surge, connect a surge
absorber to the power supply to absorb the surge.
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
• Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
• Damage or burnout may result in case of short circuit of load or
miswiring.
• Make a cable length as short as possible to lessen noise pickup.
Others
• Our products have been developed / produced for industrial use
only.
• Avoid using a product where there is excessive vapor, dust or
corrosive gas, or in a place where it could be exposed directly to
water or chemicals.
• Take care that the sensor does not come in direct contact with
water, oil, grease or organic solvents, such as, thinner, etc.
• Do not use in an environment containing infammable or explosive gases.
• Never disassemble or modify the product.
12
Cylindrical Inductive Proximity Sensor
GX-M SERIES
DIMENSIONS (Unit: mm in)
DC 3-wire type
LED
Sensors
2 m cable length type (mm in)
Shielded type
b
a
LED
a
a
b
M8
GX-M8□
33 1.30
25 0.98
45 1.77
24 0.94
GX-M12□
35 1.38
25 0.98
50 1.97
30 1.18
M18
GX-M18□
39 1.54
28 1.10
50 1.97
28 1.10
M30
GX-M30□
43 1.69
32 1.26
55 2.17
32 1.26
2 m cable length type (mm in)
Non-shielded type
c
M12 plug-in connector type (mm in)
b
M12
Sensors
b
a
a
b
M12
GX-MK12□
55 2.17
42 1.65
M18
GX-MK18□
60 2.36
M30
GX-MK30□
63 2.48
M12 plug-in connector type (mm in)
c
a
b
66 2.60
42 1.65
44 1.73
8 0.32
72 2.83
44 1.73
8 0.32
41 1.61
13 0.51
74 2.91
41 1.61
13 0.51
DC 2-wire type
LED
Sensors
2 m cable length type (mm in)
Standard type, Long range type
b
a
13
M8
a
c
5 0.20
b
GX-M(L)8□-U (-J)
33 1.30
25 0.98
M12 plug-in connector type (mm in)
(M8 size: M12 pigtailed type)
a
–
b
24 0.94
M12
GX-M(L)12□-U (-Z)
35 1.38
25 0.98
50 1.97
30 1.18
M18
GX-M(L)18□-U (-Z)
39 1.54
28 1.10
50 1.97
28 1.10
M30
GX-M(L)30□-U (-Z)
43 1.69
32 1.26
55 2.17
32 1.26
5 0.20
Disclaimer
The applications described in the catalog are all intended for examples only.
The purchase of our products described in the catalog shall not be regarded as granting of a license to use our products in the described
applications.
We do NOT warrant that we have obtained some intellectual properties, such as patent rights, with respect to such applications, or that the
described applications may not infringe any intellectual property rights, such as patent rights, of a third party.
Please contact ..........
Panasonic Electric Works SUNX Co., Ltd.
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
■Telephone: +81-568-33-7211 ■Facsimile: +81-568-33-2631
Global Sales & Marketing Division
■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591
panasonic-electric-works.net/sunx
All Rights Reserved ©Panasonic Electric Works SUNX Co., Ltd. 2011
No. CE-CYGX-10 November, 2011
Specifications are subject to change without notice.
Printed in Japan
Similar pages