AC-DC 350 Watts xppower.com JPS350 Series • 300 W with Convection Cooling • High Efficiency - up to 90% • Remote On/Off & Remote Sense • Meets 1U, Low Profile Requirements • Zero Voltage Switching Technology • AC OK & DC OK Signals • Current Sharing Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current Input Protection General • • • • • • • 85-264 VAC (170-370 VDC) 47-63 Hz 4 A/2 A max at 115 VAC/230 VAC 30 A at 115 VAC, 60 A at 230 VAC 0.99 typical 2.0 mA max 264 VAC/60 Hz Internal 6.3 A, 250 V fuse Output Voltage Output Voltage Trim Initial Set Accuracy • See table • ±10% single output models only • At 60% rated load ±1% output V1 & V2, ±5% on output V3 & V4 Minimum Load • No minimum load required on single output models. For multi-output models see note 5 Start Up Delay • 2 s typical Start Up Rise Time • 100 ms typical Hold Up Time • 20 ms min at low line Line Regulation • ±0.5% at rated load across input voltage range Load Regulation • ±1% for single output models & V1 & V2 of multi-output models ±5% for V3 & V4 Tolerance • ±1% Transient Response • 4% max deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • ±1% max pk-pk, 20 MHz BW Overvoltage Protection • 115-140%, recycle input to reset Overtemperature • Shuts down at +110 °C, auto recovery Protection Overload Protection • 120-150%, auto recovery Short Circuit Protection • Trip and restart (Hiccup mode) Temperature • ±0.05%/°C Coefficient Remote Sense • Compensates for up to 0.5 V drop Current Share Fan Output Switching Frequency Power Density Signals MTBF Output Remote On/Off Efficiency Isolation • On = Logic Low or Open Off = Logic High • Single wire current sharing (4 supplies can be paralleled) • See mechanical detail notes • Up to 90% • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 120 kHz typical for PFC & PWM • 4.96 W/In3 • AC OK, DC OK and Remote On/Off (see control and supervisory signals) • 100 kHrs per MIL-HDBK-217F Environmental Operating Temperature • 0 °C to +70 °C, (see derating curve) Full power to +50 °C Cooling • 350 W with 18 CFM airflow 300 W convection cooling Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -20 °C to +85 °C Operating Altitude • 3000 m Vibration • 2 g, 10-55 Hz, 3 mins/cycle for 30 mins each axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Safety Approvals • EN55022, level B conducted FCC 20780, level B conducted • EN61000-3-2 • EN61000-3-3 • EN61000-4-2, level 3 Perf Criteria A • EN61000-4-3, 10 V/m Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, level 3 Perf Criteria A • EN60950-1:2001, UL60950-1, CSA C22.2 No. 60950-1, CE Mark LVD Output Power 315 W Output Current Convection-cooled 18 CFM 54.0 A 63.0 A 25.0 A 30.0 A 20.0 A 24.0 A 13.0 A 15.0 A 6.5 A 7.3 A Output Voltage 5V 12 V 15 V 24 V 48 V 350 W Ripple & Noise Pk-Pk(2) 50 mV 120 mV 120 mV 200 mV 200 mV Model Number(1) JPS350PS05C†^ JPS350PS12C†^ JPS350PS15C†^ JPS350PS24C†^ JPS350PS48C†^ Notes 1. For non-current share version delete suffix ‘C’ from model number. 2. Ripple and noise measured over 15 MHz bandwidth with a 47 µF electrolytic capacitor and 0.47 µF ceramic capacitor. † Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Mechanical Details All dimensions are in inches (mm) Tolerance: ±0.03 (0.8) max. Weight: 2.12 lbs (960 g) approx. All models (except JPS350PS05) 9.00 (228.6) A L A B B Pin N 1 E +5 V +V 2 +5 V +V N/C 3 0V +V +Remote sense 4 0V 0V DC OK 5 0V 0V -Remote sense 6 0V 0V 7 +5 V Current Share(1) 7.50 (190.5) 8 +5 V Remote On/Off 8.00 (203.2) 9 AC OK 10 0V 4.50 (114.3) 5.00 (127.0) TRANSFORMER 6 TB2 10 2 1 0.25 (6.4) B B 0.75 (19.1) 0.87 (22.0) + TB3 TB4 A 6.50 (165.1) 0.50 (12.7) A A B B 1.60 (40.6) JPS350PS05 9.00 (228.6) B B A 12 L TB4 N 10 E 1 TB1 TRANSFORMER 4.50 (114.3) 5.00 (127.0) A 0.25 (6.4) B + - 0.75 (19.1) TB2 B N/C Fixing Holes: A = #6-32 screw mounting holes B = M3 x 0.5 screw mounting holes 8 TB3 N/C Notes: 1. For current share operation, connect signal 0 V (pin 10) between units and current share (pin 7) between units. For non ‘C’ models pin 7 is not used. 2. TB3 is for fan, with Molex 5045-02A or equivalent. 12 V at 200 mA (except JPS350PS05, 5 V at 500 mA). 3. TB1 (AC input) and TB2 (DC output) are terminal blocks. 4. TB4 signal connector is Molex 70246-10 or equivalent. 5. Maximum mounting screw penetration is 0.16 (4.0) from chassis outer surface. 6. Fan/Cover option available, order part number: 5 V models: JPS350 F/CVR 5†^ All other models: JPS350 F/CVR†^ Alternatively, add suffix ‘-E’ to model number to receive cover fitted to the unit 4.95 x 8.92 x 2.48 (127.0 x 228.6 x 62.9). 0.47 (12.0) A TB4 All models 1 TB1 A PIN CONNECTIONS TB2 JPS350PS05 All other models A 6.50 (165.1) 7.50 (190.5) Application Notes Derating Curve Signals 1. To turn off the output, apply 5 V to the Remote On/Off. 2. AC OK is a TTL signal which goes LOW when input falls below 60 VAC at rated load. 3. DC OK is a TTL signal which goes LOW when PSU is in an overcurrent condition, overvoltage condition, disabled or when output falls out of regulation. 4. For AC OK and DC OK signals, source current is 1 mA, sink current is 6 mA. JPS350 with 18 CFM Fan 100 90 80 L O 70 A 60 D 50 40 (%) 30 20 10 0 JPS350 Convection-cooled 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 80 AC-DC JPS350 - Single Output Models and Ratings AC-DC JPS350 - Multi Output Models and Ratings Output 1 Conv. Max Cooled 18 CFM 20 A 35 A 25 A 35 A 25 A 35 A 25 A 35 A Output V1 3.3 V 5.0 V 5.0 V 5.0 V Output V2 5V 12 V 12 V 15 V Output 2 Conv. Max Cooled 18 CFM 20 A 35 A 10 A 14 A 6A 8A 5A 7A Output V3 12 V -12 V 24 V 24 V Output 3 Conv. Max Cooled 18 CFM 4.5 A 6A 2.0 A 3A 3.0 A 4A 3.0 A 4A Output V4 -12 V -5 V -12 V -15 V Output 4 Conv. Max Cooled 18 CFM 1.0 A 3A 1.0 A 2A 2.0 A 3A 1.6 A 3A Model Number JPS350PQ46(2) JPS350PQ41 JPS350PQ47 JPS350PQ48 Notes 1. Maximum power is 350 W with 18 CFM forced air or 300 W with convection cooling. 2. JPS350PQ46 requires 22 CFM max. OVP on V2 (5 V output) not V1. 3. For current share option add suffix ‘C’ to model number. 4. Current share models are built to order. 5. All models require 2 A minimum load on V1. On V2, JPS350PQ46 requires 1 A, PQ41 requires 0.5 A and PQ47/48 requires 2 A. Mechanical Details All dimensions are in inches (mm) Tolerance: ±0.03 (0.8) max. Weight: 2.12 lbs (960 g) approx. JPS350PQ41/47/48 9.00 (228.6) A L B B A *TB4 N *TB6 E TRANSFORMER TB1 4.50 (114.3) 1 1 5.00 (127.0) 10 2 TB3 6 A 0.25 (6.4) B B 0.75 (19.1) TB2 + TB5 A 0.50 (12.7) *TB4: *TB6: 8.00 (203.2) A A B B 0 V (PQ41/48) +5 V (PQ47) +5 V (PQ41/48) 0 V (PQ47) 1.60 (40.6) 0.47 (12.0) JPS350PQ46 Pin 1 2 3 4 5 6 PIN CONNECTIONS - TB2 PQ46 PQ47 0V -12 V +12 V +24 V -12 V 0V 0V 0V 0V +12 V A L B B A TB8 +3.3 V N TB7 0 V E TRANSFORMER TB1 TB4 + - 1 4.50 (114.3) 10 2 TB3 1 5.00 (127.0) TB2 4 TB6 0 V A TB5 +5 V A B B 0.75 (19.1) PQ41 -12 V -5 V 0V 0V 0V +12 V PQ48 +5 V +S +5 V PS(6) +15 V +S DC OK +15 V -S +5 V -S +15 V PS(6) Remote On/Off AC OK 0V PQ48 -15 V +24 V 0V 0V 0V +15 V Notes: 1. TB5 (PQ41/47/48) and TB4 (PQ46) is for fan with Molex 5045-02A or equivalent, PQ47/PQ48 24 V at 100 mA, PQ41/PQ46 12 V at 200 mA. 2. TB1 (AC input) and TB2 (DC output) are terminal blocks. 3. TB3 signal connector is Molex 70246-10 or equivalent. 4. Maximum mounting screw penetration is 0.16 (4.0) from chassis outer surface. 5. Fan/Cover option available, order part number: PQ41, PQ46: JPS350 F/CVR† PQ48 & PQ47: JPS350 F/CVR 24. Alternatively, add suffix ‘-E’ to model number to receive cover fitted to the unit. 6. PS - Single wire parallel on ‘C’ models only. No connection on standard models. 9.00 (228.6) 0.25 (6.4) PIN CONNECTIONS - TB3 PQ46 PQ47 +5 V +S +5 V +S +5 V PS(6) +5 V PS(6) +3.3 V +S +12 V +S DC OK DC OK +3.3 V -S +12 V -S +5 V -S +5 V -S +3.3 V PS(6) +12 V PS(6) Remote On/Off Remote On/Off AC OK AC OK 0V 0V 6.50 (165.1) 7.50 (190.5) 0.87 (22.0) Pin PQ41 1 +5 V +S 2 +5 V PS(6) 3 +12 V +S 4 DC OK 5 +12 V -S 6 +5 V -S 7 +12 V PS(6) 8 Remote On/Off 9 AC OK 10 0V Fixing Holes: A = #6-32 screw mounting holes B = M3 x 0.5 screw mounting holes 6.50 (165.1) 7.50 (190.5) Application Notes Derating Curve Signals JPS350PQ with 18 CFM Fan 100 90 80 L O 70 A 60 D 50 40 (%) 30 20 10 0 1. To turn off the output, apply 5 V to the remote On/Off. 2. AC OK is a TTL signal which goes LOW when input falls below 60 VAC at rated load. 3. DC OK is a TTL signal which goes LOW when PSU is in an overcurrent condition, overvoltage condition, disabled or when output falls out of regulation. 4. For AC OK and DC OK signals, source current is 1 mA, sink current is 6 mA. JPS350PQ Convection-cooled 0 10 20 30 40 50 Ambient Temperature (˚C) 60 70 80 AC OK Signal DC OK Signal AC OK (HIGH) +5 V +5 V 330 R 330 R DC OK (HIGH) AC OK DC OK GND GND AC NOT OK (LOW) DC NOT OK (LOW) Parallel Connection Utilizing Optional Current Share Remote On/Off Control (Inhibit) Supply 1 Output Return OUTPUTS OFF (5V) Remote On/Off V1 Single Wire Parallel LOAD Comm Supply 2 Ground Output OUTPUTS ON (0 V or open circuit) Return Single Wire Parallel Remote Sense Connection Output + Sense + CD + Twisted Pair Supply LOAD CL Sense - Output - Notes: 1. CD is 0.1 µF ceramic capacitor. 2. CL i s 47 µF electrolytic capacitor. CD JPS350 Fan/Cover Option See mechanical details notes for information on how to order. 1.70 (43.2) 2.48 (62.9) Typical internal clearance 0.15 (3.8) 4 x M3 x 6 C/S head fixing screws in existing countersunk holes 17-Apr-07 AC-DC JPS350 Control & Supervisory Signals