FSP FSP100-1K70M1 Medical and ite approval Datasheet

Medical PSU
FSP100-1K70M1
DESCRIPTION
This series of compact, open PC B constructed, AC -DC
switching power supplies are capable of delivering 100
watts of continuous output power at convection cooling.
They are suited for medical, information technology and
industrial applications, but not for life-supporting medical
equipment. Approval to both EN60601-1 and EN60950-1
safety standards improves design-in time and reduces end
equipment compliance costs.
FEATURES
Medical and ITE approvals
C ompact size 2” × 4” × 1.26”
High power density 10 W/cubic inch
100 W output with convection cooling up to +50℃
Low earth leakage current
EN55011 /55022 class B emissions
RoHS compliant
SAFETY STANDARD APPAOVAL
OUTPUT SPECIFICATION
Ripple & Noise:
Maximum excursion of 4% or
better on all models,
recovering to 1% of final
value within 500 us after a
25% step load change
All outputs protected to short
circuit conditions.
W ATTAGE
Wattage:
100W
DIMENSION
Dimension:
101.6mm(L) x 50.8mm(W) x
32.0mm(H)
INPUT SPECIFICATION
Input Range:
Input Frequency:
Input Current:
Leakage Current:
90-264 Vdc
47-63 Hz
1.9A(rms) for100-120VAC ,
1.1A(rms) for200-240VAC
150 µA max. @ 264 VAC ,63
Hz
Over Current
Protection:
GENERAL SPECIFICATION
Efficiency:
Inrush Current:
88~90% @ 230 VAC full load
40A @ 115 VAC or 80A @ 230 VAC ,
at 25"C cold start
ENVIRONMENTAL SPECIFICATION
TEMP.Range:
MTBF:
Operating Temperature:-10°C to
+70°C
Storage Temperature: -40°C to +
85℃
270,000 hours at full load at 25"C
ambient temperature calculated per
MIL-HDBK-217F
*Output Voltage and C urrent Rating
Ripple-Noise(R-P) mV
Regulation Load %
Output Max.(A)
Output Min.(A)
+36V
360mV
±2%
2.78A
0A
NOTES
1. Safety approvals are for PC B form only. To order models with metallic L-bracket or box, change suffix “A” to “B” for Lbracket form, to “C ” for enclosed form (see Outline Drawing of C ased Internal Switchers), e.g. PM100-14C .
2. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line
voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the
output.
MECHANICAL SPECIFICATION
This content is subject to change, please refer to specification for m ore detail.
FSP reserve the right to change the content without prior notice
Similar pages