DIODES BAS19_

SPICE MODELS: BAS19 BAS20 BAS21
BAS19 / BAS20 / BAS21
Lead-free
SURFACE MOUNT FAST SWITCHING DIODE
Features
·
·
·
·
·
·
Fast Switching Speed
Surface Mount Package Ideally Suited for Automatic Insertion
SOT-23
For General Purpose Switching Applications
High Conductance
Lead Free/RoHS Compliant (Note 3)
A
Qualified to AEC-Q101 Standards for High Reliability
Mechanical Data
·
·
B
Case: SOT-23
C
TOP VIEW
Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0
·
·
·
Moisture Sensitivity: Level 1 per J-STD-020C
·
·
·
·
·
Polarity: See Diagram
E
D
G
H
K
Terminals: Solderable per MIL-STD-202, Method 208
Lead Free Plating (Matte Tin Finish annealed over Alloy
42 leadframe).
M
J
L
BAS19 Marking: KA8, KT3, KT2 (See Page 3)
BAS20 Marking: KT2, KT3 (See Page 3)
Dim
Min
Max
A
0.37
0.51
B
1.20
1.40
C
2.30
2.50
D
0.89
1.03
E
0.45
0.60
G
1.78
2.05
H
2.80
3.00
J
0.013
0.10
K
0.903
1.10
L
0.45
0.61
M
0.085
0.180
a
0°
8°
All Dimensions in mm
BAS21 Marking: KT3 (See Page 3)
Weight: 0.008 grams (approximate)
Maximum Ratings @ TA = 25°C unless otherwise specified
Symbol
BAS19
BAS20
BAS21
Unit
Repetitive Peak Reverse Voltage
Characteristic
VRRM
120
200
250
V
Working Peak Reverse Voltage
DC Blocking Voltage
VRWM
VR
100
150
200
V
VR(RMS)
71
106
141
RMS Reverse Voltage
V
Forward Continuous Current (Note 1)
IFM
400
mA
Average Rectified Output Current (Note 1)
IO
200
mA
Non-Repetitive Peak Forward Surge Current @ t = 1.0ms
@ t = 1.0s
IFSM
2.5
0.5
A
Repetitive Peak Forward Surge Current (Note 1)
IFRM
625
mA
Pd
250
mW
RqJA
500
°C/W
Tj , TSTG
-65 to +150
°C
Power Dissipation (Note 1)
Thermal Resistance Junction to Ambient Air (Note 1)
Operating and Storage Temperature Range
Electrical Characteristics @ TA = 25°C unless otherwise specified
Characteristic
Symbol
Min
Max
Unit
V(BR)R
120
200
250
¾
V
IR = 100mA
Forward Voltage
VF
¾
1.0
1.25
V
IF = 100mA
IF = 200mA
Reverse Current @ Rated DC Blocking Voltage (Note 2)
IR
¾
100
15
nA
mA
Tj = 25°C
Tj = 100°C
Total Capacitance
CT
¾
5.0
pF
VR = 0, f = 1.0MHz
Reverse Recovery Time
trr
¾
50
ns
IF = IR = 30mA,
Irr = 0.1 x IR, RL = 100W
Reverse Breakdown Voltage (Note 2)
Note:
BAS19
BAS20
BAS21
Test Condition
1. Part mounted on FR-4 board with recommended pad layout, which can be found on our website
at http://www.diodes.com/datasheets/ap02001.pdf.
2. Short duration pulse test used to minimize self-heating effect.
3. No purposefully added lead.
DS12004 Rev. 18 - 2
1 of 3
www.diodes.com
BAS19 / BAS20 / BAS21
ã Diodes Incorporated
IF, INSTANTANEOUS FORWARD CURRENT (A)
100
1
TA = 150ºC
10
1
0.1
TA = 75ºC
0.1
TA = 25ºC
TA = -40ºC
TA = 0ºC
0.01
0.01
TA = 0ºC
0.001
TA = -40ºC
TA = 25ºC
TA = 75ºC
TA = 125ºC
TA = 150ºC
0.0001
0.001
0
0
0.2
0.4
0.8
1.0
1.2
0. 6
1.4
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics
50
100
150
200
250
VR, INSTANTANEOUS REVERSE VOLTAGE (V)
Fig. 2 Typical Reverse Characteristics
4.0
250
3.5
Note 1
f = 1.0MHz
Pd, POWER DISSIPATION (mW)
CT, TOTAL CAPACITANCE (pF)
TA = 125ºC
3.0
2.5
2.0
1.5
1.0
0.5
200
150
100
50
0
0.0
0
10
20
30
40
VR, REVERSE VOLTAGE (V)
Fig. 3 Typical Capacitance vs. Reverse Voltage
DS12004 Rev. 18 - 2
2 of 3
www.diodes.com
0
40
80
120
160
200
TA, AMBIENT TEMPERATURE (°C)
Fig. 4 Power Derating Curve, Total Package
BAS19 / BAS20 / BAS21
Ordering Information (Note 4)
Notes:
Device
Packaging
Shipping
BAS19-7-F
SOT-23
3000/Tape & Reel
BAS20-7-F
SOT-23
3000/Tape & Reel
BAS21-7-F
SOT-23
3000/Tape & Reel
4. For Packaging Details, go to our website at http://www.diodes.com/datasheets/ap02007.pdf.
Marking Information
YM
KXX = Product Type Marking Code (See Page 1)
YM = Date Code Marking
Y = Year ex: N = 2002
M = Month ex: 9 = September
KXX
Date Code Key
Year
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
Code
L
M
N
P
R
S
T
U
V
W
X
Y
Z
Month
Jan
Feb
March
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Code
1
2
3
4
5
6
7
8
9
O
N
D
IMPORTANT NOTICE
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further
notice to any product herein. Diodes Incorporated does not assume any liability arising out of the application or use of any product described herein; neither
does it convey any license under its patent rights, nor the rights of others. The user of products in such applications shall assume all risks of such use and will
agree to hold Diodes Incorporated and all the companies whose products are represented on our website, harmless against all damages.
LIFE SUPPORT
Diodes Incorporated products are not authorized for use as critical components in life support devices or systems without the expressed written approval of the
President of Diodes Incorporated.
DS12004 Rev. 18 - 2
3 of 3
www.diodes.com
BAS19 / BAS20 / BAS21